Description

HIGH INTELLIGENCE AND RELIABLE POWER SUPPLY

IGBT Technology
Full microprocessor control with no-break static and manual bypasses.
Online double conversion technology (VFl) with isolation transformer on theinverter output.
Extremely high short-circuit current to ensure compatibility with the most diffificult transformer applications (lighting, drives and industrial processes) and an isolation transformer on the inverter output.
Compatibled with Watch & Save 3000 software as standard and can be remotely monitored using the Power NetGuard system from anywhere in the world.

SIMPLE TO INSTALL

Capability to install the UPS into any distribution system(neutral not required on rectifier input).
Capability to separate the rectifier/bypass power networks and to power them from two separate sources, without Galvanic isolation(Necessary on UPS without an output transformer

MAXIMUM BATTERY CARE

Battery deep discharge protection;
Temperature compensating charger;
Built-in automatic and manual battery test feature.

OTHER CHARACTERISTICS

0.8/0.9 power factor suitable for powering ICT and lndustrial loads.
BACK FEED protection: to avoid energy feeding back into the mains supply cause a fault occur.

MAXIMUM RELIABILITY AND AVAILABILITY

Connect up to 6 units in parallel or N+1 redundancy, even of different power ratings.
The UPS continue to work in parallel even if one of theinterconnecting communication cables is disconnected(CLOSED LOOP)

LOW CONSUMPTION LEVELS

LF33 Series UPS can achieve efficiencies >98% thanks to selectable Economy Mode which can be used in stable electrical environments to provide power supply continuity when the mains fail.

ADVANCE COMMUNICATION:

RS485/RS232/Dry Contact/SNMP(Optional)

 

Specifications
Model 10KVA 20KVA 30KVA 40KVA 60KVA 80KVA 100KVA 120KVA 160KVA 200KVA 250KVA 300KVA 400KVA 500KVA 600KVA
Capacity 8KW 16 KW 24 KW 32 KW  48 KW 64 KW  80 KW 96 KW 128 KW 160 KW 200KW 240KW 320KW 400KW  480KW
INPUT
Rated voltage 400 VAC  Three-Phase
Voltage range 380/400/415VAC(+25%,Can be set through the LCD panel)
Frequency range 40-70Hz(Automatically select synchronization range according to grid frequency)
Range(HZ) 50±5%(±10%) Bypass synchronization tracking
Rectifying pulse number 6 pulse rectification 6/12 pulse rectification 12 pulse rectifier
Phase system 3φ4W+PE(Three phase five wire system)
Battery voltage 384VDC 480VDC
Battery Quantity Standard with 32 Cells(30~34, can be set through the LCD panel)  Standard 40 Cells(38~42 knots,can be set by LCD panel)
OUTPUT
Power factor 0.8/0.9 (Optional)
Voltage(V) L-N: 220±1%   L-L: 380±1%
Three-phase 100% load
unbalance voltage stability
≤2%,Allow 100% imbalance
Frequency(HZ) Normal power, tracking the frequency of power, Grid abnormal. 50±0.2%
Transfer time(ms) 0ms
Parallel operation mode
(parallel type)
Max 8 Parallel
Waveform distortion Linear loadTHD<3% ; Nonlinear loadTHD<5%
Overload capacity 125% full load for 10 minutes, maintain 150 % full load for 1 minute and then switch to bypass power supply,
after reducing the loadcan automatically restore the inverter
Crest factor 3:1
Others
Index Standard with no transfer time maintenance bypass switch
Communication function RS232/RS485/Dry Contact/SNMP (Optional)
Panel display LED displays working status and fault indication; LCD displays three-phase input voltage,
input frequency, three-phase output voltage, load,battery voltage, battery charge and discharge current, etc
Display  7″ Touchable LCD screen display
The audio noise(dB) <65(within 1 meter)
Alarm function Battery low voltage, abnormal power supply, overload, UPS failure, over temperature protection
Protection Input over voltage, battery under voltage, overload, short circuit, over temperature protection
Cooling way Forced cooling
Operating temperature 0℃ to  ~ 40℃
Humidity 0~95%, non-condensing
electromagnetic compatibility Conform GB7260.2
Size(W*D*H)(mm) 540*660*1135 1100*800*1800 800*800*1900 1200*850*1900 2600*1100*2000
Weight 196     233 276 329 461 547.5 643 754 1375

Reviews

There are no reviews yet.

Be the first to review “3 Phase Low Frequency Online UPS LD33 Series”

Your email address will not be published. Required fields are marked *

Quick Comparison

Settings3 Phase Low Frequency Online UPS LD33 Series removeLead Acid Maintenance Free Battery 5AH-250AH removeHigh Frequency Modular UPS VM Series removeLine Interactive UPS DP Series 600VA-3000VA removeDC UPS with POE Port 18W 36W with 10400mah Lithium Battery remove3 Phase Low Frequency Online UPS LF33 Series remove
Name3 Phase Low Frequency Online UPS LD33 Series removeLead Acid Maintenance Free Battery 5AH-250AH removeHigh Frequency Modular UPS VM Series removeLine Interactive UPS DP Series 600VA-3000VA removeDC UPS with POE Port 18W 36W with 10400mah Lithium Battery remove3 Phase Low Frequency Online UPS LF33 Series remove
Image
SKUSF1033560130139-3SF1033560130139-15SF1033560130139-11SF1033560130139-17SF1033560130139-6SF1033560130139-4
Rating
Price

$0.00

$0.00

$0.00

$0.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
f
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Features:
  • Intelligent CPU control
  • Automatic power on when the the main power recovers
  • Cold start function
  • Power off charging function
  • USB/RS232/RJ-11/RJ-45 communication port (optional)
  • Offering LED and LCD panels for selection
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Features:
  • Wide AC input voltage range 85~265Vac.
  • Inbuilt 4* 2600mah lithium battery to support longer power supply for loads.
  • DC output interfaces support USB (5V) /9V/12V/ 15V/24V (POE)
  • Ethernet power supply: one network cable can transmit data and electric power at the same time.
  • Over-charging, Over-discharging and Short Circuit protection
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Features:
  • Optional 7 ” touch LCD
  • Online double-conversionDSP technology guarantees high reliability
  • True galvanic isolation transformer designControl designed to withstand all kinds of loads
  • Intelligent battery management to prolong battery lifecycle
  • Redundant fan design and independent ventilation enhance durable operation under harsh environment
  • Adiustable battery numbers
  • Accept dual-mains input
  • Parallel operation with up to 4 units ( option )
  • Variety of communication options available
  • Reverse phase frequency operation and supportsnon-neutral input
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Description
HIGH INTELLIGENCE AND RELIABLE POWER SUPPLY IGBT Technology Full microprocessor control with no-break static and manual bypasses. Online double conversion technology (VFl) with isolation transformer on theinverter output. Extremely high short-circuit current to ensure compatibility with the most diffificult transformer applications (lighting, drives and industrial processes) and an isolation transformer on the inverter output. Compatibled with Watch & Save 3000 software as standard and can be remotely monitored using the Power NetGuard system from anywhere in the world. SIMPLE TO INSTALL Capability to install the UPS into any distribution system(neutral not required on rectifier input). Capability to separate the rectifier/bypass power networks and to power them from two separate sources, without Galvanic isolation(Necessary on UPS without an output transformer MAXIMUM BATTERY CARE Battery deep discharge protection; Temperature compensating charger; Built-in automatic and manual battery test feature. OTHER CHARACTERISTICS 0.8/0.9 power factor suitable for powering ICT and lndustrial loads. BACK FEED protection: to avoid energy feeding back into the mains supply cause a fault occur. MAXIMUM RELIABILITY AND AVAILABILITY Connect up to 6 units in parallel or N+1 redundancy, even of different power ratings. The UPS continue to work in parallel even if one of theinterconnecting communication cables is disconnected(CLOSED LOOP) LOW CONSUMPTION LEVELS LF33 Series UPS can achieve efficiencies >98% thanks to selectable Economy Mode which can be used in stable electrical environments to provide power supply continuity when the mains fail. ADVANCE COMMUNICATION: RS485/RS232/Dry Contact/SNMP(Optional)  
Specifications
Model 10KVA 20KVA 30KVA 40KVA 60KVA 80KVA 100KVA 120KVA 160KVA 200KVA 250KVA 300KVA 400KVA 500KVA 600KVA
Capacity 8KW 16 KW 24 KW 32 KW  48 KW 64 KW  80 KW 96 KW 128 KW 160 KW 200KW 240KW 320KW 400KW  480KW
INPUT
Rated voltage 400 VAC  Three-Phase
Voltage range 380/400/415VAC(+25%,Can be set through the LCD panel)
Frequency range 40-70Hz(Automatically select synchronization range according to grid frequency)
Range(HZ) 50±5%(±10%) Bypass synchronization tracking
Rectifying pulse number 6 pulse rectification 6/12 pulse rectification 12 pulse rectifier
Phase system 3φ4W+PE(Three phase five wire system)
Battery voltage 384VDC 480VDC
Battery Quantity Standard with 32 Cells(30~34, can be set through the LCD panel)  Standard 40 Cells(38~42 knots,can be set by LCD panel)
OUTPUT
Power factor 0.8/0.9 (Optional)
Voltage(V) L-N: 220±1%   L-L: 380±1%
Three-phase 100% load unbalance voltage stability ≤2%,Allow 100% imbalance
Frequency(HZ) Normal power, tracking the frequency of power, Grid abnormal. 50±0.2%
Transfer time(ms) 0ms
Parallel operation mode (parallel type) Max 8 Parallel
Waveform distortion Linear loadTHD<3% ; Nonlinear loadTHD<5%
Overload capacity 125% full load for 10 minutes, maintain 150 % full load for 1 minute and then switch to bypass power supply, after reducing the loadcan automatically restore the inverter
Crest factor 3:1
Others
Index Standard with no transfer time maintenance bypass switch
Communication function RS232/RS485/Dry Contact/SNMP (Optional)
Panel display LED displays working status and fault indication; LCD displays three-phase input voltage, input frequency, three-phase output voltage, load,battery voltage, battery charge and discharge current, etc
Display  7″ Touchable LCD screen display
The audio noise(dB) <65(within 1 meter)
Alarm function Battery low voltage, abnormal power supply, overload, UPS failure, over temperature protection
Protection Input over voltage, battery under voltage, overload, short circuit, over temperature protection
Cooling way Forced cooling
Operating temperature 0℃ to  ~ 40℃
Humidity 0~95%, non-condensing
electromagnetic compatibility Conform GB7260.2
Size(W*D*H)(mm) 540*660*1135 1100*800*1800 800*800*1900 1200*850*1900 2600*1100*2000
Weight 196     233 276 329 461 547.5 643 754 1375
Features:
Nomimal voltage: 12V Rated Capacity: 5Ah ~ 250Ah Operating temperature range: -15 ~ 45 ℃ The design life is 5 years Using new special process sheet formula to improve the utilization of active material Using high quality superfine glass fiberliquid-suction battery technology to exceed 99% gas recombination rate High-strength ABS plastic battery slot and cover with features of compact structure, corrosion resistant, impact resistance and anti-vibration and so on Small internal impedance, excellent performance when high current discharge Low self-discharge, wide operating temperature range Using multiple sealing technologies to ensure no leakage, no acid mist escaping to keep safe and reliable Using strict production process, unit voltage balance is strong Free maintenance, without adding water rehydration  
Technical Specifications
Model Nominal Voltage Capacity Dimension LXWXH (mm) Total Height (mm) Weight (KG) Terminal
VL12-24 12 24 166 175 125 125 8 M6
VL12-28 12 28 166 175 125 125 9 M6
VL12-33 12 33 196 130 163 180 10 M6
VL12-35 12 35 197 130 163 180 10.5 M6
VL12-40 12 40 197 166 171 171 13.5 M6
VL12-44 12 44 196 166 171 171 13.5 M6
VL12-55 12 55 230 138 211 229 17.2 M6
VL12-65 12 65 350 166 179 179 22 M6
VL12-70 12 70 260 169 211 229 23 M8
VL12-80 12 80 260 169 211 229 24 M8
VL12-90 12 90 307 169 211 234 28 M8
VL12-100 12 100 331 173 213 233 32 M8
VL12-120 12 120 407 174 209 233 3, 8 M8
VL12-130 12 134 341 173 283 287 41 M8
VL12-150 12 150 484 171 241 241 46 M8
VL12-160 12 160 534 209 216 237 52 M8
VL12-180 12 180 530 209 216 237 56 M8
VL12-200 12 200 522 240 220 244 64 M8
VL12-230 12 230 520 268 220 240 72.5 M8
VL12-250 12 250 520 268 220 249 76 M8
Features:
Digital Control All parts of this series of UPS adopt digital control, each performance index of UPS is very excellent, and the control system is morestableand reliable.Each module has built-in automatic bypass switch and corresponding bypass current equalizing inductor, providing good bypass power supply equalization performance. Intelligent Battery Management Users can set the charging current, constant current, constant voltage and floatingcharging modescan be automatically and smoothly switched; Battery voltage can beset ±192Vdc/±240Vdc/±216Vdc/±228Vdc/±240Vdc (32/34/36/38/40 pcs optional) High Power Density Modular Design The capacity of each single module is30kVA, and the height is3U; UPS modulescan be added and removed onlineto achieve zero maintenance time. N+x Parallel Redundancy The quantity of redundant module can be set accordingly, When the redundant module reaches more than 2 hours, the system availability achieves 99.99%, MTBF(Mean Time Between Failures) lasts more than 250,000 hours; Supporting parallel connection between cabinets. A maximum of four cabinets can be parallel,and battery pack can be shared when UPS cabinet in parallel. Touchable LCD Display Screen Super large LCD display with touching function. Standard Cabinet Design The appearance ofthe standard cabinet is beautiful and generous, which can perfectly match the use environment ofthe computer room and save the space.

Safe and Easy to Maintain When an emergency occurs, users can switch to the maintenance bypass to supply power, and maintenance personnel can safely perform online maintenance; Press EPO button to shutdown in emergentsituation, and also have REPO function. Intelligent Management Centralized monitoring module (with hot-swap function), RS232/RS485 communication interface/SNMPcard (optional), can realize remote monitoringof UPS, relay card is optional.

 
Technical Specifications
Model VM 90K VM150K VM300K
Capacity UPS Cabinet 30-90KVA 30-150KVA 30-300KVA
Power Module 30kVA
INPUT Input Form 3P4W+G
Rated Voltage 380/400/415Vac
Voltage Range 207~478Vac
Frequency Range 40~70Hz
Input Power Factor ≥0.99
Bypass Range 380 upper limit: 25% (optional +10%s +15%、+20%) 400 upper limit: 20% (optional +10%、+15%) 415 upper limit: 15% (optional +10%) Lower limit: -45% (optional -20%s -30%) Bypass frequency protection range: ± 10%
Input Current Harmonic Wave ≤3% (100% non-linear)
OUTPUT Output Form 3P4W+G
Rated Voltage 380/400/415Vac
Output Power Factor 0.9 or 1
Voltage Accuracy ±1%
Output Frequency Mains Mode Synchronization with input; when mains frequency exceeds maximum value ±10% (can be set ±1%、 ±2%、±4%、±5%), output frequency 50X(±0.2%)Hz
Battery Mode (50/60±0.2%) Hz
Crest Factor 3:1
Conversion Time Mains mode — bypass mode: 0ms (tracking); Mains mode— battery mode: 0ms
Overload Capacity Load≤110%: 60 mins; Load≤125%: 10 mins; Load≤150%: 1 min; Load≥150%, shutdown immediately
Output Voltage Harmonic Wave ≤2% (100% linear)
Efficiency In normal mode 95%
Communication Port RS232、RS485、 Intelligent Slot*2 、 Dry connect port
BATTERY Battery Voltage ±192Vdc/±204Vdc/±216Vdc/±228Vdc/±240Vdc; (32/34/36/38/40pcs Optional)
Charging Current UPS Cabinet 30A Max 50A Max 100A Max
Power Module 10A Max
Environment Operating Temperature 0〜40°C
Relative Humidity 0-95% (non-condensing)
Storage Temperature -25-55°C (excluded battery)
Altitude < 1500m (derating if exceeding 1500m)
Physical Characteristic Outer Dimension (LxWxH) mm Cabinet 840X600X1400 1100X600X2000
Module 580 X 443 X 131
Weight (Net Weight) KG Cabinet 158 170 305
Module 33.5
Operative Standard YD/T 2165-2010
Features:
  • Intelligent CPU control
  • Automatic power on when the the main power recovers
  • Cold start function
  • Power off charging function
  • USB/RS232/RJ-11/RJ-45 communication port (optional)
  • Offering LED and LCD panels for selection
 
Application:
  • Personal Computer
  • Printer
  • POS(Point of sales)Terminals
  • Security System
  • Fax Machine
  • Modem, WiFi Router
 
Technical Specifications:
 
Model DP600 DP1000 DP1200 DP2000 DP3000
Capacity 600VA/360W 1000VA/600W 1200VA/720W 2000VA/1200W 3000VA/1800W
INPUT
Voltage 110/120VAA or 220/230/240VAC
Voltage Range 67-137VAC/135-275VAC
Frequency Range 50Hz Or 60Hz(Auto-Sensing)
OUTPUT
Output Voltage 110/120VAA or 220/230/240VAC
AC Voltage Regulation ± 10%
Frequency Range (Batt. Mode) 50 HZ or 60 Hz ± 10%
Transfer Time Typical 6-10 ms
Waveform (Battery Mode) Simulated Sine Wave
BATTERY
Battery Voltage 12V/7AH*1 12V/9AH*1 12V/7AH*2 12V/9AH*2 12V/7AH*4
Charge Time 8 hours up to 80-90%
PROTECTION
Full Protection Auto Detection, discharge protection,output Short circuit, Over load, Battery low voltage protection
 Communication Port USB/RS232/RJ11/RJ45  (Optional)
Display LED/LCD
          Alarm
Battery Mode Every 4 Seconds one beep
Low Battery Capacity Every 1 Seconds one beep
Overload Every 1 Seconds one beep
Fault Keep beeping
ENVIRONMENT
Humidity 0-90% Rh @ 0-40℃ (Non-Condensing)
Noise Level 40dB
Dimension(mm) 320*90*140 330* 100*150 365*140*165 365*140*165 395*145*210
N.W.(kg) 5.2 6 10 12.6 21
Features:
  • Wide AC input voltage range 85~265Vac.
  • Inbuilt 4* 2600mah lithium battery to support longer power supply for loads.
  • DC output interfaces support USB (5V) /9V/12V/ 15V/24V (POE)
  • Ethernet power supply: one network cable can transmit data and electric power at the same time.
  • Over-charging, Over-discharging and Short Circuit protection
 
Specifications
Model DC 1018P DC 1036P
INPUT
Input Voltage 85 – 265Vac
Output
DC Output Voltage 5V             2A 5V             2A
USB            2A USB            2A
9V             1A 9V             1A
12V             1A 12V             1A
15V/24V(POE)       0.5A 15V/24V(POE)       0.5A
18W 36W
BATTERY
Battery Type Lithium Battery
Capacity of Battery 2600mAh * 4
PROTECTION
Protect Over-charging, Over-discharging and Short Circuit
ENVIRNMENT
Operation Temperature 0°C – 40°C
Noise Level Less than 40dB
Dimension(mm) 160 * 105 * 33
Net Weight(kg) 0.40 0.42
Features:
  • Optional 7 ” touch LCD
  • Online double-conversionDSP technology guarantees high reliability
  • True galvanic isolation transformer designControl designed to withstand all kinds of loads
  • Intelligent battery management to prolong battery lifecycle
  • Redundant fan design and independent ventilation enhance durable operation under harsh environment
  • Adiustable battery numbers
  • Accept dual-mains input
  • Parallel operation with up to 4 units ( option )
  • Variety of communication options available
  • Reverse phase frequency operation and supportsnon-neutral input
 
Specifications
MODEL LF33 10K LF33 20K LF33 30K LF33 40K LF33  60K LF33  80K LF33 100K LF33 120K LF33 160K LF33 200K
CAPACITY 10KVA /8KW 20KVA /16KW 30KVA /24KW 40KVA /32KW 60KVA /48KW 80KVA /64KW 100KVA /80KW 120KVA /96KW 160KVA /128KW 200KVA /160KW
INPUT
Nominal Voltage 3 x 380VAC/400VAC (3Ph + N)
Acceptable Voltage Range 305VAC ~ 460VAC
Frequency 46-54Hzor56-64Hz
INVERTER
Nominal Voltage 3 x 380VAC/400VAC (3Ph + N)
Precision Stationary: ±1% Transitory: ±5% (load variations 100-0-100%)
Frequency 50/60 Hz synchronised ±1 % With mains absent ±0.1 Hz
Max. Synchronisation Speed ±1 Hz/s
Waveform Pure Sinewave
Total Harmonic Distortion (THDv) <2% (Linear Load) ; <5% (Non-linear Load)
Phase Displacement 120° ±1 % (balanced load); 120° ±2% (imbalances 50% of the load)
Dynamic Recovery Time Restore to 90% of rated value in 3 cycles
Overload capacity 110% for 10min; 150% for 60sec; >160% for 200ms
Admissible Crest Factor 3:1
Admissible Power Factor 0.6-1 (inductive or capacitive)
Imbalance Output Voltage @ 100% Unbalanced Load                    <1%
Current Limit High overload, short-circuit: RMS Voltage Limit; High Crest-Factor current: Peak Voltage Limit
STATIC BYPASS
Type Solid state
Voltage 3 x 380VAC/400VAC (3Ph + N)
Frequency 50/60 Hz
Activation Criterion Microprocessor control
Transfer Time Zero
Admissible Overload 150% for 1 hour; 180% for 30sec; >200% for 200ms
Transfer to Bypass Immediate, for overloads above 160%
Retransfer Automatic after alarm clear
MAINTENANCE BYPASS
Type Without interruption
Voltage 3 * 400V (3Ph + N)
Frequency 50/60 Hz
Overall Efficiency Line Mode 90% 91% 92% 93%
Battery Mode 90% 91% 93% 93%
BATTERY & CHARGER
Battery Type and Numbers 12VDC * 32 pcs (29-32 pcs adjustable)
Nominal Battery Voltage 384 VDC (Based on 32pcs batteries)
Charging Method CC/CV
Precision ±1%
Charging Current Max.: 40 A
Charging Voltage 432 VDC (Based on 32pcs batteries)
PHYSICAL
Dimensions, D x W x H(mm) 656 x 405 x 817 656 x 405 x 941 840x432x1140 975x554x1286 1200x910x1680 1500x1140x1800
Net Weight (Kgs) 180 205 295 330 451 519 950 1350
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar