1) Output power factor: PF1.0
2) Rack/Tower Convertiable Design with manual roatatable LCD Screen.
3) Input voltate:110-300Vac
4) Output voltage:208/220/230/240Vac
5) Transfer time: AC to DC mode 0ms ; DC to bypass mode 4ms.
6) Output frequency: 50Hz/60Hz auto adjusted.
7)ECO Power Mode, High Efficiency up to 98.5%
8) Interferface: 1*USB, 1*RS232, 1*EPO, 1*SNMP card slot ( SNMP card needs to be purchased separately).
9)Protection: high/low voltage, over load, short circuit protection.
Technical Specifications
Model
RM 1K
RM1KL
RM 2K
RM 2KL
RM 3K
RM 3KL
RM 6K
RM 6KL
RM 10K
RM 10KL
Rated Capacity
1KVA/1KW
2KVA/2KW
3KVN/3KW
6KVA/6KW
10KVA/10KW
INPUT
Input Formats
L+N+PE
Rated Input Voltage
208/220/230/240 VAC
Voltage Range
110-300VAC (110-176VAC,280-300VAC Power Limited)
Frequency Range
50/60Hz±6Hz,±10Hz(Setable)
Input Power Factor
>0.99
Input Harmonic Distortion
<1%THD(Linear Load),<5%THD(Non-linear Load)PF=0.8
<5%THD(Linear Load),<8%THD(Non-linear Load)PF=0.8
OUTPUT
Output Formats
L+N+PE
Output Voltage
208 /220/230/240 VAC
Output Accuracy
±1%
Output Frequency
AC Mode:Same as AC,Battery Mode:50160Hz±1%
Output Harmonic Distortion
<1%THD(Linear Load),<3%THD(Non-linear Load)PF=0.8
<2%THD(Linear Load),<5%THD(Non-linear Load)PF=0.8
Output Power Factor
1.0
Transfer Time
AC Mode to Battery Mode:0ms,Inverter Mode to Bypass Mode:4ms
Delivery & Availability:Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability:Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Features:
60KW single power module in 3U
N+1or N+X parallel redundancy for power guarantee
Supports horizontal expansion by 1+1 cabinet paralleloperation.
Hot-swappable modular design decreases MTTR
High scalability
Built-in maintenance bypass switch for easy maintenance without interruptible
High efficiency double conversion online UPS
Flexible battery configuration and adjustable charging current
High overload capability
Power walk-in function
Built-in dynamic password protection
Built-in ultra communication slot
Delivery & Availability:Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Features:
Wide AC input voltage range 85~265Vac.
Inbuilt 4* 2600mah lithium battery to support longer power supply for loads.
DC output interfaces support USB (5V) /9V/12V/ 15V/24V (POE)
Ethernet power supply: one network cable can transmit data and electric
power at the same time.
Over-charging, Over-discharging and Short Circuit protection
Delivery & Availability:Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Features:
True Double conversion Technology
DSP digital control technology enable UPS more stable performance.
Three-level inverter technology
Active High input power factor correction technology (PFC)
Wide Input Voltage Frequency Range& Strong load capacity
Zero power switch delay
Compatible with Generators
Wide input voltage and frequency range can effectively isolate the harmful waves into power by the generator and provide pure,safe and stable power supply.
Support intelligent monitoring
Fully support remote intelligent monitoring with flexibility in choice of USB cards . AS400 cards , SNMP cards , RS485 cards
Delivery & Availability:Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability:Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Features:
1) Output power factor: PF1.0
2) Rack/Tower Convertiable Design with manual roatatable LCD Screen.
3) Input voltate:110-300Vac
4) Output voltage:208/220/230/240Vac
5) Transfer time: AC to DC mode 0ms ; DC to bypass mode 4ms.
6) Output frequency: 50Hz/60Hz auto adjusted.
7)ECO Power Mode, High Efficiency up to 98.5%
8) Interferface: 1*USB, 1*RS232, 1*EPO, 1*SNMP card slot ( SNMP card needs to be purchased separately).
9)Protection: high/low voltage, over load, short circuit protection.
Technical Specifications
Model
RM 1K
RM1KL
RM 2K
RM 2KL
RM 3K
RM 3KL
RM 6K
RM 6KL
RM 10K
RM 10KL
Rated Capacity
1KVA/1KW
2KVA/2KW
3KVN/3KW
6KVA/6KW
10KVA/10KW
INPUT
Input Formats
L+N+PE
Rated Input Voltage
208/220/230/240 VAC
Voltage Range
110-300VAC (110-176VAC,280-300VAC Power Limited)
Frequency Range
50/60Hz±6Hz,±10Hz(Setable)
Input Power Factor
>0.99
Input Harmonic Distortion
<1%THD(Linear Load),<5%THD(Non-linear Load)PF=0.8
<5%THD(Linear Load),<8%THD(Non-linear Load)PF=0.8
OUTPUT
Output Formats
L+N+PE
Output Voltage
208 /220/230/240 VAC
Output Accuracy
±1%
Output Frequency
AC Mode:Same as AC,Battery Mode:50160Hz±1%
Output Harmonic Distortion
<1%THD(Linear Load),<3%THD(Non-linear Load)PF=0.8
<2%THD(Linear Load),<5%THD(Non-linear Load)PF=0.8
Output Power Factor
1.0
Transfer Time
AC Mode to Battery Mode:0ms,Inverter Mode to Bypass Mode:4ms
1 hour for ≤110%,10 mins for 111%~125%,1 min for 126%~150% and 200ms for >150%
Haronic Distortion
≤2% THD (Linear Load); ≤4% THD (Non-linear Load)
Eficiency
96%
BATTERY / CHARGER
Nominal Voltage
’+/- 192V~+/- 240V(Selectable)
Maximum Voltage
’+/- 240V (12V×40 PCS)
Minimum Voltage
‘+/-192V (12V×32 PCS)
Floating Charge Voltage
2.28V/Cell (2.25~2.33 Selectable)
Boost Charging Voltage
2.35V/Cell
Temperature Compensation
Yes
Maximum Charging Current
(Per Power Module)
18A(Adjustable)
PHYSICAL
Cabinet Dimension (DxWxH)mm
1100x600x1475
1100x600x1475
1100x600x2010
1100×600×2010
1065x1000x2000
1065×1000×2000
Net Weight (Kg)
308
352
516
654
932
1020
Power Module (PM-60) Net Weight
44KGS
ENVIRONMENT
Operating Temperature
0~40℃
Relative Humidity
0~95% non-condensing
Altitude*
<1000m for Nominal power
IP Protection
IP 20
MANAGEMENT
Smart RS-232/USB
Supports Windows⑧ Family, Linux and MAC
Optional SNMP
Power management from SNMP manager and web browser
STANDARDS
Safety
IEC/EN62040-1
EMC
IEC/EN 62040-2 Category C3
Features:
Wide AC input voltage range 85~265Vac.
Inbuilt 4* 2600mah lithium battery to support longer power supply for loads.
DC output interfaces support USB (5V) /9V/12V/ 15V/24V (POE)
Ethernet power supply: one network cable can transmit data and electric
power at the same time.
Over-charging, Over-discharging and Short Circuit protection
Specifications
Model
DC 1018P
DC 1036P
INPUT
Input Voltage
85 – 265Vac
Output
DC Output Voltage
5V 2A
5V 2A
USB 2A
USB 2A
9V 1A
9V 1A
12V 1A
12V 1A
15V/24V(POE) 0.5A
15V/24V(POE) 0.5A
18W
36W
BATTERY
Battery Type
Lithium Battery
Capacity of Battery
2600mAh * 4
PROTECTION
Protect
Over-charging, Over-discharging and Short Circuit
ENVIRNMENT
Operation Temperature
0°C – 40°C
Noise Level
Less than 40dB
Dimension(mm)
160 * 105 * 33
Net Weight(kg)
0.40
0.42
Features:
True Double conversion Technology
DSP digital control technology enable UPS more stable performance.
Three-level inverter technology
Active High input power factor correction technology (PFC)
Wide Input Voltage Frequency Range& Strong load capacity
Zero power switch delay
Compatible with Generators
Wide input voltage and frequency range can effectively isolate the harmful waves into power by the generator and provide pure,safe and stable power supply.
Support intelligent monitoring
Fully support remote intelligent monitoring with flexibility in choice of USB cards . AS400 cards , SNMP cards , RS485 cards
Applications:
Mammogram
Ultrasound Equipments
Radiology rooms
Technical Specifications
Model
VT1K
VT1KL
VT2K
VT2KL
VT3K
VT3KL
Rated power
1KVA/900KW
2KVA/1.8KW
3KVA/2.7KW
Input
Voltage range
90~285Vac L+N+G
Frequency range
40-70Hz(Adjustable)
Input power factor
>0.99
Output
Rated voltage and precision
220Vac (1±2% ) L+N+G
Output frequency
46-54Hz Synchronous mains power; 50Hz( Frequency Range 40-46Hz ~54-60Hz);50Hz(Battery mode)
Rated Current
4.5A
9.1A
13.6A
Output power factor
0.9
Output harmonic
≤4%
Crest factor
3:1
Inverter overload capacity
105%±5%< Load<125%±5% : 50s transfer to bypass
125% ±5% < Load<150 % ±5 % : 25s transfer to bypass
Load > 150 % ± 5 %: 300s transfer to bypass
Transfer time
0ms
Efficiency
≥85%
Battery
Rated voltage
24Vdc
36Vdc
48Vdc
72Vdc
72Vdc
96Vdc
Battery Numbers
2
3
4
6
6
8
Charge current
1A
6.5A
1A
5.5A
1A
5.5A
Size(LXWXH)mm
350*144*230
425*190*328
Net Weight(KG)
9.5kg
6kg
18.5kg
10kg
23.5kg
11kg
Operating temperature
0°C 〜40°C
Operating humidity
20% 〜95%
Noise
≤50dB
Description
HIGH INTELLIGENCE AND RELIABLE POWER SUPPLYIGBT Technology
Full microprocessor control with no-break static and manual bypasses.
Online double conversion technology (VFl) with isolation transformer on theinverter output.
Extremely high short-circuit current to ensure compatibility with the most diffificult transformer applications (lighting, drives and industrial processes) and an isolation transformer on the inverter output.
Compatibled with Watch & Save 3000 software as standard and can be remotely monitored using the Power NetGuard system from anywhere in the world.
SIMPLE TO INSTALL
Capability to install the UPS into any distribution system(neutral not required on rectifier input).
Capability to separate the rectifier/bypass power networks and to power them from two separate sources, without Galvanic isolation(Necessary on UPS without an output transformer
MAXIMUM BATTERY CARE
Battery deep discharge protection;
Temperature compensating charger;
Built-in automatic and manual battery test feature.
OTHER CHARACTERISTICS
0.8/0.9 power factor suitable for powering ICT and lndustrial loads.
BACK FEED protection: to avoid energy feeding back into the mains supply cause a fault occur.
MAXIMUM RELIABILITY AND AVAILABILITY
Connect up to 6 units in parallel or N+1 redundancy, even of different power ratings.
The UPS continue to work in parallel even if one of theinterconnecting communication cables is disconnected(CLOSED LOOP)
LOW CONSUMPTION LEVELS
LF31 Series UPS can achieve efficiencies >98% thanks to selectable Economy Mode which can be used in stable electrical environments to provide power supply continuity when the mains fail.
ADVANCE COMMUNICATION:
RS485/RS232/Dry Contact/SNMP(Optional)
Specifications
Model
10KVA
15KVA
20KVA
30KVA
40KVA
60KVA
80KVA
100KVA
Capacity
8KW
12 KW
16 KW
24 KW
32 KW
48 KW
64 KW
80 KW
INPUT
Rated voltage
380/400/415 VAC Three-phase
Voltage range
±20%
Frequency range
45-65Hz
Power factor
>0.92 with harmonic filter
Current harmonic distortion
<5% with harmonic filter
Soft Start
0 -100% in 10″
BYPASS INPUT
Rated voltage
230VAC Single Phase
Permitted voltage range
±15% (selectable from ±10% to ±25% from front panel)
Reviews