Blood Pressure Monitor CT40

$0.00

Shipped From Abroad

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130132-5
Brands:: SUNTECH

Description

BP technology, the new SunTech CT40 is the ideal, affordable solution for clinical-grade spot-check measurements of blood pressure plus vital signs in hospitals and clinics. Ambulatory care, long-term care and low-acuity hospital departments can easily implement this versatile, user-friendly vital signs device that delivers SunTech clinical-grade performance, advanced features and digital connectivity.

Unique to the SunTech CT40, its modular design allows clinicians to easily make adaptations to the device while in the field – adding thermometry, SpO2 and Wi-Fi based solely on the needs of the patient.

Features

With the Suntech CT40, you can count on us to deliver:

Quality: Clinical-grade Advantage™ BP technology

Reliability: Manual SphygMode™ for real-time verification of BP readings without removing the cuff plus built-in memory for up to 99 charting sessions

Accuracy: Customizable BP averaging protocol to ensure accurate, consistent readings (SPRINT recommended)

Connectivity: HL7 messaging protocols for data transfer with network connection through built-in LAN/Ethernet, 2 USB ports or optional Wi-Fi

Flexibility: Modular design for addition of optional temperature and SpO2 modules

Simplicity: Intuitive user interface with LCD display

Options & Accessories
  • Covidien Filac® 3000 Thermometry
  • Masimo SET® SpO2 (preferred)
  • ChipOx Nellcor®-compatible SpO2
  • Mobile Stand
  • Barcode Scanner
  • Wi-Fi

 

Picture of the SunTech CT40 with available options and accessories, including the various modules.
Technical Specifications

SpO2 Specifications

Function Masimo M-LNCS DCI ChipOx
Saturation Normal (no motion) 70-100%Arms ± 2% 70-100%Arms ± 2%
Saturation Motion 70-100%Arms ± 3% N/A
Low Perfusion SpO2 +/-2% N/A
Pulse Heart rate ± 3% BPM 20-300 BPM: ±3 BPM
Pulse Heart rate w/motion ± 3% BPM 20-300 BPM: ±3 BPM

Temperature Specifications

Function Covidien Electronic Thermometer
Temperature Accuracy Quick Mode (Oral): ± 0.3°C
Temperature Accuracy Std. Mode (Aux/Rectal): ± 0.1°C
Temperature Accuracy Direct Mode ± 0.1°C
Response Time 4 sec (quick mode); 10-15 sec. (Axillary/Rectal); 60 sec.(direct mode)
Resolution 0.1°C

Blood Pressure Specifications

Specifications Values
Range:
  • Pressure: Diastolic: 20-200 mmHg (adult), 20-160 mmHg (pediatric).
  • Systolic: 40-260 mmHg (adult), 40-230 mmHg (pediatric)
  • Heart Rate: 30-220 BPM (beats per minute)
Accuracy (BP): Meets or exceeds ANSI/AAMI/ISO 81060-2:2013 standard for non-invasive accuracy (±5mmHg mean error with 8mmHg standard deviation).
General Specifications
Specifications Values
Conditions for Use: Operating: 10°C (50°F) to 40°C (104°F) 15 – 90% RH non-condensing – 700 kPa – 1060 kPa. Operating the monitor in an environment at maximum temperature can produce temperatures exceeding 41°C (41.6°C highest recorded) on a patient-applied part. It is up to the operator to determine if this temperature is too high based upon the condition of the patient and, if so, to ensure the ambient temperature of the environment is 38°C or below.
Storage: -20°C (-4°F) to 55°C (149°F) 15 – 90% RH non-condensing – 500 kPa – 1060 kPa. Performance can be affected if used or stored outside the specified temperature, humidity, or altitude listed in the ranges above.
Power: Internal power supply. Input: 100-240 VAC @ 1.5A max, 50-60 Hz. Output +9VDC @ 5A IEC 320 type input connector.
Battery: Type: 7.2v, 6600mAh Internal Lithium-Ion battery Run Time (full charge): ~20 hrs* / 200 BP cycles Charge Time: ~6 hrs @ 23deg Celsius +/- 2deg *Unit with BP, Temp, SpO2, Wi-Fi, barcode scanner
Calibration: The accuracy of cuff -pressure transducers/indicators should be verified bi-annually.
Safety Systems: Independent hardware over-pressure circuit and redundant software overpressure algorithm to limit cuff pressure to less than 300 mmHg (+20/-10mmHg). Independent hardware timing circuit and redundant software timer algorithm to limit the duration of a blood pressure cycle to less than 180 seconds.
Dimensions: Size (without thermometer option): 8” H x 6.75’’ W x 5.2’’ D or 215mm H x 190mm W x 140mm D
Standards: ANSI/AAMI ES60601-1:2005/(R)2012 and A1:2012, C1:2009/(R)2012 and A2:2010/(R)2012, EN 60601-1:2006/A1:2013, IEC 60601-1-2: 2007 EMC, IEC 80601-2-30: 2013, ISO 80601-2-61: 2011, ISO 15223-1:2012, ISO 10993-1, 2009, ISO 10993-5, 2009, EN ISO 10993-10, 2010, ISO 81060-2:2013, EN 50419: 2006, EN ISO 14971:2009, CSA C22.2 No. 60601-1, EN ISO 81060-1: 2012, IEC 60601-1-6: 2013
Classifications: Equipment Classification: Class IIa per MDD, Class I (Electrical Shock), Continuous mode of operation, CE
Ingress of liquid: Ingress Protection: IPX1: This device is protected against harmful effects of dripping water per IEC 60529.

 

Reviews

There are no reviews yet.

Be the first to review “Blood Pressure Monitor CT40”

Your email address will not be published. Required fields are marked *

Quick Comparison

Blood Pressure Monitor CT40 removeMale Urinal removeWeight and Height Scale removeOmron (PFM20) Peak Flow Meter remove2-Function Manual Hospital Bed removeDrip Stand remove
NameBlood Pressure Monitor CT40 removeMale Urinal removeWeight and Height Scale removeOmron (PFM20) Peak Flow Meter remove2-Function Manual Hospital Bed removeDrip Stand remove
ImageOmron (PFM20) Peak Flow Meter
SKUSF1033560130132-5SF1033560084-86SF1033560084-107SF1033560084-96SF1033560084-52SF1033560084-67
Rating
Price

$0.00

$0.00

$0.00

$0.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock This weight and height scale has two functions, the body weight and height measuring. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In Stock Max loading:180KG(400lb) in movement Backrest tilting From 0°to 75°±5° Footrest tilting From 0°to 40°±5°

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock Drip Stand is a very simple, easy to adjust and maneuver product. Suitable for most healthcare environments, this drip stand is light in weight made of high-quality stainless steel. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content

BP technology, the new SunTech CT40 is the ideal, affordable solution for clinical-grade spot-check measurements of blood pressure plus vital signs in hospitals and clinics. Ambulatory care, long-term care and low-acuity hospital departments can easily implement this versatile, user-friendly vital signs device that delivers SunTech clinical-grade performance, advanced features and digital connectivity.

Unique to the SunTech CT40, its modular design allows clinicians to easily make adaptations to the device while in the field – adding thermometry, SpO2 and Wi-Fi based solely on the needs of the patient.
Features
With the Suntech CT40, you can count on us to deliver: Quality: Clinical-grade Advantage™ BP technology Reliability: Manual SphygMode™ for real-time verification of BP readings without removing the cuff plus built-in memory for up to 99 charting sessions Accuracy: Customizable BP averaging protocol to ensure accurate, consistent readings (SPRINT recommended) Connectivity: HL7 messaging protocols for data transfer with network connection through built-in LAN/Ethernet, 2 USB ports or optional Wi-Fi Flexibility: Modular design for addition of optional temperature and SpO2 modules Simplicity: Intuitive user interface with LCD display
Options & Accessories
  • Covidien Filac® 3000 Thermometry
  • Masimo SET® SpO2 (preferred)
  • ChipOx Nellcor®-compatible SpO2
  • Mobile Stand
  • Barcode Scanner
  • Wi-Fi
 
Picture of the SunTech CT40 with available options and accessories, including the various modules.
Technical Specifications
SpO2 Specifications
Function Masimo M-LNCS DCI ChipOx
Saturation Normal (no motion) 70-100%Arms ± 2% 70-100%Arms ± 2%
Saturation Motion 70-100%Arms ± 3% N/A
Low Perfusion SpO2 +/-2% N/A
Pulse Heart rate ± 3% BPM 20-300 BPM: ±3 BPM
Pulse Heart rate w/motion ± 3% BPM 20-300 BPM: ±3 BPM
Temperature Specifications
Function Covidien Electronic Thermometer
Temperature Accuracy Quick Mode (Oral): ± 0.3°C
Temperature Accuracy Std. Mode (Aux/Rectal): ± 0.1°C
Temperature Accuracy Direct Mode ± 0.1°C
Response Time 4 sec (quick mode); 10-15 sec. (Axillary/Rectal); 60 sec.(direct mode)
Resolution 0.1°C
Blood Pressure Specifications
Specifications Values
Range:
  • Pressure: Diastolic: 20-200 mmHg (adult), 20-160 mmHg (pediatric).
  • Systolic: 40-260 mmHg (adult), 40-230 mmHg (pediatric)
  • Heart Rate: 30-220 BPM (beats per minute)
Accuracy (BP): Meets or exceeds ANSI/AAMI/ISO 81060-2:2013 standard for non-invasive accuracy (±5mmHg mean error with 8mmHg standard deviation).
General Specifications
Specifications Values
Conditions for Use: Operating: 10°C (50°F) to 40°C (104°F) 15 – 90% RH non-condensing - 700 kPa - 1060 kPa. Operating the monitor in an environment at maximum temperature can produce temperatures exceeding 41°C (41.6°C highest recorded) on a patient-applied part. It is up to the operator to determine if this temperature is too high based upon the condition of the patient and, if so, to ensure the ambient temperature of the environment is 38°C or below.
Storage: -20°C (-4°F) to 55°C (149°F) 15 – 90% RH non-condensing - 500 kPa - 1060 kPa. Performance can be affected if used or stored outside the specified temperature, humidity, or altitude listed in the ranges above.
Power: Internal power supply. Input: 100-240 VAC @ 1.5A max, 50-60 Hz. Output +9VDC @ 5A IEC 320 type input connector.
Battery: Type: 7.2v, 6600mAh Internal Lithium-Ion battery Run Time (full charge): ~20 hrs* / 200 BP cycles Charge Time: ~6 hrs @ 23deg Celsius +/- 2deg *Unit with BP, Temp, SpO2, Wi-Fi, barcode scanner
Calibration: The accuracy of cuff -pressure transducers/indicators should be verified bi-annually.
Safety Systems: Independent hardware over-pressure circuit and redundant software overpressure algorithm to limit cuff pressure to less than 300 mmHg (+20/-10mmHg). Independent hardware timing circuit and redundant software timer algorithm to limit the duration of a blood pressure cycle to less than 180 seconds.
Dimensions: Size (without thermometer option): 8” H x 6.75’’ W x 5.2’’ D or 215mm H x 190mm W x 140mm D
Standards: ANSI/AAMI ES60601-1:2005/(R)2012 and A1:2012, C1:2009/(R)2012 and A2:2010/(R)2012, EN 60601-1:2006/A1:2013, IEC 60601-1-2: 2007 EMC, IEC 80601-2-30: 2013, ISO 80601-2-61: 2011, ISO 15223-1:2012, ISO 10993-1, 2009, ISO 10993-5, 2009, EN ISO 10993-10, 2010, ISO 81060-2:2013, EN 50419: 2006, EN ISO 14971:2009, CSA C22.2 No. 60601-1, EN ISO 81060-1: 2012, IEC 60601-1-6: 2013
Classifications: Equipment Classification: Class IIa per MDD, Class I (Electrical Shock), Continuous mode of operation, CE
Ingress of liquid: Ingress Protection: IPX1: This device is protected against harmful effects of dripping water per IEC 60529.
 
This weight and height scale has two functions, the body weight and height measuring.
Model NO.: FM-S120
Application: Commercial Scale, Special Scales
Display Type: Analog
Function: Weighing Scale
Structure: Electronic Scale
Shape: Square
Maximum Weight: 120kg
Measuring Range: 70-190cm
Min. Division: 0.5cm
Tolerance: +/- 0.5cm
Size of Platform (L* W): 280*380 mm
Minimum Scale: 0.5kg
Trademark: FULLMEDI
Transport Package: Wooden Case / Carton
Specification: Weight 14kg
Origin: China
OMRON Peak Flow Meter (PFM20) offers reliable and accurate peak expiratory flow measurements to help you monitor your asthma symptoms.it is portable, easy to use, and suitable for adults and children. With this device, you can personalize the monitoring and create an Asthma Action Plan with a respond that is most appropriate to your symptoms. The device is designed to help you monitor and manage your asthma symptoms with ease. The device comes with the following parts:
  • Colour-zone markers (in green, yellow and red)
  • Pointer
  • Sterilizable and removeable mouthpiece
The colour-zone markers allow you to personalize your Peak Flow Meter and guide you in your Asthma Action Plan. They are used to indicate your personal best PEF reading.
Product Size:2125*970*540mm Packing size: 205*96*26cm/2pcs Max loading:180KG(400lb) in movement Backrest tilting From 0°to 75°±5° Footrest tilting From 0°to 40°±5° Standard Accessories: 4pcs 5” standard castor two with brake, 1 pair aluminum side rail, 2pcs ABS head and foot board, 4pcs urine hooks, 2pcs cranks system
Drip Stand is a very simple, easy to adjust and maneuver product. Suitable for most healthcare environments, this drip stand is light in weight made of high-quality stainless steel. Use : Bedridden patients, Senior citizen care, Patients in coma Advantages :
  • High quality stainless steel construction
  • Properly electroplated for anti rust finish
  • Ball shaped castors for smooth movement
  • Provided with an infusion stand
  • Attached 4 pcs hook
  • Maximum load strength
  • Screw safety height adjustment
  • Light weight
   
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare