| Description | Shipped From Abroad
The BC32 Automated Blood Culture Systems are designed to accurately detect and recover microorganisms from blood and normally sterile body fluids (SBF)..
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped from Abroad
The MORPHEUS M is an anaesthesia machine and it can be used on adult, children and newborn patients. The MORPHEUS M is suitable for administration of Oxygen – Air – Nitrous Oxide – Halothane – Enflurane – Isoflurane – Sevoflurane – Desflurane mixtures.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
- Material: Aluminium
- Age Group: Adult Walkers
- Height: 37 Inch
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped from Abroad
The Genesis anaesthesia workstations meet your most ambitious requirements. They stand out for their lung protective ventilation.
Application Field: Neonates, Pediatrics & Adults
Ventilation Modes: Volume controlled (VC), Pressure controlled (PC), Adaptive Pressure with Volume Guaranteed (APVG) & Pressure Support Ventilation (PSV)
Delivery & Availability:
Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
First Aid Box Aluminium Large contains variety of medical item for emergency rescue, it contains items from simple digital or disposable thermometers to hard to find first aid items such as medical scissors, and many other items that could help save a situation before being taken to the hospital for proper treatment.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped From Abroad
The product is mainly suitable for solid medical waste (including pollution), waste plastic and rubber etc,at high temperatures they can be divided into organic compounds. We can offer all kinds of waste incinerator for industrial waste, medical waste, chemical waste and daily waste at any capacity.
Delivery & Availability:
Typically 60 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. |
| Content |
The BC32 Automated Blood Culture Systems are designed to accurately detect and recover microorganisms from blood and normally sterile body fluids (SBF). Runtime detection and sophisticated algorithms minimize false negatives and shorten time to positive detection.
- More Compact
- More Cost-Effective
- More Easily Controlled
Features:
Capacity: 32 Culture Bottle
Equipped with built-in computer and touch screen
Barcode scanning input
Colorimetric technology
Designed to detect microbial from blood specimen or sterile body fluid
Automated continuous monitoring for every 10 minutes for each bottle by independent detection sensor
Real-time display od incubation temperature and reaction chart
Flexible and quick historical data query and statistic functions
Operating Temp: 5~300C
Operating Humidity: <80%%
Voltage: AC100-240V
| The MORPHEUS M is an anaesthesia machine and it can be used on adult, children and newborn patients. The MORPHEUS M is suitable for administration of Oxygen – Air – Nitrous Oxide – Halothane – Enflurane – Isoflurane – Sevoflurane – Desflurane mixtures.
Features:
- Mechanic gas mixing system
- Electronic lung ventilator with 12” TFT colour display
- Valves group: open, semi-closed, closed, heated, with soda lime absorber (1,5 Kg)
- SIARETEX rapid connection device, Selectatec compatible for 2 vaporizers
- Gas supply group
- Ventilation modalities: APCV-PCV; APCV-TV; PSV; APNEA BACK-UP; VC-VAC; VC-VAC BABY; SIMV+PS (volumetric); SPONT; MANUAL.
- Measured parameters: PAW; PEEP; Vte; ExpMV; Rate; I:E; FiO2, Pmax; Pmean; Pause; Vti; FLOWi; FLOWe; Tinsp; Tesp; Tpause; Cs; Ri
- Displayed ventilation curves: Paw, Flow, Volume, Loop (Volume/Paw ; Volume/Flow)
- Adjustable parameters:
– O2 built-in Mixer device from 21% to 99%
– I:E Adjustable Ratio: 1:1-1:2-1:3-1:4-2:1-3:1
– Inspiratory Flow
– PEEP
– Breathing Rate
– Minute Volume;
– Tidal Volume
– Inspiratory Pressure Limit
– Inspiratory Pause
– Inspiratory Time
– Trigger
- Mechanic flowmeter module: 3-flow mechanical flow meter (O2 – N2O – AIR) with 5 flow meters for low flows. Equipped with safety systems (MIX-LIFE, CUT-OFF, flow meter protection valve).
- Breathing system: The breathing system of Morpheus guarantees to the user an absolute flexibility and easy handling thanks to the noble construction materials employed. The valves group can be drawn-up and it’s totally autoclavable at 121°C and all its parts are manually dismountable, with no need of special tools.The breathing system is made of; Calibrated APL valve, Fresh gas collecting bag, O2 cell for reading of FiO2, Removable 1 kg soda lime canister, Manually inspectionable bellows jar, Safety valve for ambience air suction in case of fresh gas failure, Flow transducer inside the group located on the expiratory line.
Optional accessories
11054 AIRPAK 54 stand-alone medical air compressor
100150/IDF Isoflurane Vaporizer
100148/IDF Fluo-Halotane Vaporizer
100145/IDF Sevoflurane Vaporizer
100151/IDF Desflurane Vaporizer
A57.049-800601 gas analysis module (5 AA – CO2 – N2O – O2 – MAC) ric.auto
) |
| Material |
Aluminium |
| Age Group |
Adult Walkers |
| Height |
37 Inch |
| The Genesis anaesthesia workstations meet your most ambitious requirements. They stand out for their lung protective ventilation, accuracy and performance, cost saving, design and ergonomics, safety and versatility.
TECHNICAL SPECIFICATION
OPERATING DATA
- Weight - 105 kg
- Dimensions - 92 cm Wide x 68 cm Deep x 139 cm High (93 cm to the table surface)
- Packaging Dimensions - 105 cm Wide x 75 cm Deep x 160 cm High
- Operating voltage supply - 110 to 240 V~, 47 to 63 Hz (12 to 6 A)
- Power input - 120 W typically (max. 1.2 kW with auxiliary outlets used)
- Battery autonomy - 90 min typically
- Auxiliary power outlets - 4, with automatic protection
- O2, N2O and Air supply - 2.7 to 6.9 bar (39.1 to 100 psi)
- Screen - TFT 18.5" (47 cm) projected capacitive touchscreen
- Protection class - Class I, gas analyser type BF defibrillation proof
- Classification - Class II b
- Storage - One front drawer with self-brake system and two back cabinets with door
- Lighting - LED bar below the screen controlled from the touchscreen
- Auxiliary integrated systems - Auxiliary 02 flow meter (0-15 L/min), Auxiliary 02 suppy valve (NF standard) and Suction device
- Communication ports - 1 x RS-232, 2 x USB, 1 x LAN Ethernet
Fresh Gases (02, N20 and Air, electronically controlled)
- Fresh gas flow - 0 and 0.1 to 18 L/min 02/N20/Air
- Accuracy - 0.1 to 0.5 L/min = ±0.05 L/min; 0.5 to 18 L/min = ±10 %
- 02 concentration - 21 to 100% vol. with Air, 25 to 100% with N20 (minimum 200 ml/min 02)
- 02 Safety fresh gas (backup) - 0-0.2-0.4-0.7-1-1.5- 2- 3- 4- 6- 8-10-12-15 L/min 02
- 02 flush (+02) - 40 L/min standard (adjustable 25 - 75 L/min upon requirement)
Breathing System (CABS)
- Autoclavable - 134 °C
- Weight of breathing system - 9.8 kg
- C02 absorber volume - 1.5 L
- Leakage - < 150 mL/min (at 30 hPa)
- Pressure limiting valve APL - 0 to 70 hPa
- Pressure relief valve - 125 hPa
- Vacuum safety valve - 0.3 hPa
- resistance at 60L/min - 5.80 hPa
- resistance at 60L/min - 2.90 hPa
- resistance at 30L/min - 3.55 hPa
- resistance at 30L/min - 0.89 hPa
- Internal Compliance at 30 hPa - 15 mL
VENTILATOR
Operation / Ventilation Modes
Volume controlled (VC) modes:
- Volume Controlled Ventilation (VCV)
- VC Synchronized Intermittent Mandatory Ventilation (VC-SIMV)
- VC-SIMV with Pressure Support (VC-SIMV-PS) *
Pressure controlled (PC) modes:
- Pressure Controlled Ventilation (PCV)
- PC Synchronized Intermittent Mandatory (PC-SIMV)
- PC-SIMV with Pressure Support (PC-SIMV-PS) *
Adaptive Pressure with Volume Guaranteed (APVG) modes (other trade names: Autoflow,PCVR, PRVC, AVAPS, VC+)
- Adaptive Pressure with Volume Guaranteed (APVG) *
- APVG Synchronized Intermittent Mandatory (APVG-SIMV) *
- APVG -SIMV with Pressure Support (APVG-SIMV-PS) *
Pressure Support Ventilation (PSV) *
- (other trade names: PS, ASB, SPS, IPS)
Non-mechanical Operation / Ventilation Modes
- Manual ventilation through the CABS system (Auto/Manual software controlled)
- Spontaneous ventilation either through the bellows (auto mode) or through the bag
- (manual mode) Manual ventilation through the external fresh gas outlet for non-rebreathing systems (Bain, Mapleson, ...)
Application field: Neonates, Pediatrics & Adults
- Tidal volume - 5 to 1500 mL
- Inspiratory pressure - 0 to 68 hPa
- Ventilation frequency - 3 to 120/min
- Inspiratory time - 0.05 to 16.6s
- l:E ratio - 5:1 to 1:8
- Inspiratory pause - 0 to 60%
- Inspiratory flow - max. 150 L/min
- PEEP - 0 to 30 hPa
- Flow trigger - 0.2 to 15 L/min
- Pressure support - 5 to 50 hPa
- Ramp time - 0.1 to 2 s
- Maximum pressure - 0 to 68 hPa
MONITORING
- 5" (47 cm) projected capacitive touchscreen, supported on a 360° rotating and 2 axis tilting arm.
- Measurements displayed: Peak pressure; Plateau pressure; Mean pressure; Expiratory minute ventilation; Expiratory tidal volume; Inspiratory tidal volume; Expiratory volumeter; Breathing rate; Compliance and Resistance (in VC modes); Patient info (age, weight, MAC, Class ASA); Connected sensors; Battery status; Power supply status; Gases supply pressures for 02, N20 and Air; Inspiratory and expiratory concentration of 02, N20, C02 and Anaesthetic gas*
- Parametres charted as curves (up to 3 simultaneously): Airway pressure; Expiratory flow; Inspiratory flow; Volume; Fresh gases (Rotstyle); Concentration of 02, N20, C02 and Anaesthetic gas*; Trends: Minute volume, MAC and gases (02, N20, C02 and Anaesthetic gas).
- Display for the performance of the hospital Anaesthetic Gas Scavenging System (AGSS).
- Configurable interface: bright/dark, multi-language.
- Loops (up to 2 simultaneously): Volume-Pressure, Flow-Volume, Pressure-Flow, C02-Volume.
- Fresh gas virtual rotameters for 02, N20, Air. * C02, N20 and Anaesthetic gas monitoring with the accessory multigas analyzer main-stream or side-stream; 02 real-time monitoring via paramagnetic
| First Aid Box Aluminium Large contains variety of medical item for emergency rescue, it can contain items from simple digital or disposable thermometers to hard to find first aid items such as medical scissors, and many other items that could help save a situation before being taken to the hospital for proper treatment. | LDF series waste incinerator adopt gasification combustion that can make garbage more sufficient burning. Waste incinerator is a kind of machine that possess the own intellectual property, features unique and advanced merits with compact size, high burning efficiency, reasonable burning technology, high degree of non-harm etc, it is an ideal choice for waste treatment of hospital, hotels, various stations and industries.
Features:
- Both gas-motivated and oil-motivated are all can be preferred according to customers' needs.
- Gasified incineration is used for burning syringe, paper waste, bandage, absorbent cotton and other medical wastes.
- Daily waste can be burned once by gasified incineration.
- Gasified incineration, mixed incineration and burnout treatment ensures low emission standard of dust (lower than International standard).
- Totally enclosed operation is suitable for treating infectious waste to avoid secondary pollution.
Advantages:
- Long lifetime
- Totally enclosed operation
- Suitable for treating infectious waste
- Avoid secondary pollution
- Simple operation
- Smokeless and no harmful to environment
- Continuously and fully burning
- Simple operation
Incinerator LDF-100 Parameter:
| Applicable hospital size |
250 beds |
| Max. Burning Ability |
100 kg/time |
| Size of the Burner |
1.5m×1.15m×3m |
| Volume of the Burner |
Gasification room 0.5m3 |
| second buming room 0.3m3 |
| Chamber Temperature |
First chamber:600℃-700℃; |
| second chamber:300℃-1300℃ |
|
| Ash residue |
≤5% |
| Size of the filling entrance |
620mm×800mm |
| Chimney |
Hight 10m,Out-radiusØ300 |
| Blower |
0.37kw |
| Auxiliary machine |
Power0.11kw,fuel consumption4-10kg/h |
| Re-burning machine |
Power0.11kw,fuel consumption6-10kg/h |
| Running voltage |
220V or 380V |
| Weight |
About 4600(kg) |
Flue&Gas Emission Standards:
| OrdinalNumber |
Refuse name |
Measuring unit |
GB18484-2001 |
| 1 |
Blackness of Flue |
Ringelmann class |
1 |
|
|
|
Gas |
|
|
|
| 2 |
Smoke&Dust |
mg/m3 |
100 |
|
| 3 |
CO |
mg/m3 |
100 |
|
| 4 |
SO2 |
mg/m3 |
400 |
|
| 5 |
HF |
mg/m3 |
9.0 |
|
| 6 |
HCL |
mg/m3 |
100 |
|
| 7 |
NO2 |
mg/m3 |
500 |
Click Here To Download Catalogue |
Reviews
There are no reviews yet.