Automatic Elisa Plate Reader, 96 Wells Plate
$0.00
Shipped From Abroad
Automatic ELISA plate reader is a lab device designed to analyze enzyme-linked immunosorbent assays (ELISAs) efficiently. With the capability to read 96 wells at once, it automates the detection and quantification of proteins, peptides, antibodies, and hormones. It’s like having a tiny robot in your lab that speeds up your workflow and ensures accuracy.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
Elisa Plate Reader Features:
The ELMR-96/ELMR-96I is a popular elisa plate reader capable of sensitively measuring absorbance signals on microtiter plates, accurately detecting and analyzing the concentration and activity of biomolecules.
- 7-inch high-resolution LCD capacitive touch screen for simple operation and easy viewing of test results
- Detection accuracy with single wavelength and dual wavelength detection for fast plate reading
- A wavelength range of 340-750nm can meet a variety of applications
- 8-bit filter wheel, 4 filters as standard, with various other optional filters
- With vibration plate function, vibration plate time and speed adjustable
- With self-test and diagnostic functions for optical path, moving position, etc
- Light source energy-saving design maximises the service life of the light source
- There is no need to open the shell design; you can complete the replacement of light sources and filters
Elisa Plate Reader Specifications:
| Model | ELMR-96/ELMR-96I |
|---|---|
| Light Source | 6V 10W halogen lamp |
| Wavelength Range | 340~750nm |
| Filter | Standard configuration: 405, 450, 492, 630nm four filters; It can be loaded with up to eight filters |
| Absorbance Range | 0.000-4.000Abs |
| Resolution | 0.001Abs |
| Linearity | (0, 2.0)≤±1%; [2.0, 4.0)≤±2% |
| Wavelength Indication Error | ≤±3nm |
| Wavelength Repeatability | ≤±1.5nm |
| Repeatability | [0, 3.0)≤0.3%, [3, 4.0)≤1% |
| Stability | [0, 3.0)≤0.3%, [3.0, 4.0)≤1% |
| Accuracy | [0, 2.0)≤ ± 0.005, [2.0 ,3.0)≤ ± 1%, [3.0, 4.0)≤ ± 1.5% |
| Sensitivity | Sensitivity≥0.010 |
| Channel Difference | <0.01A(1.0Abs standard filter ) |
| Measuring Speed | Single wavelength <10s/96 wells, dual wavelengths <16s/96 wells (normal mode) |
| Incubation Temperature | Room temperature+4℃-50℃ (ELMR-96I) |
| Ambient Temperature | 4℃~ 45℃ |
| Relative Humidity | ≤70% |
| Power Supply | AC100-240V, 50/60Hz |
| Sizes(W×D×H)(mm) | 280x432x220 |
| Shipping Size(W×D×H)(mm) | 580x430x360 |
| N.W./G.W. (kg) | 8.5/13 |
Quick Comparison
| Automatic Elisa Plate Reader, 96 Wells Plate remove | Avalun LabPad Device remove | Eppendorf Minispin Centrifuge remove | Hawksley 1400 Haematocrit Centrifuge remove | Lancet Pack remove | Erma B-111 Bilirubin Meter remove | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Name | Automatic Elisa Plate Reader, 96 Wells Plate remove | Avalun LabPad Device remove | Eppendorf Minispin Centrifuge remove | Hawksley 1400 Haematocrit Centrifuge remove | Lancet Pack remove | Erma B-111 Bilirubin Meter remove | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
| SKU | SF1033560130127-49 | SF1033560084-65 | SF1033560084-116 | SF1033560084-118 | SF1033560084-144 | SF1033560084-6 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Rating | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Price |
|
|
|
|
|
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Stock | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Availability | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Add to cart | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Description | Shipped From Abroad
Automatic ELISA plate reader is a lab device designed to analyze enzyme-linked immunosorbent assays (ELISAs) efficiently. With the capability to read 96 wells at once, it automates the detection and quantification of proteins, peptides, antibodies, and hormones. It's like having a tiny robot in your lab that speeds up your workflow and ensures accuracy.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| In stock The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
| In stock
| In stock
| Shipped From Aboard
The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.
Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Content | Elisa Plate Reader Features:The ELMR-96/ELMR-96I is a popular elisa plate reader capable of sensitively measuring absorbance signals on microtiter plates, accurately detecting and analyzing the concentration and activity of biomolecules.
Elisa Plate Reader Specifications:
| The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes.
Click Here To Download Catalogue | Powerful and user-friendly MiniSpin Centrifuge are small enough so that each workstation can be equipped with a “personal” centrifuge. The rotor, inner centrifuge lid, and lid latch are made of metal for maximum operation safety.
Features:
Click Here To Download Catalogue | The Hawksley Haematospin 1400 Centrifuges are built in the UK and are made from durable and high-quality components. These centrifuges are ideal for veterinary laboratories and practices specifically designed to produce reliable and accurate results on blood and urine. One of the main features of this centrifuge is that it takes both 2ml microtubes and 75mm microhaematocrits. The classic design of these centrifuges is used worldwide with guaranteed support for all servicing and parts.
Technical specifications:
Click Here To Download Catalogue |
| The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric
analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.
Feature
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Weight | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Dimensions | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Additional information |







Reviews
There are no reviews yet.