Neuro-IOM-32/S is a sophisticated intraoperative monitoring (IOM) system designed for real-time neurological assessment during surgeries. It offers 32 channels for EMG, EEG, and Evoked Potentials (EP), ensuring continuous monitoring of neural functions. This system helps in identifying potential neurological risks during complex surgeries, allowing surgeons and neurophysiologists to make informed decisions and prevent neural damage. With high-resolution diagnostics and a user-friendly interface, the Neuro-IOM-32/S enhances patient safety and optimizes surgical outcomes.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130187-22
Brands:: Neurosoft

Description

32-channel System with Basic Functions for Intraoperative Neurophysiological Monitoring

 

 

32 bipolar channel system, entry level

This configuration of Neuro-IOM system (version 2) includes all basic functions to perform intraoperative neurophysiological monitoring

Main features:

  • 64 amplifier inputs (32 bipolar channels)
  • 32-channel amplifier significantly improves the quality of IONM as more conduction pathways are monitored in comparison with 16-channel amplifier.
  • 2 dedicated channels for routine EMG, NCS and EP;
  • 4 electrical stimulator channels;
  • direct nerve stimulation channel;
  • auditory, visual and pattern stimulator channels;
  • ES detector channels.

The Neuro-IOM system allows performing intraoperative neurophysiological monitoring of all modalities, including MEP acquisition using the electrical stimulator with current intensity of up to 200 mA.

The Neuro-IOM system is equipped with the acquisition and stimulator pods to attach recording and stimulating electrodes with 5 m cables. It allows arranging the system at a distance from the operating table to ensure free movement for the surgical team. The set of specially-designed electrodes and the software are also included to the delivery set.

Motor, somatosensory, auditory and visual evoked potentials, EMG, direct nerve stimulation, EEG, ECoG — more than 10 modalities for intraoperative neurophysiological monitoring

The Neuro-IOM system is delivered with the preset templates ensuring the following modalities:

  • direct nerve stimulation;
  • free-run EMG;
  • somatosensory evoked potentials (SEP);
  • motor evoked potentials (MEP);
  • auditory evoked potentials (AEP);
  • visual evoked potentials (VEP);
  • EEG;
  • ECoG;
  • direct cortical stimulation;
  • train-of-four stimulation (TOF).

Using these modalities the surgical team can control motor and sensory pathways, monitor peripheral nerve integrity, assess the brain activity and perform mapping of its functional areas, etc.

Flexible configurations to ensure any monitoring needs

The Neuro-IOM.NET software provides a set of default templates for various types of surgeries. Each template includes the settings of modalities for a particular type of surgery, test window layouts, acquisition and stimulation parameters, etc. The system has a vast number of channels and stimulators with separate adjustment. Use of preset templates simplifies and speeds up the system setup for surgery.

You can always change and save the settings of any surgery template. It is a unique option for such kind of systems. There is no IONM system in the world that is so flexible!

Applications
  • SEP acquisition
  • MEP acquisition
  • 64 amplifier inputs( 32 bipolar channels)
  • auditory and visual evoked potentials, EMG, direct nerve stimulation, EEG, ECoG — more than 10 monitoring modalities
  • flexible configurations to ensure any monitoring needs

 

Download Brochure

Reviews

There are no reviews yet.

Be the first to review “Neuro-IOM-32/S”

Your email address will not be published. Required fields are marked *

Quick Comparison

Neuro-IOM-32/S removeFalcon-ABI+ Transcranial Doppler Probe removeND-8S EEG Monitor removeEctron Ectonustim Series 6 Electroconvulsive Therapy ECT Machine removeBRAINSWAY Deep TMS 104 RCT System removeBRAINSWAY Deep TMS H7 Coil remove
NameNeuro-IOM-32/S removeFalcon-ABI+ Transcranial Doppler Probe removeND-8S EEG Monitor removeEctron Ectonustim Series 6 Electroconvulsive Therapy ECT Machine removeBRAINSWAY Deep TMS 104 RCT System removeBRAINSWAY Deep TMS H7 Coil remove
Image
SKUSF1033560130187-22SF1033560130142-7SF10335601235SF1033560130162-3SF1033560130162-5
Rating
Price

$0.00

$0.00

$0.00

$0.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad Neuro-IOM-32/S is a sophisticated intraoperative monitoring (IOM) system designed for real-time neurological assessment during surgeries. It offers 32 channels for EMG, EEG, and Evoked Potentials (EP), ensuring continuous monitoring of neural functions. This system helps in identifying potential neurological risks during complex surgeries, allowing surgeons and neurophysiologists to make informed decisions and prevent neural damage. With high-resolution diagnostics and a user-friendly interface, the Neuro-IOM-32/S enhances patient safety and optimizes surgical outcomes.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad

Early diagnosis and early treatment, are dedicated to the "stationary" solutions for brain function diagnosis and treatment.

Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad

This machines have been developed from the well-proven Series 5A and 5B ECT apparatus. The series 6+ models incorporate all the features of the corresponding Series 5B versions. Experience has shown that a very few patients sometimes require higher dosage than was available with the earlier machines and the opportunity was therefore taken to produce equipment with a second, higher, output range.

Delivery & Availability: Typically 3 Months – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad BrainsWay's 104 RCT System enables blinded clinical research via a card reader that randomizes selection of sham or Deep TMS stimulation. The sham coil is integrated into the helmet with the treatment coil, producing similar sounds and sensations.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad The H7 Coil stimulates the anterior cingulate cortex and the medial prefrontal cortex. Complementing a large-scale, double-blind, multicenter randomized controlled trial, which demonstrated strong response rates, greater than 1 in 2 OCD patients who completed 29 sessions in real clinical practice achieved sustained response.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
32-channel System with Basic Functions for Intraoperative Neurophysiological Monitoring
  https://youtu.be/XyI13InME9A?list=PLU2BvNtfeStPOl_izQJDwlLEi6eLCrDEF   32 bipolar channel system, entry level This configuration of Neuro-IOM system (version 2) includes all basic functions to perform intraoperative neurophysiological monitoring Main features:
  • 64 amplifier inputs (32 bipolar channels)
  • 32-channel amplifier significantly improves the quality of IONM as more conduction pathways are monitored in comparison with 16-channel amplifier.
  • 2 dedicated channels for routine EMG, NCS and EP;
  • 4 electrical stimulator channels;
  • direct nerve stimulation channel;
  • auditory, visual and pattern stimulator channels;
  • ES detector channels.
The Neuro-IOM system allows performing intraoperative neurophysiological monitoring of all modalities, including MEP acquisition using the electrical stimulator with current intensity of up to 200 mA. The Neuro-IOM system is equipped with the acquisition and stimulator pods to attach recording and stimulating electrodes with 5 m cables. It allows arranging the system at a distance from the operating table to ensure free movement for the surgical team. The set of specially-designed electrodes and the software are also included to the delivery set. Motor, somatosensory, auditory and visual evoked potentials, EMG, direct nerve stimulation, EEG, ECoG — more than 10 modalities for intraoperative neurophysiological monitoring The Neuro-IOM system is delivered with the preset templates ensuring the following modalities:
  • direct nerve stimulation;
  • free-run EMG;
  • somatosensory evoked potentials (SEP);
  • motor evoked potentials (MEP);
  • auditory evoked potentials (AEP);
  • visual evoked potentials (VEP);
  • EEG;
  • ECoG;
  • direct cortical stimulation;
  • train-of-four stimulation (TOF).
Using these modalities the surgical team can control motor and sensory pathways, monitor peripheral nerve integrity, assess the brain activity and perform mapping of its functional areas, etc. Flexible configurations to ensure any monitoring needs The Neuro-IOM.NET software provides a set of default templates for various types of surgeries. Each template includes the settings of modalities for a particular type of surgery, test window layouts, acquisition and stimulation parameters, etc. The system has a vast number of channels and stimulators with separate adjustment. Use of preset templates simplifies and speeds up the system setup for surgery. You can always change and save the settings of any surgery template. It is a unique option for such kind of systems. There is no IONM system in the world that is so flexible!
Applications
  • SEP acquisition
  • MEP acquisition
  • 64 amplifier inputs( 32 bipolar channels)
  • auditory and visual evoked potentials, EMG, direct nerve stimulation, EEG, ECoG — more than 10 monitoring modalities
  • flexible configurations to ensure any monitoring needs
  Download Brochure
https://youtu.be/YSWvhSIS1ho?si=3W6Cb6LTqWccEtiz
Features of Falcon Physiologic Machine

Segmental Blood Pressures

Measure lower extremity pressures easily with 10 color-coded channels and a variety of Doppler probes and PPG sensors. Complete the vascular diagnosis with supportive stress testing. Falcon is considered by many the best segmental pressure machine with numerous advanced features such as 10 simultaneous PVR measurements and limitless post-processing capabilities.

Fast and Accurate ABI & TBI

Quickly measure ABI and TBI with either Doppler or Photoplethysmography (PPG). With the Falcon ABI and TBI machine, all measurements are saved automatically and sent directly to the dedicated interactive summary screen.  

High Quality Doppler Probes

In addition, to the 4 MHz and 8 MHz probes for standard use, the advanced Falcon/Quad and Falcon/Pro Doppler machines offer a unique 10 MHz probe, which is designed to measure particularly small peripheral blood vessels. All Falcon Doppler probes produce complete high-resolution Doppler spectral analysis with the aid of the Falcon vascular software and algorithms.

State-of-the-Art PPG Sensors

Falcon offers a wide selection of Photoplethysmography sensors.   The 5 completely independent PPG ports allow simultaneous fingers/toes measurements, which is especially useful for Raynaud’s diagnosis along with a an integrated temperature sensor.  Fingerclip and Toeclip PPG sensors are recommended for routine examinations. The Disc PPG sensors are particularly useful for Venous Reflux testing and are supplied with dedicated adhesive stickers.  

Highest Durability and Reliability

The Falcon is the most reliable peripheral vascular machine in the market.  Thanks to the high quality Doppler probes, 10 Independent Pressure Channels (IPU Technology) and 5 PPG Ports, the Falcon design significantly reduces any down-time.  Falcon is in distributed worldwide for over 10 years with the lowest fail rate in the market!

Complete Network Connectivity

The Falcon unmatched connectivity capabilities are a paradise to hospital IT personnel and EMR and PACS managers. The advanced networking abilities allow a plug-and-play operation to easily configure connectivity with automated DICOM Worklist & Storage, Structured Report, and HL7. With unlimited Review Stations, measurements can be reanalyzed and interpreted from the comfort of your office. Final reporting can also be configured and finalized from any location.

Simplify Your Workflow

The Falcon vascular diagnosis device has the ability to configure as many dedicated examination protocols that allow to save time and optimize the patient vascular diagnosis​. Enjoy the user-friendly protocol builder to configure your workflow according to your needs!​

Ease of Use

Minimal learning curve thanks to user-friendly software with a large touch-screen display. A selection of wired and wireless remote control​ and footswitch allows keeping your focus on the patient rather than on the physiologic vascular equipment.

Dedicated Specialty Tests

The Falcon is the complete vascular physiologic assessment machine with dedicated protocols that guide you through step-by-step diagnostic measurements of specific vascular conditions.  The dedicated diagnosis protocols include measurements of Thoracic Outlet Syndrome (TOS), diagnosis of Raynaud’s Phenomenon, evaluation of Penile Function or Erectile Dysfunction, assessment of Allen’s Test (or Palmar Arch Test), measurements of Venous Reflux and Venous Capacitance and Outflow, Pulse Wave Velocity, and more.

Advanced Reporting

The famous Falcon user-friendly report builder tool allows you to design your own report layout easily. Then, add your institute/clinic logo and details to create a detailed and impressive diagnosis report that meets your institute standards. Save a lot of time by building your report with preconfigured interpretation templates.

Advanced Research Options

The Falcon vascular research machine is famous for its built-in statistics tool with on-screen graphs, segments filtering, and Excel tool, which are all designed to simplify the work of vascular and physiological researchers. Export to PDF, Excel, Word, JPEG, VSX, Video clips, and more to support your vascular research and teaching needs, as well as support your clinical vascular publications.
Features
HIE multi-dimensional identification and application 1) According to the amplitude and continuity of the upper/lower boundary of aEEG, the neonatal EEG activity will be classified, and the Hellstrom-Westas background five-classification method will be used to improve the ability of medical staff to identify the aEEG waveforms; 2) Masimo Rainbow SET pulse oximetry monitoring, monitor the SpO2/PI/PR change in a non-invasive and continuous manner, effectively eliminate the exercise interference, and improve the measurement performance under low perfusion and body motion.
  • Rechargeable battery Equipped with a rechargeable lithium-ion battery to support 2h independent working time, which is convenient for transfer of patient.
  • Real-time detection of electrode impedance Provide the function of real-time detection of electrode impedance to ensure the validity of the detection information.
  • Stable integrated medical trolley Compliant with the allowable load in IEC60601-1, more stable than ordinary trolleys, easy to move, and special for bedside monitoring.
     
  • Epilepsy rapid identification and application 1) Envelope trend chart (ENVELOPE) is used to represent the change in the EEG amplitude, which can better eliminate the artifacts caused by interference and identify epileptic seizure events more accurately; 2) TP (total power), also known as total energy, reflects the change in the EEG amplitude and has high sensitivity and low specificity for clinically detecting epileptic seizures.
 
  • Medical all-in-one machine - "intuitive display in the multi-trend chart" 1) Complies with the EU CE-related: EN60601-1-2: 2015 and EN60601-1: 2006 standards, with better hardware security, stability, durability, and anti-interference; 2) Equipped with a 19-inch color touch medical-grade display screen, displays each trend chart and corresponding values clearly and intuitively; 3) Provides a variety of trend chart displays and real-time EEG displays to help clinicians interpret data in time and ensure the accuracy of clinical diagnosis.
 
  • Signal amplifier - "multi-channel signal acquisition" 1) Standard 4 channels and optional 8/12 channels, with impedance selection button, built-in SpO2 input channel, less interference from the environment, and more stable signal acquisition; 2) With strong anti-interference performance, it can also record high-quality electrophysiological signals in the complex NICU and operating room environments and during the transfer process.
 
  • High-definition night-vision video monitoring 1) The optional high-definition camera with night vision function supports horizontal and vertical rotation, and the illumination distance can be up to 20m; 2) The physical movement of patients can be monitored in a real-time manner through the LCD screen, eliminate artifacts caused by various interference, and detects EEG signals accurately.
This machines have been developed from the well-proven Series 5A and 5B ECT apparatus. The series 6+ models incorporate all the features of the corresponding Series 5B versions. Experience has shown that a very few patients sometimes require higher dosage than was available with the earlier machines and the opportunity was therefore taken to produce equipment with a second, higher, output range. Features: Constant Current stimulus Delivered Dosage Displayed Patient Dynamic Impedance Indicator Simple Single Dose Control Technical Specification: Input Supply: AC 100-120, 210-240 V 40/60 Hz Load: 70 W Apparatus Size: 305 x 170 x 105mm (12” x 6.5” x 4”) Weight: 3.24kg Low Range: 50-700mC @ 750mA High Range: 200-100mC @ 900mA Contents: Two-hand headpiece: 1 C.S lead: 1 Disposable electrodes: 50 Mains cable: 1 Operating & service manual: 1 Removable stand: 1  
Click Here To Download Catalogue
The BrainsWay Deep TMS 104 RCT System is a non-invasive treatment for mental health conditions that uses magnetic pulses to stimulate the brain.
  • ComponentsIncludes a stimulator, touchscreen interface, cooling system, and card reader 
  • TreatmentPatients wear a helmet with electromagnetic coils that deliver magnetic pulses to the brain 
  • PurposeTreats conditions like major depressive disorder (MDD), obsessive-compulsive disorder (OCD), and smoking cessation 
  • SafetyWell-tolerated treatment with a favorable safety profile 
  • EffectivenessResearch shows that Deep TMS is effective in alleviating symptoms 
  • InsuranceMany insurance providers offer coverage for Deep TMS 
  • Ease of useDesigned to be easy to use for operators and comfortable for patients 
  • Sham-enabledVersions are available for randomized controlled clinical research 
 
Features
The BrainsWay Deep TMS 104 RCT System has several features, including:
  • H-CoilsThe system's patented H-Coils are flexible and embedded in a cushioned, cooled helmet that fits each patient's head. The H-Coils provide deeper and broader stimulation than traditional TMS coils, which are rigid and shaped like a figure-8. 
  • Touchscreen interfaceThe system has an intuitive touchscreen interface. 
  • Cooling systemThe system has an efficient cooling system. 
  • Card readerThe system has a card reader that randomly selects sham or Deep TMS stimulation. 
  • Sham-enabled versionsSham-enabled versions are available for randomized controlled clinical research.
 

Click here to download Brochure 

The BrainsWay Deep TMS H7 Coil is a flexible coil used in transcranial magnetic stimulation (TMS) to stimulate the brain's medial prefrontal cortex and anterior cingulate cortex:
The H7 Coil stimulates the anterior cingulate cortex and the medial prefrontal cortex. Treatment is designed to regulate the CSTC circuit believed to be involved in the inhibition of impulsive behavior. A sham coil is integrated above the treatment coil.
  • What it does
    The H7 Coil is FDA-cleared to treat obsessive-compulsive disorder (OCD). It can also be used to treat other neuropsychiatric disorders, such as addiction, major depressive disorder, and autism spectrum disorder. 
  • How it works
    TMS uses magnetic pulses to induce an electrical current in the brain's neuronal tissue. The H7 Coil is integrated into a cooled, cushioned helmet that allows the patient to move around during treatment. 
  • How it's used
    The H7 Coil is designed to reach deeper and broader regions of the brain than previous TMS coils. The treatment is non-invasive and well-tolerated, with no adverse or long-lasting side effects. 
  • How it's delivered
    The treatment involves multiple sessions, each lasting about 18 minutes.
    Click here to download Brochure
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare