Dry Block Heater PE-4010 (22 sockets, d=18х85 mm)
$0.00
Shipped From Abroad
Purpose:
The dry block heater is intended for heating the samples in reaction vessels (10 ml) in fixed temperature regime under laboratory conditions.
Delivery & Availability:
Typically, 14-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
Purpose:
The dry block heater is intended for heating the samples in reaction vessels (10 ml) in fixed temperature regime under laboratory conditions.
The following functions are implemented in the device:
– setting and indication of the specified heating temperature
– setting the timer for switching on the heating after expiration of the specified time (delayed start)
– setting the timer for switching off the heating after expiration of the specified time
– socket for mounting the control thermometer
Technical specifications:
– Working temperature range, °С – from ambient +10 to 180
– Temperature maintenance accuracy, °С – ± 0.2
– Temperature gradient within the block volume – ± 0.2°С
– Temperature setting discreteness, °С – 0.1
– Timer interval setting range (switch-controlled):
– from 1 s to 99 min 59 s, the discreteness is 1 s
– from 1 min to 99 hours 59 min, the discreteness is 1 min (factory setting)
– from 1 hour to 99 days 23 hours, the discreteness is 1 hour
– Power consumption, W – 350
– Overall dimensions (WxDxH), mm – 220×275х160
– Weight, kg – 4.5
– Socket dimensions, mm – ?18×85
– Number of sockets – 22
Scope of delivery:
1. Dry block heater – 1 pc.
2. Removable handle for moving the block – 1 pc.
3. Mains cable – 1 pc.
4. Data Sheet and Operating Manual – 1 pc.
Quick Comparison
| Dry Block Heater PE-4010 (22 sockets, d=18х85 mm) remove | AGD Erma EL-120 ELectrolyte Analyzer remove | Pipette Holder remove | Lancet Pack remove | Sugentech Inclix (POCT) Immunoassay Analyzer remove | Eppendorf Pipette Tip 300ul Per Pack remove | |||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Name | Dry Block Heater PE-4010 (22 sockets, d=18х85 mm) remove | AGD Erma EL-120 ELectrolyte Analyzer remove | Pipette Holder remove | Lancet Pack remove | Sugentech Inclix (POCT) Immunoassay Analyzer remove | Eppendorf Pipette Tip 300ul Per Pack remove | ||||||||||||||||||||||||||||||||||||||||
| Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ||||||||||||||||||||||||||||||||||||||||
| SKU | SF10335601099 | SF1033560084-125 | SF1033560084-148 | SF1033560084-144 | SF1033560084-89 | SF1033560084-138 | ||||||||||||||||||||||||||||||||||||||||
| Rating | ||||||||||||||||||||||||||||||||||||||||||||||
| Price |
|
|
|
|
|
| ||||||||||||||||||||||||||||||||||||||||
| Stock | ||||||||||||||||||||||||||||||||||||||||||||||
| Availability | ||||||||||||||||||||||||||||||||||||||||||||||
| Add to cart | ||||||||||||||||||||||||||||||||||||||||||||||
| Description | Shipped From Abroad
Purpose: The dry block heater is intended for heating the samples in reaction vessels (10 ml) in fixed temperature regime under laboratory conditions. Delivery & Availability: Typically, 14-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped From Abroad
| In stock
The linear and round stands have been designed to fit perfectly of TOPTION Pipette range, TopPette,MicroPette and MicroPette Plus Autoclavable Pipettes. The stands are convenient to hold up 6 pipettes both of single and multi-channel.
| In stock
| In stock INCLIX™ is an immunochromatographic analyzer providing immediate point-of-care testing (POCT) at patient care settings or clinical laboratories. It facilitates automatic detection of various biomarkers for cardiovascular disease, infectious disease, cancer, diabetes, allergy, and etc. with high accuracy and sensitivity. INCLIX™ analyzer is a compact, easy-to-use and cost-effective multi-parameter POCT instrument and its unique user friendly software provides an efficient data management system. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
| ||||||||||||||||||||||||||||||||||||||||
| Content | Purpose: The dry block heater is intended for heating the samples in reaction vessels (10 ml) in fixed temperature regime under laboratory conditions. The following functions are implemented in the device: - setting and indication of the specified heating temperature - setting the timer for switching on the heating after expiration of the specified time (delayed start) - setting the timer for switching off the heating after expiration of the specified time - socket for mounting the control thermometer Technical specifications: - Working temperature range, °С – from ambient +10 to 180 - Temperature maintenance accuracy, °С - ± 0.2 - Temperature gradient within the block volume - ± 0.2°С - Temperature setting discreteness, °С – 0.1 - Timer interval setting range (switch-controlled): - from 1 s to 99 min 59 s, the discreteness is 1 s - from 1 min to 99 hours 59 min, the discreteness is 1 min (factory setting) - from 1 hour to 99 days 23 hours, the discreteness is 1 hour - Power consumption, W - 350 - Overall dimensions (WxDxH), mm - 220x275х160 - Weight, kg – 4.5 - Socket dimensions, mm – ?18x85 - Number of sockets - 22 Scope of delivery: 1. Dry block heater - 1 pc. 2. Removable handle for moving the block – 1 pc. 3. Mains cable - 1 pc. 4. Data Sheet and Operating Manual – 1 pc. | Electrolyte Analyzer ERMA EL-120 is ideal for medium to high volume Laboratories and Hospitals . It offers reliable, automated samples handling and work flow offences . It also allows measurement of specific ions, accurately and precisely . This supports fast diagnosis of critically ill patients and reduces the risks of patient discomfort associated with repeated sampling Precise & Accurate Results Economical to use Large Touchscreen Display with Graphical User Interface.
Features:
Click Here To Download Catalogue | The linear and round stands have been designed to fit perfectly of TOPTION Pipette range, TopPette,MicroPette and MicroPette Plus Autoclavable Pipettes. The stands are convenient to hold up 6 pipettes both of single and multi-channel.
Features:
|
| INCLIX™ is an immunochromatographic analyzer providing immediate point-of-care testing (POCT) at patient care settings or clinical laboratories. It facilitates automatic detection of various biomarkers for cardiovascular disease, infectious disease, cancer, diabetes, allergy, and etc. with high accuracy and sensitivity. INCLIX™ analyzer is a compact, easy-to-use and cost-effective multi-parameter POCT instrument and its unique user friendly software provides an efficient data management system.
Features:
• Good accuracy owning to superior CMOS sensor & our own Algorism
• 10,000 test results data storage
• Instrument Check by Reference Kit
• Remote Support available (when connected via Internet)
• Built-in Thermal Printer and Barcode Scanner
• Data export to USB(PDF, Excel), Email and LIS
• Storage Temperature of Test Cassette & Buffer : Room temperature, 2 ~ 30 ℃
• Shelf Life of Test Cassette & Buffer : 24 months
Click Here To Download Catalogue |
| ||||||||||||||||||||||||||||||||||||||||
| Weight | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||||||||||||||||||||
| Dimensions | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||||||||||||||||||||
| Additional information |







Reviews