Mantis CURVE OTW Rotational Pharmacomechanical Thrombectomy System

$0.00

Shipped From Abroad

The Mantis CURVE OTW Rotational Pharmacomechanical Thrombectomy System is an over-the-wire catheter that combines rotational clot fragmentation, aspiration, and local thrombolytic infusion to clear acute or subacute thromboses in peripheral and venous vessels with enhanced clot contact and navigation.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Brands:: Invamed

Description

The Mantis CURVE OTW Rotational Pharmacomechanical Thrombectomy System is a minimally invasive thrombectomy device that merges high-speed rotational disruption with targeted pharmacologic lytic infusion. A curved, sinusoidal tip engages and breaks up large clots while generating a hydrodynamic vortex to help aspirate debris and reduce distal embolization. The over-the-wire (OTW) design accommodates a 0.035″ guidewire for reliable navigation through tortuous anatomy. With multiple catheter sizes and radiopaque construction, it supports efficient removal of thrombi in peripheral or deep venous occlusions.

Key Features
Rotational Pharmacomechanical Thrombectomy
  • Venturi Effect Mechanism: As the active tip spins within the vessel lumen, a hydrodynamic vortex forms, enabling targeted fragmentation and aspiration of the thrombus.
  • Drug Infusion Port: Concurrent infusion of anti-thrombolytic agents ensures cohesive mixing with the thrombus, expediting clot dissolution and clearance.
Active Tip with Coil & Sinusoidal Wave
  • Coil Design: The sinusoidal wave geometry, visible from the distal tip to the proximal region, efficiently engages and fragments the clot.
  • Preventing Distal Embolism: The rotational vortex action, combined with controlled drug release, helps retain clot particles in proximity for prompt removal, reducing the risk of distal migration.
Over-the-Wire (OTW) Catheter System
  • 0.035” Guidewire Compatibility: Simplifies wire management in complex anatomies (including tortuous or large-diameter vessels).
  • Catheter Lengths: With 90 cm and 110 cm functional lengths, and 120 cm or 135 cm profiles, the system accommodates an array of procedural approaches.
Multiple Catheter Profiles & Radiopacity
  • 5.0F to 8.0F: Offers suitable sizing for broad vessel diameters in the peripheral venous circulation, pulmonary artery, or IVC.
  • Radiopaque: The braided shaft is visible under fluoroscopy from the distal tip to the proximal segment, aiding real-time device positioning.
PTFE Inner Lining
  • Low-Friction Catheter Lumen: Streamlines guidewire passage and drug infusion, helping avoid clot or tissue adherence to the catheter walls.
  • Reduced Shear Stress: Minimizes friction on vessel endothelium, supporting safer navigation in high-stakes procedures.
Product Specifications

Specification Detail / Value
Product Name Mantis CURVE OTW Rotational Pharmacomechanical Thrombectomy System
Intended Use Combined mechanical disruption + lytic infusion for acute/subacute thrombosis in peripheral or venous systems
Catheter Design Over-the-wire shaft with curved rotational tip for enhanced clot contact, integrated infusion port
Rotational Speed Range ~40k–80k rpm (verify final)
Infusion Mechanism Side port or multi-hole segment for tPA or lytic agent delivery
Outer Diameter (F) ~5–7F, depending on model
Working Length ~80–120 cm (varies by product code)
Guidewire Compatibility Typically 0.035” (OTW approach)
Sterility Sterile, Single Use
Shelf Life ~2–3 years at 15–25 °C in sealed packaging
Clinical Indications Deep venous thrombosis (DVT), acute peripheral arterial occlusions, possibly for pulmonary thrombosis (per label)
Contraindications Extremely tortuous vessels, heavy calcification, or known device material allergies

Ordering & Size Matrix

Outer Diameter (F) Working Length (cm) Curve Tip Configuration Product Code Notes
5F 80 Moderate Curve MNT-CV-5F-80-MC Smaller lumen, shorter approach
5F 100 Deep Curve MNT-CV-5F-100-DC Extended shaft, deeper curve for better clot contact
6F 80 Moderate Curve MNT-CV-6F-80-MC Common size for peripheral thrombectomy
6F 120 Deep Curve MNT-CV-6F-120-DC Extended length with advanced curve tip
7F 100 Moderate Curve MNT-CV-7F-100-MC Larger lumen for heavier clot burden
7F 120 Deep Curve MNT-CV-7F-120-DC Max length, enhanced curve for extensive occlusions

Reviews

There are no reviews yet.

Be the first to review “Mantis CURVE OTW Rotational Pharmacomechanical Thrombectomy System”

Your email address will not be published. Required fields are marked *

Quick Comparison

Mantis CURVE OTW Rotational Pharmacomechanical Thrombectomy System removeIBIS Neeo R9 Digital Surgical C-Arm removeLED Surtron 200 HP Diathermy Machine removei-gel Supraglottic Airway removeOmron M2 Upper Arm Blood Pressure Monitor Medium Cuff removeElastomeric Pump (Disposable Infusion Pump) with PCA remove
NameMantis CURVE OTW Rotational Pharmacomechanical Thrombectomy System removeIBIS Neeo R9 Digital Surgical C-Arm removeLED Surtron 200 HP Diathermy Machine removei-gel Supraglottic Airway removeOmron M2 Upper Arm Blood Pressure Monitor Medium Cuff removeElastomeric Pump (Disposable Infusion Pump) with PCA remove
ImageIBIS Neeo R9 Digital Surgical C-ArmLED Surtron 200 HP Diathermy MachineOmron M2 Upper Arm Blood Pressure Monitor Medium Cuff
SKUSF1033560011-1SF1033560034-3SF1033560084-76SF1033560084-37SF1033560084-18
Rating
Price

$0.00

$0.00

$0.00

$0.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad The Mantis CURVE OTW Rotational Pharmacomechanical Thrombectomy System is an over-the-wire catheter that combines rotational clot fragmentation, aspiration, and local thrombolytic infusion to clear acute or subacute thromboses in peripheral and venous vessels with enhanced clot contact and navigation.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad Our Neeo “C” arms are easy to place, use and are specifically designed to be used in orthopedics, traumatology, abdominal surgery, urology, cardiology and operating rooms. Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped from Abroad SURTRON 200 is a high frequency electrosurgical equipment which is suitable for light and medium surgery and also allows to execute surgical minimally invasive  procedure of resection, evaporation and coagulation. Delivery & Availability: Typically 10 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
i-gel Supraglottic Airway: The i-gel® is the innovative second generation supraglottic airway device from Inter surgical. The first major development since the laryngeal mask airway, i-gel has changed the face of airway management.
  Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
Omron M2 Upper Arm Blood Pressure Monitor Medium CufF: Omron M2 Upper Arm Blood Pressure Monitor Medium Cuff is a useful tool for clinical management of patients with hypertension. The ease with which using this machine can be learned is a major advantage. zWith this device, you can regularly check your blood pressure level and even get the same consistent accuracy as in your doctor’s office. This digital BP monitor has an arm cuff and a built-in LCD screen to display of the blood pressure readings. A wonderful feature that comes with this monitor is that readings given by the monitor can be stored in the monitor’s memory and can be printed out later.  
  Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock This product make the tension of silicon capsule as the driving force to control the flow by micro porous tube, it was pre-selected by doctor base on patients'situation, and then and then handed over to the patients ' self- management “to relieve or ease the pain

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
ContentThe Mantis CURVE OTW Rotational Pharmacomechanical Thrombectomy System is a minimally invasive thrombectomy device that merges high-speed rotational disruption with targeted pharmacologic lytic infusion. A curved, sinusoidal tip engages and breaks up large clots while generating a hydrodynamic vortex to help aspirate debris and reduce distal embolization. The over-the-wire (OTW) design accommodates a 0.035″ guidewire for reliable navigation through tortuous anatomy. With multiple catheter sizes and radiopaque construction, it supports efficient removal of thrombi in peripheral or deep venous occlusions.
Key Features
Rotational Pharmacomechanical Thrombectomy
  • Venturi Effect Mechanism: As the active tip spins within the vessel lumen, a hydrodynamic vortex forms, enabling targeted fragmentation and aspiration of the thrombus.
  • Drug Infusion Port: Concurrent infusion of anti-thrombolytic agents ensures cohesive mixing with the thrombus, expediting clot dissolution and clearance.
Active Tip with Coil & Sinusoidal Wave
  • Coil Design: The sinusoidal wave geometry, visible from the distal tip to the proximal region, efficiently engages and fragments the clot.
  • Preventing Distal Embolism: The rotational vortex action, combined with controlled drug release, helps retain clot particles in proximity for prompt removal, reducing the risk of distal migration.
Over-the-Wire (OTW) Catheter System
  • 0.035” Guidewire Compatibility: Simplifies wire management in complex anatomies (including tortuous or large-diameter vessels).
  • Catheter Lengths: With 90 cm and 110 cm functional lengths, and 120 cm or 135 cm profiles, the system accommodates an array of procedural approaches.
Multiple Catheter Profiles & Radiopacity
  • 5.0F to 8.0F: Offers suitable sizing for broad vessel diameters in the peripheral venous circulation, pulmonary artery, or IVC.
  • Radiopaque: The braided shaft is visible under fluoroscopy from the distal tip to the proximal segment, aiding real-time device positioning.
PTFE Inner Lining
  • Low-Friction Catheter Lumen: Streamlines guidewire passage and drug infusion, helping avoid clot or tissue adherence to the catheter walls.
  • Reduced Shear Stress: Minimizes friction on vessel endothelium, supporting safer navigation in high-stakes procedures.
Product Specifications
Specification Detail / Value
Product Name Mantis CURVE OTW Rotational Pharmacomechanical Thrombectomy System
Intended Use Combined mechanical disruption + lytic infusion for acute/subacute thrombosis in peripheral or venous systems
Catheter Design Over-the-wire shaft with curved rotational tip for enhanced clot contact, integrated infusion port
Rotational Speed Range ~40k–80k rpm (verify final)
Infusion Mechanism Side port or multi-hole segment for tPA or lytic agent delivery
Outer Diameter (F) ~5–7F, depending on model
Working Length ~80–120 cm (varies by product code)
Guidewire Compatibility Typically 0.035” (OTW approach)
Sterility Sterile, Single Use
Shelf Life ~2–3 years at 15–25 °C in sealed packaging
Clinical Indications Deep venous thrombosis (DVT), acute peripheral arterial occlusions, possibly for pulmonary thrombosis (per label)
Contraindications Extremely tortuous vessels, heavy calcification, or known device material allergies

Ordering & Size Matrix

Outer Diameter (F) Working Length (cm) Curve Tip Configuration Product Code Notes
5F 80 Moderate Curve MNT-CV-5F-80-MC Smaller lumen, shorter approach
5F 100 Deep Curve MNT-CV-5F-100-DC Extended shaft, deeper curve for better clot contact
6F 80 Moderate Curve MNT-CV-6F-80-MC Common size for peripheral thrombectomy
6F 120 Deep Curve MNT-CV-6F-120-DC Extended length with advanced curve tip
7F 100 Moderate Curve MNT-CV-7F-100-MC Larger lumen for heavier clot burden
7F 120 Deep Curve MNT-CV-7F-120-DC Max length, enhanced curve for extensive occlusions
Our Neeo “C” arms are easy to place, use and are specifically designed to be used in orthopedics, traumatology, abdominal surgery, urology, cardiology and operating rooms. Using Neeo with the RTP (Real Time Processing) option it is possible to perform vascular, urological and cardiological diagnostics. One of the main functions, digital image subtraction, allows to see, as an example, the passage of contrast liquids in a tissue or in a venous or arterial duct; thanks to the possibility of looping, the acquired video can be reproduced several times to monitor more accurately the passage of the fluid within the area in question. Angiographic measurement is another useful function in the vascular field (QA Quantitative Angiography) that allows the measurement of stenoses. Finally, fluoroscopy allows the correct positioning of stents or expanders. Neeo is used in various interventional and diagnostic procedures in traumatology and orthopedics wards and operating rooms as well. Thanks to low-dose fluoroscopy, it is possible to use the device for positioning bone or subcutaneous grafts, inserting K-wire (Kirschner wire) for stabilization of bone fragments or for the correct positioning of prostheses. The low dose emitted ensures safe use for both the patient and the surgeon or doctor on the operating field. On the control panel there is a large touch screen display that allows to adjust the basic functions of the equipment. From this display it is possible to select and adjust the fluoroscopic data for the examination, activate or deactivate the laser pointer, select between pulsed, one shot or standard fluoroscopy, rotate the image and perform all operations on collimator. The four side buttons on the display offer the possibility to move the bow vertically thanks to an extremely silent motor. Neeo has two 19 “medical grade monitors that can be positioned according to the needs of the medical practitioner. Work monitors and feedback monitors are separated to be managed independently. The possible movements are: rotation, revolution, tilting and possibility of height adjustment. Features:
  • Continuous fluoroscopy
  • Pulsed fluorography
  • One Shot fluoroscopy
  • Low dose fluoroscopy
  • Radiography with cassette (up to 5KW)
  • 110,000 images of memory (Standard)
  • 19 ″ Medical Flat Monitor (X2)
  • Touch control panel
  • Image Processing – 1K X 1K, 16 bit
  • DAP-Dose Area Meter
  • DSA Road Mapping
  • Laser Marker
Technical Specification:
  • Power: 5KW
  • kV Range (kV): 40 - 120
  • mAs Range (mAs): 1 - 250
  • SID (mm): 1000
  • Free Space (mm): 730
DICOM Feature:
  • RTP-SW DSA
  • RTP-SW QA
  • RTP-SW Worklist
  • RTP-SW Print
  • RTP-SW CD DVD Saving
  • RTP-SW MPPS
  • RTP-SW Query/Retrieve
  • RTP-SW HCF
  • RTP-SW BASE
  • RTP-SW STCOMMIT
Configuration: C-Arm Structure, Trolley for Monitor, Collimator, Monoblock, Toshiba 12” Image Intensifier, 19″ Philips Medical Flat Monitor (X2), Camera CD1030CA 1KX1K, Sony Printer UP-X898MD, Cassette Holder
Click Here To Download Catalogue
SURTRON 200 is a high frequency electrosurgical equipment which is suitable to light and medium surgery. SURTRON 200 allows to execute surgical minimally invasive  procedure of resection, evaporation and coagulation. Through its performances, SURTRON 200, allows pure CUT,  cut-coagulation BLEND, incision with reduced prodution of eschar ENHANCED, superficial coagulation FORCED COAG, deep coagulation in absence of necrosis SOFT COAG and BIPOLAR coagulation. The digital reading of the delivered power and the overseeing through microcontroller of the operational functions, assure the absolute reliability of the conditions of job. SURTRON 200 allows a highly professional surgery thanks to the user-friendly and safety solutions normally used. The connection of neutral electrode is constantly monitored. Safety control of patient/plate contact using split neutral electrode. The possibility to control by the handle the output functions as well as the delivery of output power, allows to implement the surgical operation without turning away the surgeon attention from the surgical field. FEATURES Code 10100.401 Max output power CUT: 200W – 250Ω Max output power ENHANCED: 120W – 250Ω Max output power BLEND: 120W – 200Ω Max output power FORCED COAG: 150W – 150Ω Max output power SOFT COAG: 90W – 100Ω Max output power BIPOLAR COAG: 80W – 50Ω Working frequency: 600 kHz Patient circuit: F Mains voltage: 115-230 Vac Mains frequency: 50-60 Hz Electrical input power: 350 VA Size WxHxD: 370x144x319 mm Weight: 6 Kgs CONTROLS Patient/Plate circuit monitoring Output power monitoring Self check control SAFETY EN60601-1 EN60601-1-2 EN60601-2-2 Electrical classification: CF MDD 93/42 / EC: II b  
Click Here To Download Catalogue
i-gel Supraglottic Airway: The i-gel® is the innovative second generation supraglottic airway device from Intersurgical. The first major development since the laryngeal mask airway, i-gel has changed the face of airway management. Features: i-gel has a soft, gel-like, non-inflatable cuff, designed to provide an anatomical impression fit over the laryngeal inlet. The shape, softness and contours accurately mirror the perilaryngeal anatomy - an innovative concept meaning no cuff inflation is required. Working in harmony with the patient's anatomy, compression and displacement trauma are significantly reduced or eliminated.
Omron M2 Upper Arm Blood Pressure Monitor Medium Cuff: Omron M2 Upper Arm Blood Pressure Monitor Medium Cuff is a useful tool for clinical management of patients with hypertension. The ease with which using this machine can be learned is a major advantage.With this device, you can regularly check your blood pressure level and even get the same consistent accuracy as in your doctor’s office. This digital BP monitor has an arm cuff and a built-in LCD screen to display of the blood pressure readings. A wonderful feature that comes with this monitor is that readings given by the monitor can be stored in the monitor’s memory and can be printed out later.
  Features:
  • Fully automatic upper arm blood pressure monitor
  • Intellisense™ technology
  • Hypertension level indicator
  • Irregular heartbeat detection
  • Memory capacity for 21 readings with date and time stamp
  • Cuff wrapping guide
  • Clinically validated (International Protocol)
 
This product make the tension of silicon capsule as the driving force to control the flow by micro porous tube, it was pre-selected by doctor base on patients'situation, and then and then handed over to the patients ' self- management “to relieve or ease the pain Product Components: one-way valve medicated device, elastic liquid storage device, liquid medicine filter, current limiting device, automatic liquid feeding device ( CBI & PCA ), pipe and the external connector; Product Features: 1. The continued to liquid (CBI) make the drug-stored sac mechanical stretch as a driving force, limited the flow through the micro porous tube to the patient safely, effectively, slightly, continuous uniform injection of liquid to analgesic effect; extrusion pump body does not affect the liquid normal velocity; liquid filtering device which can control the particles enter the body better; 2. Continued to liquid + self control to liquid ( CBI+PCA ) make the drug-stored sac mechanical stretch as a driving force, limited the flow through the micro porous tube to the patient safely, effectively, slightly, continuous uniform injection of liquid to analgesic effect; Automatic medicated function is the patients can medicate according to pain independently. Extrusion pump body does not affect the liquid normal velocity; liquid filtering device which can control the particles enter the body better; How to use: 1. Get analgesia pump out from sterile packaging, removing the cap of medicine inlet and outlet; pour the analgesic liquid in the liquid storage device, draw out the air from the liquid storage. 2. Finish medicating, waiting for the liquid outflow from the medicine outlet; please clamp tightly to stop flowing for preparation. 3. Control keys (PCA key) is a function key to add the medicine base on continue to medicated by patients' self-controlled. So the patients can self-control the PCA key under the guidance of doctors, according to the needs while they are in treatment. At the same time, doctor should fill in PCA treatment card, so that they can analyze the condition from PCA additional times.
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare