3 Phase Low Frequency Solar Inverter DX Series

$0.00

SF1033560130139-5
Brands:: Reeco Power

Description

Features:

Three Phase Hybrid Solar Inverter

Off grid three phase solar hybrid inverter with pwm/mppt can be used in single-phase and three-phase ac load with total power not exceeding  100kva/120kva/125kva/150kva/160kva,384vdc to 380vac.

•Pure sine wave output.
•Low DC voltage, saving system cost.
•Three phase solar inverter with built-in PWM or MPPT charge controller.
•AC charge current 0-45A adjustable.
•Wide LCD screen, clearly and precisely shows icon data.
•100%imbalance loading design, 3 times peak power.
•Setting different working modes based on variable usage requirements.
•DC first/AC first optional.
•Various communication ports and remote controls

 

Specifications
MODEL DX100KVA DX120KVA DX125KVA DX150KVA DX160KVA 190KVA 200KVA
Rated Power 80KW 96KW 100KW 120KW 128KW 150KW 160KW
Peak Power(20ms) 240KVA 288KVA 300KVA 360KVA 384KVA 450KVA 480KVA
Start Motor 40HP 50HP 50HP 60HP 60HP 80HP 80HP
Battery Voltage 384VDC
Size(L*W*Hmm) 875*720*1380 1123*900*1605
Packing Size(L*W*Hmm) 980*825*1560 1185*960*1750
N.W.(kg) 512 592 612 612 642 705 755
G.W.(kg)(Wooden Packing) 552 632 652 652 692 755 805
INPUT DC Input Voltage Range 10.5VDC-15VDC(Single battery voltage)
AC Input Voltage Range 380Vac/400Vac±10%(customized 190Vac/200Vac)
AC Input Frequency Range 45Hz-55Hz(50Hz)/ 55Hz-65Hz(60Hz)
Max AC charging current 0-45A(Depending on the model)
AC charging method Three-stage (constant current, constant voltage, floating charge)
Phase 3 PHASE
OUTPUT Efficiency(Battery Mode) ≥85%
Output Voltage(Battery Mode) 380Vac/400Vac±10%(customized 190Vac/200Vac)
Output Frequency(Battery Mode) 50/60Hz ±1%
Output Wave(Battery Mode) Pure Sine Wave
Output waveform distortion Linear load≤3%
Efficiency(AC Mode) >99%
Output Voltage(AC Mode) Conforming to AC input
Output Frequency(AC Mode) Conforming to AC input
No load loss(Battery Mode) ≤1% rated power
No load loss(AC Mode) ≤2%rated power( charger does not work in AC mode)
No load loss
(Energy saving Mode)
≤10W
Phase 3 PHASE
BATTERY VRLA Battery Charge Voltage :13.8V; Float Voltage:13.7V(Single battery voltage)
Customize battery Charging and discharging parameters of different types of batteries can be customized according to user requirements
(charging and discharging parameters of different types of batteries can be set through the operation panel)
Protection Battery undervoltage alarm 11V(Single battery voltage)
Battery undervoltage protection 10.5V(Single battery voltage)
Battery overvoltage alarm 15V(Single battery voltage)
Battery overvoltage protection 17V(Single battery voltage)
Battery overvoltage recovery voltage 14.5V(Single battery voltage)
Overload power protection Automatic protection (battery mode), circuit breaker or insurance (AC mode)
Inverter output short circuit protection Automatic protection (battery mode), circuit breaker or insurance (AC mode)
Temperature protection >90°C(Shut down output)
Alarm A Normal working condition, buzzer has no alarm sound
B Buzzer sounds 4 times per second when battery failure, voltage abnormality, overload protection
C When the machine is turned on for the first time, the buzzer will prompt 5
when the machine is normal
Inside Solar controller Charging Mode MPPT or PWM
(Optional) Charging current PWM: 100A-200A / MPPT: 50A/100A
PV Input Voltage Range PWM: 480V-704V / MPPT: 480V-640V
Max PV Input Voltage(Voc) PWM: 750V / MPPT: 800V
(At the lowest temperature)
PV Array Maximum Power PWM: 44.8KW(100A)/33.6KW*2(150A)/44.8KW*2(200A)) / (MPPT: 22.4KW(50A)/22.4KW*2(100A)
Standby loss ≤3W
Maximum conversion efficiency >95%
Working Mode Battery First/AC First/Saving Energy Mode
Transfer Time ≤4ms
Display LCD
Thermal method Forced Air Cooling
Communication(Optional) RS485/APP(WIFI monitoring or GPRS monitoring)
Environment Operating temperature -10℃~40℃
Storage temperature -15℃~60℃
Noise 2000m(More than derating)
Elevation ≤65dB
Humidity 0%~95% ,No condensation

Reviews

There are no reviews yet.

Be the first to review “3 Phase Low Frequency Solar Inverter DX Series”

Your email address will not be published. Required fields are marked *

Quick Comparison

3 Phase Low Frequency Solar Inverter DX Series removeBattery Cabinet battery Rack B1-B40 (Support Customized Size) removeHigh Frequency Rack Mount UPS RTX Series removePortable Power Station PX Series 500W removePortable Power Station PS Series 2200W removeSingle Phase High Frequency Online UPS VT Series 1KVA-3KVA remove
Name3 Phase Low Frequency Solar Inverter DX Series removeBattery Cabinet battery Rack B1-B40 (Support Customized Size) removeHigh Frequency Rack Mount UPS RTX Series removePortable Power Station PX Series 500W removePortable Power Station PS Series 2200W removeSingle Phase High Frequency Online UPS VT Series 1KVA-3KVA remove
Image
SKUSF1033560130139-5SF1033560130139-9SF1033560130139-13SF1033560130139-24SF1033560130139-22SF1033560130139-25
Rating
Price

$0.00

$0.00

$0.00

$0.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad
Features:
  • The battery cabinet is made of metal material, strong and can bear up to 500KG.
  • The battery cabinet is assembled in the form of assembly, which is conven-ient for transportation and simple for assembly.
  • The surface of electrostatic spraying, strong rust resistance, color can be fixed spray.
  • Other sizes can be customized.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Features:
1)19 inches standard design of rack mount, compact structure. 2)Sin wave output provides best power supply guarantee. 3)Zero transfer time between mains mode and battery mode. 4)Detection function of input neutral wire and live wire. 5)Having voltage surge protection function and strong anti-interference function. 6)Equipped with correction function of input power factor 7) Supporting mobile smart monitoring card , users can real-time monitor every data of the UPS by mobile APP.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Features:
  • True Double conversion Technology
  • DSP digital control technology enable UPS more stable performance.
  • Three-level inverter technology
  • Active High input power factor correction technology (PFC)
  • Wide Input Voltage Frequency Range& Strong load capacity
  • Zero power switch delay
  • Compatible with Generators
  • Wide input voltage and frequency range can effectively isolate the harmful waves into power by the generator and provide pure,safe and stable power supply.
  • Support intelligent monitoring
  • Fully support remote intelligent monitoring with flexibility in choice of USB cards . AS400 cards , SNMP cards , RS485 cards
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Features:
Three Phase Hybrid Solar Inverter Off grid three phase solar hybrid inverter with pwm/mppt can be used in single-phase and three-phase ac load with total power not exceeding  100kva/120kva/125kva/150kva/160kva,384vdc to 380vac. •Pure sine wave output. •Low DC voltage, saving system cost. •Three phase solar inverter with built-in PWM or MPPT charge controller. •AC charge current 0-45A adjustable. •Wide LCD screen, clearly and precisely shows icon data. •100%imbalance loading design, 3 times peak power. •Setting different working modes based on variable usage requirements. •DC first/AC first optional. •Various communication ports and remote controls  
Specifications
MODEL DX100KVA DX120KVA DX125KVA DX150KVA DX160KVA 190KVA 200KVA
Rated Power 80KW 96KW 100KW 120KW 128KW 150KW 160KW
Peak Power(20ms) 240KVA 288KVA 300KVA 360KVA 384KVA 450KVA 480KVA
Start Motor 40HP 50HP 50HP 60HP 60HP 80HP 80HP
Battery Voltage 384VDC
Size(L*W*Hmm) 875*720*1380 1123*900*1605
Packing Size(L*W*Hmm) 980*825*1560 1185*960*1750
N.W.(kg) 512 592 612 612 642 705 755
G.W.(kg)(Wooden Packing) 552 632 652 652 692 755 805
INPUT DC Input Voltage Range 10.5VDC-15VDC(Single battery voltage)
AC Input Voltage Range 380Vac/400Vac±10%(customized 190Vac/200Vac)
AC Input Frequency Range 45Hz-55Hz(50Hz)/ 55Hz-65Hz(60Hz)
Max AC charging current 0-45A(Depending on the model)
AC charging method Three-stage (constant current, constant voltage, floating charge)
Phase 3 PHASE
OUTPUT Efficiency(Battery Mode) ≥85%
Output Voltage(Battery Mode) 380Vac/400Vac±10%(customized 190Vac/200Vac)
Output Frequency(Battery Mode) 50/60Hz ±1%
Output Wave(Battery Mode) Pure Sine Wave
Output waveform distortion Linear load≤3%
Efficiency(AC Mode) >99%
Output Voltage(AC Mode) Conforming to AC input
Output Frequency(AC Mode) Conforming to AC input
No load loss(Battery Mode) ≤1% rated power
No load loss(AC Mode) ≤2%rated power( charger does not work in AC mode)
No load loss (Energy saving Mode) ≤10W
Phase 3 PHASE
BATTERY VRLA Battery Charge Voltage :13.8V; Float Voltage:13.7V(Single battery voltage)
Customize battery Charging and discharging parameters of different types of batteries can be customized according to user requirements
(charging and discharging parameters of different types of batteries can be set through the operation panel)
Protection Battery undervoltage alarm 11V(Single battery voltage)
Battery undervoltage protection 10.5V(Single battery voltage)
Battery overvoltage alarm 15V(Single battery voltage)
Battery overvoltage protection 17V(Single battery voltage)
Battery overvoltage recovery voltage 14.5V(Single battery voltage)
Overload power protection Automatic protection (battery mode), circuit breaker or insurance (AC mode)
Inverter output short circuit protection Automatic protection (battery mode), circuit breaker or insurance (AC mode)
Temperature protection >90°C(Shut down output)
Alarm A Normal working condition, buzzer has no alarm sound
B Buzzer sounds 4 times per second when battery failure, voltage abnormality, overload protection
C When the machine is turned on for the first time, the buzzer will prompt 5 when the machine is normal
Inside Solar controller Charging Mode MPPT or PWM
(Optional) Charging current PWM: 100A-200A / MPPT: 50A/100A
PV Input Voltage Range PWM: 480V-704V / MPPT: 480V-640V
Max PV Input Voltage(Voc) PWM: 750V / MPPT: 800V
(At the lowest temperature)
PV Array Maximum Power PWM: 44.8KW(100A)/33.6KW*2(150A)/44.8KW*2(200A)) / (MPPT: 22.4KW(50A)/22.4KW*2(100A)
Standby loss ≤3W
Maximum conversion efficiency >95%
Working Mode Battery First/AC First/Saving Energy Mode
Transfer Time ≤4ms
Display LCD
Thermal method Forced Air Cooling
Communication(Optional) RS485/APP(WIFI monitoring or GPRS monitoring)
Environment Operating temperature -10℃~40℃
Storage temperature -15℃~60℃
Noise 2000m(More than derating)
Elevation ≤65dB
Humidity 0%~95% ,No condensation
Features:
  • The battery cabinet is made of metal material, strong and can bear up to 500KG.
  • The battery cabinet is assembled in the form of assembly, which is conven-ient for transportation and simple for assembly.
  • The surface of electrostatic spraying, strong rust resistance, color can be fixed spray.
  • Other sizes can be customized.
 
Technical Specifications
Model Dimensions(W*D*H) (mm) Battery Capacity Battery Numbers Weight(kg)
B-1B 280x190x220 24AH/17AH 2/3PCS 2.2
B-1 435x210x270 17AH/24AH/38AH 5/3/2 PCS 3.3
65AH/100AH 1PC
B-1A 540x210x230 17AH/24AH/38AH 6/4/3PCS 4.5
B-2 450x470x320 17AH/24AH/38AH 10/6/4 PCS 7
65AH/100AH 2PCS
B-3 585x470x320 17AH/24AH/38AH 14/8/6PCS 9
65AH/100AH 3PCS
B-4 450x470x615 17AH/24AH/38AH 20/12/8PCS 15
65AH/100AH 4PCS
B-6 585x470x615 17AH/24AH/38AH 28/16/12PCS 18
65AH/100AH 6PCS
B-8 780x470x615 17AH/24AH/38AH 44/28/20PCS 21
65AH/100AH 8PCS
B-10 950x470x615 17AH/24AH/38AH 44/28/20PCS 24
65AH/100AH 10PCS
B-12 780x470x910 24AH/38AH 30/24PCS 32
65AH/100AH 12PCS
B-16 780x470x1190 24AH/38AH 40/32PCS 45
65AH/100AH 16PCS
B-20 950x470x1190 24AH/38AH 56/40PCS 50
65AH/100AH 20PCS
B-24 1150x470x1190 65AH/100AH 24PCS 57
B-32 780x880x1190 65AH/100AH 32PCS 95
B-40 950x880x1190 65AH/100AH 40PCS 100
Features:
1)19 inches standard design of rack mount, compact structure. 2)Sin wave output provides best power supply guarantee. 3)Zero transfer time between mains mode and battery mode. 4)Detection function of input neutral wire and live wire. 5)Having voltage surge protection function and strong anti-interference function. 6)Equipped with correction function of input power factor 7) Supporting mobile smart monitoring card , users can real-time monitor every data of the UPS by mobile APP.  
Technical Specifications
Model RTX3110KL RTX3115KL RTX3120KL
Rated Power 10kVA/9kW 15kVA/13.5kW 20kVA/18kW
INPUT Voltage Range 207-475Vac3P4W+G
Working Frequency Range 40-70HZ (settable)
Input Power Factor >0.95
OUTPUT Rated Voltage and Accuracy 220Vac(l±l%)lP2W+G
Output Frequency 46-54Hz synchronize with mains power; 50Hz (Mains power between 40-46Hz and 54-60Hz); 50Hz(Battery)
Rated Current 45A 68A 91A
Output Power Factor 0.9
Output Harmonic Wave W3%
Crest Factor  3:1
Output Overload 105%±5%<Load≤125%±5%: Convert to bypass output and alarm after 1 min; 125%±5%<Load ≤50%±5%: Convert to bypass output and alarm after 30s; Load>150%±5%: Convert to bypass output and alarm after 300ms.
Transfer Time 0ms
Efficiency >92%
BATTERY Rated Voltage 192Vdc
Quantity 16
Charging Current 5.5A
Dimension (LxWxH) mm 665*482.6*132.5 655*482.6*265
Weight 23kg 34kg 35kg
Working Temperature 0°〜40°C
Working Humidity 20% 〜95%
Noise ≤60dB
Features:
  • Rated Power: 500W
  • Rated Capacity: 519 . 48wh
  • Standard Capacity: 3.7V/140400mah
  • Overload Protecion: 550W + 40W
  • AC Output: AC 110V+10%/60HZ 230V+10%/50HZ
  • Output Wave: Pure sine wave
  • USB Output: QC 18W*2
  • Type-c Output: PD 60W*2
  • Cigarret Lighter Output: 14V/8A
  • DC5525 Output: 14V/8A
  • Wireless Charging: 15W
  • Charging Input: 12-26 V/100W Max
  • WorkingTemperature: -10-40 °C
  • Weight(Net Weight): 6.8kg
  • Weight(With Accessories): 8.5kg
  • Dimension: 345*227*203mm
 
Applications:
  • Mammogram
  • Ultrasound Equipments
  • Radiology rooms
Features:
  • Capacity: 2200W 2048Wh /640000mAh
  • Input AC Output Power:Rated Power 2400W Peak Power 4800W
  • Input AC Charging:AC100~125V/AC174~264V Bidirectional Inverter 1400W Max
  • Input Car Charging:DC12V~24V/10A 240W Max
  • Input Solar Charging:DC16V~60V/10A 500W Max
  • Output Voltage:230VAC±10%/110VAC±10%
  • Output Frequency: 50Hz±5%/60Hz±5%
  • USB Output:2*QC18W+PD27W+PD100W Max
  • DC Output:1*Cigarette Lighter 12.8V/12A Max+2*DC5521 Rated Output 12.8V/5A Max
  • Output Waveform:Pure Sine Wave
  • LED:3 Levels(H/M/L)+SOS
  • UPS Function:Support ; Battery Expandable: Support
 
Applications:
  • Mammogram
  • Ultrasound Equipments
  • Radiology rooms
Features:
  • True Double conversion Technology
  • DSP digital control technology enable UPS more stable performance.
  • Three-level inverter technology
  • Active High input power factor correction technology (PFC)
  • Wide Input Voltage Frequency Range& Strong load capacity
  • Zero power switch delay
  • Compatible with Generators
  • Wide input voltage and frequency range can effectively isolate the harmful waves into power by the generator and provide pure,safe and stable power supply.
  • Support intelligent monitoring
  • Fully support remote intelligent monitoring with flexibility in choice of USB cards . AS400 cards , SNMP cards , RS485 cards
Applications:
  • Mammogram
  • Ultrasound Equipments
  • Radiology rooms
 
Technical Specifications
Model VT1K VT1KL VT2K VT2KL VT3K VT3KL
Rated power 1KVA/900KW 2KVA/1.8KW 3KVA/2.7KW
Input Voltage range 90~285Vac L+N+G
Frequency range 40-70Hz(Adjustable)
Input power factor >0.99
Output Rated voltage and precision 220Vac (1±2% ) L+N+G
Output frequency 46-54Hz Synchronous mains power; 50Hz( Frequency Range 40-46Hz ~54-60Hz);50Hz(Battery mode)
Rated Current 4.5A 9.1A 13.6A
Output power factor 0.9
Output harmonic ≤4%
Crest factor 3:1
Inverter overload capacity 105%±5%< Load<125%±5% : 50s transfer to bypass 125% ±5% < Load<150 % ±5 % : 25s transfer to bypass Load > 150 % ± 5 %: 300s transfer to bypass
Transfer time 0ms
Efficiency ≥85%
Battery Rated voltage 24Vdc 36Vdc 48Vdc 72Vdc 72Vdc 96Vdc
Battery Numbers 2 3 4 6 6 8
Charge current 1A 6.5A 1A 5.5A 1A 5.5A
Size(LXWXH)mm 350*144*230 425*190*328
Net Weight(KG) 9.5kg 6kg 18.5kg 10kg 23.5kg 11kg
Operating temperature 0°C 〜40°C
Operating humidity 20% 〜95%
Noise ≤50dB
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare