BT 125 Auto Biochemistry Analyzer (200 T/H)
Ask for Price$0.00
Shipped From Abroad
Features and Benefits:
- Photoelectric colorimetry
- Constant 200 T/H
- End Point, Kinetic, Two point
- 40 sample positions
- 40 reagent positions
- 60 reusable reaction cuvette
Delivery & Availability:
Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
Features and Benefits:
- Photoelectric colorimetry
- Constant 200 T/H
- End Point, Kinetic, Two point
- 40 sample positions
- 40 reagent positions
- 60 reusable reaction cuvette
Specification:
Instrument Performance | |
Principle: | Photoelectric colorimetry |
Assay Method: | End Point, Kinetic, Two point etc. |
Throughput: | Constant 200 T/H |
Stat Function: | Spesific emergency positions |
Sample System | |
Sample Disk: | 40 sample positions include standard, QC, STAT positions |
Sample Probe: | High-polished probe, automatical liquid level detection and tracing, collising protection, 2-50µL with 0,1µL increment |
Reagent System | |
Reagent Disk: | 40 reagent positions, supporting different type of bottles |
Cooling System: | 2-8 °C 24h non-stop cooling system |
Reagent Probe: | High-polished probe, automatical liquid level detection and tracing, collision protection |
Optical System | |
Light Source: | Halogen-Tungsten lamp with long life, 12V, 20W |
Photometry Range: | 0-4.0Abs |
Wavelength: | 9 wavelengths (300nm-700nm) |
Reaction System | |
Reaction Cuvette: | 60 reusable reaction cuvette |
Washing System: | 8-step warm water washing |
Min Reaction Volume: | 180µL |
Heating System: | 37±1 °C |
Others | |
Dimension: | 415mm (W) x 565mm (L) x 385mm (H) |
Weight: | 28kg |
Water Consumption: | <3L/H |
Click Here To Download Catalogue
Quick Comparison
Settings | BT 125 Auto Biochemistry Analyzer (200 T/H) remove | Syringe Needle Destroyer remove | AB Diagnostic HBs Ag Elisa Kit remove | Sterile Swab Stick Per Pack remove | AB Diagnostic FSH Elisa Kit remove | AB Diagnostic HCV Ab Elisa Kit remove | ||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Name | BT 125 Auto Biochemistry Analyzer (200 T/H) remove | Syringe Needle Destroyer remove | AB Diagnostic HBs Ag Elisa Kit remove | Sterile Swab Stick Per Pack remove | AB Diagnostic FSH Elisa Kit remove | AB Diagnostic HCV Ab Elisa Kit remove | ||||||||||||||||||||||||||||||||||||||||||||||||||
Image | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
SKU | SF1033560079 | SF1033560084-206 | SF1033560084-210 | SF1033560084-185 | SF1033560084-209 | SF1033560084-211 | ||||||||||||||||||||||||||||||||||||||||||||||||||
Rating | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Price | Ask for Price | $157.00 | Ask for Price | $10.50 | Ask for Price | Ask for Price | ||||||||||||||||||||||||||||||||||||||||||||||||||
Stock | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Availability | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Add to cart | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Description | Shipped From Abroad
Features and Benefits:
| In stock
Needle destruction destroy the needle immediately following its use. Needle destruction are an absolute necessity in developing parts of the world to prevent the reuse of needles and the spread of bloodborne pathogens. They are NOT a good alternative, however, for hospital use in the developed parts of the world. Needle destruction are products that bend, cut, or destroy the needle. This are distinctly different from needle destroyer that send an arc of electricity to vaporize and melt the needle.
| In stock
Abia HBs Ag is an enzyme immunoassay for the qualitative detection of wild types and mutant variants hepatitis B surface antigen (HBsAg) in human serum or plasma.
| In stock
| In stock
Abia FSH is an enzyme immunoassay for the quantitative determination of follicle stimulating hormone (FSH) concentration in human serum.
| In stock
Abia HCV Ab is an enzyme immunoassay for the qualitative detection of antibodies to hepatitis C virus (HCV) in human serum or plasma.
| ||||||||||||||||||||||||||||||||||||||||||||||||||
Content | Features and Benefits:
Specification:
Click Here To Download Catalogue | Needle destruction destroys the needle immediately following its use. Needle destruction are an absolute necessity in developing parts of the world to prevent the reuse of needles and the spread of bloodborne pathogens. They are NOT a good alternative, however, for hospital use in the developed parts of the world. Needle destruction are products that bend, cut, or destroy the needle. This are distinctly different from needle destroyer that send an arc of electricity to vaporize and melt the needle.
Features:
| Abia HBs Ag is an enzyme immunoassay for the qualitative detection of wild types and mutant variants hepatitis B surface antigen (HBsAg) in human serum or plasma.
Abia HBs Ag DK.013.01.3 (Packaging Contents):
HBs Ab coated plate: 5 plates
Conjugate 1 (concentrated 11-fold): 3.5 ml
Conjugate 2 (concentrated 11-fold):3.5 ml
Positive control (inactivated): 2.5 ml
Low positive control (inactivated): 2.5 ml
Negative control (inactivated): 5 ml
Conjugate 1 diluent: 36 ml
Conjugate 2 diluent: 36 ml
Washing solution (concentrated 25-fold): 240 ml
TMB (concentrated 11-fold): 7 ml
Substrate buffer: 70 ml
Stopping reagent 0.2M H2SO4: 90 ml
HBs Ab coated plate: 5 plates
Conjugate 1 (concentrated 11-fold): 3.5 ml
Conjugate 2 (concentrated 11-fold): 3.5 ml
Positive control (inactivated): 2.5
Low positive control (inactivated): 2.5 ml
Negative control (inactivated): 5 ml
Conjugate 1 diluent: 36 ml
Conjugate 2 diluent: 36 ml
Washing solution (concentrated 25-fold): 240 ml
TMB (concentrated 11-fold): 7 ml
Substrate buffer: 70 ml
Stopping reagent 0.2M H2SO4: 90 ml
Protective film: 15
Plastic zip-lock bag: 5
Protective film:15
Plastic zip-lock bag: 5
|
| Abia FSH is an enzyme immunoassay for the quantitative determination of follicle stimulating hormone (FSH) concentration in human serum.
| Abia HCV Ab is an enzyme immunoassay for the qualitative detection of antibodies to hepatitis C virus (HCV) in human serum or plasma.
Abia HCV Ab (D.K.067.01.3):
Abia HCV Ab (D.K.067.05.3):
| ||||||||||||||||||||||||||||||||||||||||||||||||||
Weight | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||||||||||||||||||||||||||||||
Dimensions | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||||||||||||||||||||||||||||||
Additional information |
Reviews
There are no reviews yet.