Description | Shipped From Abroad
18mm
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped from abroad
AutoSight 900 is a portable vision screener for patients at any age. Its working principle is the refraction of light.
Delivery & Availability:
Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped from abroad
- Large color liquid-crystal screen
- Touch screen input, easy operation
- Curve freezing: Manual/Auto mode, controlled by pedal
- Built-in speed thermal printer
- Enter the name & ID; easy to check archive
Delivery & Availability:
Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped from abroad
- Large color liquid-crystal screen.
- Touch screen input, easy operation.
- Curve freezing: Manual/Auto mode, controlled by pedal.
- Built-in speed thermal printer.
- Can display ultrasound waveform when measuring.
Delivery & Availability:
Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped from abroad
The product is designed on the principle basis of Goldman tonometer. It can be connected with slit lamp(Carl Zeiss type).
Delivery & Availability:
Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped from abroad
- 7.0-inch color LCD touch panel.
- Hartman sensor with 108 multiple measure points.
- Green measurement light beam.
- Dyeing lens, sunglasses measured easily.
Delivery & Availability:
Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
|
Content | | Handheld Digital Auto-refractometer(AutoSight 900) is a portable vision screener for patients at any age. Its working principle is the refraction of light. Optical rays are focused on a sensor after passing through the eye's refractive system. The spherical power, cylindrical power, and axis of both eyes can be obtained by digital signal processing.
Features of Handheld Digital Auto-refractometer:
- Quick: Automatic and convenient. Press the button at the working distance (35cm/14in) and that's it. The result will be automatically shown in 5 seconds.
- Accurate: Objective measurement of diopter is obtained from optical signal. The result is not affected by various external factors.
- Intelligent: Detects multiple eye problems in one measurement including myopia, hyperopia, astigmatism and anisometropia
Technical Specifications of Handheld Digital Auto-refractometer:
Item |
Range |
Interval |
Tolerance |
Spherical (S) |
Myopia Mode |
-9.00D~ +2.50D |
0.25D |
±0.50D or ±20%
(whichever is greater) |
Normal Mode |
-6.00D ~ +8.00D |
Cylindrical(C) |
-3.00D~0.00D |
0.25D |
±0.50D or ±20%
(whichever is greater) |
Axis(A) |
0°~180° |
1° |
±5° |
| Feature:
- Large color liquid-crystal screen
- Touch screen input, easy operation
- Curve freezing: Manual/Auto mode, controlled by a pedal
- Built-in speed thermal printer
- Enter the name & ID; easy to check the archive
Technical Specifications:
Model |
SW-1000 Ophthalmic A Scan Biometer |
A Scan |
A scan probe |
10MHz import small size probe, built-in luminotron |
Measuring range |
15mm-40mm |
Measurement precision |
±0. 05mm; with macula lutea trace function |
Measurement |
Anterior chamber depth, lens thickness, vitreous body length, total length and average |
Method of measurement |
immersion and contact |
Eye mode |
Phakic/ Aphakic/Dense/ various IOL |
IOL formula |
SRK-II, SRK-T, BINKHORST- Ⅱ, HOLLADAY, HOFFER-Q, HAIGIS |
Storage |
10 cases, 5 readings each case |
Output |
A scan waveform and IOL calculation sheet
|
| Features:
- Large color liquid-crystal screen.
- Touch screen input, easy operation.
- Curve freezing: Manual/Auto mode, controlled by pedal.
- Built-in speed thermal printer.
- Can display ultrasound waveform when measuring.
- Each group is the average of 20 measurements.
- Switch between IOP measured value and actual value.
- Can input name, ID and operator's name.
Technical Specifications:
P scan probe |
20MHZ, angle of 45 degrees makes easier operation |
Resolution |
5um |
Measuring range |
150um~1500um |
Display |
SINGLE mode and MAP mode |
| Applanation Tonometer is designed on the principle basis of Goldman tonometer. It can be connected with slit lamp(Carl Zeiss type).
Features of Applanation Tonometer:
- When used with slit lamp, it can be used to examine the eyes and measure ocular pressure.
- Accurate measurement and total tolerance are less than 0.066KPa(0.55Hg).
- Directly get the ocular pressure and do not need to look up the conversion table.
- The measured ocular pressure is not affected by hardness of eye.
- The affected?ocular volume is just 0.56 cubic millimeter.
- Adjustable measuring pressure ensures the long-term stability and reliability.
Technical Specifications Applanation Tonometer:
- Measuring Range: 0~1064 Kpa
- Light Ring Displacement: 1.53×2=3.06mm
- Diameter of Prism Head: 7mm
- Moving Range of Prism Head: 3mm
| Features:
- 7.0-inch color LCD touch panel.
- Hartman sensor with 108 multiple measure points.
- Green measurement light beam.
- Dyeing lens, sunglasses measured easily.
Technical Specifications:
- Sphere lenses: 0~±25D
- Cylinder lenses: 0~±10D
- Cylinder Axis Angle: 0°~180°
- Add.:0~10D
- Power supply: 100~240V, 50/60HZ, 30W
- Weight: 5kg
|
Reviews