OBS-100A Monopolar Electrosurgical Unit

$0.00

Shipped From Abroad

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130165-7
Brands:: OBS

Description

 

Features

1. Portable and  affordable

2. Suitable for general surgery and veterinary

Technical Details
Environmental temperature range: 5°C~ 40°C
Relative moisture range: ≤80%
Atmosphere pressure range: 86.0 Kpa ~ 106.0 Kpa

Working modes:

Pure cut: 5w ~ 100w (Load:300Ω)
Blend cut: 5w ~ 50w (Load:300Ω)
Forced coagulation: 5w ~ 80w (Load:500Ω)
Soft coagulation: 5w ~ 50w (Load:500Ω)

Technology data:

Voltage: 230V±10V, 50Hz
Working frequency: 330KHz ~ 460KHz
Leakage currents to ground: Less than 0.5mA
Leakage currents to patient: Less than 0.01mA

Reviews

There are no reviews yet.

Be the first to review “OBS-100A Monopolar Electrosurgical Unit”

Your email address will not be published. Required fields are marked *

Quick Comparison

OBS-100A Monopolar Electrosurgical Unit removeElectrosurgical Bipolar Forceps removeBipolar Irrigated Coagulator removeOBS-100C(II) Cold RF Unit removeOBS-100C LCD Version Dual cold RF Electrosurgical Unit removeDisposable Skin Stapler remove
NameOBS-100A Monopolar Electrosurgical Unit removeElectrosurgical Bipolar Forceps removeBipolar Irrigated Coagulator removeOBS-100C(II) Cold RF Unit removeOBS-100C LCD Version Dual cold RF Electrosurgical Unit removeDisposable Skin Stapler remove
Image
SKUSF1033560130165-7SF1033560130165-18SF1033560130165-12SF1033560130165-6SF1033560130165-1SF1033560130165-21
Rating
Price

$0.00

$0.00

$0.00

$0.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad Electrosurgical Bipolar Forceps are specialized surgical instruments used in electrosurgery. They have two electrodes at the tips, which allow for precise control of electrical current to coagulate, cut, or seal tissue with minimal damage to surrounding areas.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad OBS-100C(II) uses high-frequency radio wave technology as an energy source to cut and coagulate soft tissue. it operates at 3.8MHz, enabling a precise incision with significantly less heat and resultant heat damage than typically found with conventional electrosurgery. Since tissue stays cooler with high-frequency radio wave technology, you can feel confident that you are minimizing cellular destruction along the incision path.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad Unique dual radio frequency design. Combines 4Mhz and 1.7Mhz into one generator. Realizes the best operation result effectively. Suitable for  Plastic, Dermatology, ENT, Ophthalmology, Dentistry, Podiatry and Spinal surgery
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Sterile Disposable Skin Stapler is a disposable equipment that applies to skin sutures during general surgical operation, Cardiothoracic Surgery, plastic surgery, neurosurgery operation, gynecologic surgery, burn surgery, emergency operation, and field rescue. It can be used in operating room, delivery room, emergency department, outpatient surgery, and clinics.
Content  
Features

1. Portable and  affordable

2. Suitable for general surgery and veterinary
Technical Details
Environmental temperature range: 5°C~ 40°C
Relative moisture range: ≤80%
Atmosphere pressure range: 86.0 Kpa ~ 106.0 Kpa
Working modes:
Pure cut: 5w ~ 100w (Load:300Ω)
Blend cut: 5w ~ 50w (Load:300Ω)
Forced coagulation: 5w ~ 80w (Load:500Ω)
Soft coagulation: 5w ~ 50w (Load:500Ω)
Technology data:
Voltage: 230V±10V, 50Hz
Working frequency: 330KHz ~ 460KHz
Leakage currents to ground: Less than 0.5mA
Leakage currents to patient: Less than 0.01mA
 
Features:
  1. Two Electrodes: The tips of the forceps act as both the active and return electrodes.
  2. Precision Control: Allows for targeted application of electrical energy.
  3. Reduced Risk of Burns: The current is confined between the forceps, minimizing the risk of accidental burns.
  4. Reusable: Often made from stainless steel or titanium and can be sterilized for multiple uses.
  5. Variety of Designs: Available in straight, angled, and bayonet styles to suit different surgical needs.
Uses:
  1. Coagulation: Used to stop bleeding by coagulating blood vessels.
  2. Tissue Cutting: Can be used to cut tissue with precision.
  3. Sealing: Effective in sealing blood vessels and tissue bundles.
  4. Versatility: Used in various surgical fields such as general surgery, gynecology, neurosurgery, and ENT (Ear, Nose, and Throat) surgery.
Features

1. LED light positioned between the electrodes enhances the vision during surgery.

2. Massive area hemostasis can be performed in a short time in order to reduce intraoperative blood loss 3. Saline line and dripping device are equipped in an attempt to contain the heat on the treated tissue and avoid thermal tissue damage
Indications for Use
  • Ensure that both electrodes are in contact with the tissue to be treated. Activation and saline flow occur simultaneously.
  • Ensure that saline is flowing at the time of activation
  • These devices should never be used when:
  • There is visible evidence of damage to the exterior of the device such as cracked or damaged plastic or connector damage.
  • These devices fail the inspection described herein.
  • In the presence of flammable gases, flammable prep solutions or drapes. Oxidizing. Gases such as Nitrous Oxide (N2O), or in oxygen-riched environments.
  • Do not use monopolar electrosurgery on small appendages, as in circumcision or finger surgery.
Features
  • Clinic result proves that higher frequency can get less tissue resists nee. 4Mhz frequency can reduces heat injury a ind carbonizing to tissue at maximum. It realizes low temperature cutting.
  • The antenna pad is unnecessary for skin touch, no current goes through the body, and no possibility of burning
  • No pressure cutting and the pencil is operated easily and it's full of flexibility.
  • No carbonation, less bleeding, and no adhesions.
  • Less pain, scarring, and fast healing after operation.
Technical Parameters
Image
Product Details
OUTPUT MODE 
  • CUT - For micro-smooth cutting
  • BLEND - For cutting with coagulation
  • HEMO - For pure Hemostasis-Coagulation to control most forms of bleeding
  • FULGURATION - For desiccation or fulgurate spark-gap
  • BIPOLAR - For precise coagulation utilizing bipolar energy
INTENDED USE
  • Cutting: snoring, submucosal palatal shrinkage, traditional uvulopalatoplasty (RAUP), myringotomy with effective hemorrhage control, epistaxis treatment, turbinate shrinkage, skin incisions, biopsy, cysts, abscesses, tumors, cosmetic repairs, development of skin flaps, skin tags and blepharoplasty.
  • Blended (cutting and coagulation): snoring, submucosal palatal shrinkage, traditional uvulopalatoplasty (RAUP), myringotomy with effective hemorrhage control, epistaxis treatment, turbinate shrinkage, skin tags, papilloma keloids, keratosis, verrucae. basal cell carcinoma, nevi, fistulas, epithelioma, cosmetic repairs, cysts, abscesses, and development of skin flaps.
  • Hemostasis: control of bleeding, epilation, telangiectasia.
  • Fulguration: basal cell carcinoma, papilloma, cyst destruction, tumors, verrucae, hemostasis.
  • Bipolar: pinpoint precise coagulation, pinpoint hemostasis in any field (wet or dry), snoring, submucosal palatal shrinkage, traditional uvulopalatoplasty (RAUP), myringotomy with effective hemorrhage control, epistaxis treatment and turbinate shrinkage.
Transportation Data :
  • WxHxD:34(L)'23.5(W)*10.6(H) 49(L)*35.5(W)'31(H)cn Weight:8.2kg(NetWeight);12. cm(Generator) i(outer carton) 1kg(Gross Weight)
  • Standard Matching Accessories
  • Instruction for Use: 1pc
  • Power Cord: 1pc
  • Dual Pedal Switch: 1pc
  • Disposable ESU Pencil: 2 pes
  • Reusable Antenna Pad with cable: 1 set
  • Reusable Bipolar Forceps with Cable: 1 set
  • Reusable ESU pencil: 1 pc
  • Reusable Fine Electrode tips (Needle, curved, Needle .Ball): 7pcs
  • Disposable leep Electrode tips: 5pcs
Features
  • Concise and reasonable design, which is easy and convenient to operate.
  • Safe and efficient for surgery, and the needle could be withdrawn fluently and accurately.
  • Smooth and beautiful suture, small and micro healing scar.
  • There's good compatibility with tissues and less inflammatory response.
  • It's easy and convenient to take out the stitches, which will promote wound healing.
  • Sterile Disposable Skin Stapler reduces the patient's pain and improves operation efficiency.
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare