New

Bipolar Irrigated Coagulator

$0.00

Shipped From Abroad

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Brand:
Brands:: OBS

Description

Features

1. LED light positioned between the electrodes enhances the vision during surgery.

2. Massive area hemostasis can be performed in a short time in order to reduce intraoperative blood loss

3. Saline line and dripping device are equipped in an attempt to contain the heat on the treated tissue and avoid thermal tissue damage

Indications for Use
  • Ensure that both electrodes are in contact with the tissue to be treated. Activation and saline flow occur simultaneously.
  • Ensure that saline is flowing at the time of activation
  • These devices should never be used when:
  • There is visible evidence of damage to the exterior of the device such as cracked or damaged plastic or connector damage.
  • These devices fail the inspection described herein.
  • In the presence of flammable gases, flammable prep solutions or drapes. Oxidizing. Gases such as Nitrous Oxide (N2O), or in oxygen-riched environments.
  • Do not use monopolar electrosurgery on small appendages, as in circumcision or finger surgery.

Reviews

There are no reviews yet.

Be the first to review “Bipolar Irrigated Coagulator”

Your email address will not be published. Required fields are marked *

Quick Comparison

Bipolar Irrigated Coagulator removeReusable Electrosurgical Pencil removeOBS-50 High Frequency Coagulator removeDisposable Skin Stapler removeOBS-100A Monopolar Electrosurgical Unit removeOBS-100C LCD Version Dual cold RF Electrosurgical Unit remove
NameBipolar Irrigated Coagulator removeReusable Electrosurgical Pencil removeOBS-50 High Frequency Coagulator removeDisposable Skin Stapler removeOBS-100A Monopolar Electrosurgical Unit removeOBS-100C LCD Version Dual cold RF Electrosurgical Unit remove
Image
SKU
Rating
Price

$0.00

$0.00

$0.00

$0.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad This unit is widely used in many different sectors including plastic surgery, dermatology, ENT, Ophthalmology, somatology, gynecology, proctology, and urology.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Sterile Disposable Skin Stapler is a disposable equipment that applies to skin sutures during general surgical operation, Cardiothoracic Surgery, plastic surgery, neurosurgery operation, gynecologic surgery, burn surgery, emergency operation, and field rescue. It can be used in operating room, delivery room, emergency department, outpatient surgery, and clinics.Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad Unique dual radio frequency design. Combines 4Mhz and 1.7Mhz into one generator. Realizes the best operation result effectively. Suitable for  Plastic, Dermatology, ENT, Ophthalmology, Dentistry, Podiatry and Spinal surgery
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Features

1. LED light positioned between the electrodes enhances the vision during surgery.

2. Massive area hemostasis can be performed in a short time in order to reduce intraoperative blood loss 3. Saline line and dripping device are equipped in an attempt to contain the heat on the treated tissue and avoid thermal tissue damage
Indications for Use
  • Ensure that both electrodes are in contact with the tissue to be treated. Activation and saline flow occur simultaneously.
  • Ensure that saline is flowing at the time of activation
  • These devices should never be used when:
  • There is visible evidence of damage to the exterior of the device such as cracked or damaged plastic or connector damage.
  • These devices fail the inspection described herein.
  • In the presence of flammable gases, flammable prep solutions or drapes. Oxidizing. Gases such as Nitrous Oxide (N2O), or in oxygen-riched environments.
  • Do not use monopolar electrosurgery on small appendages, as in circumcision or finger surgery.
Features
  • High-quality tried-and-tested materials guarantee a long service life for OBS reusable electrosurgical pencils.
  • Material is durable for high temperature and high press disinfection for more than 30 times.
  • Cost compared to disposable instruments
  • The initial cost of the reusable electrosurgical pencil is easily recouped after only a fraction of the expected number of uses and compares favorably to the cost of disposable pencils.
  The OBS-50 is a market leader across the world due to its ease of use, high security, power on self test, full-range monitoring, remote control and precise output.
  • Power output can be controlled by the easy to use power adjustment button on the electrosurgical hand pencil which can shorten the operation time.
  • With the inbuilt memory function on the device, you can set the required function parameters then power off the unit, next time the unit is powered on, the unit the last set parameter will be displayed.
  • Output power of between 10 and 30 watts or less can be adjusted up and down by 0.1-watt increments, which is suitable for various delicate procedures.
  • It can be used with disposable dispersive electrode
 What's in the box?
  • x1 OBS-50 High-Frequency Electric Coagulator Unit
  • x1 Reusable power control electrosurgical pencil
  • x10 Non-Sterile Single-Use Short Sharp Tips
  • x10 Non-Sterile Single-Use Short Blunt Tips
  • x1 Power cord
  • x1 Instruction manual
Multiple Applications to meet your different clinic demands
Desiccation 
  • Monopolar output mode without using the dispersive electrode
  • Contact or insert into the tissue with the electrode
  • The unit produces a high-frequency current, which runs through the patient via the electrode and then returns to the unit through grounding.
  • High-frequency current vaporises the liquid inside the tissue cell therefore causing denaturation on the protein
Fulguration
  • Another monopoly output mode without using a dispersive electrode
  • Holding the electrode above the lesions rather than contact directly, will release an electric arc to the tissue.
  • Range of action in this mode is limited to the surface where the arc contacts the tissue
Coagulation
  • Suitable for hemostasis and shrinkage of tissue
  • Used in control of hemostasis
  • Suitable for more difficult cutting procedures for good hemostasis
Monopolar coagulation
  • Monopolar output mode using the dispersive electrode
  • Under this mode, the high-frequency current that is produced from the unit flows through the patient and then returns to the unit via a dispersive electrode
  • The dispense electrode can draw more high-frequency current to the electrode, making the tip of electrode produce a more powerful desiccation to the tissue.
Bipolar Coagulation
  • An Output mode in which the high-frequency current circulates between two nearby electrodes (bipolar forceps), without using the dispersive electrode.
  • In contrast to the effect of monopolar coagulation, since the high-frequency current is only circulated separately in the forceps, the bipolar coagulation effect acts only on the tissue surface, causing minimal damage to the tissue.
Standard Accessories (Can be purchased Separately)
  • Single foot switch
  • Reusable power control electrosurgical pencil
  • Reusable dispersive electrode (Patient Plate) & Cable
  • Reusable bipolar forceps & cable
  • Reusable Connecting Cable (for disposable dispersive electrode)
  • Disposable dispersive electrodes
  • Wall mounting Plate
Output Mode  Monopolar coagulation: (30W, load:1000Ω) Bipolar coagulation: (30W, load:200Ω) Technical parameters
Ambient Temperature  10°C - 40°C
RH Range ≤80%
atmospheric pressure range 50.0kPa-106.0kPa
Power supply 220/110V,50/60Hz
operating Frequency 550kHz+10%
Features
  • Concise and reasonable design, which is easy and convenient to operate.
  • Safe and efficient for surgery, and the needle could be withdrawn fluently and accurately.
  • Smooth and beautiful suture, small and micro healing scar.
  • There's good compatibility with tissues and less inflammatory response.
  • It's easy and convenient to take out the stitches, which will promote wound healing.
  • Sterile Disposable Skin Stapler reduces the patient's pain and improves operation efficiency.
 
Features

1. Portable and  affordable

2. Suitable for general surgery and veterinary
Technical Details
Environmental temperature range: 5°C~ 40°C
Relative moisture range: ≤80%
Atmosphere pressure range: 86.0 Kpa ~ 106.0 Kpa
Working modes:
Pure cut: 5w ~ 100w (Load:300Ω)
Blend cut: 5w ~ 50w (Load:300Ω)
Forced coagulation: 5w ~ 80w (Load:500Ω)
Soft coagulation: 5w ~ 50w (Load:500Ω)
Technology data:
Voltage: 230V±10V, 50Hz
Working frequency: 330KHz ~ 460KHz
Leakage currents to ground: Less than 0.5mA
Leakage currents to patient: Less than 0.01mA
Features
  • Clinic result proves that higher frequency can get less tissue resists nee. 4Mhz frequency can reduces heat injury a ind carbonizing to tissue at maximum. It realizes low temperature cutting.
  • The antenna pad is unnecessary for skin touch, no current goes through the body, and no possibility of burning
  • No pressure cutting and the pencil is operated easily and it's full of flexibility.
  • No carbonation, less bleeding, and no adhesions.
  • Less pain, scarring, and fast healing after operation.
Technical Parameters
Image
Product Details
OUTPUT MODE 
  • CUT - For micro-smooth cutting
  • BLEND - For cutting with coagulation
  • HEMO - For pure Hemostasis-Coagulation to control most forms of bleeding
  • FULGURATION - For desiccation or fulgurate spark-gap
  • BIPOLAR - For precise coagulation utilizing bipolar energy
INTENDED USE
  • Cutting: snoring, submucosal palatal shrinkage, traditional uvulopalatoplasty (RAUP), myringotomy with effective hemorrhage control, epistaxis treatment, turbinate shrinkage, skin incisions, biopsy, cysts, abscesses, tumors, cosmetic repairs, development of skin flaps, skin tags and blepharoplasty.
  • Blended (cutting and coagulation): snoring, submucosal palatal shrinkage, traditional uvulopalatoplasty (RAUP), myringotomy with effective hemorrhage control, epistaxis treatment, turbinate shrinkage, skin tags, papilloma keloids, keratosis, verrucae. basal cell carcinoma, nevi, fistulas, epithelioma, cosmetic repairs, cysts, abscesses, and development of skin flaps.
  • Hemostasis: control of bleeding, epilation, telangiectasia.
  • Fulguration: basal cell carcinoma, papilloma, cyst destruction, tumors, verrucae, hemostasis.
  • Bipolar: pinpoint precise coagulation, pinpoint hemostasis in any field (wet or dry), snoring, submucosal palatal shrinkage, traditional uvulopalatoplasty (RAUP), myringotomy with effective hemorrhage control, epistaxis treatment and turbinate shrinkage.
Transportation Data :
  • WxHxD:34(L)'23.5(W)*10.6(H) 49(L)*35.5(W)'31(H)cn Weight:8.2kg(NetWeight);12. cm(Generator) i(outer carton) 1kg(Gross Weight)
  • Standard Matching Accessories
  • Instruction for Use: 1pc
  • Power Cord: 1pc
  • Dual Pedal Switch: 1pc
  • Disposable ESU Pencil: 2 pes
  • Reusable Antenna Pad with cable: 1 set
  • Reusable Bipolar Forceps with Cable: 1 set
  • Reusable ESU pencil: 1 pc
  • Reusable Fine Electrode tips (Needle, curved, Needle .Ball): 7pcs
  • Disposable leep Electrode tips: 5pcs
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare