The OBS-100B Cold Bipolar Coagulator is a precision electrosurgical device designed for delicate surgeries. It ensures minimal tissue irritation, offers a non-stick effect, and operates without sparking, making it ideal for microsurgical applications like neurosurgery and ophthalmology.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
The OBS-100B Cold Bipolar Coagulator is a precision electrosurgical device designed for delicate surgeries. It ensures minimal tissue irritation, offers a non-stick effect, and operates without sparking, making it ideal for microsurgical applications like neurosurgery and ophthalmology.
Delivery & Availability:Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability:Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
The OBS-350A LCD Version Electrosurgical Generator is a versatile medical device used in various surgical procedures. It provides up to 350W of cutting power and 150W of coagulating power, operating at a frequency of 417 kHz. Featuring both monopolar and bipolar modes, it offers 8 working modes, including pure cut and bipolar vessel sealing. The device has a user-friendly LCD display and can store up to 10 presets for quick access. It's suitable for surgeries such as general, vascular, laparoscopic, and gynecological procedures.
Delivery & Availability:Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
This unit is widely used in many different sectors including plastic surgery, dermatology, ENT, Ophthalmology, somatology, gynecology, proctology, and urology.
Delivery & Availability:Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Unique dual radio frequency design. Combines 4Mhz and 1.7Mhz into one generator. Realizes the best operation result effectively. Suitable for Plastic, Dermatology, ENT, Ophthalmology, Dentistry, Podiatry and Spinal surgery
Delivery & Availability:Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From AbroadElectrosurgical Pad, also known as a dispersive electrode or grounding pad, is a crucial component used in electrosurgery. It helps to complete the electrical circuit by dispersing the electrical current away from the patient's body, ensuring the safety and effective operation of the electrosurgical unit (ESU)
Delivery & Availability:Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Features
Low voltage output: Ensures minimal irritation to neuromuscular tissues.
Suitable for microsurgery: Ideal for neurosurgery, ophthalmology, gynecology, and plastic surgery
Features
1. Intended for ablation,tissue modification, and coagulation of soft tissue in arthroscopic procedures such as hip, shoulder, ankle, wrist, elbow, and knee.
2. The Extending shaft enables good visualization and easy insertion through subcutaneous tissue,and well insulated coating guarantee its safety and reliability.
3.Irrigation/suction solution is available with a cannula and an adjustable flow control valve.
4. Tips in different shapes and angles fit in particular arthroscopic procedures.
5. Compatible with most electrosurgical generators.
Use Indication
This device should never be used when:
There is visible evidence of damage to the exterior of the device such as cracked or damaged plastic or connector damage.
These devices fail the inspection described herein.
In the presence of flammable gases, flammable prep solutions or drapes. Oxidizing. Gases such as Nitrous Oxide (N2O), or in oxygen-riched environments.
Do not use monopolar electrosurgery on small appendages, as in circumcision or finger surgery.
Features
Power: It offers cutting power up to 350W and coagulating power up to 150W.
Frequency: Operates at 417 kHz.
Applications: Suitable for general surgery, vascular surgery, hepatobiliary and pancreatic surgery, cardiothoracic surgery, gastroenterology, TURP (Transurethral Resection of the Prostate), TUVP (Transurethral Vaporization of the Prostate), and compatible with cystoscopy, arthroscopy, laparoscopy, and hysteroscopy.
Modes: It has 8 different working modes including pure cut, blend, coagulation, and bipolar vessel sealing.
Display: Features a 7-segment LED display for easy monitoring.
Presets: Comes with 10 saved presets for quick access
Monopolar and Bipolar Modes: This device supports both monopolar and bipolar modes, offering flexibility for various surgical needs.
User-friendly Interface: The intuitive LCD display provides real-time feedback and easy control settings, enhancing the precision and efficiency of surgical procedures.
Safety Features: It includes automatic self-checking systems and alarms for safety, ensuring reliable performance during operations.
Memory Function: You can save and recall up to 10 presets, allowing for quick setup and operation tailored to specific surgical requirements.
Efficient Smoke Evacuation: Integrated smoke evacuation system helps maintain a clear surgical field and improves visibility.
Technical Specifications
Cutting Power: Up to 350W
Coagulating Power: Up to 150W
Frequency: 417 kHz
Power Supply: AC 100-240V, 50/60Hz
Dimensions: 380mm x 280mm x 120mm
Weight: Approximately 6kg
Applications
General Surgery: Versatile for cutting and coagulating tissue.
Vascular Surgery: Precise control for delicate procedures.
Laparoscopy: Compatible with minimally invasive surgical techniques.
Hysteroscopy: Suitable for gynecological procedures.
The OBS-50 is a market leader across the world due to its ease of use, high security, power on self test, full-range monitoring, remote control and precise output.
Power output can be controlled by the easy to use power adjustment button on the electrosurgical hand pencil which can shorten the operation time.
With the inbuilt memory function on the device, you can set the required function parameters then power off the unit, next time the unit is powered on, the unit the last set parameter will be displayed.
Output power of between 10 and 30 watts or less can be adjusted up and down by 0.1-watt increments, which is suitable for various delicate procedures.
It can be used with disposable dispersive electrode
What's in the box?
x1 OBS-50 High-Frequency Electric Coagulator Unit
x1 Reusable power control electrosurgical pencil
x10 Non-Sterile Single-Use Short Sharp Tips
x10 Non-Sterile Single-Use Short Blunt Tips
x1 Power cord
x1 Instruction manual
Multiple Applications to meet your different clinic demands
Desiccation
Monopolar output mode without using the dispersive electrode
Contact or insert into the tissue with the electrode
The unit produces a high-frequency current, which runs through the patient via the electrode and then returns to the unit through grounding.
High-frequency current vaporises the liquid inside the tissue cell therefore causing denaturation on the protein
Fulguration
Another monopoly output mode without using a dispersive electrode
Holding the electrode above the lesions rather than contact directly, will release an electric arc to the tissue.
Range of action in this mode is limited to the surface where the arc contacts the tissue
Coagulation
Suitable for hemostasis and shrinkage of tissue
Used in control of hemostasis
Suitable for more difficult cutting procedures for good hemostasis
Monopolar coagulation
Monopolar output mode using the dispersive electrode
Under this mode, the high-frequency current that is produced from the unit flows through the patient and then returns to the unit via a dispersive electrode
The dispense electrode can draw more high-frequency current to the electrode, making the tip of electrode produce a more powerful desiccation to the tissue.
Bipolar Coagulation
An Output mode in which the high-frequency current circulates between two nearby electrodes (bipolar forceps), without using the dispersive electrode.
In contrast to the effect of monopolar coagulation, since the high-frequency current is only circulated separately in the forceps, the bipolar coagulation effect acts only on the tissue surface, causing minimal damage to the tissue.
Standard Accessories (Can be purchased Separately)
Clinic result proves that higher frequency can get less tissue resists nee. 4Mhz frequency can reduces heat injury a ind carbonizing to tissue at maximum. It realizes low temperature cutting.
The antenna pad is unnecessary for skin touch, no current goes through the body, and no possibility of burning
No pressure cutting and the pencil is operated easily and it's full of flexibility.
No carbonation, less bleeding, and no adhesions.
Less pain, scarring, and fast healing after operation.
Technical Parameters
Product Details
OUTPUT MODE
CUT - For micro-smooth cutting
BLEND - For cutting with coagulation
HEMO - For pure Hemostasis-Coagulation to control most forms of bleeding
FULGURATION - For desiccation or fulgurate spark-gap
BIPOLAR - For precise coagulation utilizing bipolar energy
INTENDED USE
Cutting: snoring, submucosal palatal shrinkage, traditional uvulopalatoplasty (RAUP), myringotomy with effective hemorrhage control, epistaxis treatment, turbinate shrinkage, skin incisions, biopsy, cysts, abscesses, tumors, cosmetic repairs, development of skin flaps, skin tags and blepharoplasty.
Blended (cutting and coagulation): snoring, submucosal palatal shrinkage, traditional uvulopalatoplasty (RAUP), myringotomy with effective hemorrhage control, epistaxis treatment, turbinate shrinkage, skin tags, papilloma keloids, keratosis, verrucae. basal cell carcinoma, nevi, fistulas, epithelioma, cosmetic repairs, cysts, abscesses, and development of skin flaps.
Hemostasis: control of bleeding, epilation, telangiectasia.
Bipolar: pinpoint precise coagulation, pinpoint hemostasis in any field (wet or dry), snoring, submucosal palatal shrinkage, traditional uvulopalatoplasty (RAUP), myringotomy with effective hemorrhage control, epistaxis treatment and turbinate shrinkage.
Reusable Fine Electrode tips (Needle, curved, Needle .Ball): 7pcs
Disposable leep Electrode tips: 5pcs
Features:
High Conductivity: They are made from materials that ensure efficient conduction of electrical current.
Large Surface Area: This helps in dispersing the current over a wide area, reducing the risk of burns.
Adhesive Backing: They usually have an adhesive side to securely attach to the patient's skin.
Flexible Design: They are designed to conform to the contours of the patient's body.
Safety Mechanisms: Modern pads often include features like dual-pad return electrodes for fail-safe operation.
Uses:
Completing the Electrical Circuit: They act as a return path for the electrical current used in electrosurgery.
Minimizing Burns: By dispersing the current, they help prevent burns at the surgical site.
Ensuring Patient Safety: They are crucial for the safe operation of electrosurgical units, especially in patients with electronic implants like pacemakers.
Versatile Applications: Used in various surgical procedures, including cutting, coagulating, and desiccating tissue.
Reviews
There are no reviews yet.