Features:
- The elastic soft head design allows smooth entry into the target area with minimal damage to tissues;
- The balloon is highly transparent, which is convenient for observing the expansion process;
- The balloon is made of imported materials, has high pressure resistance, is not easy to deform, and is safer to expand;
- The balloon adopts multi-wing folding, constant temperature shaping, good resilience, and easy to withdraw from the working channel;
- The optimized catheter has smooth wall, good elasticity, strong anti-kink resistance and good pushing performance;
- The balloon is installed with a developing mark that is clearly visible under X-ray and accurately positioned.
Specification Sheet:
Model Specifications |
Balloon
Diameter D (mm) |
Balloon
Length L (mm) |
Balloon working pressure |
Applicable clamp hole diameter code & compatible guide wire |
Working length L1 (mm) |
use |
|
Mpa | atm | ||||||
BD-00 (20, 28, 32)
SK (A, C, D, E, K, N, P, Q, T, U, W, LK) – 04 (05, 06, 08, 10, 12, 14, 16, 18, 20, 25, 30, 35, 40) – 8 (10, 12, 15, 20, 25, 30, 35, 40, 45, 50, 55, 60, 80, 100, 150) |
04 | 8
10 12 15 20 25 30 35 40 45 50 55 60 80 100 150 |
0.8 | 8 | 00: Not applicable to any clamp hole & suitable for guide wire ≤ 0.035″;
20: Applicable to the clamp hole diameter ≥2.0mm & suitable for guide wire ≤0.032″;
28: Applicable to the clamp hole diameter ≥2.8mm & suitable for guide wire ≤0.035″;
32: Suitable for clamp hole diameter ≥3.2mm & suitable for guide wire ≤0.035″. |
SK: 600
A: 900 C: 1050 D: 1100 E: 1200 K: 1600 N: 1800 P: 1900 Q: 2000 T: 2200 U: 2300 W: 2500 LK: 2600 |
Esophageal/pyloric/intestinal balloon
Common models are balloon diameter (mm): 06, 08, 10, 12, 14, 16, 18, 20 Balloon length (mm): 40, 60, 80 Catheter length (mm): 1800, 2300 |
05 | 0.8 | 8 | |||||
06 | 0.8 | 8 | |||||
08 | 0.8 | 8 | Cardiac dilation balloon
Common models are balloon diameter (mm): 25, 30, 35 Balloon length (mm): 80 Catheter length (mm): 900 |
||||
10 | 0.8 | 8 | |||||
12 | 0.5 | 5 | |||||
14 | 0.5 | 5 | ERCP dilatation balloon
Common models are balloon diameter (mm): 06, 08, 10, 12, 14 Balloon length (mm): 40, 60 Catheter length (mm): 2000 |
||||
16 | 0.5 | 5 | |||||
18 | 0.4 | 4 | |||||
20 | 0.4 | 4 | Percutaneous choledochoscopy dilatation balloon
Commonly used models are balloon diameter (mm): 06, 08 Balloon length (mm): 40 Catheter length (mm): 900, 1800
|
||||
25 | 0.2 | 2 | |||||
30 | 0.2 | 2 | |||||
35 | 0.2 | 2 | Commonly used balloon diameters for duodenal dilatation: 20, 25 mm
Common diameters of the duodenal nipples: 10, 12, 14 mm |
Quick Comparison
Balloon dilatation catheter remove | Disposable Surgical Blades remove | Suction Liner Type A remove | PICC/CVC Catheter Fixation Device remove | HR Lubricating Jelly OneShot Safe Wrap™ - STERILE remove | HR Lubricating Jelly OneShot remove | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Name | Balloon dilatation catheter remove | Disposable Surgical Blades remove | Suction Liner Type A remove | PICC/CVC Catheter Fixation Device remove | HR Lubricating Jelly OneShot Safe Wrap™ - STERILE remove | HR Lubricating Jelly OneShot remove | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
SKU | SF1033560130153-21 | SF1033560130102-148 | SF1033560130111-1 | SF1033560130104-33 | SF1033560130149-7 | SF1033560130149-6 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Rating | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Price |
|
|
|
|
|
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Stock | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Availability | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Add to cart | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Description | Shipped From Abroad
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Packing: foil pack, 100pcs/ box, 5000pcs/ctn.
Size:10#, 10A#, 11#, 12#, 12B#, 13#, 14#, 15#, 15C#, 16#, 18#, 19#, 20#, 21#, 22#, 23#, 24#, 25#, 36#
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
PICC catheter fixation device is composed of non-woven PU film, medical polymer coated medical pressure-sensitive adhesive and release material; used for the fixation of indwelling needle and the fixation of intravenous injection catheter or drainage tube.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
HR’s SafeWrap™ packaging takes our OneShot offering and makes it operating room and sterile-field friendly. This product is our original HR Lubricating Jelly 1.25 oz.OneShot packaged in a STERILE SafeWrap™ sleeve.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
HR Lubricating Jelly 1.25 oz. OneShot is a sterile single-use alternative to our 2 oz. Flip-Top Tube. Research has shown that 2 oz. the tube is too much volume for some procedures. The 1.25 oz. OneShot® reduces waste and the risk of cross-contamination.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Content | Features:
Specification Sheet:
| Features:A Type
Model: YDA Bag with wide mouth design, large taper, and cover with a lifting ring, easy to take from the canister. Special filter design assure the stop line accurate,and with more than 50ml tube liquid reflux extra space, will not cause splash phenomenon. All bags can be used individually or in a serial connection and accommodate all accessories for special clinical needs. #Suction bags without solidifying agent & filter are the basic type for general use. #Suction bags with solidifying agent are used to solidify the collection of the waste fluid. The waste fluid can be solidified, sterilized and deodorant immediately. #Suction bags with filter enable more hygiene operation as the valve prevents liquid spillage from the patient port before it is plugged.Specification: 2000ml, 3500ml | Product details PICC catheter fixation device is composed of non-woven PU film, medical polymer coated medical pressure-sensitive adhesive and release material; used for the fixation of indwelling needle and the fixation of intravenous injection catheter or drainage tube.Scope of use Used for fixation of PICC catheter, fixation of indwelling needle, fixation of central venous catheter or drainage tube and other suitable catheters.Instructions 1. Take out the product from the packaging bag after cleaning and sterilizing the puncture site. 2. Remove the release paper from the side of the slit to expose the glue surface. 3. Put the adhesive surface to the skin and smooth it from the middle to all around. 4. Fixed catheter.Precautions to take during the use of catheter fixing device 1. Single use. 2. Single use and Please don’t use once the pouch is torn. 3. Cannot instead of the suture, hemostasis, skin disinfection and other measures. 4. Cannot be used for the fixation of arterial duct.Product specification
|
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Weight | N/A | N/A | N/A | N/A | N/A | N/A | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Dimensions | N/A | N/A | N/A | N/A | N/A | N/A | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Additional information |
Reviews
There are no reviews yet.