CO2 Fractional Laser Machine 3 In 1 System
$0.00
Shipped From Abroad
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
co2 fractional laser machine
Specifications
Specification | Fractional CO₂ Laser |
Laser type | USA Coherent laser (RF Tube, lifetime 5-10 years) |
Wavelength | 10600nm |
Systems | Fractional and cutting system standard; Vaginal system optional |
Output Power | 1-40W |
Input Power | 600W |
Output Graphics | Standard Triangles, Rectangles, Circles, Hexagons. Totally 14 graphics available. |
Light guiding system | 7 joints,360° rotation |
Scanning mode | Sequence, Random scanning |
Spot size | 0.08-0.12mm |
Scan area | Up to 20*20mm |
Aiming beam | 650nm red diode laser, laser power 0.1-5mW |
Cooling system | Air fan |
Fractional Skin Resurfacing Working Theory
The new developed RF CO2 fractional laser fires a laser beam through RF CO2 tube which is split into numbers of microscopic beam, producing tinier dot than general CO2 laser (glass tube). The treatment tip can vaporize the outmost layers of the skin across a large surface by creating thousands of tiny, microscopic laser wounds, spaced in an even pattern across the skin, but leaving areas of healthy, untreated skin between them, the lower collagen layer of the dermis is stimulated to renew and repair. Therefore, the heat of laser only passes deeply through the factional damaged area, the surface of skin now contains only microscopic surface wounds, in stead of a large, red, oozing burn. During the skin self-resurfacing, a great amount of collagen is produced for skin rejuvenation, after some recovery, the newly-generated skin is remarkably smoother, healthier.
Vaginal Tightening Working Theory
Vaginal tightening laser is the use of water uptake 10600nm gold standard laser, using a three-dimensional lattice technology and 360-degree circular emission perfect combination of technology, to produce 50-70 degrees Celsius in a controlled depth of the vaginal mucosa, stimulate lamina propria and myometrium newborn fibroblasts, and damaged collagen fibers, elastic fibers, such as restructuring, so as to achieve vaginal wall thickening and tighteningof the vagina so that firmness, sensitivity enhancement, vagina tight as ever.
3 in 1 System (Fractional, Cutting, Gynecology)
We have fractional and cutting 2 systems as standard configuration; gynecology system as optional.
7 Joints 360° Rotation Light Guiding Arm
Korean imported 7 Joints 360° Rotation Light Guiding Arm, output energy is more stable , smallest energy reduction.
14 variable treatment graphics, adjustable shapes, sizes and spacing for different area treatments.
In market there are 2 types of CO2 emitter, glass tube and RF laser tube. We usd 30-40W RF Metal tube from US Coherent, ensure powerful and stable energy.
Why Choose Metal Tube Instead of Glass Tube?
Our RF tube life can reach more than 45,000 hours, generally can be used for at least 6 years, inflatable can be reused, no need to replace; while glass tube is only 8000-10000 hours, usually need to replace the glass tube for half a year, can not be repeated use.
Wide treatment range of Fractional CO2 Laser
Fractional CO2 Laser is widely used in the treatment of dermatology, gynecology, general surgery, ENT and anorectal etc. It has minimal side effects and no down time. Only thermal shocks to tiny area of the skin, little pain, no bleeding.
Quick Comparison
Settings | CO2 Fractional Laser Machine 3 In 1 System remove | Illuco Skin Examination Magnifier remove | Electric Dermatome remove | HONKON-M207 Water Oxygen Facial Cleanser remove | Slimming Beauty Instrument-SlimmingIII+ remove | CryoIQ CIQ-DP-L- Cryo DERM Plus Liquid Device with LED Light (CiQ-A-LED) remove | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Name | CO2 Fractional Laser Machine 3 In 1 System remove | Illuco Skin Examination Magnifier remove | Electric Dermatome remove | HONKON-M207 Water Oxygen Facial Cleanser remove | Slimming Beauty Instrument-SlimmingIII+ remove | CryoIQ CIQ-DP-L- Cryo DERM Plus Liquid Device with LED Light (CiQ-A-LED) remove | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Image | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
SKU | SF1033560130105-31 | SF1033560101-3 | SF10335601214 | SF1033560130100-10 | SF1033560130100-8 | SF1033560096-4 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Rating | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Price |
|
|
|
|
|
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Stock | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Availability | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Add to cart | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Description | Shipped From Abroad
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
This product has a front window operation port, through which the operator can operate inside the safety cabinet. The negative pressure air inhaled from the front window operation port is used to protect the safety of the operator; the downflow filtered by the high efficiency filter is used to protect the experimental articles in the safety cabinet; the air flow filtered by the high efficiency filter is discharged from the safety cabinet to protect the environment.
Delivery & Availability:
Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
1. Skin Graft Thickness: 0-0.75 mm in 0.05 mm increment, the skin thickness
adjusting button is unilateral adjustment, with high stability and no need
calibrate to zero.
2. Skin Graft Width: 2.5~10.2cm,4 size width plates:2.5cm,5.1cm,7.6cm,10.2cm.
Note: Special size width plate can be customized according to requirements.
3. The blade has self-lubricating function and is easy to load and unload. It can move
back and forth smoothly to prevent metal to metal collision.
4. Original imported motor, low inertia electric motor will hardly produce any
vibration when rotating, rotate speed: 4500-5000rpm.
5. Hand held control, easy to operate; handle with contact switch design, safety to use
Delivery & Availability:
Typically 14-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Operation scope:
Water oxygen facial cleanser
1. Clean the epidermis of the skin
2. Rehydrate and oxygenate the skin.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
SlimmingIII+ can effectively reduce excess fat.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped from Abroad
CryoIQ device is perfectly fitted for treatment of warts and other common skin lesions. Its unique construction with a built-in non-return valve prevents gas leakage thus giving a maximum use of the gas content. Areas of application are general practice, dermatology, pediatrics, podiatry, aesthetics, veterinary and gynecology/urology.
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Content | co2 fractional laser machineProfessional clinic use Fractional CO2 Laser with 3 systems
1. Fractional and cutting 2 systems standard; Gynecology system optional
2. Umanized software control, more effective in treatment results
3.14 variable treatment graphics, adjustable shapes, sizes and spacing
4. 7 Joints articulated light guiding arm; Convenient and flexible in operation, greatly reducing energy loss
5. USA imported RF laser tube; steady and even laser output
6. 1-3 times Fast and effective solve scar and vagical problem.
7. 360 degree scanning ability of fractional handle .
8.Minimal side effects and no down time.
9.Wide application for treatment of dermatology, gynecology, general surgery, ENT and anorectal etc.
Specifications
Working Theory
Fractional Skin Resurfacing Working Theory
The new developed RF CO2 fractional laser fires a laser beam through RF CO2 tube which is split into numbers of microscopic beam, producing tinier dot than general CO2 laser (glass tube). The treatment tip can vaporize the outmost layers of the skin across a large surface by creating thousands of tiny, microscopic laser wounds, spaced in an even pattern across the skin, but leaving areas of healthy, untreated skin between them, the lower collagen layer of the dermis is stimulated to renew and repair. Therefore, the heat of laser only passes deeply through the factional damaged area, the surface of skin now contains only microscopic surface wounds, in stead of a large, red, oozing burn. During the skin self-resurfacing, a great amount of collagen is produced for skin rejuvenation, after some recovery, the newly-generated skin is remarkably smoother, healthier.
Vaginal Tightening Working Theory
Vaginal tightening laser is the use of water uptake 10600nm gold standard laser, using a three-dimensional lattice technology and 360-degree circular emission perfect combination of technology, to produce 50-70 degrees Celsius in a controlled depth of the vaginal mucosa, stimulate lamina propria and myometrium newborn fibroblasts, and damaged collagen fibers, elastic fibers, such as restructuring, so as to achieve vaginal wall thickening and tighteningof the vagina so that firmness, sensitivity enhancement, vagina tight as ever.
3 in 1 System (Fractional, Cutting, Gynecology)
We have fractional and cutting 2 systems as standard configuration; gynecology system as optional.
7 Joints 360° Rotation Light Guiding Arm Korean imported 7 Joints 360° Rotation Light Guiding Arm, output energy is more stable , smallest energy reduction. 14 Graphics
14 variable treatment graphics, adjustable shapes, sizes and spacing for different area treatments. RF Metal Laser Tube from US Coherent
In market there are 2 types of CO2 emitter, glass tube and RF laser tube. We usd 30-40W RF Metal tube from US Coherent, ensure powerful and stable energy. Why Choose Metal Tube Instead of Glass Tube? Our RF tube life can reach more than 45,000 hours, generally can be used for at least 6 years, inflatable can be reused, no need to replace; while glass tube is only 8000-10000 hours, usually need to replace the glass tube for half a year, can not be repeated use. Wide treatment range of Fractional CO2 Laser Fractional CO2 Laser is widely used in the treatment of dermatology, gynecology, general surgery, ENT and anorectal etc. It has minimal side effects and no down time. Only thermal shocks to tiny area of the skin, little pain, no bleeding.1- Skin resurfacing (Rough skin, coarse pores, dark skin, light damage…)
2- Wrinkles (Crow’s feet, head lines, Sichuan characters, Decree lines)
3- Pigmented nevus, epidermal pigmentation (freckles, etc.), epidermis (all kinds of warts) cutting
4- Scar Repair (acne scar, hypertrophic scar, burn scar, sunken scar, etc.)
5- Other applications (syringoma, condyloma, seborrheic, etc.)
6- Vaginal care (Vaginal wall tightening, collagen remodeling, thicker and more resilient, labium whitening)
| Features:
Click Here To Download Catalogue | Electric DermatomeTechnical Parameters: 1. Skin Graft Thickness: 0-0.75 mm in 0.05 mm increment, the skin thickness adjusting button is unilateral adjustment, with high stability and no need calibrate to zero. 2. Skin Graft Width: 2.5~10.2cm,4 size width plates:2.5cm,5.1cm,7.6cm,10.2cm. Note: Special size width plate can be customized according to requirements. 3. The blade has self-lubricating function and is easy to load and unload. It can move back and forth smoothly to prevent metal to metal collision. 4. Original imported motor, low inertia electric motor will hardly produce any vibration when rotating, rotate speed: 4500-5000rpm. 5. Hand held control, easy to operate; handle with contact switch design, safety to use. 6. Exclusive design of pulled and plugged handle connection line, easy to use. (the length of handle connection line is greater than 3m) 7. Power supply: 220V±10% AC automatic switching, 150/60Hz single phase. Output 14.5V DC, 4.3A. 8. Degree of prevention of liquid entry: IPXO. 9. Sterilization Method: Sterilization Mode: pre-vacuum and gravity displacement steam sterilization or low temperature plasma sterilization can be conducted in whole machine and power cord. And the power cord can be pulled and plugged. | Principle of Operation
How it works: HONKON's water oxygen cleanser fully combines oxygen and nutrient solution, and sprays water vapor mixed particles from the nozzle at a speed of 230m/s (similar to the spray form) to act on the skin. The fine particles with a diameter of about 50-80um (smaller than the diameter of the pores) clean the skin from the epidermis to the basal layer below the epidermis. If nutrients are added to the base liquid, the internal environment of the skin can be adjusted, which can replace manual skin care.Operating range: 1. Clean the epidermis of the skin 2. Hydrate and oxygenate the skin.Product advantages: The high-pressure gas is mixed with the nutrient solution through a stainless steel needle and sprayed out water vapor particles with a diameter of about 50μm at a speed of up to 230m/s. Oxygen pressure gauge, real-time pressure display. The gas output flow control system can adjust the gas output volume and gas output pressure according to different parts. It can be used with nutrient solution products to achieve better results. The liquid output flow control system can adjust the liquid output volume and liquid output pressure according to different parts, which is more targeted.Technical Parameters: Water mist particle speed: ≤230m/s Built-in air source output pressure: ≤0.8MPa Number of instruments: 4 Water mist particle diameter: ≤80um Gas source type: built-in gas source 5L gas tank Water oxygen pen: O-II Number of water oxygen pens: 2 Insurance specification: Max6A Power supply: AC220V±10%, 50HZ, AC110V±10%, 60HZ Gear: 1-2 gears adjustable, one gear step Accessories Details: O—II Water Oxygen Pen It is beautiful, easy to use, and can be repaired after damage, which reduces the user's cost of use; the deep cleaning effect is obvious; customers are advised to stock up on water oxygen pens O-Ⅱ type for emergencies. | https://youtu.be/5a5fX8EW_NU?si=IZo4_PID1DkrBpgr
How it works: The HONKON-Slimming system mainly uses four methods: roller machinery, vacuum negative pressure adsorption, bipolar radiofrequency thermal melting, and red light and infrared light operation to produce an operating effect on the skin through synergistic effects.Operating range: Face, neck, limbs, buttocks and abdomen, face and buttocks firming, postpartum and postoperative body recovery. Reduce excess fat. Skin firming: strengthen the skin, increase skin elasticity, etc.Product advantages: 4 types of operating handpiece configurations: can easily achieve body shaping, skin tightening, skin texture, etc. according to different parts, projects, demands, etc. Control system: adsorption strength, adsorption frequency, roller speed, roller direction, red light intensity, radio frequency power, etc. can all be adjusted to meet the patient's demands. Dual monopolar radio frequency system: The dual monopolar radio frequency system with 2.64M radio frequency power source avoids epidermal burns. The radio frequency energy acts more concentratedly on the target tissue (subcutaneous tissue), the pain is milder, and the number of times is significantly reduced.Technical Parameters: Number of handpieces: 4 Handpiece models: XF-I+, XF-VII+, XF-VIII, XF-IX Mechanical roller: ≤20R/min (and the speed increases with the increase of infrared light power) RF frequency: 2.64MHz Red light intensity: IV level adjustable Negative pressure flow: ≤140L/min Red light wavelength: 700-2000nm Red light power: ≤20W Negative pressure intensity: ≤-0.09MPa Adsorption intensity: I-VIII adjustable RF power: 400WAccessories Details:
XF-I+ operating tool
XF-VII+ operating tool
XF-VIII operating tool
XF-IX operating tool
| CryoIQ device is perfectly fitted for treatment of warts and other common skin lesions. Its unique construction with a built-in non-return valve prevents gas leakage thus giving a maximum use of the gas content. Areas of application are general practice, dermatology, pediatrics, podiatry, aesthetics, veterinary and gynecology/urology. The device uses a state-of-the-art cooling technology that does not require handling of potentially dangerous gases and liquids meaning that the gas cartridge is safely replaced when empty. The device features an ergonomic design where the cooling medium is evenly, accurately and economically distributed by depressing the metering lever.
Features:
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Weight | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Dimensions | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Additional information |