| Description |
Shipped from Abroad
SUPiA made by Signers offers such a better clinic environment with no chemicals, ideal space, high-resolution image quality, and affordability.
Delivery & Availability:
Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped from abroad
The Neuropack S3 combines Nihon Kohden’s gold-standard amplifiers with time-saving and easy-to-use clinical software, bringing neurodiagnostic labs a feature-rich system that provides cleaner, easier and faster data. The foundation of effective neurodiagnostic testing is a system that can provide a full complement of neurodiagnostic tests while also offering the quality needed to analyze and monitor nervous system function.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
- Strong wooden top.
- With Casters for easy movement.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
Dimension (mm): L550 x W420 x H880 mm
Color: Grey
Material: Stainless steel
No of wheel: 4
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped from Abroad
The MORPHEUS M is an anaesthesia machine and it can be used on adult, children and newborn patients. The MORPHEUS M is suitable for administration of Oxygen – Air – Nitrous Oxide – Halothane – Enflurane – Isoflurane – Sevoflurane – Desflurane mixtures.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped from Abroad
The Genesis anaesthesia workstations meet your most ambitious requirements. They stand out for their lung protective ventilation.
Application Field: Neonates, Pediatrics & Adults
Ventilation Modes: Volume controlled (VC), Pressure controlled (PC), Adaptive Pressure with Volume Guaranteed (APVG) & Pressure Support Ventilation (PSV)
Delivery & Availability:
Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. |
| Content | SUPiA X-ray Digitizer made by Signers offers such a better clinic environment with no chemicals, ideal space, high-resolution image quality, and affordability
FEATURE
Rigid Type
• No damage or scratch on image plates during scanning & erasing
• Scanning & Erasing without a roller
• No cut-off image during winter and cold period
Durability
• Extremely simple structure design
• Strong aluminum base plate
• Flip covers preventing dust from inside scanner
Barcode System
• Automatically recognising cassette sizes(14x17", 10x12", 18x24cm) by barcode reader
Compact & lightweight design
- Very small and compatible CR on desktop (only 63.5cm)
- Only 21.5kg (47.4lbs)
Cassette
Strong structure
• Strong enough against external impact
• Totally metal frame
• Enduring under 150kg on cassette
Featherlight
• 14x17" : 2.05kg 10x12" : 0.99kg 18x24cm : 0.75kg
Dust free & Easy cleaning
• Easy to clean up dust on IPs
• Prevent dust from outside
User friendly design
• Various colors 14x17"(Green),
10x12"(Blue), 18x24cm(Pink))
• Barcode label
TECHNICAL SPECIFICATION
|
SUPiA Specifications |
|
| Cassette |
SUPiA CR Cassette 14x17 (inch)
SUPiA CR Cassette 10x12 (inch)
SUPiA CR Cassette 18x24 (cm) |
| Throughput |
Up to 94 IPs/hour (14x17"/160μm) |
| Slots |
Single Cassette feed |
| Dimensions (W x D x H) |
436 x 636 x 196mm |
| Weight |
21.5kg (47.4lbs) |
| Grayscale Resolution |
Acquisition : 16 bits per pixel
Display : 12 bits per pixel |
| Power Supply Conditions |
Single Phase 50 ~ 60Hz
AC 90 ~ 264V |
| Network |
100 MBit |
| PC Connection |
USB 2.0 |
| Computer Min.
requirements |
OS : Win 7 or 10
CPU : Intel i5
RAM : 4GB
Graphic Card : Intel HD 2500
HDD : 500GB
Monitor : FHD 1920 x 1080
|
| Operating conditions |
Temperature : 10 ~ 30˚C
Humidity : 15 ~ 85% RH |
| The Neuropack S3 combines Nihon Kohden’s gold-standard amplifiers with time-saving and easy-to-use clinical software, bringing neurodiagnostic labs a feature-rich system that provides cleaner, easier and faster data. The foundation of effective neurodiagnostic testing is a system that can provide a full complement of neurodiagnostic tests while also offering the quality needed to analyze and monitor nervous system function.
Features:
- State-of-the-art low-noise amplifier with 18-bit A/D converters and artifact-reduction software provides clean waveforms
- Built-in rejection ratios of 110 dB or greater (differential mode) and 112 dB or greater (isolation mode) limit variations in signals
- Electrode input impedance of 200 MΩ ±20% helps ensure clean signals
- On-screen examination guide directs electrode and stimulation placement for smooth and efficient examinations
- HL7® gateway integration helps ensure quick flow of information and streamlines workflow
- Intuitive control panel and stimulators aid in acquiring and progressing through studies
- Customizable protocols shorten examination time
- One-click report generation produces print-ready reports with customized logos, test results, exam waveforms and highlighted abnormal values
- Proprietary all-in-one NCS program performs MCS, SCS and F-wave for quick examinations
- Customized auto-copy settings allow waveforms to be stored and automatically transferred to long-term storage
Technical Specifications:
Main unit: DC-960B
Electrode junction box, 2 or 4 ch: JB-962B or JB-964B
Control unit, desktop: GG-961BK
Power supply: SC-230BK
Cart: KD-026A
Arm: KH-960A
Holder: DI-961B
Somato control box: RY-960B
LCD display: Local purchase
Printer: Local purchase
Number of channels: 2 or 4
Input impedance Common mode: >100 MΩ
Differential Mode: >200 MΩ
CMRR Differential Mode: >106 dB
Isolation Mode: >112 dB
Noise level: 0.6 μVrms
Sampling Resolution: 18 bit
Sensitivity: 1 to 500 μVrms/div., and 1 to 10 mVrms/div.
Low-cut filter: 0.01 Hz to 3 kHz
High-cut filter: 10 kHz to 20 kHz
Analysis time base: 0.1 ms/div to 1 s /div
Model Suffixes
EEG-1200 has the following suffixies:
J: 110-127 V AC operation
K: 220-240 V AC operation
|
- Strong wooden top.
- With Casters for easy movement.
|
| Dimension (mm) |
L550 x W420 x H880 mm |
| Color |
Grey |
| Material |
Stainless steel |
| No of wheel |
4 |
| The MORPHEUS M is an anaesthesia machine and it can be used on adult, children and newborn patients. The MORPHEUS M is suitable for administration of Oxygen – Air – Nitrous Oxide – Halothane – Enflurane – Isoflurane – Sevoflurane – Desflurane mixtures.
Features:
- Mechanic gas mixing system
- Electronic lung ventilator with 12” TFT colour display
- Valves group: open, semi-closed, closed, heated, with soda lime absorber (1,5 Kg)
- SIARETEX rapid connection device, Selectatec compatible for 2 vaporizers
- Gas supply group
- Ventilation modalities: APCV-PCV; APCV-TV; PSV; APNEA BACK-UP; VC-VAC; VC-VAC BABY; SIMV+PS (volumetric); SPONT; MANUAL.
- Measured parameters: PAW; PEEP; Vte; ExpMV; Rate; I:E; FiO2, Pmax; Pmean; Pause; Vti; FLOWi; FLOWe; Tinsp; Tesp; Tpause; Cs; Ri
- Displayed ventilation curves: Paw, Flow, Volume, Loop (Volume/Paw ; Volume/Flow)
- Adjustable parameters:
– O2 built-in Mixer device from 21% to 99%
– I:E Adjustable Ratio: 1:1-1:2-1:3-1:4-2:1-3:1
– Inspiratory Flow
– PEEP
– Breathing Rate
– Minute Volume;
– Tidal Volume
– Inspiratory Pressure Limit
– Inspiratory Pause
– Inspiratory Time
– Trigger
- Mechanic flowmeter module: 3-flow mechanical flow meter (O2 – N2O – AIR) with 5 flow meters for low flows. Equipped with safety systems (MIX-LIFE, CUT-OFF, flow meter protection valve).
- Breathing system: The breathing system of Morpheus guarantees to the user an absolute flexibility and easy handling thanks to the noble construction materials employed. The valves group can be drawn-up and it’s totally autoclavable at 121°C and all its parts are manually dismountable, with no need of special tools.The breathing system is made of; Calibrated APL valve, Fresh gas collecting bag, O2 cell for reading of FiO2, Removable 1 kg soda lime canister, Manually inspectionable bellows jar, Safety valve for ambience air suction in case of fresh gas failure, Flow transducer inside the group located on the expiratory line.
Optional accessories
11054 AIRPAK 54 stand-alone medical air compressor
100150/IDF Isoflurane Vaporizer
100148/IDF Fluo-Halotane Vaporizer
100145/IDF Sevoflurane Vaporizer
100151/IDF Desflurane Vaporizer
A57.049-800601 gas analysis module (5 AA – CO2 – N2O – O2 – MAC) ric.auto
) | The Genesis anaesthesia workstations meet your most ambitious requirements. They stand out for their lung protective ventilation, accuracy and performance, cost saving, design and ergonomics, safety and versatility.
TECHNICAL SPECIFICATION
OPERATING DATA
- Weight - 105 kg
- Dimensions - 92 cm Wide x 68 cm Deep x 139 cm High (93 cm to the table surface)
- Packaging Dimensions - 105 cm Wide x 75 cm Deep x 160 cm High
- Operating voltage supply - 110 to 240 V~, 47 to 63 Hz (12 to 6 A)
- Power input - 120 W typically (max. 1.2 kW with auxiliary outlets used)
- Battery autonomy - 90 min typically
- Auxiliary power outlets - 4, with automatic protection
- O2, N2O and Air supply - 2.7 to 6.9 bar (39.1 to 100 psi)
- Screen - TFT 18.5" (47 cm) projected capacitive touchscreen
- Protection class - Class I, gas analyser type BF defibrillation proof
- Classification - Class II b
- Storage - One front drawer with self-brake system and two back cabinets with door
- Lighting - LED bar below the screen controlled from the touchscreen
- Auxiliary integrated systems - Auxiliary 02 flow meter (0-15 L/min), Auxiliary 02 suppy valve (NF standard) and Suction device
- Communication ports - 1 x RS-232, 2 x USB, 1 x LAN Ethernet
Fresh Gases (02, N20 and Air, electronically controlled)
- Fresh gas flow - 0 and 0.1 to 18 L/min 02/N20/Air
- Accuracy - 0.1 to 0.5 L/min = ±0.05 L/min; 0.5 to 18 L/min = ±10 %
- 02 concentration - 21 to 100% vol. with Air, 25 to 100% with N20 (minimum 200 ml/min 02)
- 02 Safety fresh gas (backup) - 0-0.2-0.4-0.7-1-1.5- 2- 3- 4- 6- 8-10-12-15 L/min 02
- 02 flush (+02) - 40 L/min standard (adjustable 25 - 75 L/min upon requirement)
Breathing System (CABS)
- Autoclavable - 134 °C
- Weight of breathing system - 9.8 kg
- C02 absorber volume - 1.5 L
- Leakage - < 150 mL/min (at 30 hPa)
- Pressure limiting valve APL - 0 to 70 hPa
- Pressure relief valve - 125 hPa
- Vacuum safety valve - 0.3 hPa
- resistance at 60L/min - 5.80 hPa
- resistance at 60L/min - 2.90 hPa
- resistance at 30L/min - 3.55 hPa
- resistance at 30L/min - 0.89 hPa
- Internal Compliance at 30 hPa - 15 mL
VENTILATOR
Operation / Ventilation Modes
Volume controlled (VC) modes:
- Volume Controlled Ventilation (VCV)
- VC Synchronized Intermittent Mandatory Ventilation (VC-SIMV)
- VC-SIMV with Pressure Support (VC-SIMV-PS) *
Pressure controlled (PC) modes:
- Pressure Controlled Ventilation (PCV)
- PC Synchronized Intermittent Mandatory (PC-SIMV)
- PC-SIMV with Pressure Support (PC-SIMV-PS) *
Adaptive Pressure with Volume Guaranteed (APVG) modes (other trade names: Autoflow,PCVR, PRVC, AVAPS, VC+)
- Adaptive Pressure with Volume Guaranteed (APVG) *
- APVG Synchronized Intermittent Mandatory (APVG-SIMV) *
- APVG -SIMV with Pressure Support (APVG-SIMV-PS) *
Pressure Support Ventilation (PSV) *
- (other trade names: PS, ASB, SPS, IPS)
Non-mechanical Operation / Ventilation Modes
- Manual ventilation through the CABS system (Auto/Manual software controlled)
- Spontaneous ventilation either through the bellows (auto mode) or through the bag
- (manual mode) Manual ventilation through the external fresh gas outlet for non-rebreathing systems (Bain, Mapleson, ...)
Application field: Neonates, Pediatrics & Adults
- Tidal volume - 5 to 1500 mL
- Inspiratory pressure - 0 to 68 hPa
- Ventilation frequency - 3 to 120/min
- Inspiratory time - 0.05 to 16.6s
- l:E ratio - 5:1 to 1:8
- Inspiratory pause - 0 to 60%
- Inspiratory flow - max. 150 L/min
- PEEP - 0 to 30 hPa
- Flow trigger - 0.2 to 15 L/min
- Pressure support - 5 to 50 hPa
- Ramp time - 0.1 to 2 s
- Maximum pressure - 0 to 68 hPa
MONITORING
- 5" (47 cm) projected capacitive touchscreen, supported on a 360° rotating and 2 axis tilting arm.
- Measurements displayed: Peak pressure; Plateau pressure; Mean pressure; Expiratory minute ventilation; Expiratory tidal volume; Inspiratory tidal volume; Expiratory volumeter; Breathing rate; Compliance and Resistance (in VC modes); Patient info (age, weight, MAC, Class ASA); Connected sensors; Battery status; Power supply status; Gases supply pressures for 02, N20 and Air; Inspiratory and expiratory concentration of 02, N20, C02 and Anaesthetic gas*
- Parametres charted as curves (up to 3 simultaneously): Airway pressure; Expiratory flow; Inspiratory flow; Volume; Fresh gases (Rotstyle); Concentration of 02, N20, C02 and Anaesthetic gas*; Trends: Minute volume, MAC and gases (02, N20, C02 and Anaesthetic gas).
- Display for the performance of the hospital Anaesthetic Gas Scavenging System (AGSS).
- Configurable interface: bright/dark, multi-language.
- Loops (up to 2 simultaneously): Volume-Pressure, Flow-Volume, Pressure-Flow, C02-Volume.
- Fresh gas virtual rotameters for 02, N20, Air. * C02, N20 and Anaesthetic gas monitoring with the accessory multigas analyzer main-stream or side-stream; 02 real-time monitoring via paramagnetic
|
rixwhbakex
Muchas gracias. ?Como puedo iniciar sesion?