Bipolar Irrigated Coagulator
$0.00
Shipped From Abroad
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
Features
1. LED light positioned between the electrodes enhances the vision during surgery.
2. Massive area hemostasis can be performed in a short time in order to reduce intraoperative blood loss
3. Saline line and dripping device are equipped in an attempt to contain the heat on the treated tissue and avoid thermal tissue damage
Indications for Use
- Ensure that both electrodes are in contact with the tissue to be treated. Activation and saline flow occur simultaneously.
- Ensure that saline is flowing at the time of activation
- These devices should never be used when:
- There is visible evidence of damage to the exterior of the device such as cracked or damaged plastic or connector damage.
- These devices fail the inspection described herein.
- In the presence of flammable gases, flammable prep solutions or drapes. Oxidizing. Gases such as Nitrous Oxide (N2O), or in oxygen-riched environments.
- Do not use monopolar electrosurgery on small appendages, as in circumcision or finger surgery.
Quick Comparison
Bipolar Irrigated Coagulator remove | Electrotherapy Electrode remove | Electrotherapy Electrode with Cables remove | Disposable Subdermal Needle Electrodes remove | Electrosurgical Pad remove | OBS-50 High Frequency Coagulator remove | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Name | Bipolar Irrigated Coagulator remove | Electrotherapy Electrode remove | Electrotherapy Electrode with Cables remove | Disposable Subdermal Needle Electrodes remove | Electrosurgical Pad remove | OBS-50 High Frequency Coagulator remove | ||||||||||
Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ||||||||||
SKU | SF1033560130165-12 | SF1033560130165-22 | SF1033560130165-23 | SF1033560130165-25 | SF1033560130165-16 | SF1033560130165-3 | ||||||||||
Rating | ||||||||||||||||
Price |
|
|
|
|
|
| ||||||||||
Stock | ||||||||||||||||
Availability | ||||||||||||||||
Add to cart | ||||||||||||||||
Description | Shipped From Abroad
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Electrotherapy electrodes are an essential component of electrotherapy treatments, which use electrical currents to manage pain, improve circulation, repair tissues, and strengthen muscles. These electrodes are typically adhesive pads that stick to the skin and deliver mild electrical pulses to the targeted area
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Electrosurgical Pad, also known as a dispersive electrode or grounding pad, is a crucial component used in electrosurgery. It helps to complete the electrical circuit by dispersing the electrical current away from the patient's body, ensuring the safety and effective operation of the electrosurgical unit (ESU)
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
This unit is widely used in many different sectors including plastic surgery, dermatology, ENT, Ophthalmology, somatology, gynecology, proctology, and urology.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| ||||||||||
Content | Features1. LED light positioned between the electrodes enhances the vision during surgery. 2. Massive area hemostasis can be performed in a short time in order to reduce intraoperative blood loss 3. Saline line and dripping device are equipped in an attempt to contain the heat on the treated tissue and avoid thermal tissue damageIndications for Use
| Electrotherapy electrodes with cables are used to connect the electrodes to the electrotherapy device, allowing electrical currents to be delivered to the targeted area. These cables typically have a standard 2mm pin connector that plugs into the device and the electrodes.
There are different types of cables available, such as:
| Features:
Uses:
|
The OBS-50 is a market leader across the world due to its ease of use, high security, power on self test, full-range monitoring, remote control and precise output.
Multiple Applications to meet your different clinic demandsDesiccation
| ||||||||||||
Weight | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||
Dimensions | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||
Additional information |
Reviews
There are no reviews yet.