Hersill Genesis Anaesthetic Machine
Ask for Price$0.00
Shipped from Abroad
The Genesis anaesthesia workstations meet your most ambitious requirements. They stand out for their lung protective ventilation.
Application Field: Neonates, Pediatrics & Adults
Ventilation Modes: Volume controlled (VC), Pressure controlled (PC), Adaptive Pressure with Volume Guaranteed (APVG) & Pressure Support Ventilation (PSV)
Delivery & Availability:
Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
The Genesis anaesthesia workstations meet your most ambitious requirements. They stand out for their lung protective ventilation, accuracy and performance, cost saving, design and ergonomics, safety and versatility.
TECHNICAL SPECIFICATION
OPERATING DATA
- Weight – 105 kg
- Dimensions – 92 cm Wide x 68 cm Deep x 139 cm High (93 cm to the table surface)
- Packaging Dimensions – 105 cm Wide x 75 cm Deep x 160 cm High
- Operating voltage supply – 110 to 240 V~, 47 to 63 Hz (12 to 6 A)
- Power input – 120 W typically (max. 1.2 kW with auxiliary outlets used)
- Battery autonomy – 90 min typically
- Auxiliary power outlets – 4, with automatic protection
- O2, N2O and Air supply – 2.7 to 6.9 bar (39.1 to 100 psi)
- Screen – TFT 18.5″ (47 cm) projected capacitive touchscreen
- Protection class – Class I, gas analyser type BF defibrillation proof
- Classification – Class II b
- Storage – One front drawer with self-brake system and two back cabinets with door
- Lighting – LED bar below the screen controlled from the touchscreen
- Auxiliary integrated systems – Auxiliary 02 flow meter (0-15 L/min), Auxiliary 02 suppy valve (NF standard) and Suction device
- Communication ports – 1 x RS-232, 2 x USB, 1 x LAN Ethernet
Fresh Gases (02, N20 and Air, electronically controlled)
- Fresh gas flow – 0 and 0.1 to 18 L/min 02/N20/Air
- Accuracy – 0.1 to 0.5 L/min = ±0.05 L/min; 0.5 to 18 L/min = ±10 %
- 02 concentration – 21 to 100% vol. with Air, 25 to 100% with N20 (minimum 200 ml/min 02)
- 02 Safety fresh gas (backup) – 0-0.2-0.4-0.7-1-1.5- 2- 3- 4- 6- 8-10-12-15 L/min 02
- 02 flush (+02) – 40 L/min standard (adjustable 25 – 75 L/min upon requirement)
Breathing System (CABS)
- Autoclavable – 134 °C
- Weight of breathing system – 9.8 kg
- C02 absorber volume – 1.5 L
- Leakage – < 150 mL/min (at 30 hPa)
- Pressure limiting valve APL – 0 to 70 hPa
- Pressure relief valve – 125 hPa
- Vacuum safety valve – 0.3 hPa
- resistance at 60L/min – 5.80 hPa
- resistance at 60L/min – 2.90 hPa
- resistance at 30L/min – 3.55 hPa
- resistance at 30L/min – 0.89 hPa
- Internal Compliance at 30 hPa – 15 mL
VENTILATOR
Operation / Ventilation Modes
Volume controlled (VC) modes:
- Volume Controlled Ventilation (VCV)
- VC Synchronized Intermittent Mandatory Ventilation (VC-SIMV)
- VC-SIMV with Pressure Support (VC-SIMV-PS) *
Pressure controlled (PC) modes:
- Pressure Controlled Ventilation (PCV)
- PC Synchronized Intermittent Mandatory (PC-SIMV)
- PC-SIMV with Pressure Support (PC-SIMV-PS) *
Adaptive Pressure with Volume Guaranteed (APVG) modes (other trade names: Autoflow,PCVR, PRVC, AVAPS, VC+)
- Adaptive Pressure with Volume Guaranteed (APVG) *
- APVG Synchronized Intermittent Mandatory (APVG-SIMV) *
- APVG -SIMV with Pressure Support (APVG-SIMV-PS) *
Pressure Support Ventilation (PSV) *
- (other trade names: PS, ASB, SPS, IPS)
Non-mechanical Operation / Ventilation Modes
- Manual ventilation through the CABS system (Auto/Manual software controlled)
- Spontaneous ventilation either through the bellows (auto mode) or through the bag
- (manual mode) Manual ventilation through the external fresh gas outlet for non-rebreathing systems (Bain, Mapleson, …)
Application field: Neonates, Pediatrics & Adults
- Tidal volume – 5 to 1500 mL
- Inspiratory pressure – 0 to 68 hPa
- Ventilation frequency - 3 to 120/min
- Inspiratory time – 0.05 to 16.6s
- l:E ratio – 5:1 to 1:8
- Inspiratory pause – 0 to 60%
- Inspiratory flow – max. 150 L/min
- PEEP – 0 to 30 hPa
- Flow trigger – 0.2 to 15 L/min
- Pressure support – 5 to 50 hPa
- Ramp time – 0.1 to 2 s
- Maximum pressure – 0 to 68 hPa
MONITORING
- 5″ (47 cm) projected capacitive touchscreen, supported on a 360° rotating and 2 axis tilting arm.
- Measurements displayed: Peak pressure; Plateau pressure; Mean pressure; Expiratory minute ventilation; Expiratory tidal volume; Inspiratory tidal volume; Expiratory volumeter; Breathing rate; Compliance and Resistance (in VC modes); Patient info (age, weight, MAC, Class ASA); Connected sensors; Battery status; Power supply status; Gases supply pressures for 02, N20 and Air; Inspiratory and expiratory concentration of 02, N20, C02 and Anaesthetic gas*
- Parametres charted as curves (up to 3 simultaneously): Airway pressure; Expiratory flow; Inspiratory flow; Volume; Fresh gases (Rotstyle); Concentration of 02, N20, C02 and Anaesthetic gas*; Trends: Minute volume, MAC and gases (02, N20, C02 and Anaesthetic gas).
- Display for the performance of the hospital Anaesthetic Gas Scavenging System (AGSS).
- Configurable interface: bright/dark, multi-language.
- Loops (up to 2 simultaneously): Volume-Pressure, Flow-Volume, Pressure-Flow, C02-Volume.
- Fresh gas virtual rotameters for 02, N20, Air. * C02, N20 and Anaesthetic gas monitoring with the accessory multigas analyzer main-stream or side-stream; 02 real-time monitoring via paramagnetic
Click Here To Download Catalogue
Quick Comparison
Hersill Genesis Anaesthetic Machine remove | OPTIKA B-382PL-ALC Binocular Brightfeld Microscope remove | Nihon Kohden Neuropack S3 Electromyogram (EMG) Machine remove | SIGNERS SUPiA X-ray Digitizer ( CR Scanner) remove | Siare Morpheus LT Anaesthetic Machine remove | Feeding Table remove | |||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Name | Hersill Genesis Anaesthetic Machine remove | OPTIKA B-382PL-ALC Binocular Brightfeld Microscope remove | Nihon Kohden Neuropack S3 Electromyogram (EMG) Machine remove | SIGNERS SUPiA X-ray Digitizer ( CR Scanner) remove | Siare Morpheus LT Anaesthetic Machine remove | Feeding Table remove | ||||||||||||||||||||||||
Image | ||||||||||||||||||||||||||||||
SKU | SF1033560450-1 | SF1033560098-13 | SF1033560020-3 | SF1033560050-01 | SF1033560101- 3 | SF1033560084-195 | ||||||||||||||||||||||||
Rating | ||||||||||||||||||||||||||||||
Price | Ask for Price | Ask for Price | Ask for Price | Ask for Price | Ask for Price | $31.50 | ||||||||||||||||||||||||
Stock | ||||||||||||||||||||||||||||||
Availability | ||||||||||||||||||||||||||||||
Add to cart | ||||||||||||||||||||||||||||||
Description | Shipped from Abroad The Genesis anaesthesia workstations meet your most ambitious requirements. They stand out for their lung protective ventilation. Application Field: Neonates, Pediatrics & Adults Ventilation Modes: Volume controlled (VC), Pressure controlled (PC), Adaptive Pressure with Volume Guaranteed (APVG) & Pressure Support Ventilation (PSV) Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped from Abroad The OPTIKA B-380 is an educational and laboratory microscope for routine applications. Dye-cast frame, with high stability and ergonomy, for transmitted light observation. Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped from abroad The Neuropack S3 combines Nihon Kohden’s gold-standard amplifiers with time-saving and easy-to-use clinical software, bringing neurodiagnostic labs a feature-rich system that provides cleaner, easier and faster data. The foundation of effective neurodiagnostic testing is a system that can provide a full complement of neurodiagnostic tests while also offering the quality needed to analyze and monitor nervous system function. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped from Abroad SUPiA made by Signers offers such a better clinic environment with no chemicals, ideal space, high-resolution image quality, and affordability. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped from Abroad he Morpheus LT is an anesthetic machine suitable for treatment of adults, children and new-borns. lt is provided with a mechanical 3-gas flowmeters group and a group tor rapid connection of two vaporizers in line and it is supplied with an advanced manual ventilation system, APL system, or AUX system with traditional To-and-Fro valve switched on and off automatically by ventilator. The unit frame is made tor 30% of light alloy and for 70% of fullyrecyclable plastic materiai. Thanks to the materiai used, the Morpheus has a total weight of less than 80 kgs. Delivery & Availability: Typically 15 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
| ||||||||||||||||||||||||
Content | The Genesis anaesthesia workstations meet your most ambitious requirements. They stand out for their lung protective ventilation, accuracy and performance, cost saving, design and ergonomics, safety and versatility.
TECHNICAL SPECIFICATION
OPERATING DATA
Click Here To Download Catalogue | Observation mode: Brightfield.
Head: Binocular, 30° inclined, 360° rotating (when ALC cable is unplugged).
Interpupillary distance: Adjustable between 48 and 75 mm.
Dioptric adjustment: On the left eyepiece tube.
Eyepieces: WF10x/20 mm, high eye-point and secured by screw.
Nosepiece: Quintuple revolving nosepiece, rotation on ball bearings.
Objectives:
N-PLAN 4x/0.10
N-PLAN 10x/0.25
N-PLAN 40x/0.65
N-PLAN 100x/1.25 (Oil/Water)
All with anti-fungus treatment.
Specimen stage: Double layer rackless mechanical stage, 150×139 mm, 75×33 mm X-Y range.
Focusing: Coaxial coarse (adjustable tension) and fine focusing mechanism with limit stop to prevent the contact between objective and specimen. Condenser: Abbe N.A. 1.25, with objective-coded iris diaphragm, focusable and centerable.
Illumination (Fixed Koehler type): X-LED3 with white 3.6 W LED (6,300K) and brightness control. ALC system. Multi-plug 100-240Vac/6Vdc external power supply.
Click Here To Download Catalogue | The Neuropack S3 combines Nihon Kohden’s gold-standard amplifiers with time-saving and easy-to-use clinical software, bringing neurodiagnostic labs a feature-rich system that provides cleaner, easier and faster data. The foundation of effective neurodiagnostic testing is a system that can provide a full complement of neurodiagnostic tests while also offering the quality needed to analyze and monitor nervous system function.
Features:
Click Here To Download Catalogue | SUPiA X-ray Digitizer made by Signers offers such a better clinic environment with no chemicals, ideal space, high-resolution image quality, and affordability
FEATURE
Rigid Type
• No damage or scratch on image plates during scanning & erasing
• Scanning & Erasing without a roller
• No cut-off image during winter and cold period
Durability
• Extremely simple structure design
• Strong aluminum base plate
• Flip covers preventing dust from inside scanner
Barcode System
• Automatically recognising cassette sizes(14x17", 10x12", 18x24cm) by barcode reader
Compact & lightweight design
Click Here To Download Catalogue | The Morpheus LT is an anesthetic machine suitable for treatment of adults, children and new-borns. lt is provided with a mechanical 3-gas flowmeters group and a group tor rapid connection of two vaporizers in line and it is supplied with an advanced manual ventilation system, APL system, or AUX system with traditional To-and-Fro valve switched on and off automatically by ventilator. The unit frame is made tor 30% of light alloy and for 70% of fullyrecyclable plastic materiai. Thanks to the materiai used, the Morpheus has a total weight of less than 80 kgs.
LUNG VENTILATOR
The ventilator works by a microprocessor electronic control system with a simple and intuitive interface, which allows the anesthetist to operate in a clear and safe way. The system is provided with 3 dedicated software to have automatically the default settings for adult and paediatric patients and new-borns. lt is provided with the automatic compensation of dead space, the leakages calculation and the automatic calibration of Fi02.
Operative Modes:
MAN
VC-VC
PCV-APCV
APCV
P -SIMV
V- SIMV
Measured parameters:
PAW
RATE
VM - VTE
T INSP
Fi02
MANUAL VENTILATION SYSTEM
The Morpheus is equipped with an advanced manual ventilation system that can be switched on and off automatically by the ventilator; the operator can select the APL system or the AUX system with traditional T-and-Fro valve and 02 by pass safety system.
BREATHING SYSTEM
The patient group of Morpheus LT is compact, lightweight for manual removal and fully autoclavable. The patient circuit group is supplied with an automatic heating system avoiding humidity with possibility to use reusable and rechargeable CO, absorbers (TOP SPECIAL) of 1 kg. Absorber is with quick-release enabling replacement also during anaesthesia. The group is supplied with an exposed bellow that can be manually inspected. The MorpheusLT is equipped with 3 wide and large drawers and a large work-shelf to facilitate operating rooms procedures.
Click Here To Download Catalogue |
| ||||||||||||||||||||||||
Weight | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||||
Dimensions | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||||
Additional information |
Reviews
There are no reviews yet.