/

Viper™ Valved Infusion Catheters

$0.00

Shipped From Abroad

The Viper™ Valved Infusion Catheter is a single-lumenvalved-tip delivery system that offers the flexibility to infuse anti-thrombus agents, radiopaque contrast, or other physician-specified pharmacologic solutions with or without a guidewire in place.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Brands:: Invamed

Description

The Viper™ Valved Infusion Catheter is a single-lumenvalved-tip delivery system that offers the flexibility to infuse anti-thrombus agents, radiopaque contrast, or other physician-specified pharmacologic solutions with or without a guidewire in place. By eliminating the need for a tip-occluding wire during treatment, Viper™ greatly expands the available infusion lumen, allowing higher flow rates and more efficient coverage of targeted vessel segments. Offered in 4F and 5F sizes and multiple lengths, Viper™ catheters are specifically intended for controlled and selective delivery of agents into the general vasculature—excluding coronary, pediatric, or neonatal applications.

Valved-Tip Construction
  • Flexible Infusion Options: The valve at the distal tip enables fluid infusion directly through the catheter lumen, even in the absence of a guidewire.
  • Improved Lumen Area: By avoiding a tip-occluding guidewire during treatment, the infusion pathway effectively doubles in diameter (compared to catheters requiring a wire in place), enhancing infusion capacity.
  • Large Infusion Lumen: Facilitates high-flow infusion of anti-thrombus agents or radiopaque contrast.
  • Enhanced Deliverability: Maintains a low-profile catheter body for streamlined advancement through tortuous vessels.
  • 4F & 5F Catheters: Address the needs of diverse peripheral vessel diameters—choose the size that best aligns with procedural goals.
  • Various Usable Lengths: Available in multiple lengths (consult device labeling) to accommodate short or extended lesion coverage and different access sites.
  • Adaptable: Suitable for physician-specified pharmacologic agents (e.g., thrombolytics, vasodilators) or routine contrast media.
  • Standard IFU Compliance: Pharmacologic agents should be prepared and administered per each drug’s instructions for use to ensure safe infusion.
  • Flexible Infusion Options: The valve at the distal tip enables fluid infusion directly through the catheter lumen, even in the absence of a guidewire.
  • Improved Lumen Area: By avoiding a tip-occluding guidewire during treatment, the infusion pathway effectively doubles in diameter (compared to catheters requiring a wire in place), enhancing infusion capacity.
  • Large Infusion Lumen: Facilitates high-flow infusion of anti-thrombus agents or radiopaque contrast.
  • Enhanced Deliverability: Maintains a low-profile catheter body for streamlined advancement through tortuous vessels.
  • 4F & 5F Catheters: Address the needs of diverse peripheral vessel diameters—choose the size that best aligns with procedural goals.
  • Various Usable Lengths: Available in multiple lengths (consult device labeling) to accommodate short or extended lesion coverage and different access sites.
  • Adaptable: Suitable for physician-specified pharmacologic agents (e.g., thrombolytics, vasodilators) or routine contrast media.
  • Standard IFU Compliance: Pharmacologic agents should be prepared and administered per each drug’s instructions for use to ensure safe infusion.
Product Specifications

Specification Detail / Value
Product Name Viper ULTRA Thrombolysis Catheter
Intended Use Catheter-directed infusion of thrombolytics in acute or subacute thrombus (peripheral, venous, or arterial)
Catheter Design Multi-hole distal segment for uniform drug dispersion, possible radiopaque marker at tip
Material Pebax/Polyamide shaft, potentially braided or reinforced
Outer Diameter (F) ~4–6F (depending on infusion lumen capacity)
Working Length ~80–150 cm (varies by product code)
Infusion Ports Distributed side ports over a defined segment for consistent thrombolytic delivery
Guidewire Compatibility Typically 0.014” or 0.018”
Sterility Sterile, Single Use
Shelf Life ~2–3 years if stored at 15–25 °C in sealed packaging
Clinical Indications Thrombolytic infusion for DVT, peripheral arterial occlusions, possibly for intra-graft thrombosis
Contraindications Highly calcified lesions, severe vessel tortuosity preventing safe passage, known device material allergies

 

Ordering & Size Matrix

Outer Diameter (F) Working Length (cm) Infusion Segment (cm) Product Code Notes
4F 80 10 VPR-4F-80-10 Smaller OD for distal or small vessel usage
4F 120 15 VPR-4F-120-15 Longer shaft, moderate infusion segment
5F 80 10 VPR-5F-80-10 Slightly larger OD for heavier clot load
5F 120 20 VPR-5F-120-20 Extended length with longer infusion zone
6F 100 15 VPR-6F-100-15 Common size for multi-level peripheral lesions
6F 150 30 VPR-6F-150-30 Max length, extensive infusion segment

Reviews

There are no reviews yet.

Be the first to review “Viper™ Valved Infusion Catheters”

Your email address will not be published. Required fields are marked *

Quick Comparison

Viper™ Valved Infusion Catheters removeAVI Bilipod LED Phototherapy Unit removeBistos BT- 410 Medical Head Lamp removeBistos BT-770-12.1" Touchscreen Patient Monitor removeSpinal Epidural Pack removeLED Surtron 200 HP Diathermy Machine remove
NameViper™ Valved Infusion Catheters removeAVI Bilipod LED Phototherapy Unit removeBistos BT- 410 Medical Head Lamp removeBistos BT-770-12.1" Touchscreen Patient Monitor removeSpinal Epidural Pack removeLED Surtron 200 HP Diathermy Machine remove
ImageAVI Phototherapy UnitBistos BT-410 Medical Head LampBistos BT-770-12.1" Touchscreen Patient MonitorLED Surtron 200 HP Diathermy Machine
SKUSF1033560094-4SF1033560059-6SF1033560059-1SF1033560084-25SF1033560034-3
Rating
Price

$0.00

$0.00

$0.00

$0.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad The Viper™ Valved Infusion Catheter is a single-lumenvalved-tip delivery system that offers the flexibility to infuse anti-thrombus agents, radiopaque contrast, or other physician-specified pharmacologic solutions with or without a guidewire in place.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad
Usage/Application Hospital
Color White
Material Plastic
Application Hospital
Model Bilipod
Brand AVI
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from abroad Bistos BT- 410 Medical Head Lamp - Head-worn light BT-410 provides not only comfortable wear but also convenient for use during examinations or operations. - Ultra bright LED light with High density LED - Easy to adjust head strap & an angle - Extensive LED lifetime (more than 50,000 hours) - More than 4 hours of continuous use - An additional astral LED lamp (optional) - Attachable loupe (optional) Delivery & Availability: Typically 7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped from Abroad The Bistos BT-770 patient monitor is equipped with a 12.1" touchscreen display, which allows for an easy operation and readability with a powerful rechargeable battery guaranteeing a continuous operation of 5 hours to monitor ECG, SpO2, NIBP, temperature and respiration Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In Stock It is for performing spinal/epidural or combined spinal/epidural or never-block loco-regional anaesthesia on patinet in clinical surgery.

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad SURTRON 200 is a high frequency electrosurgical equipment which is suitable for light and medium surgery and also allows to execute surgical minimally invasive  procedure of resection, evaporation and coagulation. Delivery & Availability: Typically 10 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content

The Viper™ Valved Infusion Catheter is a single-lumenvalved-tip delivery system that offers the flexibility to infuse anti-thrombus agents, radiopaque contrast, or other physician-specified pharmacologic solutions with or without a guidewire in place. By eliminating the need for a tip-occluding wire during treatment, Viper™ greatly expands the available infusion lumen, allowing higher flow rates and more efficient coverage of targeted vessel segments. Offered in 4F and 5F sizes and multiple lengths, Viper™ catheters are specifically intended for controlled and selective delivery of agents into the general vasculature—excluding coronary, pediatric, or neonatal applications.

Valved-Tip Construction
  • Flexible Infusion Options: The valve at the distal tip enables fluid infusion directly through the catheter lumen, even in the absence of a guidewire.
  • Improved Lumen Area: By avoiding a tip-occluding guidewire during treatment, the infusion pathway effectively doubles in diameter (compared to catheters requiring a wire in place), enhancing infusion capacity.
  • Large Infusion Lumen: Facilitates high-flow infusion of anti-thrombus agents or radiopaque contrast.
  • Enhanced Deliverability: Maintains a low-profile catheter body for streamlined advancement through tortuous vessels.
  • 4F & 5F Catheters: Address the needs of diverse peripheral vessel diameters—choose the size that best aligns with procedural goals.
  • Various Usable Lengths: Available in multiple lengths (consult device labeling) to accommodate short or extended lesion coverage and different access sites.
  • Adaptable: Suitable for physician-specified pharmacologic agents (e.g., thrombolytics, vasodilators) or routine contrast media.
  • Standard IFU Compliance: Pharmacologic agents should be prepared and administered per each drug’s instructions for use to ensure safe infusion.
  • Flexible Infusion Options: The valve at the distal tip enables fluid infusion directly through the catheter lumen, even in the absence of a guidewire.
  • Improved Lumen Area: By avoiding a tip-occluding guidewire during treatment, the infusion pathway effectively doubles in diameter (compared to catheters requiring a wire in place), enhancing infusion capacity.
  • Large Infusion Lumen: Facilitates high-flow infusion of anti-thrombus agents or radiopaque contrast.
  • Enhanced Deliverability: Maintains a low-profile catheter body for streamlined advancement through tortuous vessels.
  • 4F & 5F Catheters: Address the needs of diverse peripheral vessel diameters—choose the size that best aligns with procedural goals.
  • Various Usable Lengths: Available in multiple lengths (consult device labeling) to accommodate short or extended lesion coverage and different access sites.
  • Adaptable: Suitable for physician-specified pharmacologic agents (e.g., thrombolytics, vasodilators) or routine contrast media.
  • Standard IFU Compliance: Pharmacologic agents should be prepared and administered per each drug’s instructions for use to ensure safe infusion.
Product Specifications
Specification Detail / Value
Product Name Viper ULTRA Thrombolysis Catheter
Intended Use Catheter-directed infusion of thrombolytics in acute or subacute thrombus (peripheral, venous, or arterial)
Catheter Design Multi-hole distal segment for uniform drug dispersion, possible radiopaque marker at tip
Material Pebax/Polyamide shaft, potentially braided or reinforced
Outer Diameter (F) ~4–6F (depending on infusion lumen capacity)
Working Length ~80–150 cm (varies by product code)
Infusion Ports Distributed side ports over a defined segment for consistent thrombolytic delivery
Guidewire Compatibility Typically 0.014” or 0.018”
Sterility Sterile, Single Use
Shelf Life ~2–3 years if stored at 15–25 °C in sealed packaging
Clinical Indications Thrombolytic infusion for DVT, peripheral arterial occlusions, possibly for intra-graft thrombosis
Contraindications Highly calcified lesions, severe vessel tortuosity preventing safe passage, known device material allergies
 
Ordering & Size Matrix
Outer Diameter (F) Working Length (cm) Infusion Segment (cm) Product Code Notes
4F 80 10 VPR-4F-80-10 Smaller OD for distal or small vessel usage
4F 120 15 VPR-4F-120-15 Longer shaft, moderate infusion segment
5F 80 10 VPR-5F-80-10 Slightly larger OD for heavier clot load
5F 120 20 VPR-5F-120-20 Extended length with longer infusion zone
6F 100 15 VPR-6F-100-15 Common size for multi-level peripheral lesions
6F 150 30 VPR-6F-150-30 Max length, extensive infusion segment
Features:
  • BILIPOD LED Double Surface Phototherapy Unit Sturdy Baby Trolley consists of –  Collapsible Acrylic Side Panels  Transparent Baby Tray with Bubble Mattress  Height Adjustment and Angle Adjustment for Overhead LED Module  Four Swivelling castor wheels with brakes Certified Also available - Bilipod Double Surface Phototherapy Unit with Detachable trolley
  • Uniform Light Distribution with 11 High Intensity LED Lamps uniform body coverage • Observation Lamp Two Observation White LEDs provide enough light to observe the color of baby’s skin • High Irradiance Levels Irradiance > 30 µW/cm²/nm enables faster bilirubin breakdown • Pin Drop Silent Operation zero noise cooling fan • Optimum Wavelength Range: 420 to 490 nm • Very Low Power Consumption of only 30W • Effective Surface Area : 40cm x 50cm
  • Life of Lamps - 30000 hours • Lamp Tilt up to 90° • Height Adjustability up to 50cm • Light Weight Lamp Unit weighs less than 3 Kg • Portable can be placed above Infant incubator or below the Infant Warmer Bassinet to give under surface Phototherapy • Sleek & Compact Lamp Unit Size : 45 x 30 x 5 cm takes minimum space • Timer: LCD Based Timer measuring Total Lamp Usage and Patient Timer
  • BiliProbe Irradiance Meter Handheld Irradiance (Flux) meter for measurement of the output of conventional Phototherapy Units.  Bandpass filter - 425nm to 475nm  Range: 0 to 200 uW/cm²/nm  Minimal Graduation: 1 uW/cm²/nm  Accuracy: ± 10%  Measuring Time: Approx 4-5 sec  Press to ON Switch  Battery: 9V Alkaline Phototherapy Eye PATCH has been designed to assure complete comfort, and eye protection for infants during Phototherapy Treatment  Adjustable Band for proper comfort and secure fit  Easy to use design  Large eye protection pad increases light protection  Single Piece wrap around design can be independently adjusted to prevent unwanted movement.  Available in 3 sizes - Preterm, Term and Neonatal Phototherapy Eye Patch
Specifications:
Usage/Application Hospital
Color White
Material Plastic
Application Hospital
Model Bilipod
Brand AVI
 
Click Here To Download Catalogue 
Bistos BT- 410 Medical Head Lamp - Head-worn light BT-410 provides not only comfortable wear but also convenient for use during examinations or operations. - Ultra bright LED light with High density LED - Easy to adjust head strap & an angle - Extensive LED lifetime (more than 50,000 hours) - More than 4 hours of continuous use - An additional astral LED lamp (optional) - Attachable loupe (optional). Features: Illumination Uniformity:
  • Multi-lens structure ensures high level of uniform luminance in its light spot.
Coaxial Design:
  • Light source is located between two eyes is able to cast least shadow on the surface.
  • Also, the luminance angle moves freely with pivot joint structure.
Interchangeable Battery:
  • Rechargeable battery is interchangeable. With additional battery, no need to worry anymore about remaining power.
Technical Specifications: Model - (BT - 410) Order code - 410F Illumination - (Standard - 15,000 - 30,000 lx) Adjustable Illumination - Yes Illumination Uniformity - High Adjustable Light Spot - No Light Spot Size (at 300mm) - 70mm Astral Lamp - No Color Temperature - 6,000 K LED Life Time - Appox. 50,000 hour Loupe: Type - Single Lens Magnification - 2 x Battery: Type - Lithum-ion Capacity - 3.7V / 2,200 mAh Run time - 4 hour Charging time - 4 hour Weight - 190 g Band Size - (540 - 640mm) Warranty - 1 year  
Click Here To Download Catalogue 
Bistos BT-770 is a 12.1" touchscreen patient monitor designed for easy operations. SPECIFICATIONS
  • 12.1“ color TFT touch screen
  • ECG, Resp., SpO2, NIBP, Temp., CO2, IBP, Multi-gas, C.O., Masimo SpO2
  • Precise ECG measurement with pacemaker detection ST segment and 16 types of arrhythmia analysis Double overpressure protection for NIBP Intelligent cuff inflation pressure adjustment
  • Smart Hook/Stand design, provide multiple placement modes Plug & Play Modular IBP& C.O., Modular Printer Multiple configuration options: 4-channel IBP, CO2, invasive C.O., Multi-gas Over 5 hours continuous working on battery 12-15V wide range DC input, suitable for ambulance Capable to connect with central monitoring system HL7 export to clinical information systems (option)
 
Click Here To Download Catalogue
It is for performing spinal/epidural or combined spinal/epidural or never-block loco-regional anaesthesia on patinet in clinical surgery. Component:
  • Epidural needle 16G,
  • Epidural catheter,
  • Epidural filter 0.2 um,
  • Catheter connector,
  • LOR syringe
SURTRON 200 is a high frequency electrosurgical equipment which is suitable to light and medium surgery. SURTRON 200 allows to execute surgical minimally invasive  procedure of resection, evaporation and coagulation. Through its performances, SURTRON 200, allows pure CUT,  cut-coagulation BLEND, incision with reduced prodution of eschar ENHANCED, superficial coagulation FORCED COAG, deep coagulation in absence of necrosis SOFT COAG and BIPOLAR coagulation. The digital reading of the delivered power and the overseeing through microcontroller of the operational functions, assure the absolute reliability of the conditions of job. SURTRON 200 allows a highly professional surgery thanks to the user-friendly and safety solutions normally used. The connection of neutral electrode is constantly monitored. Safety control of patient/plate contact using split neutral electrode. The possibility to control by the handle the output functions as well as the delivery of output power, allows to implement the surgical operation without turning away the surgeon attention from the surgical field. FEATURES Code 10100.401 Max output power CUT: 200W – 250Ω Max output power ENHANCED: 120W – 250Ω Max output power BLEND: 120W – 200Ω Max output power FORCED COAG: 150W – 150Ω Max output power SOFT COAG: 90W – 100Ω Max output power BIPOLAR COAG: 80W – 50Ω Working frequency: 600 kHz Patient circuit: F Mains voltage: 115-230 Vac Mains frequency: 50-60 Hz Electrical input power: 350 VA Size WxHxD: 370x144x319 mm Weight: 6 Kgs CONTROLS Patient/Plate circuit monitoring Output power monitoring Self check control SAFETY EN60601-1 EN60601-1-2 EN60601-2-2 Electrical classification: CF MDD 93/42 / EC: II b  
Click Here To Download Catalogue
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare