Multigas Monitor AneSure-H
$0.00
Shipped From Abroad
AneSure-H is a safe and reliable anesthesia gas monitor, which can guide anesthesiologists to use anesthesia gas to ensure the safety of patients during anesthesia.
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
Features of AneSure Handheld Anesthesia Multigas Monitor AneSure-H
- Specially-designed Water filter
Water filters can be used for working under a heavy humid environment, also suitable for intubated or non-intubated patients.
Economic
An Economic Multi-gas monitor that supports safe agent administration.
- Automatic atmospheric pressure compensation
Automatically adjust atmospheric pressure compensation according to altitude conditions
- Reliable and Accurate
Based on Kingst’s mature technology of infrared gas analysis.
- Alarm For Data Overrun And Suffocation
Quick warm-up with the first value displayed in 5 seconds, and accurate readings displayed in 15 seconds. 24-hour trend graphs, not lost when power off

Specifications of AneSure Handheld Multigas Monitor AneSure-H
| AC Input | 100V – 240V, 50Hz/60 Hz to 5VDC Adapter with 5V mini USB adapter Cable. Optional Vehicle 12V to 5V Mini USB Charger Lead. |
| Battery | Built-in rechargeable lithium battery pack,(3.7V, 3500mAH) |
| Temperature | 5 to +50℃ |
| Humidity | < 93% (non-condensing) = < 29.45 hPa |
| Atmospheric pressure | 70 – 120 kPa |
| Technique | NDIR (Non-dispersive infrared gas analysis) |
| Sampling Mode | Sidestream |
| EtCO2, FiCO2 measurement | Range: 0 – 150mmHg or 0 – 20kPa or 0 – 19.7% (v/v)
Accuracy: ±2mmHg for CO2 range 0 – 40mmHg ±5% for CO2 range from 41 – 70mmHg ±8% for CO2 range from 71 – 100mmHg ±10% Over 100mmHg |
| Update/Averaging Time | Option of every breath or 10, 20, or 30 seconds |
| Sample Flow Rate | 50–250ml/min User Adjustable. Default=100ml/min <±20% for sample flow rate ranges from 50–250ml/min |
| FiN2O/EtN2O measurement | Range: 0-100%
Accuracy: ± (2 vol% + 2% of reading) |
| FiHAL/EtHAL, FiENF/EtENF, FiISO/EtISO measurement | Range: 0-12%
Accuracy: 0-8%: ± (0.15 vol% + 5% of reading); 8-12%: unspecified |
| FiSEV/EtSEV measurement | Range: 0-15%
Accuracy: 0-10%: ± (0.15 vol% + 5% of reading); 10-15%: unspecified |
| FiDES/EtDES measurement | Range: 0-25%
Accuracy: 0-18%: ± (0.15 vol% + 5% of reading); 18-25%: unspecified |
| All FiAG | Update: every 2-3 breath
Trends: 24 hours on Screen Trend and Numeric |
| Atmospheric Pressure Compensation | Auto-compensation for atmospheric pressure variation |
| Respiration Rate | Range: 3 – 150 breaths/minute
Accuracy: ±1% of reading or ±1 breaths/min whichever is greater |
| SpO2 (optional) | Range: 0 – 100%
Accuracy: ±2% for SpO2 range from 70 – 100%, 70% of the following does not require |
| Pulse Rate (optional) | Range: 30 – 250bpm
Accuracy: 30 Beats/min~40 Beats/min, error±2 Beats/min; 41 Beats/min~250 Beats/min, error±2 Beats/min (Absolute value) or a maximum of ± 2% (Relative value) |
| Rise time | CO2 is less than 200ms;
N2O is less than 300ms; Anesthetic gases (halothane, enflurane, isoflurane, sevoflurane, or desflurane) are less than 300ms |
| Warm Up Time | <15 seconds |
| Agent threshold | 0.2%, When an agent is identified, concentrations will be reported even below 0.2% as long as apnea is not detected |
| Alarm limits | Apnea alarm limits:15-40 sec
High alarm limits EtCO2/ FiCO2:22-150mmHg Low alarm limits EtCO2/ FiCO2: 00-60mmHg High alarm limits FiHAL/EtHAL, FiENF/EtENF, FiISO/EtISO:1.0-8.0% Low alarm limits FiHAL/EtHAL, FiENF/EtENF, FiISO/EtISO:0-6.5% High alarm limits FiSEV/EtSEV:1.0-10.0% Low alarm limits FiSEV/EtSEV:0-6.5% High alarm limits FiDES/EtDES:1.0-18.0% Low alarm limits FiDES/EtDES: 0-6.5% High alarm limits FiN2O/EtN2O:26-100% Low alarm limits FiN2O/EtN2O: 01-78% The high alarm limits of respiration rate:4-150 breaths/min The low alarm limits of respiration rate:0-140 breaths/min The high alarm limits of SpO2:off The low alarm limits of SpO2:50-100% The high alarm limits of Pulse Rate:70-250 bpm The low alarm limits of Pulse Rate:30-100 bpm |
| Size | 70 x 160 x 40mm (W x H x D) |
| Weight | Monitor 380g, Weight on Airway ETT/LMA<25g |
| Warranty & Maintenance/ Calibration | One-year warranty on main unit and lithium-ion rechargeable battery Auto self-zeroing calibration, annual calibration check recommended |
Application Scenarios of AneSure Handheld Multigas Monitor AneSure-H
- AneSure-H is a portable accurate anesthesia multi-gas monitor.
- Equipped with a specially designed water filter, AneSure-H can work continuously for a long time in a high-humidity environment, and is suitable for both intubated and non-intubated patients;
- AneSure-H is a safe and reliable anesthesia gas monitor, that can guide anesthesiologists to use anesthesia gas to ensure the safety of patients during anesthesia;
- And there is an internal barometer for automatic pressure compensation.
- It has an alarm function, which will alarm when the measured value reaches the alarm limits or when suffocation occurs;
- The first data can be obtained within 5 seconds after power-on, and full accurate data can be obtained within 15 seconds; the 24-hour graphs will not be lost when power off;
Quick Comparison
| Multigas Monitor AneSure-H remove | CWS 5000- Patient Warming Machine remove | Render SD-M2000C+ Anesthetic Machine remove | Dolphin-IQ Transcranial Doppler Probe remove | Render SD-M2000B Anesthetic Machine remove | PG-907s-Infusion Pump remove | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Name | Multigas Monitor AneSure-H remove | CWS 5000- Patient Warming Machine remove | Render SD-M2000C+ Anesthetic Machine remove | Dolphin-IQ Transcranial Doppler Probe remove | Render SD-M2000B Anesthetic Machine remove | PG-907s-Infusion Pump remove | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| SKU | SF1033560130170-13 | SF103356013087-1 | SF1033560011-11 | SF1033560130142-3 | SF1033560011-10 | SF10335601298-3 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Rating | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Price |
|
|
|
|
|
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Stock | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Availability | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Add to cart | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Description | Shipped From Abroad
AneSure-H is a safe and reliable anesthesia gas monitor, which can guide anesthesiologists to use anesthesia gas to ensure the safety of patients during anesthesia.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped from Abroad
| Shipped From Abroad
All of the advantages and performance of the cutting-edge Dolphin TCD technology for measurements of cerebral blood flow velocities are implemented in the smart and compact Dolphin/IQ Transcranial Doppler module.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped from Abroad
| Shipped From Abroad
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Content | Features of AneSure Handheld Anesthesia Multigas Monitor AneSure-H
Water filters can be used for working under a heavy humid environment, also suitable for intubated or non-intubated patients.
Economic
An Economic Multi-gas monitor that supports safe agent administration.
Automatically adjust atmospheric pressure compensation according to altitude conditions
Based on Kingst's mature technology of infrared gas analysis.
Quick warm-up with the first value displayed in 5 seconds, and accurate readings displayed in 15 seconds. 24-hour trend graphs, not lost when power off
![]() Specifications of AneSure Handheld Multigas Monitor AneSure-H
Application Scenarios of AneSure Handheld Multigas Monitor AneSure-H
| Two speed fan motor and two levels of flow rates. CWS 5000 can inflate a very large blanket as well as a small blanket. • Uses a DC motor, quieter and state of the art blower. • CWS 5000 is controlled and operated through a unique robust software developed by Care Essentials. • The Cocoon™ CWS 5000 is light and compact, yet very sturdy. • Designed to be user friendly. • We comply with all essential regulatory standards. We have FDA, CE, TGA, Japan Health approvals. CWS 5000 has been tested for IEC 60601-1 3rd Edition, AM 1 by UL, USA. |
Click Here To Download Catalogue | https://youtu.be/Id0Ma1_lEo0?si=kRJ1bUMjUCBuCAqR
Features of Dolphin TCD Machine |
Click Here To Download Catalogue | Features
Click here to download Data Sheet | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Weight | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Dimensions | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Additional information |






Reviews
There are no reviews yet.