DynaMesh-SIS direct

$0.00

Shipped From Abroad

DynaMesh®-SIS direct, DynaMesh®-SIS direct soft, and DynaMesh®-SIS direct visible implants are intended to be used as a mid-urethral sling for the surgical treatment of stress urinary incontinence caused by a hypermobile urethra and/or intrinsic sphincter deficiency. The devices permanently reinforce the soft tissue of the pelvic floor.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130161-8
Brands:: Dyna Mesh

Description



Retropubic Tape Position
(Inside-Out)

DM-SIS-retrosymphysary

 

Transobturator Tape Position
(Outside-In or Inside-Out)

DM-SIS-transobturatoric

 

DynaMesh®-SISDynaMesh®-SIS soft and DynaMesh®-SIS visible are positioned using the inside-out technique in case of a retropubic tape position, and using the outside-in or inside-out technique in case of a transobturator tape position.


The devices have a thread at the ends of the tape that is attached to the surgical instrument.

 

Several reusable instruments are available separately to position the device:

DynaMesh®-ISR01:
Instrument for transvaginal access for retropubic positioning of DynaMesh®-SIS, DynaMesh®-SIS soft and DynaMesh®-SIS visible using the inside-out technique.


Diameter: 5-7 cm

DynaMesh®-IST01 / DynaMesh®-IST02 / DynaMesh®-IST03:
Instrument set consisting of two instruments for transvaginal access for transobturator positioning of DynaMesh®-SIS, DynaMesh®-SIS soft and DynaMesh®-SIS visible using the inside-out or outside-in technique.

DynaMesh®-IVT01:
Instrument for transvaginal access for transobturator positioning of DynaMesh®-SIS, DynaMesh®-SIS soft and DynaMesh®-SIS visible using the outside-in technique.

Specifications
Product DynaMesh®-SIS (1)
DynaMesh®-SIS soft (2)
DynaMesh®-SIS visible (3)
Surgical Treatment Stress Urinary Incontinence (SUI)
Surgical Approach Transvaginal
Surgical Technique TVT – Retropubic – Inside-Out /
TOT – Transobturator – Outside-In
Fixation None
Smooth Warp-Knitted Selvedges
gruene_punkte
Shape Stability
gruene_punkte[TR12, TR13]
Defined Elasticity
gruene_punkte[TR10]
Visible Technology
graue_punkte (1) (2) / gruene_punkte (3)
Materials
– Polyvinylidene fluoride (PVDF) (CAS 24937-79-9) > 99% (w/w) (1) – (3)
– Phthalocyanine green (CAS 1328-53-6) < 1% (w/w) (1) (2)
– Triiron tetraoxide (CAS 1317-61-9) < 1% (w/w) (3)
Polymer (Monofilament)
PVDF
Biocompatibility
gruene_punkte[TR1]
Ageing Resistance
gruene_punkte[2A, 5VIT, 27A, 52VIT, 93A, 101]
Effective Porosity gruene_punkte  High effective porosity reduces inflammation and the risk of excessive scar formation. [103P, TR11]
Klinge’s Mesh Classification Class 1a  [102P, TR11]

 

Click here to download Catalogue

Reviews

There are no reviews yet.

Be the first to review “DynaMesh-SIS direct”

Your email address will not be published. Required fields are marked *

Quick Comparison

DynaMesh-SIS direct removeRender SD-H3000B+ Mobile ICU Ventilator removeDrip Stand removeRender SD-H3000B Mobile ICU Ventilator removeAmbu Bag with Reservior removei-gel Supraglottic Airway remove
NameDynaMesh-SIS direct removeRender SD-H3000B+ Mobile ICU Ventilator removeDrip Stand removeRender SD-H3000B Mobile ICU Ventilator removeAmbu Bag with Reservior removei-gel Supraglottic Airway remove
Image
SKUSF1033560130161-8SF1033560011-23SF1033560084-67SF1033560011-22SF1033560084-41SF1033560084-76
Rating
Price

$0.00

$0.00

$0.00

$0.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad DynaMesh®-SIS direct, DynaMesh®-SIS direct soft, and DynaMesh®-SIS direct visible implants are intended to be used as a mid-urethral sling for the surgical treatment of stress urinary incontinence caused by a hypermobile urethra and/or intrinsic sphincter deficiency. The devices permanently reinforce the soft tissue of the pelvic floor.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad
  • Microcomputer controlled,pneumatically driven and electronically controlled.
  • Pressure, volume controlled treatment ventilator.
  • Could be applied for pediatric and adult.
  • 100% oxygen fast operation system, make sure to provide pure oxygen at any time.
  • Easy setting by navigator wheel knob & touch key
  • 5.5" lcd display,very clearly at parameter setting area,monitoring area or alarm area.
  • Automatic temperature control humidifier system for operation and maintenance easier
  • Back-up battery
  • Built-in smart type air compressor
Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock Drip Stand is a very simple, easy to adjust and maneuver product. Suitable for most healthcare environments, this drip stand is light in weight made of high-quality stainless steel. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped from Abroad
  • Pneumatically driven electric controlled、micro-computer controlled unit.
  • Operation control panel adopts distinct LED display, easy operation.
  • High quality humidifier.
  • Contains high quality tubes、accessories、spare parts
Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
Ambu Bag with Reservior: The ventilation bag is highly reactive with fast recoil and excellent stroke volume which help relieving fatigue to the rescuer. The thin-walled compression bag provides an excellent feel of lung compliance and helps avoid excessive ventilation that could damage the lungs.
  Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
i-gel Supraglottic Airway: The i-gel® is the innovative second generation supraglottic airway device from Inter surgical. The first major development since the laryngeal mask airway, i-gel has changed the face of airway management.
  Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content


Retropubic Tape Position (Inside-Out)

DM-SIS-retrosymphysary

 
Transobturator Tape Position (Outside-In or Inside-Out)

DM-SIS-transobturatoric

 
DynaMesh®-SISDynaMesh®-SIS soft and DynaMesh®-SIS visible are positioned using the inside-out technique in case of a retropubic tape position, and using the outside-in or inside-out technique in case of a transobturator tape position.

The devices have a thread at the ends of the tape that is attached to the surgical instrument.
 
Several reusable instruments are available separately to position the device:

DynaMesh®-ISR01: Instrument for transvaginal access for retropubic positioning of DynaMesh®-SIS, DynaMesh®-SIS soft and DynaMesh®-SIS visible using the inside-out technique.

Diameter: 5-7 cm

DynaMesh®-IST01 / DynaMesh®-IST02 / DynaMesh®-IST03: Instrument set consisting of two instruments for transvaginal access for transobturator positioning of DynaMesh®-SIS, DynaMesh®-SIS soft and DynaMesh®-SIS visible using the inside-out or outside-in technique.

DynaMesh®-IVT01: Instrument for transvaginal access for transobturator positioning of DynaMesh®-SIS, DynaMesh®-SIS soft and DynaMesh®-SIS visible using the outside-in technique.

Specifications
Product DynaMesh®-SIS (1) DynaMesh®-SIS soft (2) DynaMesh®-SIS visible (3)
Surgical Treatment Stress Urinary Incontinence (SUI)
Surgical Approach Transvaginal
Surgical Technique TVT – Retropubic – Inside-Out / TOT – Transobturator – Outside-In
Fixation None
Smooth Warp-Knitted Selvedges
gruene_punkte
Shape Stability
gruene_punkte[TR12, TR13]
Defined Elasticity
gruene_punkte[TR10]
Visible Technology
graue_punkte (1) (2) / gruene_punkte (3)
Materials
– Polyvinylidene fluoride (PVDF) (CAS 24937-79-9) > 99% (w/w) (1) – (3) – Phthalocyanine green (CAS 1328-53-6) < 1% (w/w) (1) (2) – Triiron tetraoxide (CAS 1317-61-9) < 1% (w/w) (3)
Polymer (Monofilament)
PVDF
Biocompatibility
gruene_punkte[TR1]
Ageing Resistance
gruene_punkte[2A, 5VIT, 27A, 52VIT, 93A, 101]
Effective Porosity gruene_punkte  High effective porosity reduces inflammation and the risk of excessive scar formation. [103P, TR11]
Klinge’s Mesh Classification Class 1a  [102P, TR11]
 

Click here to download Catalogue

Features:
  • Microcomputer controlled,pneumatically driven and electronically controlled.
  • Pressure, volume controlled treatment ventilator.
  • Could be applied for pediatric and adult.
  • 100% oxygen fast operation system, make sure to provide pure oxygen at any time.
  • Easy setting by navigator wheel knob & touch key
  • 5.5" lcd display,very clearly at parameter setting area,monitoring area or alarm area.
  • Automatic temperature control humidifier system for operation and maintenance easier
  • Back-up battery
  • Built-in smart type air compressor
  Technical Specifications:
Model NO. - SD-H3000B+
Type - ICU Ventilator Machine
Used for - Adult
O2 Concentration - 21%-100%
Use for - ICU Operating Room
Tidal Volume - 0-2000ml
Min Tidal Volume - 50-1500ml
I:E - 5.0:1~1:5.0
Peep - 0-40cm H2O
Certification - CE, FDA, ISO13485
Trademark - RENDER
Origin - China
HS Code - 9018907000
Click Here To Download Catalogue
   
Drip Stand is a very simple, easy to adjust and maneuver product. Suitable for most healthcare environments, this drip stand is light in weight made of high-quality stainless steel. Use : Bedridden patients, Senior citizen care, Patients in coma Advantages :
  • High quality stainless steel construction
  • Properly electroplated for anti rust finish
  • Ball shaped castors for smooth movement
  • Provided with an infusion stand
  • Attached 4 pcs hook
  • Maximum load strength
  • Screw safety height adjustment
  • Light weight
   
Mobile ICU Ventilator Features:
  • Pneumatically driven electric controlled、micro-computer controlled unit.
  • Operation control panel adopts distinct LED display, easy operation.
  • High quality humidifier.
  • Contains high quality tubes、accessories、spare parts
  Technical Specification:
Model NO. - SD-H3000B
Type -Ventilator
O2 Concentration - 21%-100%
Use for - ICU Operating Room
Tidal Volume - 0-2000ml
Min Tidal Volume - 50-1500ml
I:E - 5.0:1~1:5.0
Peep - 0-40cm H2O
Certification - CE, FDA, ISO13485
Group - Adult
LCD Display - With LCD Display
Trademark - RENDER
Origin - China
HS Code - 9018907000
Click Here To Download Catalogue
 
Ambu Bag with Reservior: The ventilation bag is highly reactive with fast recoil and excellent stroke volume which help relieving fatigue to the rescuer. The thin-walled compression bag provides an excellent feel of lung compliance and helps avoid excessive ventilation that could damage the lungs.
Features:
  • Brand: OEM
  • Item No.: AM-DMR-M06-0/1/4
  • Color: Green
  • Size: Adult/Pediatric/Infant
  • Material: Disposable
  • Application: Emergency Resuscitation
  • MOQ: 300
  • Lead Time: 60 days
  • Shipping Terms: FOB
  • Packaging Details: Each set is packed into a white PP box
  • Carton Size: 57 x 34 x 46 CM / 12 SETS
  • Shipping Weight: 9.8 Kilos
  Technical Specifications:
Type Infant Pediatric Adult
Patient weight ≤10kg 10kg-40kg >40kg
Stroke volume 150ml 400ml 800ml
Resuscitator volume 280ml 600ml 1650ml
Dimensions L x D 135 x 75mm 146 x 100mm 212 x 131mm
Resuscitator weight 350g 410g 600g
Pressure limiting valve 40cmH2O 40cmH2O 60cmH2O
Inspiratory resistance <5cmH2O (at 50L/min)
Expiratory resistance <5cmH2O (at 50L/min)
Bag volume 1600ml 1600ml 2000ml
Patient connector ISO5356-1:φ22/15mm Male/Female
Recommended operating temperature -18℃~+50℃
Storage Tested at -40℃ and 60℃
 
 
i-gel Supraglottic Airway: The i-gel® is the innovative second generation supraglottic airway device from Intersurgical. The first major development since the laryngeal mask airway, i-gel has changed the face of airway management. Features: i-gel has a soft, gel-like, non-inflatable cuff, designed to provide an anatomical impression fit over the laryngeal inlet. The shape, softness and contours accurately mirror the perilaryngeal anatomy - an innovative concept meaning no cuff inflation is required. Working in harmony with the patient's anatomy, compression and displacement trauma are significantly reduced or eliminated.
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare