Neuro-TES is a Transcranial Electrical Stimulator (TES) designed for precise neuromodulation and intraoperative neuroprotection. It delivers controlled electrical stimulation to the brain and nervous system, aiding in motor cortex mapping, functional monitoring, and rehabilitation. Ideal for neurologists, neurosurgeons, and physiatrists, Neuro-TES ensures safe and effective stimulation, enhancing patient outcomes in neurosurgery and neurorehabilitation. With advanced technology and a user-friendly interface, it provides reliable performance in both clinical and research settings.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130187-25
Brands:: Neurosoft

Description

Stimulus Intensity – 1000 V

Neuro-TES transcranial electrical stimulator is intended for stimulation of motor cortex to record motor evoked potentials from muscles. These potentials allow to estimate the integrity of motor pathways.

Main Specifications:
  • stimulus intensity – 0-1000 V with 5 V step;
  • maximum pulse current – 1.5 A;
  • pulse duration – 40 μs, 50 μs, 60 μs, 70 μs, 80 μs, 200 μs;
  • pulse waveform – biphasic, monophasic;
  • stimulation type: single pulse, train, double train, train + pulse;
  • number of pulses in train – 1-9.

The electrical stimulator is powered via USB.

Application in Intensive Care Units and Operating Rooms

The electrical stimulator can be used together with IOM system in intensive care units, operating rooms and experimental laboratories of research institutions to:

  • estimate the central nervous system state;
  • study the human neuromuscular system at intraoperative neurophysiological monitoring.

Synchronization with Neurosoft Diagnostic System or Third-party Equipment

The electrical stimulator can operate as a part of IOM system manufactured by Neurosoft or IOM system of third-party manufacturer.
The synchronization of electrical stimulator with Neurosoft equipment is done via USB. To synchronize the electrical stimulator with IOM systems of third-party manufacturer the trig in/out is used.

4-Channel Electronic Switch

The electrical stimulator can be supplied with a 4-channel electronic switch which is placed in a patient zone in a 5-meter distance from the stimulator and control PC.
You can select the following switch:

  • electronic switch;
  • mechanical switch with external pod.

Neuro-TES software performs the switching in case the stimulator is used with electronic switch. If the stimulator is supplied with mechanical switch, use knobs on its front panel to perform the switching.

Download Brochure

Reviews

There are no reviews yet.

Be the first to review “Neuro-TES-Transcranial Electrical Stimulator”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsNeuro-TES-Transcranial Electrical Stimulator removeNitrogen Generator/Plant removeBRAINSWAY Deep TMS H7 RCT Coil removeSomatics Electroconvulsive Therapy (ECT) Machine removeEctron Ectonustim Series 6 Electroconvulsive Therapy ECT Machine removeSelf-Retaining Retractor remove
NameNeuro-TES-Transcranial Electrical Stimulator removeNitrogen Generator/Plant removeBRAINSWAY Deep TMS H7 RCT Coil removeSomatics Electroconvulsive Therapy (ECT) Machine removeEctron Ectonustim Series 6 Electroconvulsive Therapy ECT Machine removeSelf-Retaining Retractor remove
Image
SKUSF1033560130187-25SF103356013077SF1033560130162-6SF1033560106-1SF10335601235SF1033560130176-10
Rating
Price

$0.00

$0.00

$0.00

$0.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad Neuro-TES is a Transcranial Electrical Stimulator (TES) designed for precise neuromodulation and intraoperative neuroprotection. It delivers controlled electrical stimulation to the brain and nervous system, aiding in motor cortex mapping, functional monitoring, and rehabilitation. Ideal for neurologists, neurosurgeons, and physiatrists, Neuro-TES ensures safe and effective stimulation, enhancing patient outcomes in neurosurgery and neurorehabilitation. With advanced technology and a user-friendly interface, it provides reliable performance in both clinical and research settings.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
PSA Industrıal nitrogen generator systems produce gas nitrogen from compressed air from the field where they work, and switch compatible to conventional nitrogen gas source such as tubes or cryogenic liqiud. Delivery & Availability: Typically, 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad The H7 Coil stimulates the anterior cingulate cortex and the medial prefrontal cortex.  Treatment is designed to regulate the CSTC circuit believed to be involved in the inhibition of impulsive behavior. A sham coil is integrated above the treatment coil. To the patient and operator, the helmet appears the same, pulses sound the same, and stimulation feels the same on the scalp.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from abroad The machine provides higher stimulus current, deeper cerebral stimulus penetration, and better seizure generalization. It provides the most effective form of bilateral brief pulse ECT with a 0.5msec pulsewidth that minimizes side-effects and can be delivered at every stimulus dose including the maximum dose with efficient and accurate stimulus titration.
Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
Shipped From Abroad

This machines have been developed from the well-proven Series 5A and 5B ECT apparatus. The series 6+ models incorporate all the features of the corresponding Series 5B versions. Experience has shown that a very few patients sometimes require higher dosage than was available with the earlier machines and the opportunity was therefore taken to produce equipment with a second, higher, output range.

Delivery & Availability: Typically 3 Months – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
ContentStimulus Intensity – 1000 V Neuro-TES transcranial electrical stimulator is intended for stimulation of motor cortex to record motor evoked potentials from muscles. These potentials allow to estimate the integrity of motor pathways.
Main Specifications:
  • stimulus intensity – 0-1000 V with 5 V step;
  • maximum pulse current – 1.5 A;
  • pulse duration - 40 μs, 50 μs, 60 μs, 70 μs, 80 μs, 200 μs;
  • pulse waveform – biphasic, monophasic;
  • stimulation type: single pulse, train, double train, train + pulse;
  • number of pulses in train – 1-9.
The electrical stimulator is powered via USB. Application in Intensive Care Units and Operating Rooms The electrical stimulator can be used together with IOM system in intensive care units, operating rooms and experimental laboratories of research institutions to:
  • estimate the central nervous system state;
  • study the human neuromuscular system at intraoperative neurophysiological monitoring.
Synchronization with Neurosoft Diagnostic System or Third-party Equipment The electrical stimulator can operate as a part of IOM system manufactured by Neurosoft or IOM system of third-party manufacturer. The synchronization of electrical stimulator with Neurosoft equipment is done via USB. To synchronize the electrical stimulator with IOM systems of third-party manufacturer the trig in/out is used. 4-Channel Electronic Switch The electrical stimulator can be supplied with a 4-channel electronic switch which is placed in a patient zone in a 5-meter distance from the stimulator and control PC. You can select the following switch:
  • electronic switch;
  • mechanical switch with external pod.
Neuro-TES software performs the switching in case the stimulator is used with electronic switch. If the stimulator is supplied with mechanical switch, use knobs on its front panel to perform the switching. Download Brochure
PSA Industrıal nitrogen generator systems produce gas nitrogen from compressed air from the field where they work, and switch compatible to conventional nitrogen gas source such as tubes or cryogenic liqiud.

ADVANTAGES OF NITROGEN GENERATORS/PLANT

  • High flow capacity: The wide product range and gas flows exceeding 1,000 Nm³/h

  • Desired purity: Nitrogen concentrations from 95% to 99.999%.

  • Continuous availability: 24 hours a day, 7 days a week

  • Cost savings: Low operating expenses, limited maintenance costs.

  • Fully automated and monitored including oxygen sensor as standard.

Wide Range Of Applications

  • Food & beverage (storage & packaging).

  • Pharmaceutical applications.

  • Plastic injection molding.

  • Electronics.

  • Laser cutting.

  • Semiconductor manufacturing.

  • Chemical applications.

  • Metal heat treatment.

  • Cable & optical fiber industries.

  • Glass industries.

  • Fire prevention.

  • Aquaculture.

grafik_son.jpg
The Brainsway Deep TMS H7 RCT Coil is a flexible coil used in transcranial magnetic stimulation (TMS) to treat obsessive-compulsive disorder (OCD) and other neuropsychiatric conditions:
  • What it does
    The H7 Coil stimulates the medial prefrontal cortex and the anterior cingulate cortex of the brain. TMS uses magnetic pulses to create an electrical current in the brain's neuronal tissue. 
  • How it's used
    The H7 Coil is integrated into a cooled, cushioned helmet that allows the patient to move around during treatment. A sham coil is also included so that the patient and operator can't tell the difference between the treatment and sham coils. 
  • What it's used for
    The H7 Coil is FDA-cleared for OCD, but it's also been shown to be effective in treating other conditions, including addiction, major depressive disorder, and autism spectrum disorder. 
  • How it works
    The H7 Coil is designed to regulate the CSTC circuit, which is thought to be involved in impulsive behavior. 
  • Safety
    A 2023 paper that analyzed adverse events from five large, randomized controlled trials found that most adverse events were transient and resolved within days.
Features
  • Stimulates specific brain regions
    The H7 Coil targets the anterior cingulate cortex and the medial prefrontal cortex. 
  • Flexible windings
    The H7 Coil's flexible windings conform to the shape of the patient's head. 
  • FDA-cleared for OCD
    The H7 Coil is FDA-cleared for treating obsessive-compulsive disorder (OCD). 
  • Demonstrated efficacy
    The H7 Coil has been shown to be effective in treating OCD patients with varying degrees of severity and comorbidities. 
  • Integrated sham coil
    The helmet includes a sham coil that makes the treatment appear, sound, and feel the same to the patient and operator.

Click here to download Brochure

The machine provides higher stimulus current, deeper cerebral stimulus penetration, and better seizure generalization. It provides the most effective form of bilateral brief pulse ECT with a 0.5msec pulsewidth that minimizes side-effects and can be delivered at every stimulus dose including the maximum dose with efficient and accurate stimulus titration. Features-
  • Choose 0.25, 0.3 or 0.5msec Ultrabrief Pulsewidth
  • Genie™ IV EEG Analyzing Software
  • Four (4) - Channel Monitor/Printer
  • Optimal Stimulus Programs
  • Maximum Sustained EEG Amplitude
  • Continuous Digital Heart Rate Monitor
  • Peak Heart Rate Printout
  • EEG Coherence Analysis
  • Seizure Energy Index
  • Postictal Suppression Index
  • Maximum Dose Available at all Pulsewidths
  • Interictal Frontal Delta Analysis
  • Computer EEG Seizure Duration
  • Computer Motor Seizure Duration
  • True EMG Monitor
  • EEG Ictal Line Seizure Indicator
  • Light-Emitting Elapsed Time Display
  • Up to 8 Seconds of Stimulation
  • Change Waveform without Altering Dose
  • Audible EEG™ monitor
  • Instant Impedance Test
  • Extended Seizure Alert
  • Patented Safety Monitor Circuit
ECT Machine with Standard Accessories below: Article           Qty      Description                                                                           SYS-IV            1                     Thymatron System IV , with following accessories: EGEN              1         Genie-IV EEG Analyzing Software ELDS9            1                     Set with 9 lead wires  (4 red / 4 black / 1 green) EPAD              10       Disposable ECT treatment electrodes "Thymapad" (5 Pair) ECEF-IV        1                     EEG/EMG/ECG-monitoring cable ECET-IV        1                     ECT-treatment cable EEDS              50       Pregelled EEG/EMG stick-on electrodes EMGD           2                     Mouthguard oral protectors, 2 sizes CP110            2         Z-fold chart paper EDVD             1         Audio training DVD EMAE             2         Operating manual English ESERV           1         Service manual English For further treatments you can order separately following accessories: EECU/EEFL - Stainless steel electrode, cupped (EECU) or flat (EEFL) EHST- Headstrap, latex rubber, perforated EHAN-Electrode handle, fully shielded, for flat or cupped electrode.
Click Here To Download Catalogue
This machines have been developed from the well-proven Series 5A and 5B ECT apparatus. The series 6+ models incorporate all the features of the corresponding Series 5B versions. Experience has shown that a very few patients sometimes require higher dosage than was available with the earlier machines and the opportunity was therefore taken to produce equipment with a second, higher, output range. Features: Constant Current stimulus Delivered Dosage Displayed Patient Dynamic Impedance Indicator Simple Single Dose Control Technical Specification: Input Supply: AC 100-120, 210-240 V 40/60 Hz Load: 70 W Apparatus Size: 305 x 170 x 105mm (12” x 6.5” x 4”) Weight: 3.24kg Low Range: 50-700mC @ 750mA High Range: 200-100mC @ 900mA Contents: Two-hand headpiece: 1 C.S lead: 1 Disposable electrodes: 50 Mains cable: 1 Operating & service manual: 1 Removable stand: 1  
Click Here To Download Catalogue
CODE SIZE FINISH
01-01-02 12.8 cm sharp
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare