| Description | Shipped From Abroad
The SHE-LSP200 is a mid-range picosecond Nd:YAG laser delivering trillionth-of-a-second pulses—ideal for treating pigmentation, tattoos, and vascular spots.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| In stock
Dimension (mm): L550 x W420 x H880 mm
Color: Grey
Material: Stainless steel
No of wheel: 4
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped from abroad
The Neuropack S3 combines Nihon Kohden’s gold-standard amplifiers with time-saving and easy-to-use clinical software, bringing neurodiagnostic labs a feature-rich system that provides cleaner, easier and faster data. The foundation of effective neurodiagnostic testing is a system that can provide a full complement of neurodiagnostic tests while also offering the quality needed to analyze and monitor nervous system function.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped from Abroad
The Genesis anaesthesia workstations meet your most ambitious requirements. They stand out for their lung protective ventilation.
Application Field: Neonates, Pediatrics & Adults
Ventilation Modes: Volume controlled (VC), Pressure controlled (PC), Adaptive Pressure with Volume Guaranteed (APVG) & Pressure Support Ventilation (PSV)
Delivery & Availability:
Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
Needle destruction destroy the needle immediately following its use. Needle destruction are an absolute necessity in developing parts of the world to prevent the reuse of needles and the spread of bloodborne pathogens. They are NOT a good alternative, however, for hospital use in the developed parts of the world. Needle destruction are products that bend, cut, or destroy the needle. This are distinctly different from needle destroyer that send an arc of electricity to vaporize and melt the needle.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
Used for Clinical Diagnostics.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. |
| Content | Product Description
The Picosecond ND YAG Laser-SHE-LSP200 is a mid-range picosecond Nd:YAG laser delivering trillionth-of-a-second pulses—ideal for treating pigmentation, tattoos, and vascular spots. It utilizes high-energy, ultrashort pulses to shatter pigment while preserving surrounding tissue.
Key Features
-
Picosecond Pulse Technology: Emphasizes impurity shattering in a few sessions.
-
Dual-Pulse Capability: Works in single or double pulse modes for treatment flexibility.
-
Multi-Wavelength Options (e.g., 1064 nm / 532 nm): Targets both deep and surface-level pigmentation.
-
Efficient Photoacoustic Effect: Breaks pigment effectively via Nd:YAG explosion mechanism.
-
Ergonomic Controls: 10.4″ TFT touchscreen with a 7-joint articulated arm for precise targeting.
-
Dual Cooling System: Combines air and water cooling to maintain performance.
|
| Dimension (mm) |
L550 x W420 x H880 mm |
| Color |
Grey |
| Material |
Stainless steel |
| No of wheel |
4 |
| The Neuropack S3 combines Nihon Kohden’s gold-standard amplifiers with time-saving and easy-to-use clinical software, bringing neurodiagnostic labs a feature-rich system that provides cleaner, easier and faster data. The foundation of effective neurodiagnostic testing is a system that can provide a full complement of neurodiagnostic tests while also offering the quality needed to analyze and monitor nervous system function.
Features:
- State-of-the-art low-noise amplifier with 18-bit A/D converters and artifact-reduction software provides clean waveforms
- Built-in rejection ratios of 110 dB or greater (differential mode) and 112 dB or greater (isolation mode) limit variations in signals
- Electrode input impedance of 200 MΩ ±20% helps ensure clean signals
- On-screen examination guide directs electrode and stimulation placement for smooth and efficient examinations
- HL7® gateway integration helps ensure quick flow of information and streamlines workflow
- Intuitive control panel and stimulators aid in acquiring and progressing through studies
- Customizable protocols shorten examination time
- One-click report generation produces print-ready reports with customized logos, test results, exam waveforms and highlighted abnormal values
- Proprietary all-in-one NCS program performs MCS, SCS and F-wave for quick examinations
- Customized auto-copy settings allow waveforms to be stored and automatically transferred to long-term storage
Technical Specifications:
Main unit: DC-960B
Electrode junction box, 2 or 4 ch: JB-962B or JB-964B
Control unit, desktop: GG-961BK
Power supply: SC-230BK
Cart: KD-026A
Arm: KH-960A
Holder: DI-961B
Somato control box: RY-960B
LCD display: Local purchase
Printer: Local purchase
Number of channels: 2 or 4
Input impedance Common mode: >100 MΩ
Differential Mode: >200 MΩ
CMRR Differential Mode: >106 dB
Isolation Mode: >112 dB
Noise level: 0.6 μVrms
Sampling Resolution: 18 bit
Sensitivity: 1 to 500 μVrms/div., and 1 to 10 mVrms/div.
Low-cut filter: 0.01 Hz to 3 kHz
High-cut filter: 10 kHz to 20 kHz
Analysis time base: 0.1 ms/div to 1 s /div
Model Suffixes
EEG-1200 has the following suffixies:
J: 110-127 V AC operation
K: 220-240 V AC operation
| The Genesis anaesthesia workstations meet your most ambitious requirements. They stand out for their lung protective ventilation, accuracy and performance, cost saving, design and ergonomics, safety and versatility.
TECHNICAL SPECIFICATION
OPERATING DATA
- Weight - 105 kg
- Dimensions - 92 cm Wide x 68 cm Deep x 139 cm High (93 cm to the table surface)
- Packaging Dimensions - 105 cm Wide x 75 cm Deep x 160 cm High
- Operating voltage supply - 110 to 240 V~, 47 to 63 Hz (12 to 6 A)
- Power input - 120 W typically (max. 1.2 kW with auxiliary outlets used)
- Battery autonomy - 90 min typically
- Auxiliary power outlets - 4, with automatic protection
- O2, N2O and Air supply - 2.7 to 6.9 bar (39.1 to 100 psi)
- Screen - TFT 18.5" (47 cm) projected capacitive touchscreen
- Protection class - Class I, gas analyser type BF defibrillation proof
- Classification - Class II b
- Storage - One front drawer with self-brake system and two back cabinets with door
- Lighting - LED bar below the screen controlled from the touchscreen
- Auxiliary integrated systems - Auxiliary 02 flow meter (0-15 L/min), Auxiliary 02 suppy valve (NF standard) and Suction device
- Communication ports - 1 x RS-232, 2 x USB, 1 x LAN Ethernet
Fresh Gases (02, N20 and Air, electronically controlled)
- Fresh gas flow - 0 and 0.1 to 18 L/min 02/N20/Air
- Accuracy - 0.1 to 0.5 L/min = ±0.05 L/min; 0.5 to 18 L/min = ±10 %
- 02 concentration - 21 to 100% vol. with Air, 25 to 100% with N20 (minimum 200 ml/min 02)
- 02 Safety fresh gas (backup) - 0-0.2-0.4-0.7-1-1.5- 2- 3- 4- 6- 8-10-12-15 L/min 02
- 02 flush (+02) - 40 L/min standard (adjustable 25 - 75 L/min upon requirement)
Breathing System (CABS)
- Autoclavable - 134 °C
- Weight of breathing system - 9.8 kg
- C02 absorber volume - 1.5 L
- Leakage - < 150 mL/min (at 30 hPa)
- Pressure limiting valve APL - 0 to 70 hPa
- Pressure relief valve - 125 hPa
- Vacuum safety valve - 0.3 hPa
- resistance at 60L/min - 5.80 hPa
- resistance at 60L/min - 2.90 hPa
- resistance at 30L/min - 3.55 hPa
- resistance at 30L/min - 0.89 hPa
- Internal Compliance at 30 hPa - 15 mL
VENTILATOR
Operation / Ventilation Modes
Volume controlled (VC) modes:
- Volume Controlled Ventilation (VCV)
- VC Synchronized Intermittent Mandatory Ventilation (VC-SIMV)
- VC-SIMV with Pressure Support (VC-SIMV-PS) *
Pressure controlled (PC) modes:
- Pressure Controlled Ventilation (PCV)
- PC Synchronized Intermittent Mandatory (PC-SIMV)
- PC-SIMV with Pressure Support (PC-SIMV-PS) *
Adaptive Pressure with Volume Guaranteed (APVG) modes (other trade names: Autoflow,PCVR, PRVC, AVAPS, VC+)
- Adaptive Pressure with Volume Guaranteed (APVG) *
- APVG Synchronized Intermittent Mandatory (APVG-SIMV) *
- APVG -SIMV with Pressure Support (APVG-SIMV-PS) *
Pressure Support Ventilation (PSV) *
- (other trade names: PS, ASB, SPS, IPS)
Non-mechanical Operation / Ventilation Modes
- Manual ventilation through the CABS system (Auto/Manual software controlled)
- Spontaneous ventilation either through the bellows (auto mode) or through the bag
- (manual mode) Manual ventilation through the external fresh gas outlet for non-rebreathing systems (Bain, Mapleson, ...)
Application field: Neonates, Pediatrics & Adults
- Tidal volume - 5 to 1500 mL
- Inspiratory pressure - 0 to 68 hPa
- Ventilation frequency - 3 to 120/min
- Inspiratory time - 0.05 to 16.6s
- l:E ratio - 5:1 to 1:8
- Inspiratory pause - 0 to 60%
- Inspiratory flow - max. 150 L/min
- PEEP - 0 to 30 hPa
- Flow trigger - 0.2 to 15 L/min
- Pressure support - 5 to 50 hPa
- Ramp time - 0.1 to 2 s
- Maximum pressure - 0 to 68 hPa
MONITORING
- 5" (47 cm) projected capacitive touchscreen, supported on a 360° rotating and 2 axis tilting arm.
- Measurements displayed: Peak pressure; Plateau pressure; Mean pressure; Expiratory minute ventilation; Expiratory tidal volume; Inspiratory tidal volume; Expiratory volumeter; Breathing rate; Compliance and Resistance (in VC modes); Patient info (age, weight, MAC, Class ASA); Connected sensors; Battery status; Power supply status; Gases supply pressures for 02, N20 and Air; Inspiratory and expiratory concentration of 02, N20, C02 and Anaesthetic gas*
- Parametres charted as curves (up to 3 simultaneously): Airway pressure; Expiratory flow; Inspiratory flow; Volume; Fresh gases (Rotstyle); Concentration of 02, N20, C02 and Anaesthetic gas*; Trends: Minute volume, MAC and gases (02, N20, C02 and Anaesthetic gas).
- Display for the performance of the hospital Anaesthetic Gas Scavenging System (AGSS).
- Configurable interface: bright/dark, multi-language.
- Loops (up to 2 simultaneously): Volume-Pressure, Flow-Volume, Pressure-Flow, C02-Volume.
- Fresh gas virtual rotameters for 02, N20, Air. * C02, N20 and Anaesthetic gas monitoring with the accessory multigas analyzer main-stream or side-stream; 02 real-time monitoring via paramagnetic
| Needle destruction destroys the needle immediately following its use. Needle destruction are an absolute necessity in developing parts of the world to prevent the reuse of needles and the spread of bloodborne pathogens. They are NOT a good alternative, however, for hospital use in the developed parts of the world. Needle destruction are products that bend, cut, or destroy the needle. This are distinctly different from needle destroyer that send an arc of electricity to vaporize and melt the needle.
Features:
- Well built
- Easy to maintain
- Having a rubbish drawer with alarm function, this is our most popular model of Syringe Destroyer for use in labs, pharma, universities and doctors clinics
- With its low factory-direct price and excellent quality, its a great addition to add to any medical industry or university office that wants to ensure the safety and legal compliance of its operations
Specifications:
- Short Name: Needle destruction / Needle Destroyer
- Working Noise: ≤50 decibel
- Superheating Sanitization Temperature: 95 deg C
- Working Time: Can completely melt and destroy needle and neck of syringe in 5 seconds
- Working Noise: ≤50 decibel
- Dimensions: Approx. 38cm x 29cm x 28cm
- Power: AC 110V or 220V
| Used for Clinical Diagnostics.
- Test Method: Dry Strip color-developing method
- Test Principle: Dual wavelength reflectance photometry
- Light Source: Cold Lamp with high brightness and long lifetime
- Test System: Color-indentify system with high sensitivity and repeatability
- Wavelength: 520nm, 640nm, 660nm
- Throughput: 120 Strips/Hour
- Test Mode: Single and continuous test mode are selectable
- Test Slot: Using sliding Slot, Easy to clean and replace, lower the carryover
- Waste Collection: Waste urine and waste strips can be collected automatically
- Test Strip: Use GENIUS original strips only
- Display: LCD with high brightness and resolution
- Language: Customizable language software
- Memory: Save 2000 samples results, and auto recover the results when power off during working
- Interface: RS-232 serial port, can be connected to external printer and computer Printer: Inner thermal printer, can be connected to external printer
- Report format: Half quantitative and qualitative, report the color and turbidity is available
- Result unit: SI unit and routine unit are selectable
- Status Check: Auto-check the status during power on and off, auto-indentify the alarm
- Working Environment: Temperature10℃~30℃; Humidity: 20%RH~80%RH
- Power: 100-240V, Auto adapt according to the input voltage
- Consumption: ≤80VA
- Quality System: Certified by TUV and CMD
|
Reviews
There are no reviews yet.