OBS-100A Monopolar Electrosurgical Unit

$0.00

Shipped From Abroad

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130165-7
Brands:: OBS

Description

 

Features

1. Portable and  affordable

2. Suitable for general surgery and veterinary

Technical Details
Environmental temperature range: 5°C~ 40°C
Relative moisture range: ≤80%
Atmosphere pressure range: 86.0 Kpa ~ 106.0 Kpa

Working modes:

Pure cut: 5w ~ 100w (Load:300Ω)
Blend cut: 5w ~ 50w (Load:300Ω)
Forced coagulation: 5w ~ 80w (Load:500Ω)
Soft coagulation: 5w ~ 50w (Load:500Ω)

Technology data:

Voltage: 230V±10V, 50Hz
Working frequency: 330KHz ~ 460KHz
Leakage currents to ground: Less than 0.5mA
Leakage currents to patient: Less than 0.01mA

Reviews

There are no reviews yet.

Be the first to review “OBS-100A Monopolar Electrosurgical Unit”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsOBS-100A Monopolar Electrosurgical Unit removeBipolar Irrigated Coagulator removeOBS-100C(I) Intelligent Electrosurgical Unit removeBipolar Artery Forceps removeDisposable LOOP Tungsten Electrode removeElectrosurgical Forceps remove
NameOBS-100A Monopolar Electrosurgical Unit removeBipolar Irrigated Coagulator removeOBS-100C(I) Intelligent Electrosurgical Unit removeBipolar Artery Forceps removeDisposable LOOP Tungsten Electrode removeElectrosurgical Forceps remove
Image
SKUSF1033560130165-7SF1033560130165-12SF1033560130165-2SF1033560130165-20SF1033560130165-14SF1033560130165-19
Rating
Price

$0.00

$0.00

$0.00

$0.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad Portable in size, available in both monopolar and bipolar modes, convenient handle power control and memory function, suitable for microsurgery, gynecology, and arthroscopy.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad Mainly used for bipolar subtle coagulation in microsurgery, neurosurgery, spine surgery, and medical cosmetology
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content  
Features

1. Portable and  affordable

2. Suitable for general surgery and veterinary
Technical Details
Environmental temperature range: 5°C~ 40°C
Relative moisture range: ≤80%
Atmosphere pressure range: 86.0 Kpa ~ 106.0 Kpa
Working modes:
Pure cut: 5w ~ 100w (Load:300Ω)
Blend cut: 5w ~ 50w (Load:300Ω)
Forced coagulation: 5w ~ 80w (Load:500Ω)
Soft coagulation: 5w ~ 50w (Load:500Ω)
Technology data:
Voltage: 230V±10V, 50Hz
Working frequency: 330KHz ~ 460KHz
Leakage currents to ground: Less than 0.5mA
Leakage currents to patient: Less than 0.01mA
Features

1. LED light positioned between the electrodes enhances the vision during surgery.

2. Massive area hemostasis can be performed in a short time in order to reduce intraoperative blood loss 3. Saline line and dripping device are equipped in an attempt to contain the heat on the treated tissue and avoid thermal tissue damage
Indications for Use
  • Ensure that both electrodes are in contact with the tissue to be treated. Activation and saline flow occur simultaneously.
  • Ensure that saline is flowing at the time of activation
  • These devices should never be used when:
  • There is visible evidence of damage to the exterior of the device such as cracked or damaged plastic or connector damage.
  • These devices fail the inspection described herein.
  • In the presence of flammable gases, flammable prep solutions or drapes. Oxidizing. Gases such as Nitrous Oxide (N2O), or in oxygen-riched environments.
  • Do not use monopolar electrosurgery on small appendages, as in circumcision or finger surgery.
 
Key Features
OBS-100 Electrosurgical Generator with state-of-art technology offers superb performance on the electro-surgery, and shows remarkable safety, reliability and convenience. 1. Two levels of coagulation: pinpoint coagulation and fulguration Pinpoint coagulation provides precise control of bleeding in localized areas. Fulguration provides greater control of bleeding in highly vascular over-surface areas. 2. Presets The unit incorporates as many as ten user-defined presets for easy recall of frequency and settings. 3. Isolated RF output for Cut, Blend, and Coag modes This minimizes the potential of alternate site burns. 4. Ground Referenced RF output for Fulguration modes 5. Self-diagnostics These diagnostics continually monitor the unit to ensure proper performance. If the diagnostics is unsuccessful, the warning tones can be heard.
Technical parameters:
Environmental temperature range: 5°C~ 40°C
Relative moisture range: ≤80%
Atmosphere pressure range: 86.0 ~ 106.0 Kpa
 Working modes:
Pure cut: 1w ~ 60w (Load 500Ω)
Blend: 1w ~ 60w (Load 800Ω)
Coagulation: 1w ~ 60w (Load 1000Ω)
Fulguration: 0.1w ~ 35w (Load 1000Ω)
Bipolar: 1w ~ 30w (Load 200Ω)
Technology data:
Voltage: 220V±10V, 50Hz ±1Hz
Working frequency: 357 KHz ~ 575 KHz
Leakage currents to ground: Less than 0.5mA
Leakage currents to patient: Less than 0.01mA
Display Setting: Fulguration a.      0-10 range: 0.1watt increments b.      10-35range: 1.0 watt increments Cut, Blend, Coagulation, and Bipolar 1.0-watt increments Power supply:220V±10%,50±1%Hz. Transportation and storage a)        Ambient temperature range: -40°C~55°C; b)        Relative moisture range: ≤95%; c)        Atmosphere pressure range: 500hPa~1060hPa. Accessories Included: Electrosurgical Pencil, disposable                           2pcs Bipolar Forceps with cable, reusable                      1pc Disposable Electrosurgical Pad                               2pcs Cable for Electrosurgical Pad, reusable                  1pc Footswitch                                                              1pc Power cord                                                             1pc Manual                                                                    1pc
 
Features
1. Stainless steel & non-stick finish 2. The hexagonal connection ring fits the pencil locking design. 3. Different shapes fitting for different surgeries
Features
  • Biocompatible Material, latex-free in construction
  • Ratchet handles are designed ergonomically which comfortably fit into the surgeon´s hand
  • Nylon coating resists abrasion and provides superb insulation.
  • Well-balanced and highly polished tips aid fine control.
  • 50-time autoclave
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare