Description | In stock
- Strong wooden top.
- With Casters for easy movement.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. |
Shipped from Abroad
SUPiA made by Signers offers such a better clinic environment with no chemicals, ideal space, high-resolution image quality, and affordability.
Delivery & Availability:
Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped from abroad
The Neuropack S3 combines Nihon Kohden’s gold-standard amplifiers with time-saving and easy-to-use clinical software, bringing neurodiagnostic labs a feature-rich system that provides cleaner, easier and faster data. The foundation of effective neurodiagnostic testing is a system that can provide a full complement of neurodiagnostic tests while also offering the quality needed to analyze and monitor nervous system function.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped From Abroad
The product is mainly suitable for solid medical waste (including pollution), waste plastic and rubber etc,at high temperatures they can be divided into organic compounds. We can offer all kinds of waste incinerator for industrial waste, medical waste, chemical waste and daily waste at any capacity.
Delivery & Availability:
Typically 60 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
Used for Clinical Diagnostics.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. |
Content |
- Strong wooden top.
- With Casters for easy movement.
| SUPiA X-ray Digitizer made by Signers offers such a better clinic environment with no chemicals, ideal space, high-resolution image quality, and affordability
FEATURE
Rigid Type
• No damage or scratch on image plates during scanning & erasing
• Scanning & Erasing without a roller
• No cut-off image during winter and cold period
Durability
• Extremely simple structure design
• Strong aluminum base plate
• Flip covers preventing dust from inside scanner
Barcode System
• Automatically recognising cassette sizes(14x17", 10x12", 18x24cm) by barcode reader
Compact & lightweight design
- Very small and compatible CR on desktop (only 63.5cm)
- Only 21.5kg (47.4lbs)
Cassette
Strong structure
• Strong enough against external impact
• Totally metal frame
• Enduring under 150kg on cassette
Featherlight
• 14x17" : 2.05kg 10x12" : 0.99kg 18x24cm : 0.75kg
Dust free & Easy cleaning
• Easy to clean up dust on IPs
• Prevent dust from outside
User friendly design
• Various colors 14x17"(Green),
10x12"(Blue), 18x24cm(Pink))
• Barcode label
TECHNICAL SPECIFICATION
SUPiA Specifications |
|
Cassette |
SUPiA CR Cassette 14x17 (inch)
SUPiA CR Cassette 10x12 (inch)
SUPiA CR Cassette 18x24 (cm) |
Throughput |
Up to 94 IPs/hour (14x17"/160μm) |
Slots |
Single Cassette feed |
Dimensions (W x D x H) |
436 x 636 x 196mm |
Weight |
21.5kg (47.4lbs) |
Grayscale Resolution |
Acquisition : 16 bits per pixel
Display : 12 bits per pixel |
Power Supply Conditions |
Single Phase 50 ~ 60Hz
AC 90 ~ 264V |
Network |
100 MBit |
PC Connection |
USB 2.0 |
Computer Min.
requirements |
OS : Win 7 or 10
CPU : Intel i5
RAM : 4GB
Graphic Card : Intel HD 2500
HDD : 500GB
Monitor : FHD 1920 x 1080
|
Operating conditions |
Temperature : 10 ~ 30˚C
Humidity : 15 ~ 85% RH |
| | The Neuropack S3 combines Nihon Kohden’s gold-standard amplifiers with time-saving and easy-to-use clinical software, bringing neurodiagnostic labs a feature-rich system that provides cleaner, easier and faster data. The foundation of effective neurodiagnostic testing is a system that can provide a full complement of neurodiagnostic tests while also offering the quality needed to analyze and monitor nervous system function.
Features:
- State-of-the-art low-noise amplifier with 18-bit A/D converters and artifact-reduction software provides clean waveforms
- Built-in rejection ratios of 110 dB or greater (differential mode) and 112 dB or greater (isolation mode) limit variations in signals
- Electrode input impedance of 200 MΩ ±20% helps ensure clean signals
- On-screen examination guide directs electrode and stimulation placement for smooth and efficient examinations
- HL7® gateway integration helps ensure quick flow of information and streamlines workflow
- Intuitive control panel and stimulators aid in acquiring and progressing through studies
- Customizable protocols shorten examination time
- One-click report generation produces print-ready reports with customized logos, test results, exam waveforms and highlighted abnormal values
- Proprietary all-in-one NCS program performs MCS, SCS and F-wave for quick examinations
- Customized auto-copy settings allow waveforms to be stored and automatically transferred to long-term storage
Technical Specifications:
Main unit: DC-960B
Electrode junction box, 2 or 4 ch: JB-962B or JB-964B
Control unit, desktop: GG-961BK
Power supply: SC-230BK
Cart: KD-026A
Arm: KH-960A
Holder: DI-961B
Somato control box: RY-960B
LCD display: Local purchase
Printer: Local purchase
Number of channels: 2 or 4
Input impedance Common mode: >100 MΩ
Differential Mode: >200 MΩ
CMRR Differential Mode: >106 dB
Isolation Mode: >112 dB
Noise level: 0.6 μVrms
Sampling Resolution: 18 bit
Sensitivity: 1 to 500 μVrms/div., and 1 to 10 mVrms/div.
Low-cut filter: 0.01 Hz to 3 kHz
High-cut filter: 10 kHz to 20 kHz
Analysis time base: 0.1 ms/div to 1 s /div
Model Suffixes
EEG-1200 has the following suffixies:
J: 110-127 V AC operation
K: 220-240 V AC operation
| LDF series waste incinerator adopt gasification combustion that can make garbage more sufficient burning. Waste incinerator is a kind of machine that possess the own intellectual property, features unique and advanced merits with compact size, high burning efficiency, reasonable burning technology, high degree of non-harm etc, it is an ideal choice for waste treatment of hospital, hotels, various stations and industries.
Features:
- Both gas-motivated and oil-motivated are all can be preferred according to customers' needs.
- Gasified incineration is used for burning syringe, paper waste, bandage, absorbent cotton and other medical wastes.
- Daily waste can be burned once by gasified incineration.
- Gasified incineration, mixed incineration and burnout treatment ensures low emission standard of dust (lower than International standard).
- Totally enclosed operation is suitable for treating infectious waste to avoid secondary pollution.
Advantages:
- Long lifetime
- Totally enclosed operation
- Suitable for treating infectious waste
- Avoid secondary pollution
- Simple operation
- Smokeless and no harmful to environment
- Continuously and fully burning
- Simple operation
Incinerator LDF-100 Parameter:
Applicable hospital size |
250 beds |
Max. Burning Ability |
100 kg/time |
Size of the Burner |
1.5m×1.15m×3m |
Volume of the Burner |
Gasification room 0.5m3 |
second buming room 0.3m3 |
Chamber Temperature |
First chamber:600℃-700℃; |
second chamber:300℃-1300℃ |
|
Ash residue |
≤5% |
Size of the filling entrance |
620mm×800mm |
Chimney |
Hight 10m,Out-radiusØ300 |
Blower |
0.37kw |
Auxiliary machine |
Power0.11kw,fuel consumption4-10kg/h |
Re-burning machine |
Power0.11kw,fuel consumption6-10kg/h |
Running voltage |
220V or 380V |
Weight |
About 4600(kg) |
Flue&Gas Emission Standards:
OrdinalNumber |
Refuse name |
Measuring unit |
GB18484-2001 |
1 |
Blackness of Flue |
Ringelmann class |
1 |
|
|
|
Gas |
|
|
|
2 |
Smoke&Dust |
mg/m3 |
100 |
|
3 |
CO |
mg/m3 |
100 |
|
4 |
SO2 |
mg/m3 |
400 |
|
5 |
HF |
mg/m3 |
9.0 |
|
6 |
HCL |
mg/m3 |
100 |
|
7 |
NO2 |
mg/m3 |
500 |
Click Here To Download Catalogue | Used for Clinical Diagnostics.
- Test Method: Dry Strip color-developing method
- Test Principle: Dual wavelength reflectance photometry
- Light Source: Cold Lamp with high brightness and long lifetime
- Test System: Color-indentify system with high sensitivity and repeatability
- Wavelength: 520nm, 640nm, 660nm
- Throughput: 120 Strips/Hour
- Test Mode: Single and continuous test mode are selectable
- Test Slot: Using sliding Slot, Easy to clean and replace, lower the carryover
- Waste Collection: Waste urine and waste strips can be collected automatically
- Test Strip: Use GENIUS original strips only
- Display: LCD with high brightness and resolution
- Language: Customizable language software
- Memory: Save 2000 samples results, and auto recover the results when power off during working
- Interface: RS-232 serial port, can be connected to external printer and computer Printer: Inner thermal printer, can be connected to external printer
- Report format: Half quantitative and qualitative, report the color and turbidity is available
- Result unit: SI unit and routine unit are selectable
- Status Check: Auto-check the status during power on and off, auto-indentify the alarm
- Working Environment: Temperature10℃~30℃; Humidity: 20%RH~80%RH
- Power: 100-240V, Auto adapt according to the input voltage
- Consumption: ≤80VA
- Quality System: Certified by TUV and CMD
|
Reviews