| Description | Shipped From Abroad
INCLIX™ HbA1c quantitatively measures HemoglobinA1c(HbA1c) concentration in whole blood using the INCLIX™ analyzer. For in vitro diagnostic use only.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
Alcohol Pad (70% Isopropyl Alcohol Pre Pad, Alcohol Cleansing Swab). Clean the required area. Discard after single use.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
- Made of high quality PP material with good transparency.
- Applied for Gilson/Finland/Eppendorf Pipettors.
- Carefully inspect of raw material and manufactured under strict process check, all tips are with excellent accuracy and precison.
- Special siliconizing on the inner surface ensure no liquid adhesion and accurate sample transfer.
- Standard tips and filter tips can be autoclaved, high temperature sterilization acceptable.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped from Abroad
GEMINI offers cost-savings, safety and a high degree of flexibility enabling a smooth laboratory workflow, thus making it a powerful system for all.
FEATURES
- Ease of use in application and maintenance
- Designed with sample and reagent ID-barcode reading, in-tip dilution reducing consumable costs
- Intuitive and highly flexible open software with complete data reduction and LIS interfaces
- Integrated PC and touchscreen eliminates the need for an external workstation
- Smart time-management allows processing up to 3 microplates simultaneously
Delivery & Availability:
Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
The Discover Cup is an all-in-one drug of abuse test cup. The strips are self contained and the entire cup is tamper resistant.
Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped From Aboard
The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.
Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. |
| Content |
- INCLIX™ HbA1c quantitatively measures HemoglobinA1c(HbA1c) concentration in whole blood using the INCLIX™ analyzer. For in vitro diagnostic use only.
- Hemoglobin A1c (glycated hemoglobin; HbA1c; A1c) test is the immunochromatography assay and intends for the quantitative determination of stable HbA1c in human blood. In this test system, HbA1c level is expressed in a percent as a good indicator to manage long-term glucose control in diabetes.
- The HbA1c Test is the immunochromatography method to determine the percentage of glycated HbA1c in human blood. The detector antibody conjugated with colloidal gold can bind to HbA1c in human blood at conjugate pad where it dried. The detector antibody and HbA1c complex flows through membrane to where capture antibody for total hemoglobin immobilized at membrane of the strip. The signal intensity is measured with the INCLIX™ analyzer and the signal reflectance is calculated and shown as a percentage of concentration with established standard with known the percentage of HbA1c in blood samples.
| Alcohol Pad (70% Isopropyl Alcohol Pre Pad, Alcohol Cleansing Swab). Clean the required area. Discard after single use.
Size and packing of Medical Alcohol pad:
- Pad Size: Unfolded: 30 x 60 mm (other size can be request ).
- Folded: 30x30 mm, 30 x 35mm,can be 2ply or 4ply ( other size, ply can be request ).
- Aluminum Package: 60 x 50 mm , 50 x 50mm approximate ( other size can be request ).
- Packing: 100/200 pcs per inner box, 50/ 100 boxes per carton(packing can be request).
Use of Medical Alcohol pad:
- For cleaning prior to injection or to disinfect the hurted skin for family and medical treatment organization use.
- For preparation and immediate disinfection of skin, wound area orr Instrument and utensil.
Notice of Medical Alcohol pad:
- Not for eyes;
- keep out of reach of children;
- For external use only;
- please stop using if you feel allergic or amyctic
Materials - Non-Woven Fabric
Specification - CE&ISO13485
|
- Made of high quality PP material with good transparency.
- Applied for Gilson/Finland/Eppendorf Pipettors.
- Carefully inspect of raw material and manufactured under strict process check, all tips are with excellent accuracy and precison.
- Special siliconizing on the inner surface ensure no liquid adhesion and accurate sample transfer.
- Standard tips and filter tips can be autoclaved, high temperature sterilization acceptable.
Classification: PIPETTE
Brand Name: Vchanslab,Yingmed,OEM
Model Number: YM-K7028
Place of Origin: China
Product name: Pipette Tips
Material: Polypropylene
Certificate: CE/ISO13485/FDA
Color: Natural, Blue, Yellow
Application: Laboratory, Teaching, Hospital | GEMINI offers cost-savings, safety and a high degree of flexibility enabling a smooth laboratory workflow, thus making it a powerful system for all.
FEATURES
- Ease of use in application and maintenance
- Designed with sample and reagent ID-barcode reading, in-tip dilution reducing consumable costs
- Intuitive and highly flexible open software with complete data reduction and LIS interfaces
- Integrated PC and touchscreen eliminates the need for an external workstation
- Smart time-management allows processing up to 3 microplates simultaneously
SPECIFIATIONS
Reader
- Photometric range: 0 to 3.0 OD
- Spectral range: 400 nm to 700 nm (up to 8 filters)
- Read time: < 15 sec single, < 30 sec dual
- Precision: 1% CV at 1.0 OD
- Accuracy: ±0.005 OD or 2.5 % (whichever is greater)
- Linearity: 0 to 2.000 OD ±1 %
Pipettor
- Min / max. volumes: 10 µl to 300 µl with 300 µl tip, 301 µl to 1000 µl with 1100 µl tip
- Precision (single dispense): < 3 % CV at 20 µl, < 3 % CV at 100 µl
- Precision (multi dispense): < 10 % CV at 16 x 20 µl, < 3 % CV at 8 x 100 µl
- Features: Pipetting pressure monitoring, capacitive liquid level detection, tip detection, mixing, multiple dilution steps, archiving
Capacity
- Sample and reagent capacity: Up to 192 samples (Flexible: e.g. 144 samples + 8 reagents + 16 controls)
Incubator
- Temperature range: Up to 45 °C
- Temperature uniformity: ±1.5 °C (with in-process temperature uniformity monitoring)
- Shaking: 20 Hz
Washer
- Precision: 10% CV at 300 µl
- Residual volume: <2.5 µl in U-bottom (mean), <4 µl in flat bottom (mean)
- Wash buffer capacity: 3 wash buffers
- Modes: Sweep mode, soak, top and bottom wash, variable pump speed
Dimensions
- Width x Depth x Height: 125 cm x 65 cm (without waste bag) x 75 cm with closed cover (49” x 26” x 30”)
|
FDA 510(K) & CLIA Waived
Up to 99% accuracy rate
Results in as little as 1 minute
24 Month Shelf Life from Date of Manufacture
Secure, seal and send to lab for confirmation
Built in temperature strip
Available to test up to 17 substances with adulterants or 18 without adulterants
Adulterants available
| The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric
analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.
Feature
- Auto zero function: Manual blanking not required
- Dual wavelength measurement system:
- 2 wave lengths 455nm and 575nm
- Plays major role to remove the interference caused due to Hemolysis & turbidity of sample
- LED Light source:
- LED does not require replacement as it lasts longer
- As compared to Lamp, LED are more suitable as there is no intensity fluctuations
- No warm up time required.
- Flexible unit selection:
- Two units either mg/dl or umol/L are selectable, ease of reporting
- Compact slot for Capillary:
- Accuracy of results are directly related to proper alignment of Capillary
- B-111 has the easiest mode to ensure precise values
- Data transfer:
- External device can be connected to instrument through RS232 por
- USB port
Technical Specification
- Light source - LED
- Wavelength - 455nm and 575nm
- Net weight - 1kg
- Measuring range - 0-30 mg/dl , 510 umol/L
- Display - 16×2 LCD module with backlight
- Auto calibration - Yes
- Sample type - Serum or plasma
- Sample volume - 40-80μL
- Test time - <5sec
- Units - mg/dl or umol/L
- Dimensions - 150 (W) × 115 (H) × 190 (D) mm
- Interface - RS232
- Reading cuvette - Heparinized micro capillary holder
- Storage temperature - 15-40°c
- Power supply - DC 9V(DC adapter)
- Power consumption - <2W
|