KEDEE KD-2260 Manual Rotary Microtome
$2,970.00
Ship From Abroad
The Microtome KD-2260 is designed to meet multiple requirements of histology or histopathology labs. It is also suitable for the use in research labs as well as industrial quality assurance. In being manual, the Microtome KD-2260 is flexible to use at any place in the laboratory.
Delivery & Availability:
Typically 14-21 Working Days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
The Microtome KD-2260 is designed to meet multiple requirements of histology or histopathology labs. It is also suitable for the use in research labs as well as industrial quality assurance. In being manual, the Microtome KD-2260 is flexible to use at any place in the laboratory. With its high-precision mechanics inside, the Microtome KD-2260 permits quality sections, while maintaining a high, consistent throughput. Great functionality and the appealing design are the key features of our microtome. Optimal user comfort enables a rapid, safe and smooth sectioning, even under heavy workload. The integrated sectioning waste tray is resistant to xylene, and can be detached for cleaning.
Technical Specifications:
- Section Thickness Setting Range: 0–60μm
- Section thickness settingoptions:
0–2μm increment 0.25μm
2–10μm increment 1μm
10–20μm increment 2μm
20–60μm increment 5μm
- Trimming Thickness Setting Range: 0- 60μm
- Minimum Setting of Sectioning Thickness: 1μm
- Total Horizontal Specimen Feed:29mm;
- Vertical Specimen Stroke:60mm
- Movement Range of the Base of BladeHolder Base: 0-60mm (front to back)
- Movement Range of the Blade Press plate: 0-23mm
- Specimen Holder Rotation: at any angle within360 degrees
- Maximum Specimen Size: 60×70mm
- Specimen Orientation:XY – 8°
- Precision Error: ±1%
- Dimensions: 570×440×290mm (W×D×H)
- Net weight: 28kg
Review(1)
Quick Comparison
Settings | KEDEE KD-2260 Manual Rotary Microtome remove | Avalun LabPad Device remove | AGD Erma EL-120 ELectrolyte Analyzer remove | Erma B-111 Bilirubin Meter remove | Hawksley 1400 Haematocrit Centrifuge remove | Eppendorf Pipette Tip 20ul Per Pack remove | ||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Name | KEDEE KD-2260 Manual Rotary Microtome remove | Avalun LabPad Device remove | AGD Erma EL-120 ELectrolyte Analyzer remove | Erma B-111 Bilirubin Meter remove | Hawksley 1400 Haematocrit Centrifuge remove | Eppendorf Pipette Tip 20ul Per Pack remove | ||||||||||||||||||||||||||||
Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ||||||||||||||||||||||||||||
SKU | SF10335601250 | SF1033560084-65 | SF1033560084-125 | SF1033560084-6 | SF1033560084-118 | SF1033560084-136 | ||||||||||||||||||||||||||||
Rating | ||||||||||||||||||||||||||||||||||
Price | $2,970.00 |
| $1,320.00 | $715.00 | $690.00 |
| ||||||||||||||||||||||||||||
Stock | ||||||||||||||||||||||||||||||||||
Availability | ||||||||||||||||||||||||||||||||||
Add to cart | ||||||||||||||||||||||||||||||||||
Description | Ship From Abroad
The Microtome KD-2260 is designed to meet multiple requirements of histology or histopathology labs. It is also suitable for the use in research labs as well as industrial quality assurance. In being manual, the Microtome KD-2260 is flexible to use at any place in the laboratory. Delivery & Availability: Typically 14-21 Working Days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped From Abroad
| Shipped From Aboard
The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.
Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
| In stock
| ||||||||||||||||||||||||||||
Content | The Microtome KD-2260 is designed to meet multiple requirements of histology or histopathology labs. It is also suitable for the use in research labs as well as industrial quality assurance. In being manual, the Microtome KD-2260 is flexible to use at any place in the laboratory. With its high-precision mechanics inside, the Microtome KD-2260 permits quality sections, while maintaining a high, consistent throughput. Great functionality and the appealing design are the key features of our microtome. Optimal user comfort enables a rapid, safe and smooth sectioning, even under heavy workload. The integrated sectioning waste tray is resistant to xylene, and can be detached for cleaning.
Technical Specifications:
| The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes.
Click Here To Download Catalogue | Electrolyte Analyzer ERMA EL-120 is ideal for medium to high volume Laboratories and Hospitals . It offers reliable, automated samples handling and work flow offences . It also allows measurement of specific ions, accurately and precisely . This supports fast diagnosis of critically ill patients and reduces the risks of patient discomfort associated with repeated sampling Precise & Accurate Results Economical to use Large Touchscreen Display with Graphical User Interface.
Features:
Click Here To Download Catalogue | The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric
analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.
Feature
| The Hawksley Haematospin 1400 Centrifuges are built in the UK and are made from durable and high-quality components. These centrifuges are ideal for veterinary laboratories and practices specifically designed to produce reliable and accurate results on blood and urine. One of the main features of this centrifuge is that it takes both 2ml microtubes and 75mm microhaematocrits. The classic design of these centrifuges is used worldwide with guaranteed support for all servicing and parts.
Technical specifications:
Click Here To Download Catalogue |
| ||||||||||||||||||||||||||||
Weight | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||||||||
Dimensions | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||||||||
Additional information |
Meshack shiundu