| Description | Shipped From Abroad
- INCLIX™ Troponin I quantitatively measures troponin I concentration in whole blood, serum or plasma. using the INCLIX™ analyzer. For in vitro diagnostic use only.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
- Total Volume: 60mL.
- Specimen Container, Leak-proof, Ideal for Pathology/Histology/Cytology reagent pre-filling sample preparation.
- Made of premium PP material, it is durable for usage.
- Some measurements can be used to not only use urine samples, it can also be used for other liquids.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
| Capacity |
500ml |
| Color |
Transparent |
| Material |
Glass |
| Application |
Chemical Laboratory |
| Heat Resistant |
Yes |
| Pack Type |
Box |
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped from Abroad
GEMINI offers cost-savings, safety and a high degree of flexibility enabling a smooth laboratory workflow, thus making it a powerful system for all.
FEATURES
- Ease of use in application and maintenance
- Designed with sample and reagent ID-barcode reading, in-tip dilution reducing consumable costs
- Intuitive and highly flexible open software with complete data reduction and LIS interfaces
- Integrated PC and touchscreen eliminates the need for an external workstation
- Smart time-management allows processing up to 3 microplates simultaneously
Delivery & Availability:
Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
The Discover Cup is an all-in-one drug of abuse test cup. The strips are self contained and the entire cup is tamper resistant.
Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped From Aboard
The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.
Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. |
| Content |
- INCLIX™ Troponin I quantitatively measures troponin I concentration in whole blood, serum or plasma. using the INCLIX™ analyzer. For in vitro diagnostic use only.
- Cardiac troponin I (Tn I) is a protein found in myocardial muscle and the most sensitive biomarker for detection of acute myocardial infarction (AMI).The concentration of Tn I in the healthy human is below about 0.5 ng/ml and the level of Tn I is increased within 4-6 hours after the onset of chest pain. After cardiac injury occurs, peak in approximately 8 to 28 hours, and remain elevated for 3 to 10 days following AMI. The Tn I test is well known to be an important prognostic indicator of heart disease.
- The Tn I Test is based on immunochromatography technology. When the sample is loaded to the device, the detection antibody which is conjugated with the colloidal gold in the dried pad binds to Tn I and flows through the membrane. The detection antibody-gold conjugate and Tn I move to the test line area and are accumulated by the capture antibody immobilized on the membrane. This leads to the generation of a reddish colored band. The intensity of the band depends on quantity of Tn I molecules and is analyzed by INCLIX™ analyzer for quantitative readout
|
- Total Volume: 60mL.
- Specimen Container, Leak-proof, Ideal for Pathology/Histology/Cytology reagent pre-filling sample preparation.
- Made of premium PP material, it is durable for usage.
- Some measurements can be used to not only use urine samples, it can also be used for other liquids.
|
- Outside Dia.: 87mm
- Material of Construction: Glass
- Capacity: 500mL
- Labware Outside Dia. - English: 3.4"
- Labware Capacity - English: 16.9 oz.
- Graduation Range: 100 to 500mL
- Height: 118mm
- Disposable/ Reusable: Reusable
- Labware Body Color: Clear
- Graduation Subdivisions: 100ml
- Beaker Type: Low Form
- Labware Outside Dia. - Metric: 87mm
- Series: Hauler 4x4 Crew Diesel
- Special Features: Pouring Spout
- Labware Inside Dia. - English: 3.2"
- Sterile/Non-Sterile: Non-Sterile
- Labware Inside Dia. - Metric: 81mm
- Labware Body Material: Glass
- Color: Clear
- Labware Height - English: 4.6"
- Labware Height - Metric: 118mm
- Labware Basic Material: Glass
- Item: Low Form Beaker
- Glassware Class: Not Rated
- Graduations: Yes
- Labware Capacity - Metric: 500mL
- Autoclavable: Yes
| GEMINI offers cost-savings, safety and a high degree of flexibility enabling a smooth laboratory workflow, thus making it a powerful system for all.
FEATURES
- Ease of use in application and maintenance
- Designed with sample and reagent ID-barcode reading, in-tip dilution reducing consumable costs
- Intuitive and highly flexible open software with complete data reduction and LIS interfaces
- Integrated PC and touchscreen eliminates the need for an external workstation
- Smart time-management allows processing up to 3 microplates simultaneously
SPECIFIATIONS
Reader
- Photometric range: 0 to 3.0 OD
- Spectral range: 400 nm to 700 nm (up to 8 filters)
- Read time: < 15 sec single, < 30 sec dual
- Precision: 1% CV at 1.0 OD
- Accuracy: ±0.005 OD or 2.5 % (whichever is greater)
- Linearity: 0 to 2.000 OD ±1 %
Pipettor
- Min / max. volumes: 10 µl to 300 µl with 300 µl tip, 301 µl to 1000 µl with 1100 µl tip
- Precision (single dispense): < 3 % CV at 20 µl, < 3 % CV at 100 µl
- Precision (multi dispense): < 10 % CV at 16 x 20 µl, < 3 % CV at 8 x 100 µl
- Features: Pipetting pressure monitoring, capacitive liquid level detection, tip detection, mixing, multiple dilution steps, archiving
Capacity
- Sample and reagent capacity: Up to 192 samples (Flexible: e.g. 144 samples + 8 reagents + 16 controls)
Incubator
- Temperature range: Up to 45 °C
- Temperature uniformity: ±1.5 °C (with in-process temperature uniformity monitoring)
- Shaking: 20 Hz
Washer
- Precision: 10% CV at 300 µl
- Residual volume: <2.5 µl in U-bottom (mean), <4 µl in flat bottom (mean)
- Wash buffer capacity: 3 wash buffers
- Modes: Sweep mode, soak, top and bottom wash, variable pump speed
Dimensions
- Width x Depth x Height: 125 cm x 65 cm (without waste bag) x 75 cm with closed cover (49” x 26” x 30”)
|
FDA 510(K) & CLIA Waived
Up to 99% accuracy rate
Results in as little as 1 minute
24 Month Shelf Life from Date of Manufacture
Secure, seal and send to lab for confirmation
Built in temperature strip
Available to test up to 17 substances with adulterants or 18 without adulterants
Adulterants available
| The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric
analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.
Feature
- Auto zero function: Manual blanking not required
- Dual wavelength measurement system:
- 2 wave lengths 455nm and 575nm
- Plays major role to remove the interference caused due to Hemolysis & turbidity of sample
- LED Light source:
- LED does not require replacement as it lasts longer
- As compared to Lamp, LED are more suitable as there is no intensity fluctuations
- No warm up time required.
- Flexible unit selection:
- Two units either mg/dl or umol/L are selectable, ease of reporting
- Compact slot for Capillary:
- Accuracy of results are directly related to proper alignment of Capillary
- B-111 has the easiest mode to ensure precise values
- Data transfer:
- External device can be connected to instrument through RS232 por
- USB port
Technical Specification
- Light source - LED
- Wavelength - 455nm and 575nm
- Net weight - 1kg
- Measuring range - 0-30 mg/dl , 510 umol/L
- Display - 16×2 LCD module with backlight
- Auto calibration - Yes
- Sample type - Serum or plasma
- Sample volume - 40-80μL
- Test time - <5sec
- Units - mg/dl or umol/L
- Dimensions - 150 (W) × 115 (H) × 190 (D) mm
- Interface - RS232
- Reading cuvette - Heparinized micro capillary holder
- Storage temperature - 15-40°c
- Power supply - DC 9V(DC adapter)
- Power consumption - <2W
|
Reviews
There are no reviews yet.