Sugentech Inclix Troponin I Test Kit

Ask for Price$0.00

Shipped From Abroad

  • INCLIX™ Troponin I quantitatively measures troponin I concentration in whole blood, serum or plasma. using the INCLIX™ analyzer. For in vitro diagnostic use only.

Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.

SF1033560084-230
Brands:: Sugentech
Brands

Description

  • INCLIX™ Troponin I quantitatively measures troponin I concentration in whole blood, serum or plasma. using the INCLIX™ analyzer. For in vitro diagnostic use only.
  • Cardiac troponin I (Tn I) is a protein found in myocardial muscle and the most sensitive biomarker for detection of acute myocardial infarction (AMI).The concentration of Tn I in the healthy human is below about 0.5 ng/ml and the level of Tn I is increased within 4-6 hours after the onset of chest pain. After cardiac injury occurs, peak in approximately 8 to 28 hours, and remain elevated for 3 to 10 days following AMI. The Tn I test is well known to be an important prognostic indicator of heart disease.
  • The Tn I Test is based on immunochromatography technology. When the sample is loaded to the device, the detection antibody which is conjugated with the colloidal gold in the dried pad binds to Tn I and flows through the membrane. The detection antibody-gold conjugate and Tn I move to the test line area and are accumulated by the capture antibody immobilized on the membrane. This leads to the generation of a reddish colored band. The intensity of the band depends on quantity of Tn I molecules and is analyzed by INCLIX™ analyzer for quantitative readout

Reviews

There are no reviews yet.

Be the first to review “Sugentech Inclix Troponin I Test Kit”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsSugentech Inclix Troponin I Test Kit removeSkyla HB1 POC Clinical Chemistry Auto Analyzer removeABAXIS HD Video Microscope removeDiscover 5 Panel Cup with Adulterants Per Pack removePlastic Urine Container Per Pack removeAutomatic Pipette remove
NameSugentech Inclix Troponin I Test Kit removeSkyla HB1 POC Clinical Chemistry Auto Analyzer removeABAXIS HD Video Microscope removeDiscover 5 Panel Cup with Adulterants Per Pack removePlastic Urine Container Per Pack removeAutomatic Pipette remove
ImageSugentech Inclix Troponin I Test KitDrug Test Cup
SKUSF1033560084-230SF1033560060-1SF1033560084-32SF1033560084-23SF1033560084-106SF1033560084-130
Rating
Price

Ask for Price$0.00

Ask for Price$0.00

Ask for Price$0.00

Ask for Price$0.00

$8.20

Ask for Price$0.00

Stock

Out of stock

AvailabilityOut of stock
Add to cart

DescriptionShipped From Abroad
  • INCLIX™ Troponin I quantitatively measures troponin I concentration in whole blood, serum or plasma. using the INCLIX™ analyzer. For in vitro diagnostic use only.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad The skyla HB1 Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results. The portable design of the clinical chemistry analyzer utilizes precision photometric measurement technology, combined with the single-use disposable reagent discs. The reagent disc contains a set of dry assay reagents that are used in the quantitative testing of various biomarkers in the blood sample. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In Stock The HDmicroscope is a versatile digital imaging solution that can be used for multiple tasks in day-to-day slide microscopy, digital image capture, and real-time imaging during live pathology consults or client discussions. The microscopy camera & monitor system is perfect for single use, teaching or group presentations without the need for a computer set-up.

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
The Discover Cup is an all-in-one drug of abuse test cup. The strips are self-contained and the entire cup is tamper resistant. Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • Total Volume: 60mL.
  • Specimen Container, Leak-proof, Ideal for Pathology/Histology/Cytology reagent pre-filling sample preparation.
  • Made of premium PP material, it is durable for usage.
  • Some measurements can be used to not only use urine samples, it can also be used for other liquids.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
This Automatic Pipette will help you get your lab up and running in no time—at a great price! Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
  • INCLIX™ Troponin I quantitatively measures troponin I concentration in whole blood, serum or plasma. using the INCLIX™ analyzer. For in vitro diagnostic use only.
  • Cardiac troponin I (Tn I) is a protein found in myocardial muscle and the most sensitive biomarker for detection of acute myocardial infarction (AMI).The concentration of Tn I in the healthy human is below about 0.5 ng/ml and the level of Tn I is increased within 4-6 hours after the onset of chest pain. After cardiac injury occurs, peak in approximately 8 to 28 hours, and remain elevated for 3 to 10 days following AMI. The Tn I test is well known to be an important prognostic indicator of heart disease.
  • The Tn I Test is based on immunochromatography technology. When the sample is loaded to the device, the detection antibody which is conjugated with the colloidal gold in the dried pad binds to Tn I and flows through the membrane. The detection antibody-gold conjugate and Tn I move to the test line area and are accumulated by the capture antibody immobilized on the membrane. This leads to the generation of a reddish colored band. The intensity of the band depends on quantity of Tn I molecules and is analyzed by INCLIX™ analyzer for quantitative readout
Skyla HB1 Clinical Chemistry Analyzer utilizes precision photometric measurement technology, combined with the single-use disposable reagent discs. The reagent disc contains a set of dry assay reagents that are used in the quantitative testing of various biomarkers in the blood sample. HB1 provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results. Only needs 200µl of blood (whole blood, serum or plasma is accepted.) and no sample preparation is required. All steps are designed automatically from checking the validity of reagent discs and cartridges to printing the results. Over 30 test parameters are allowed with fast analysis and results in 15 minutes. Internal Quality Control (IQC) with self-calibration of optical system, chemicals stability and interference alerts functions monitor and ensure the results with high accuracy. Available Test Panels
  • Renal Function - BUN, CREA eGFR
  • Liver Function - ALB, TP, ALP, ALT, AST, TBIL, DBIL, GGT, LDH A/G#, GLOB#, IBIL
  • Lipid Metabolism - TG, TC, HDL LDL#, VLDL
  • Pancreatitis Markers - AMY, LIPA
  • Carbohydrate Metabolism and Others - GLU , CPK, UA, LAC
  • Inflammatory Markers - CRP
  • Electrolyte - Na, K, Cl, Ca, PHOS, Mg, tCO2
SPECIFICATION Principle
  • Colormetric System : LEDs 340nm~940nm wavelength
Sample & Panel
  • Test Profiles : Panels
  • Measurement Time - Panel: up to 15 tests/ 15 min
  • Sample Type & Volume : 200 μl whole blood (PCV<60%), plasma, serum 
Device
  • User Interface : 5 inch color LCD touch screen
  • Internal Memory : Store up to 50,000 analysis results
  • Printer : Built in thermal printer or external USB printer (PCL 3GUI)
  • USB Socket : USB type A (Host) for external USB Printer, USB flash drive (FAT) or external barcode scanner
  • Data transmission to PC : RS232 serial port or RJ45 (LAN)
  • Dimensions : 233 (W) X 285 (D) X 300 (H) mm
  • Weight : 5.5 kg
Operating Condition
  • Temperature / Humidity : 10 to 32˚C / 5 to 90 %
 
Click Here To Download Catalogue
The HDmicroscope is a versatile digital imaging solution that can be used for multiple tasks in day-to-day slide microscopy, digital image capture, and real-time imaging during live pathology consults or client discussions. The microscopy camera & monitor system is perfect for single use, teaching or group presentations without the need for a computer set-up. Feature
  • HD quality images
Super bright daylight white LED and enhanced color correction provides stunning high-resolution images that can be digitally captured and archived for patient files and consultation.
  • Fluorescence imaging
Highly adjustable exposure time and gain value from built-in camera make HDmicroscope optimal for fluorescent imaging.
  • Standalone system
The external HDMI port allows you to connect directly to a HD monitor for live/real time viewing. You can also capture and save images to an SD card, all without being connected to a computer.
  • Easy to use
With parfocal lenses, auto-gain, and exposure, a change in magnification delivers a perfect picture every time.
  • Live HD video
Uncompressed full 1080p 60fps video for seamless live viewing, recording, or streaming without any lag time.
  • Intuitive control
Control the camera with a click of a mouse rather than searching for buttons on the camera.
  • Trinocular design
The trinocular eye tube accommodates the HD imaging system to create a complete full-screen or split-screen digital experience.
  • Fast
With 60fps HDMI and 30fps USB 2.0 data transfer at 1920x1080 resolution, the Excelis HD camera is one of the fastest HD 1080p cameras on the market today.   Technical Specification
  • Dimensions:75 (with screen) x 11.00 (with screen) x 14.50 inches (HxWxD)
  • Head: Siedentopf binocular viewing head, inclined 30°
  • Nosepiece: Reversed quadruple nosepiece
  • Focusing system: Coaxial coarse & fine focusing system, with stop limit & tension adjustment. Travel range: 25mm. Fine focusing precision: 0.002mm
  • Condenser: Built-in Koehler illuminator systems, pre-centered. Iris diaphragm Koehler illuminator condenser and mirror optional
  • Optical system: AIS E-Plan optical system
  • Eyepiece: PL10X/20mm diopter adjustable eyepiece, 20mm field of view
  • Objective: AIS E-Plan achromat objective (4X, 10X, 40X, 100X)
  • Stage: Built in low position coaxial control mechanical stage, area 140x132mm, moving range 76x50mm
  • Illuminator: Universal power supply 90~240V voltage, 3W LED light with variable intensity control
 
Click Here To Download Catalogue
All-in-One Design
FDA 510K & CLIA Waived 99% Accurate Results in as little as 1 minute 24 Month Shelf Life from Date of Manufacture Secure, seal and send to lab for confirmation Built in temperature strip Available to test up to 14 substances Adulterants available
 
 
  • Total Volume: 60mL.
  • Specimen Container, Leak-proof, Ideal for Pathology/Histology/Cytology reagent pre-filling sample preparation.
  • Made of premium PP material, it is durable for usage.
  • Some measurements can be used to not only use urine samples, it can also be used for other liquids.
This Automatic Pipette will help you get your lab up and running in no time—at a great price! Features:
  • Lowest operation and tip ejection forces
  • Fully autoclavable
  • Ultra light weight with space-age materials
  • Secondary adjustment option for various liquid classes
  • Spring loaded tip con
  • For transferring molecular samples and PCR mix solutions.
  • One set is for DNA work and the other for RNA work. Each with the following specs
  • Light weight, traditional tip shaft, and will fit all generic brands of tips
  • Equal to or better than accuracy and precision compared to ISO 8655, so results can be trusted.
  • Easy and quick volume adjustment with or without gloves. Foolproof volume lock prevents accidental volume changes.
  • Low maintenance and autoclavable 121° for at least 20 minutes
  • Quick release
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information