Description | In stock
- Strong wooden top.
- With Casters for easy movement.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
Ear / Ulcer Bulb Syringes are ideal for irrigating smaller wounds and alleviating congestion. The syringes are available in several sizes to meet clinical requirements.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
Needle destruction destroy the needle immediately following its use. Needle destruction are an absolute necessity in developing parts of the world to prevent the reuse of needles and the spread of bloodborne pathogens. They are NOT a good alternative, however, for hospital use in the developed parts of the world. Needle destruction are products that bend, cut, or destroy the needle. This are distinctly different from needle destroyer that send an arc of electricity to vaporize and melt the needle.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
Material Stainless: Steel
Height Adjustable: Yes
Number of Wheel: 4
Height: 3-4 Feet
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
Used for Clinical Diagnostics.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped From Abroad
The product is mainly suitable for solid medical waste (including pollution), waste plastic and rubber etc,at high temperatures they can be divided into organic compounds. We can offer all kinds of waste incinerator for industrial waste, medical waste, chemical waste and daily waste at any capacity.
Delivery & Availability:
Typically 60 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. |
Content |
- Strong wooden top.
- With Casters for easy movement.
| Ear / Ulcer Bulb Syringes are ideal for irrigating smaller wounds and alleviating congestion. The syringes are available in several sizes to meet clinical requirements.
- Disposable syringe for aspiration and irrigation
- Ideal for suctioning a newborn's airway
- Sterile
- Bulb Aspirator Syringe. - Supplied in sealed pack - Sterile.
- Latex Free Bulb aspirator Syringe - Essential part of any Whelping kit.
- Quickly and hygienically removes fluids from mouth and throat of puppies & Kittens.
- Nasal aspirator to clear nose in babies.
- Can be used to wash ulcers.
| Needle destruction destroys the needle immediately following its use. Needle destruction are an absolute necessity in developing parts of the world to prevent the reuse of needles and the spread of bloodborne pathogens. They are NOT a good alternative, however, for hospital use in the developed parts of the world. Needle destruction are products that bend, cut, or destroy the needle. This are distinctly different from needle destroyer that send an arc of electricity to vaporize and melt the needle.
Features:
- Well built
- Easy to maintain
- Having a rubbish drawer with alarm function, this is our most popular model of Syringe Destroyer for use in labs, pharma, universities and doctors clinics
- With its low factory-direct price and excellent quality, its a great addition to add to any medical industry or university office that wants to ensure the safety and legal compliance of its operations
Specifications:
- Short Name: Needle destruction / Needle Destroyer
- Working Noise: ≤50 decibel
- Superheating Sanitization Temperature: 95 deg C
- Working Time: Can completely melt and destroy needle and neck of syringe in 5 seconds
- Working Noise: ≤50 decibel
- Dimensions: Approx. 38cm x 29cm x 28cm
- Power: AC 110V or 220V
|
Material |
Stainless Steel |
Height Adjustable |
Yes |
Number of Wheel |
4 |
Height |
3-4 Feet |
| Used for Clinical Diagnostics.
- Test Method: Dry Strip color-developing method
- Test Principle: Dual wavelength reflectance photometry
- Light Source: Cold Lamp with high brightness and long lifetime
- Test System: Color-indentify system with high sensitivity and repeatability
- Wavelength: 520nm, 640nm, 660nm
- Throughput: 120 Strips/Hour
- Test Mode: Single and continuous test mode are selectable
- Test Slot: Using sliding Slot, Easy to clean and replace, lower the carryover
- Waste Collection: Waste urine and waste strips can be collected automatically
- Test Strip: Use GENIUS original strips only
- Display: LCD with high brightness and resolution
- Language: Customizable language software
- Memory: Save 2000 samples results, and auto recover the results when power off during working
- Interface: RS-232 serial port, can be connected to external printer and computer Printer: Inner thermal printer, can be connected to external printer
- Report format: Half quantitative and qualitative, report the color and turbidity is available
- Result unit: SI unit and routine unit are selectable
- Status Check: Auto-check the status during power on and off, auto-indentify the alarm
- Working Environment: Temperature10℃~30℃; Humidity: 20%RH~80%RH
- Power: 100-240V, Auto adapt according to the input voltage
- Consumption: ≤80VA
- Quality System: Certified by TUV and CMD
| LDF series waste incinerator adopt gasification combustion that can make garbage more sufficient burning. Waste incinerator is a kind of machine that possess the own intellectual property, features unique and advanced merits with compact size, high burning efficiency, reasonable burning technology, high degree of non-harm etc, it is an ideal choice for waste treatment of hospital, hotels, various stations and industries.
Features:
- Both gas-motivated and oil-motivated are all can be preferred according to customers' needs.
- Gasified incineration is used for burning syringe, paper waste, bandage, absorbent cotton and other medical wastes.
- Daily waste can be burned once by gasified incineration.
- Gasified incineration, mixed incineration and burnout treatment ensures low emission standard of dust (lower than International standard).
- Totally enclosed operation is suitable for treating infectious waste to avoid secondary pollution.
Advantages:
- Long lifetime
- Totally enclosed operation
- Suitable for treating infectious waste
- Avoid secondary pollution
- Simple operation
- Smokeless and no harmful to environment
- Continuously and fully burning
- Simple operation
Incinerator LDF-100 Parameter:
Applicable hospital size |
250 beds |
Max. Burning Ability |
100 kg/time |
Size of the Burner |
1.5m×1.15m×3m |
Volume of the Burner |
Gasification room 0.5m3 |
second buming room 0.3m3 |
Chamber Temperature |
First chamber:600℃-700℃; |
second chamber:300℃-1300℃ |
|
Ash residue |
≤5% |
Size of the filling entrance |
620mm×800mm |
Chimney |
Hight 10m,Out-radiusØ300 |
Blower |
0.37kw |
Auxiliary machine |
Power0.11kw,fuel consumption4-10kg/h |
Re-burning machine |
Power0.11kw,fuel consumption6-10kg/h |
Running voltage |
220V or 380V |
Weight |
About 4600(kg) |
Flue&Gas Emission Standards:
OrdinalNumber |
Refuse name |
Measuring unit |
GB18484-2001 |
1 |
Blackness of Flue |
Ringelmann class |
1 |
|
|
|
Gas |
|
|
|
2 |
Smoke&Dust |
mg/m3 |
100 |
|
3 |
CO |
mg/m3 |
100 |
|
4 |
SO2 |
mg/m3 |
400 |
|
5 |
HF |
mg/m3 |
9.0 |
|
6 |
HCL |
mg/m3 |
100 |
|
7 |
NO2 |
mg/m3 |
500 |
Click Here To Download Catalogue |
Reviews
There are no reviews yet.