Neuron Spectrum-6G

$0.00

Shipped From Abroad

The Neuron-Spectrum-6G by Neurosoft is an advanced EEG system developed from 30 years of engineering experience and cutting-edge technologies. It offers superior input noise levels, frequency and amplitude ranges, and sampling frequencies, outperforming many clinical EEG machines. Designed for seamless integration with transcranial magnetic stimulation (TMS), it effectively records EEG and evoked potentials during TMS sessions without signal disruptions.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130187-8
Brands:: Neurosoft

Description

 

Features

Innovative EEG recorder with outstanding technical specifications

A new-generation EEG system, Neuron Spectrum-6G represents the 30-year experience of Neurosoft engineers and advanced technologies applied in the development of circuit solutions in medicine. The system outperforms most clinical EEG machines available today regarding such characteristics as input noise level, input frequency and amplitude range, and sampling frequency. Thanks to that and to the particularly developed software, it is possible to successfully use the system for TMS-EEG studies. The previous-generation EEG recorders usually went off-scale at the high-amplitude magnetic pulse and did not record an electroencephalogram. When designing this system, this disadvantage was fixed so that now the system allows recording of EEG and evoked potentials (EP) throughout a transcranial magnetic stimulation (TMS) session.

Non-interfering monophasic magnetic stimulator

For TMS-EEG sessions, we suggest using one of Neurosoft latest developments in magnetic stimulation. The monophasic stimulator ensures generation of high-amplitude pulses with high enough frequency. At the same time, its circuit is designed so that charging the capacitor does not cause additional interference in the EEG – the so-called “silent mode”. A variety of coils to choose from allow you to solve a wide range of clinical tasks.

Electrode system

An important success factor of the TMS-EEG technique is the appropriate electrode system. This solution offers a special electrode cap with the pre-defined electrode positions according to the 10-20 system for 21 or 32 EEG channels. The flat design of the electrodes allows positioning the coil as close to the head as possible, while the minimum metal content of the electrode allows minimizing artifact from the magnetic pulse on the EEG.

Software for recording, averaging, and analysis

 The Neuron-Spectrum.NET software implements the averaging of EPs induced by magnetic stimulation directly during recording. Automatic artifact removal from averaging allows obtaining pure responses for a minimum number of averagings. The latencies and amplitudes of EP components are calculated automatically and presented as tables and topographic maps. After the recording is completed, it is possible to change the filter parameters, perform averaging with different settings, for example, to remove pulse artifact from the averaged curves. The duration of a pulse artifact depends on the used electrodes, pulse intensity, and filter parameters. On average, artifact duration is 25 ms after pulse delivery, and immediately after that the system records pure EEG signal without interference.

Wide application possibilities

A few years ago when it became technically possible to record EEG during magnetic stimulation, TMS-EEG technique was only used in scientific research. Numerous works have now been published demonstrating the possibilities of this method in the treatment and diagnosis of various diseases. For example, TMS-EEG is widely used for evaluation of rehabilitation progress in stroke patients and helps in localization of the epileptic focus. The studies performed today using this technique allow suggesting that the scope of its application will expand even further in the future.

Reviews

There are no reviews yet.

Be the first to review “Neuron Spectrum-6G”

Your email address will not be published. Required fields are marked *

Quick Comparison

Neuron Spectrum-6G removeDF-20A-HM Auto CPAP removeBRAINSWAY Deep TMS H1 Coil removeEctron Ectonustim Series 6 Electroconvulsive Therapy ECT Machine removeBRAINSWAY Deep TMS 104 RCT System removeNitrogen Generator/Plant remove
NameNeuron Spectrum-6G removeDF-20A-HM Auto CPAP removeBRAINSWAY Deep TMS H1 Coil removeEctron Ectonustim Series 6 Electroconvulsive Therapy ECT Machine removeBRAINSWAY Deep TMS 104 RCT System removeNitrogen Generator/Plant remove
Image
SKUSF1033560130187-8SF1033560130180-5SF1033560130162-4SF10335601235SF1033560130162-3SF103356013077
Rating
Price

$0.00

$0.00

$0.00

$0.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad The Neuron-Spectrum-6G by Neurosoft is an advanced EEG system developed from 30 years of engineering experience and cutting-edge technologies. It offers superior input noise levels, frequency and amplitude ranges, and sampling frequencies, outperforming many clinical EEG machines. Designed for seamless integration with transcranial magnetic stimulation (TMS), it effectively records EEG and evoked potentials during TMS sessions without signal disruptions.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad The VentMed DF-20A-HM Auto CPAP is designed for sleep apnea therapy, offering automatic pressure adjustment for comfortable breathing support. It includes a heated humidifier and has an ultra-low noise level of 22 dBA, ensuring quiet operation.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
The H1 Coil stimulates the bilateral prefrontal cortex, with a preference for the left dorsolateral prefrontal cortex. In addition to numerous published, double-blind, randomized controlled trials validating the efficacy of Deep TMS for depression, clinical data of over 1,000 patients in real practice settings has shown compelling results. Among patients who completed 30 sessions, approximately 4 out of 5 achieved a clinical response, and approximately 2 out of 3 achieved remission from depression.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad

This machines have been developed from the well-proven Series 5A and 5B ECT apparatus. The series 6+ models incorporate all the features of the corresponding Series 5B versions. Experience has shown that a very few patients sometimes require higher dosage than was available with the earlier machines and the opportunity was therefore taken to produce equipment with a second, higher, output range.

Delivery & Availability: Typically 3 Months – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad BrainsWay's 104 RCT System enables blinded clinical research via a card reader that randomizes selection of sham or Deep TMS stimulation. The sham coil is integrated into the helmet with the treatment coil, producing similar sounds and sensations.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
PSA Industrıal nitrogen generator systems produce gas nitrogen from compressed air from the field where they work, and switch compatible to conventional nitrogen gas source such as tubes or cryogenic liqiud. Delivery & Availability: Typically, 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Contenthttps://youtu.be/L5JdV0DrKQs  
Features
Innovative EEG recorder with outstanding technical specifications A new-generation EEG system, Neuron Spectrum-6G represents the 30-year experience of Neurosoft engineers and advanced technologies applied in the development of circuit solutions in medicine. The system outperforms most clinical EEG machines available today regarding such characteristics as input noise level, input frequency and amplitude range, and sampling frequency. Thanks to that and to the particularly developed software, it is possible to successfully use the system for TMS-EEG studies. The previous-generation EEG recorders usually went off-scale at the high-amplitude magnetic pulse and did not record an electroencephalogram. When designing this system, this disadvantage was fixed so that now the system allows recording of EEG and evoked potentials (EP) throughout a transcranial magnetic stimulation (TMS) session. Non-interfering monophasic magnetic stimulator For TMS-EEG sessions, we suggest using one of Neurosoft latest developments in magnetic stimulation. The monophasic stimulator ensures generation of high-amplitude pulses with high enough frequency. At the same time, its circuit is designed so that charging the capacitor does not cause additional interference in the EEG – the so-called “silent mode”. A variety of coils to choose from allow you to solve a wide range of clinical tasks. Electrode system An important success factor of the TMS-EEG technique is the appropriate electrode system. This solution offers a special electrode cap with the pre-defined electrode positions according to the 10-20 system for 21 or 32 EEG channels. The flat design of the electrodes allows positioning the coil as close to the head as possible, while the minimum metal content of the electrode allows minimizing artifact from the magnetic pulse on the EEG. Software for recording, averaging, and analysis  The Neuron-Spectrum.NET software implements the averaging of EPs induced by magnetic stimulation directly during recording. Automatic artifact removal from averaging allows obtaining pure responses for a minimum number of averagings. The latencies and amplitudes of EP components are calculated automatically and presented as tables and topographic maps. After the recording is completed, it is possible to change the filter parameters, perform averaging with different settings, for example, to remove pulse artifact from the averaged curves. The duration of a pulse artifact depends on the used electrodes, pulse intensity, and filter parameters. On average, artifact duration is 25 ms after pulse delivery, and immediately after that the system records pure EEG signal without interference. Wide application possibilities A few years ago when it became technically possible to record EEG during magnetic stimulation, TMS-EEG technique was only used in scientific research. Numerous works have now been published demonstrating the possibilities of this method in the treatment and diagnosis of various diseases. For example, TMS-EEG is widely used for evaluation of rehabilitation progress in stroke patients and helps in localization of the epileptic focus. The studies performed today using this technique allow suggesting that the scope of its application will expand even further in the future.
Specifications:
Feature Details
Work Modes CPAP, Auto
Pressure Range 4–20 cmH₂O (Auto Adjustment)
Noise Level 22 dBA (Ultra-low noise)
Humidifier Built-in, with optional heated tubing
Temperature Control 10-30°C (adjustable with built-in sensor)
Data Storage TF card & professional software for sleep reports
Alarms Various prompts for patient protection
Connectivity Optional Bluetooth oximeter & GPRS module
Accessories Included Nasal mask, power supply, carrying bag, air filter, TF card, user manual

This device is lightweight and user-friendly, featuring an intuitive display and advanced noise-canceling technology for a comfortable sleep experience

The BrainsWay Deep TMS H1 Coil is a transcranial magnetic stimulation (TMS) device that's used to treat depression and other mental disorders: 
  • Design
    The H1 Coil is a flexible, soft copper coil that's placed inside a helmet to stimulate the brain. The coil's design allows for a wider and deeper distribution of magnetic fields than traditional TMS coils.
  • Effectiveness
    The H1 Coil is effective in treating depression and has also been explored as a treatment for other conditions:
    • DepressionThe H1 Coil is FDA-cleared to treat major depressive disorder (MDD) in adults who haven't responded well to other antidepressant medications.
    • Other conditionsThe H1 Coil has been explored as a treatment for negative symptoms of schizophrenia, bipolar depression, and migraine.
  • Benefits
    The H1 Coil's design allows for greater neuron activation, which can lead to more effective stimulation and fewer targeting errors.
  • Safety
    The H1 Coil is considered a safe and effective clinical tool.
Features
  • Flexible base
    The H1 coil has a flexible base that can adapt to the shape of the patient's head. 
  • Tangential coil components
    The H1 coil has tangential coil components that are close to the brain targets. 
  • Parallel coil components
    The H1 coil has parallel coil components that direct the electric pulse beams. 
  • Electrical pulses
    The H1 coil has numerous electrical pulses that converge from various directions. 
  • Return paths
    The return paths of the electrical pulses are located at a distance from the target area. 
  • Stimulates the prefrontal cortex
    The H1 coil stimulates the bilateral prefrontal cortex, with a preference for the left dorsolateral prefrontal cortex (DLPFC). 
  • Deeper and broader stimulation
    The H1 coil's patented design enables deeper and broader stimulation than traditional TMS coils.
    Click here to download Brochure
This machines have been developed from the well-proven Series 5A and 5B ECT apparatus. The series 6+ models incorporate all the features of the corresponding Series 5B versions. Experience has shown that a very few patients sometimes require higher dosage than was available with the earlier machines and the opportunity was therefore taken to produce equipment with a second, higher, output range. Features: Constant Current stimulus Delivered Dosage Displayed Patient Dynamic Impedance Indicator Simple Single Dose Control Technical Specification: Input Supply: AC 100-120, 210-240 V 40/60 Hz Load: 70 W Apparatus Size: 305 x 170 x 105mm (12” x 6.5” x 4”) Weight: 3.24kg Low Range: 50-700mC @ 750mA High Range: 200-100mC @ 900mA Contents: Two-hand headpiece: 1 C.S lead: 1 Disposable electrodes: 50 Mains cable: 1 Operating & service manual: 1 Removable stand: 1  
Click Here To Download Catalogue
The BrainsWay Deep TMS 104 RCT System is a non-invasive treatment for mental health conditions that uses magnetic pulses to stimulate the brain.
  • ComponentsIncludes a stimulator, touchscreen interface, cooling system, and card reader 
  • TreatmentPatients wear a helmet with electromagnetic coils that deliver magnetic pulses to the brain 
  • PurposeTreats conditions like major depressive disorder (MDD), obsessive-compulsive disorder (OCD), and smoking cessation 
  • SafetyWell-tolerated treatment with a favorable safety profile 
  • EffectivenessResearch shows that Deep TMS is effective in alleviating symptoms 
  • InsuranceMany insurance providers offer coverage for Deep TMS 
  • Ease of useDesigned to be easy to use for operators and comfortable for patients 
  • Sham-enabledVersions are available for randomized controlled clinical research 
 
Features
The BrainsWay Deep TMS 104 RCT System has several features, including:
  • H-CoilsThe system's patented H-Coils are flexible and embedded in a cushioned, cooled helmet that fits each patient's head. The H-Coils provide deeper and broader stimulation than traditional TMS coils, which are rigid and shaped like a figure-8. 
  • Touchscreen interfaceThe system has an intuitive touchscreen interface. 
  • Cooling systemThe system has an efficient cooling system. 
  • Card readerThe system has a card reader that randomly selects sham or Deep TMS stimulation. 
  • Sham-enabled versionsSham-enabled versions are available for randomized controlled clinical research.
 

Click here to download Brochure 

PSA Industrıal nitrogen generator systems produce gas nitrogen from compressed air from the field where they work, and switch compatible to conventional nitrogen gas source such as tubes or cryogenic liqiud.

ADVANTAGES OF NITROGEN GENERATORS/PLANT

  • High flow capacity: The wide product range and gas flows exceeding 1,000 Nm³/h

  • Desired purity: Nitrogen concentrations from 95% to 99.999%.

  • Continuous availability: 24 hours a day, 7 days a week

  • Cost savings: Low operating expenses, limited maintenance costs.

  • Fully automated and monitored including oxygen sensor as standard.

Wide Range Of Applications

  • Food & beverage (storage & packaging).

  • Pharmaceutical applications.

  • Plastic injection molding.

  • Electronics.

  • Laser cutting.

  • Semiconductor manufacturing.

  • Chemical applications.

  • Metal heat treatment.

  • Cable & optical fiber industries.

  • Glass industries.

  • Fire prevention.

  • Aquaculture.

grafik_son.jpg
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare