Description | Shipped From Abroad
Mechanical round dial weighing scale | ADE M306800
Easy to use always ready to work personal scale. The large and clear dial shows the weight fast and accurate without the need of any electric power. As a standard feature a telescopic height measuring rod is attached to the column of the scale.
Delivery & Availability:
Typically 14-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped from abroad
The high-acuity Neurofax EEG system is extremely intuitive. Its user-friendly software features a wide range of functions including record, playback, and quantitative data analysis. As a standard examination in neurology, electroencephalography is used in many scenarios – from routine diagnostics to critically ill patients, or neuromonitoring in the ICU. The Neurofax EEG system is built to cover all aspects of diagnostics, delivering innovative functionality, high signal quality, and durability to ensure efficiency – all while remaining simple to use.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
Needle destruction destroy the needle immediately following its use. Needle destruction are an absolute necessity in developing parts of the world to prevent the reuse of needles and the spread of bloodborne pathogens. They are NOT a good alternative, however, for hospital use in the developed parts of the world. Needle destruction are products that bend, cut, or destroy the needle. This are distinctly different from needle destroyer that send an arc of electricity to vaporize and melt the needle.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
- Supplied with one 35 cms. dia. S.S. Basin.
- Stainless steel pipe construction mounted on three 10 cms. dia. castors.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
Used for Clinical Diagnostics.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
Material Stainless: Steel
Height Adjustable: Yes
Number of Wheel: 4
Height: 3-4 Feet
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. |
Content |
ADE M306800 Mechanical scale
Description
-
- Easy to use
- Large and clear dial
- No need of any electric power
- Telescopic height measuring rod is attached to the column of the scale
- Manual zero setting
- Height measuring
Technical Data
Round dial weighing scale: |
Capacity |
150 kg |
Graduation |
500 g |
Units |
kg, kg/lbs |
Dimensions weighing platform |
270 x 370 mm |
Dimensions overall |
280 x 665 x 1085 mm |
Weight |
13.5 kg |
Telescopic height measuring rod: |
Length measuring range |
600 – 2100 mm |
Graduation |
1 mm |
| The high-acuity Neurofax EEG system is extremely intuitive. Its user-friendly software features a wide range of functions including record, playback, and quantitative data analysis. As a standard examination in neurology, electroencephalography is used in many scenarios – from routine diagnostics to critically ill patients, or neuromonitoring in the ICU. The Neurofax EEG system is built to cover all aspects of diagnostics, delivering innovative functionality, high signal quality, and durability to ensure efficiency – all while remaining simple to use.
Features:
- Polaris.com, a powerful data management system, supports the straightforward administration and organization of diagnostic data. Modern communication interfaces (HL7 and GDT/BDT) enable integration into hospital and practice information systems.
- Digital Video Software allows synchronized digital video for EEG systems using webcam, professional HD camera, or picture-in-picture as per requirements.
- EEG Mapping, offers amplitude with spectral and frequency online mapping during acquisition, even with single channels and montages.
- Spike and Seizure Detection Software with a high sensitivity and a stunningly low false positive rate.
- Polysmith* combines sleep analysis software with recording devices to provide quick and precise data analysis – for a complete PSG solution customized to individual needs.
- EEG Trend Program converts EEG signals into clear trend graphs making them easy to interpret (aEEG, DSA, CSA, Power FFT).
- Smart vital signs interface for holistic multimodality assessment of patient, with capability to pull up 8 channels from bedside monitors
- Live View Panel offers intuitive real-time management of diverse neuromonitoring data from a centralized location.
- Amplifier: high-quality amplifier with 38 to 256 channels realizes wide-band EEG recording from slow shift to fast ripple.
- Brain function mapping system: a comprehensive and sophisticated system for brain function mapping reduces timeconsuming procedures by combining cortical stimulation, easy switch between stimulation and recording, and a brain function mapping report all in one place.
- EEG scope: data reviewer that allows review of previous EEG while monitoring, acquiring, and opening up to 4 EEGs at the same time.
- 3D voltage mapping: whole head maps offer a complete overview and better interpretation of the topography of EEG abnormalities.
- Customizable Main Menu that allows registration of examination protocol buttons on the main menu. Each button has user-defined settings for an examination which can be adjusted for different examination conditions and methods
- Note Window offers to save up to 1,000 sections of waveforms for comparison by dragging and dropping. Up to 100 copied waveforms can be registered as sample data for comparison with other patients or teaching purposes.
- NeuroReport, which is integrated in all Nihon Kohden EEG systems, offers individually configured report templates, including adaptive auto text functions, for fast and simple reporting. It guarantees maximum flexibility and compatibility.
Technical Specifications:
Routine EEG composition:
Electroencephalograph: EEG-1200J/K
PC unit: CC-120AJ/AK
Electrode junction box: JE-921A
Flash lamp assembly: LS-703A
Photic stimulator control unit: LS-120AJ/AK
Cart: KE-122A
Stand: KC-001A
LCD display: Local purchase
EMU Composition:
Electroencephalograph: EEG-1200J/K
PC unit: CC-120AJ/AK
256 channel electrode junction box: JE-120A-256
Input box converter: QI-123A
Mini flat junction box: JE-125AK
Mini flat junction box: JE-226AK
Mini flat junction box: JE-227AK
Mini flat junction box: JE-228AK
Flash lamp assembly: LS-703A
Photic stimulator control unit: LS-120AJ/AK
Cart with printer table: KD-029A
Stand: KC-001A
LCD display: Local purchase
Extension unit: MS-120BK
Switch box: PE-210AK
Model Suffixes
EEG-1200 has the following suffixies:
J: 110-127 V AC operation
K: 220-240 V AC operation
| Needle destruction destroys the needle immediately following its use. Needle destruction are an absolute necessity in developing parts of the world to prevent the reuse of needles and the spread of bloodborne pathogens. They are NOT a good alternative, however, for hospital use in the developed parts of the world. Needle destruction are products that bend, cut, or destroy the needle. This are distinctly different from needle destroyer that send an arc of electricity to vaporize and melt the needle.
Features:
- Well built
- Easy to maintain
- Having a rubbish drawer with alarm function, this is our most popular model of Syringe Destroyer for use in labs, pharma, universities and doctors clinics
- With its low factory-direct price and excellent quality, its a great addition to add to any medical industry or university office that wants to ensure the safety and legal compliance of its operations
Specifications:
- Short Name: Needle destruction / Needle Destroyer
- Working Noise: ≤50 decibel
- Superheating Sanitization Temperature: 95 deg C
- Working Time: Can completely melt and destroy needle and neck of syringe in 5 seconds
- Working Noise: ≤50 decibel
- Dimensions: Approx. 38cm x 29cm x 28cm
- Power: AC 110V or 220V
|
- Supplied with one 35 cms. dia. S.S. Basin.
- Stainless steel pipe construction mounted on three 10 cms. dia. castors.
| Used for Clinical Diagnostics.
- Test Method: Dry Strip color-developing method
- Test Principle: Dual wavelength reflectance photometry
- Light Source: Cold Lamp with high brightness and long lifetime
- Test System: Color-indentify system with high sensitivity and repeatability
- Wavelength: 520nm, 640nm, 660nm
- Throughput: 120 Strips/Hour
- Test Mode: Single and continuous test mode are selectable
- Test Slot: Using sliding Slot, Easy to clean and replace, lower the carryover
- Waste Collection: Waste urine and waste strips can be collected automatically
- Test Strip: Use GENIUS original strips only
- Display: LCD with high brightness and resolution
- Language: Customizable language software
- Memory: Save 2000 samples results, and auto recover the results when power off during working
- Interface: RS-232 serial port, can be connected to external printer and computer Printer: Inner thermal printer, can be connected to external printer
- Report format: Half quantitative and qualitative, report the color and turbidity is available
- Result unit: SI unit and routine unit are selectable
- Status Check: Auto-check the status during power on and off, auto-indentify the alarm
- Working Environment: Temperature10℃~30℃; Humidity: 20%RH~80%RH
- Power: 100-240V, Auto adapt according to the input voltage
- Consumption: ≤80VA
- Quality System: Certified by TUV and CMD
|
Material |
Stainless Steel |
Height Adjustable |
Yes |
Number of Wheel |
4 |
Height |
3-4 Feet |
|
Reviews
There are no reviews yet.