Airway balloon dilatation catheter
$0.00
Shipped From Abroad
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
Features:
- The elastic soft head design allows smooth entry into the target area with minimal damage to tissues;
- The balloon is highly transparent, which is convenient for observing the expansion process;
- The balloon is made of imported materials, has high pressure resistance, is not easy to deform, and is safer to expand;
- The balloon adopts multi-wing folding, constant temperature shaping, good resilience, and easy to withdraw from the working channel;
- The optimized catheter has smooth wall, good elasticity, strong anti-kink resistance and good pushing performance;
- The balloon is installed with a developing mark that is clearly visible under X-ray and accurately positioned.
It is compatible with various domestic and imported endoscopes and can replace similar imported products
Specification Sheet:
Model Specifications | Balloon
diameter D (mm) |
Balloon
length L (mm) |
Balloon working pressure (atm) | Balloon
Withstand voltage (atm) |
Applicable clamp hole diameter
Code & Adapter Guide Wire |
Work
Length L1 (mm) |
PB- 00 (20, 22, 28) SK (A, C, D, E, K, N) – 04 ( 06 , 08 , 10 , 12 , 14 , 16 , 18 , 20 ) 30 (40, 50, 55, 60, 80) | 04 | 30,40
50,55 |
8 | 10 | 00: Not applicable to any clamp hole & guide wire adapter: ≤0.035″ (0.8 8 mm)
2 0 : Applicable to ≥2. 0 mm clamp hole diameter & suitable guide wire: ≤0.03 2 ″ (0.8 0 mm) 22 : Applicable to ≥2.2 mm clamp hole diameter & suitable guide wire: ≤0.032 ″ (0.80 mm ) 28: Applicable to ≥2.8mm clamp hole diameter & suitable guide wire: ≤0.035″ (0.8 8 mm) |
SK:600
A : 900 C :1050 D:1100 E :1200 K :1600 N :1800 |
06 | 8 | 10 | ||||
08 | 8 | 10 | ||||
10 | 8 | 10 | ||||
12 | 40,50
55,60 80 |
5 | 6 | |||
14 | 5 | 6 | ||||
16 | 5 | 6 | ||||
18 | 50,55
60,80 |
4 | 5 | 00: Not applicable to any clamp hole & guide wire adapter: ≤0.035″ (0.8 8 mm)
28: Applicable to ≥2.8mm clamp hole diameter & suitable guide wire: ≤0.035″ (0.8 8 mm) |
||
20 | 4 | 5 |
Quick Comparison
Airway balloon dilatation catheter remove | Plastic Forceps remove | Disposable Medical Razor Blade remove | Dialysis Dressing Kit remove | Suction Liner Type E remove | HR Lubricating Jelly 5g OneShot remove | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Name | Airway balloon dilatation catheter remove | Plastic Forceps remove | Disposable Medical Razor Blade remove | Dialysis Dressing Kit remove | Suction Liner Type E remove | HR Lubricating Jelly 5g OneShot remove | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
SKU | SF1033560130153-8 | SF1033560130113-1 | SF1033560130102-147 | SF1033560130104-30 | SF1033560130111-3 | SF1033560130149-5 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Rating | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Price |
|
|
|
|
|
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Stock | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Availability | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Add to cart | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Description | Shipped From Abroad
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
This product is mainly composed of drape, tape, cotton roll, band-aid, povidone-iodine swab, latex gloves and tray. (Can be customized according to clinical needs).
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
HR Lubricating Jelly 5g OneShot is a sterile, single-use product designed to improve application, minimize waste, and significantly reduce the risk of cross-contamination.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Content | Features:
Specification Sheet:
| Features Blade: high quality single or double stainless steel blade, twain coated material, the blade is very sharp and durable. Main Function: • Shaving hairs off any length and density before operation. • Shaving hairs off any length and density daily for men and Women. Different colors available. | Product Description This product is mainly composed of drape, tape, cotton roll, band-aid, povidone-iodine swab, latex gloves and tray. (Can be customized according to clinical needs).Product Performance A. Disposable use to avoid iatrogenic infection; B. Sterile products; C. Integral sterilization, ready for use, safe and convenient for use; D. Compliance with the regulation of “strictly implement aseptic operation procedures, venous blood collection must be one person, one needle, one tube, one towel and one belt” as required by the Ministry of Health in Hospital Infection Management Regulations.Product Usage Postoperative daily care of dialysis patients in the hospital.Precautions 1. This product is sterilized by ethylene oxide and is safe and convenient to use; 2. The sterilization period of this product is limited to two years. If the package is damaged, it is forbidden to use; 3. For the production date and batch number, see the spray code; 4. This product is for single use, and it shall be destroyed in a centralized manner after use. Repeated use is strictly prohibited.Qichuang Nursing Kit Products
| Description
E Type
Model: YDE
Classic design, large suction flow, currently used in most hospitals. Special filter design assure the stop line accurate,and with more than 50ml tube liquid reflux extra space, will not cause splash phenomenon.
All bags can be used individually or in a serial connection and accommodate all accessories for special clinical needs.
#Suction bags without solidifying agent & filter are the basic type for general use.
#Suction bags with solidifying agent are used to solidify the collection of the waste fluid. The waste fluid can be solidified, sterilized and deodorant immediately.
#Suction bags with filter enable more hygiene operation as the valve prevents liquid spillage from the patient port before it is plugged.
Specification: 1000ml, 1500ml, 2000ml, 3000ml | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Weight | N/A | N/A | N/A | N/A | N/A | N/A | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Dimensions | N/A | N/A | N/A | N/A | N/A | N/A | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Additional information |
Reviews
There are no reviews yet.