Handheld Capnograph and Oximeter Capno-H

$0.00

Shipped From Abroad

A handheld carbon dioxide monitor with automatic atmospheric pressure compensation, high accuracy, suitable for various complex environments.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130170-2
Brands:: Kingst

Description

Features of Kingst Handheld Capnograph and Oximeter Capno-H
  • Certification – With FDA certification, CE certification, 1SO9000 certification, the product conforms to RoHS, ETCO2 module conforms to FDA certification
  • Compact and Lightweight – 3.5 inch LCD display, 380g weight
  • Technique – Using non-scattering infrared gas analysis technology
  • Unit – kpa, %, mmHg
  • Air pump flow – The air pump flow is adjustable, its range: 50cc/min—250cc/min
  • Safety – Patented filter to ensure continuous machine work without obstacles

 

Specifications
AC Input 100V – 240V, 50Hz/60 Hz to 5VDC Adapter with 5V type-CUSB adapter Cable. Optional Vehicle 12V to 5V Type-CUSB Charger Lead.
Battery Built-in rechargeable lithium battery pack (3.7V, 3500mAH)
Temperature 5 to +40 ℃
Humidity 30-75%
Atmospheric pressure 86~106kpa
EtCO2/FiCO2 Range 0~150mmHg
Accuracy ±2mmHg for CO2 range 0 – 40mmHg;
±5% for CO2 range from 41 – 70mmHg;

±8% for CO2 range from 71 – 100mmHg;

Over 100mmHg ±10%

Respiration Rate Range 3~150 breaths/minute
Accuracy ±1% of reading or ±1 rpm whichever is greater
Size 72 x 155 x 38mm (W x H x D)
Weight Weight on Airway ETT/LMA<25g. Monitor 380g
Display size 3.5 inches

 

Application Scenarios of Kingst Handheld Capnograph and Oximeter Capno-H
  • Two modes are available: sidestream and mainstream.

  • Capno-H can simultaneously measure blood oxygen saturation, pulse rate, ETCO2 and respiratory rate. Its lithium battery can support continuous work at full load for more than 10 hours; Capno-H is available for short and long-term monitoring of adults, pediatrics, and infants. It is ready to use after power on and no need to calibrate.
  • Capno-H has automatic atmospheric pressure compensation that can provide accurate monitoring whether in plateau or helicopter rescue.
  • With selected interference gas, pulmonary pressure and body temperature compensation to achieve the higher precision.
  • With simple maintenance and sturdy structure, Capno-H is suitable for various harsh environments.

Reviews

There are no reviews yet.

Be the first to review “Handheld Capnograph and Oximeter Capno-H”

Your email address will not be published. Required fields are marked *

Quick Comparison

Handheld Capnograph and Oximeter Capno-H removeDolphin-XF Transcranial Robotic Probe removeSiare Morpheus M Anaesthetic Machine removeDolphin-IQ Transcranial Doppler Probe removeSpinal Epidural Pack removeHersill Genesis Anaesthetic Machine remove
NameHandheld Capnograph and Oximeter Capno-H removeDolphin-XF Transcranial Robotic Probe removeSiare Morpheus M Anaesthetic Machine removeDolphin-IQ Transcranial Doppler Probe removeSpinal Epidural Pack removeHersill Genesis Anaesthetic Machine remove
ImageHersill Genesis Anaesthetic Machine
SKUSF1033560130170-2SF1033560130142-4SF1033560101-2SF1033560130142-3SF1033560084-25SF1033560450-1
Rating
Price

$0.00

$0.00

$0.00

$0.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad A handheld carbon dioxide monitor with automatic atmospheric pressure compensation, high accuracy, suitable for various complex environments.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad Proudly introducing the X-Factor in TCD robotic solutions, assisting in obtaining bilateral TCD insonations in as quickly as just a few seconds!. Designed for short and long-term monitoring, for use in anesthesia, in the ICU, or in the TCD lab.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad The MORPHEUS M is an anaesthesia machine and it can be used on adult, children and newborn patients. The MORPHEUS M is suitable for administration of Oxygen – Air – Nitrous Oxide – Halothane – Enflurane – Isoflurane – Sevoflurane – Desflurane mixtures. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped From Abroad All of the advantages and performance of the cutting-edge Dolphin TCD technology for measurements of cerebral blood flow velocities are implemented in the smart and compact Dolphin/IQ Transcranial Doppler module.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock It is for performing spinal/epidural or combined spinal/epidural or never-block loco-regional anaesthesia on patinet in clinical surgery.

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad The Genesis anaesthesia workstations meet your most ambitious requirements. They stand out for their lung protective ventilation. Application Field: Neonates, Pediatrics & Adults Ventilation Modes: Volume controlled (VC), Pressure controlled (PC), Adaptive Pressure with Volume Guaranteed (APVG) & Pressure Support Ventilation (PSV) Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Features of Kingst Handheld Capnograph and Oximeter Capno-H
  • Certification - With FDA certification, CE certification, 1SO9000 certification, the product conforms to RoHS, ETCO2 module conforms to FDA certification
  • Compact and Lightweight - 3.5 inch LCD display, 380g weight
  • Technique - Using non-scattering infrared gas analysis technology
  • Unit - kpa, %, mmHg
  • Air pump flow - The air pump flow is adjustable, its range: 50cc/min---250cc/min
  • Safety - Patented filter to ensure continuous machine work without obstacles
 
Specifications
AC Input 100V - 240V, 50Hz/60 Hz to 5VDC Adapter with 5V type-CUSB adapter Cable. Optional Vehicle 12V to 5V Type-CUSB Charger Lead.
Battery Built-in rechargeable lithium battery pack (3.7V, 3500mAH)
Temperature 5 to +40 ℃
Humidity 30-75%
Atmospheric pressure 86~106kpa
EtCO2/FiCO2 Range 0~150mmHg
Accuracy ±2mmHg for CO2 range 0 - 40mmHg; ±5% for CO2 range from 41 - 70mmHg; ±8% for CO2 range from 71 - 100mmHg; Over 100mmHg ±10%
Respiration Rate Range 3~150 breaths/minute
Accuracy ±1% of reading or ±1 rpm whichever is greater
Size 72 x 155 x 38mm (W x H x D)
Weight Weight on Airway ETT/LMA<25g. Monitor 380g
Display size 3.5 inches
 
Application Scenarios of Kingst Handheld Capnograph and Oximeter Capno-H
  • Two modes are available: sidestream and mainstream.

  • Capno-H can simultaneously measure blood oxygen saturation, pulse rate, ETCO2 and respiratory rate. Its lithium battery can support continuous work at full load for more than 10 hours; Capno-H is available for short and long-term monitoring of adults, pediatrics, and infants. It is ready to use after power on and no need to calibrate.
  • Capno-H has automatic atmospheric pressure compensation that can provide accurate monitoring whether in plateau or helicopter rescue.
  • With selected interference gas, pulmonary pressure and body temperature compensation to achieve the higher precision.
  • With simple maintenance and sturdy structure, Capno-H is suitable for various harsh environments.
https://youtu.be/JwSJvUVJrxo?si=6QkpitWAwvZZSwOM  
Description
The Dolphin/XF is a new breakthrough development in TCD robotics. It is designed to assist the user in quickly and automatically insonating and monitoring cerebral blood flow.
Features

Comfortable Headset

The unique Dolphin/XF robot fits the patient’s head with a soft and comfortable dedicated monitoring headset. The patient’s posture is of no limitation, and thus the patient can lay down, be seated, or stand up during the measurements with the robot without any discomfort or preventing factors in the headset.

Ultra Fast Scanning

Use the Fast Scan mode for rapid scanning within seconds. Or use the High-Resolution Scan option for a more detailed robotic search through the temporal or suboccipital windows. This latter option generates a “heat map” as a function of insonated depth, showing all of the identified blood flow velocities flowing either towards the probe or away from the probe. https://youtu.be/QsaSaUbh7as?si=Vky2fSg6Mc3Ft_ob

Ideal Monitoring Solution

The Dolphin/XF TCD robot is ideal for settings where short or long-term monitoring is required. This includes applications in:
  • Anesthesia and the Operating Room (OR),
  • HITS detection for longer-term applications, 
  • Specialty Test protocols such as Vasomotor Reactivity (VMR), Breath Holding or PFO testing for short term monitoring, 
  • Use in the ICU, or 
  • With SAH or Stroke patients where cerebral blood flow monitoring is of particular importance. 
https://youtu.be/b6dDU1mGQ8Q?si=md0GOLuI1mUt6ouv
The MORPHEUS M is an anaesthesia machine and it can be used on adult, children and newborn patients. The MORPHEUS M is suitable for administration of Oxygen – Air – Nitrous Oxide – Halothane – Enflurane – Isoflurane – Sevoflurane – Desflurane mixtures. Features:
  • Mechanic gas mixing system
  • Electronic lung ventilator with 12” TFT colour display
  • Valves group: open, semi-closed, closed, heated, with soda lime absorber (1,5 Kg)
  • SIARETEX rapid connection device, Selectatec compatible for 2 vaporizers
  • Gas supply group
  • Ventilation modalities: APCV-PCV; APCV-TV; PSV; APNEA BACK-UP; VC-VAC; VC-VAC BABY; SIMV+PS (volumetric); SPONT; MANUAL.
  • Measured parameters: PAW; PEEP; Vte; ExpMV; Rate; I:E; FiO2, Pmax; Pmean; Pause; Vti; FLOWi; FLOWe; Tinsp; Tesp; Tpause; Cs; Ri
  • Displayed ventilation curves: Paw, Flow, Volume, Loop (Volume/Paw ; Volume/Flow)
  • Adjustable parameters: – O2 built-in Mixer device from 21% to 99% – I:E Adjustable Ratio: 1:1-1:2-1:3-1:4-2:1-3:1 – Inspiratory Flow – PEEP – Breathing Rate – Minute Volume; – Tidal Volume – Inspiratory Pressure Limit – Inspiratory Pause – Inspiratory Time – Trigger
  • Mechanic flowmeter module: 3-flow mechanical flow meter (O2 – N2O – AIR) with 5 flow meters for low flows. Equipped with safety systems (MIX-LIFE, CUT-OFF, flow meter protection valve).
  • Breathing system: The breathing system of Morpheus guarantees to the user an absolute flexibility and easy handling thanks to the noble construction materials employed. The valves group can be drawn-up and it’s totally autoclavable at 121°C and all its parts are manually dismountable, with no need of special tools.The breathing system is made of; Calibrated APL valve, Fresh gas collecting bag, O2 cell for reading of FiO2, Removable 1 kg soda lime canister, Manually inspectionable bellows jar, Safety valve for ambience air suction in case of fresh gas failure, Flow transducer inside the group located on the expiratory line.
Optional accessories 11054 AIRPAK 54 stand-alone medical air compressor 100150/IDF Isoflurane Vaporizer 100148/IDF Fluo-Halotane Vaporizer 100145/IDF Sevoflurane Vaporizer 100151/IDF Desflurane Vaporizer A57.049-800601 gas analysis module (5 AA – CO2 – N2O – O2 – MAC) ric.auto  
Click Here To Download Catalogue
                              )
https://youtu.be/Id0Ma1_lEo0?si=kRJ1bUMjUCBuCAqR  
Features of Dolphin TCD Machine

Best Quality Doppler

Fully digital Doppler technology with the amazing Dolphin TCD post-processing capabilities lets you review and replay the measured spectrum with audio at any depth. Unmatched clinical diagnosis capabilities.

Best TCD Robotic Probe

The unique Dolphin/XF robotic probe changes the Transcranial Doppler monitoring market as is known to date. Fast and simple scanning is achieved thanks to special algorithms and processes for blood flow detection. The Dolphin/XF robot is comfortable and stable, simplifying probe fixation and saving time.

Continuous Monitoring Made Easy

The Dolphin devices are well designed to assist the technician or physician in performing short or long-term Monitoring. The Dolphin Headset design comes with the unique probe Quick-Lock – the best locking solution. The Dolphin software is rich with quality features for optimal patient diagnosis, including a complete replay of the entire recording, placement of automatic and predefined markers, and availability of trends display.

Unbeatable Durability and Reliability

The Dolphin is considered by many as the most reliable Transcranial Doppler machine in the market. A range of high-quality Doppler probes is available for different clinical applications and optimal Doppler penetration of the temporal window.

Designed for Portability

The Dolphin TCD machines are the most portable TCD machine on the market. Dolphin/MAX and Dolphin/4D are slim, lightweight, and have a large 18″ Touch Screen, which can be seen from a distance in the ICU or other clinical settings. Their design allows you to simply hand carry them or use the VESA mount options to easily connect the TCD system to a cart or trolley. The Dolphin/MAX has a built-in integrated battery that lasts for hours.

Complete Network Connectivity

The unmatched Dolphin connectivity capabilities are ideal for hospital IT personnel and EMR / PACS administrators. The advanced Dolphin TCD networking abilities allow a simple plug-and-play operation to quickly configure connectivity with automated DICOM Worklist & Storage, Structured Report, and HL7. With unlimited Review Stations, measurements can be reanalyzed and interpreted from the comfort of your office. Final reporting can also be configured and finalized from any location.

Unmatched HITS Detection

Optimal and accurate counts of suspected embolic events using a high-resolution proprietary algorithm that simultaneously detects HITS (emboli events) in all gates! The numerous advanced analysis options of each suspected emboli include an extraordinary high-resolution power M Mode display during HITS detection (up to 50 times faster than the Doppler spectrum!).
It is for performing spinal/epidural or combined spinal/epidural or never-block loco-regional anaesthesia on patinet in clinical surgery. Component:
  • Epidural needle 16G,
  • Epidural catheter,
  • Epidural filter 0.2 um,
  • Catheter connector,
  • LOR syringe
The Genesis anaesthesia workstations meet your most ambitious requirements. They stand out for their lung protective ventilation, accuracy and performance, cost saving, design and ergonomics, safety and versatility.   TECHNICAL SPECIFICATION OPERATING DATA
  • Weight - 105 kg
  • Dimensions - 92 cm Wide x 68 cm Deep x 139 cm High (93 cm to the table surface)
  • Packaging Dimensions - 105 cm Wide x 75 cm Deep x 160 cm High
  • Operating voltage supply - 110 to 240 V~, 47 to 63 Hz (12 to 6 A)
  • Power input - 120 W typically (max. 1.2 kW with auxiliary outlets used)
  • Battery autonomy - 90 min typically
  • Auxiliary power outlets - 4, with automatic protection
  • O2, N2O and Air supply - 2.7 to 6.9 bar (39.1 to 100 psi)
  • Screen - TFT 18.5" (47 cm) projected capacitive touchscreen
  • Protection class - Class I, gas analyser type BF defibrillation proof
  • Classification - Class II b
  • Storage - One front drawer with self-brake system and two back cabinets with door
  • Lighting - LED bar below the screen controlled from the touchscreen
  • Auxiliary integrated systems - Auxiliary 02 flow meter (0-15 L/min), Auxiliary 02 suppy valve (NF standard) and Suction device
  • Communication ports - 1 x RS-232, 2 x USB, 1 x LAN Ethernet
Fresh Gases (02, N20 and Air, electronically controlled)
  • Fresh gas flow - 0 and 0.1 to 18 L/min 02/N20/Air
  • Accuracy - 0.1 to 0.5 L/min = ±0.05 L/min; 0.5 to 18 L/min = ±10 %
  • 02 concentration - 21 to 100% vol. with Air, 25 to 100% with N20 (minimum 200 ml/min 02)
  • 02 Safety fresh gas (backup) - 0-0.2-0.4-0.7-1-1.5- 2- 3- 4- 6- 8-10-12-15 L/min 02
  • 02 flush (+02) - 40 L/min standard (adjustable 25 - 75 L/min upon requirement)
Breathing System (CABS)
  • Autoclavable - 134 °C
  • Weight of breathing system - 9.8 kg
  • C02 absorber volume - 1.5 L
  • Leakage - < 150 mL/min (at 30 hPa)
  • Pressure limiting valve APL - 0 to 70 hPa
  • Pressure relief valve - 125 hPa
  • Vacuum safety valve - 0.3 hPa
  • resistance at 60L/min - 5.80 hPa
  • resistance at 60L/min - 2.90 hPa
  • resistance at 30L/min - 3.55 hPa
  • resistance at 30L/min - 0.89 hPa
  • Internal Compliance at 30 hPa - 15 mL
  VENTILATOR Operation / Ventilation Modes Volume controlled (VC) modes:
  • Volume Controlled Ventilation (VCV)
  • VC Synchronized Intermittent Mandatory Ventilation (VC-SIMV)
  • VC-SIMV with Pressure Support (VC-SIMV-PS) *
Pressure controlled (PC) modes:
  • Pressure Controlled Ventilation (PCV)
  • PC Synchronized Intermittent Mandatory (PC-SIMV)
  • PC-SIMV with Pressure Support (PC-SIMV-PS) *
Adaptive Pressure with Volume Guaranteed (APVG) modes (other trade names: Autoflow,PCVR, PRVC, AVAPS, VC+)
  • Adaptive Pressure with Volume Guaranteed (APVG) *
  • APVG Synchronized Intermittent Mandatory (APVG-SIMV) *
  • APVG -SIMV with Pressure Support (APVG-SIMV-PS) *
Pressure Support Ventilation (PSV) *
  • (other trade names: PS, ASB, SPS, IPS)
  Non-mechanical Operation / Ventilation Modes
  • Manual ventilation through the CABS system (Auto/Manual software controlled)
  • Spontaneous ventilation either through the bellows (auto mode) or through the bag
  • (manual mode) Manual ventilation through the external fresh gas outlet for non-rebreathing systems (Bain, Mapleson, ...)
Application field: Neonates, Pediatrics & Adults
  • Tidal volume - 5 to 1500 mL
  • Inspiratory pressure - 0 to 68 hPa
  • Ventilation frequency ­- 3 to 120/min
  • Inspiratory time - 0.05 to 16.6s
  • l:E ratio - 5:1 to 1:8
  • Inspiratory pause - 0 to 60%
  • Inspiratory flow - max. 150 L/min
  • PEEP - 0 to 30 hPa
  • Flow trigger - 0.2 to 15 L/min
  • Pressure support - 5 to 50 hPa
  • Ramp time - 0.1 to 2 s
  • Maximum pressure - 0 to 68 hPa
  MONITORING
  • 5" (47 cm) projected capacitive touchscreen, supported on a 360° rotating and 2 axis tilting arm.
  • Measurements displayed: Peak pressure; Plateau pressure; Mean pressure; Expiratory minute ventilation; Expiratory tidal volume; Inspiratory tidal volume; Expiratory volumeter; Breathing rate; Compliance and Resistance (in VC modes); Patient info (age, weight, MAC, Class ASA); Connected sensors; Battery status; Power supply status; Gases supply pressures for 02, N20 and Air; Inspiratory and expiratory concentration of 02, N20, C02 and Anaesthetic gas*
  • Parametres charted as curves (up to 3 simultaneously): Airway pressure; Expiratory flow; Inspiratory flow; Volume; Fresh gases (Rotstyle); Concentration of 02, N20, C02 and Anaesthetic gas*; Trends: Minute volume, MAC and gases (02, N20, C02 and Anaesthetic gas).
  • Display for the performance of the hospital Anaesthetic Gas Scavenging System (AGSS).
  • Configurable interface: bright/dark, multi-language.
  • Loops (up to 2 simultaneously): Volume-Pressure, Flow-Volume, Pressure-Flow, C02-Volume.
  • Fresh gas virtual rotameters for 02, N20, Air. * C02, N20 and Anaesthetic gas monitoring with the accessory multigas analyzer main-stream or side-stream; 02 real-time monitoring via paramagnetic
 
Click Here To Download Catalogue
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare