Dolphin-4D Transcranial Doppler Probe

$0.00

Shipped From Abroad

The cutting-edge technology of the standalone Dolphin/4D transcranial Doppler system is the optimal TCD solution for measurements of cerebral blood flow velocities.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130142-1
Brands:: VIASONIX

Description

Features of Dolphin TCD Machine

Best Quality Doppler

Fully digital Doppler technology with the amazing Dolphin TCD post-processing capabilities lets you review and replay the measured spectrum with audio at any depth. Unmatched clinical diagnosis capabilities.

Best TCD Robotic Probe

The unique Dolphin/XF robotic probe changes the Transcranial Doppler monitoring market as is known to date. Fast and simple scanning is achieved thanks to special algorithms and processes for blood flow detection. The Dolphin/XF robot is comfortable and stable, simplifying probe fixation and saving time.

Continuous Monitoring Made Easy

The Dolphin devices are well designed to assist the technician or physician in performing short or long-term Monitoring. The Dolphin Headset design comes with the unique probe Quick-Lock – the best locking solution. The Dolphin software is rich with quality features for optimal patient diagnosis, including a complete replay of the entire recording, placement of automatic and predefined markers, and availability of trends display.

Unbeatable Durability and Reliability

The Dolphin is considered by many as the most reliable Transcranial Doppler machine in the market. A range of high-quality Doppler probes is available for different clinical applications and optimal Doppler penetration of the temporal window.

Designed for Portability

The Dolphin TCD machines are the most portable TCD machine on the market. Dolphin/MAX and Dolphin/4D are slim, lightweight, and have a large 18″ Touch Screen, which can be seen from a distance in the ICU or other clinical settings. Their design allows you to simply hand carry them or use the VESA mount options to easily connect the TCD system to a cart or trolley. The Dolphin/MAX has a built-in integrated battery that lasts for hours.

Complete Network Connectivity

The unmatched Dolphin connectivity capabilities are ideal for hospital IT personnel and EMR / PACS administrators. The advanced Dolphin TCD networking abilities allow a simple plug-and-play operation to quickly configure connectivity with automated DICOM Worklist & Storage, Structured Report, and HL7. With unlimited Review Stations, measurements can be reanalyzed and interpreted from the comfort of your office. Final reporting can also be configured and finalized from any location.

Unmatched HITS Detection

Optimal and accurate counts of suspected embolic events using a high-resolution proprietary algorithm that simultaneously detects HITS (emboli events) in all gates! The numerous advanced analysis options of each suspected emboli include an extraordinary high-resolution power M Mode display during HITS detection (up to 50 times faster than the Doppler spectrum!).

Reviews

There are no reviews yet.

Be the first to review “Dolphin-4D Transcranial Doppler Probe”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsDolphin-4D Transcranial Doppler Probe removeCryoIQ CIQ-DP-L- Cryo DERM Plus Liquid Device with LED Light (CiQ-A-LED) removeAgary I.V. Cannula removeAnesthetic Face Mask removeLab/Ward Coat removeHersill Genesis Anaesthetic Machine remove
NameDolphin-4D Transcranial Doppler Probe removeCryoIQ CIQ-DP-L- Cryo DERM Plus Liquid Device with LED Light (CiQ-A-LED) removeAgary I.V. Cannula removeAnesthetic Face Mask removeLab/Ward Coat removeHersill Genesis Anaesthetic Machine remove
ImageHersill Genesis Anaesthetic Machine
SKUSF1033560130142-1SF1033560096-4SF1033560084-221SF1033560084-141SF1033560084-222SF1033560450-1
Rating
Price

$0.00

$0.00

$7.10

$8.00

$11.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad The cutting-edge technology of the standalone Dolphin/4D transcranial Doppler system is the optimal TCD solution for measurements of cerebral blood flow velocities.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad CryoIQ device is perfectly fitted for treatment of warts and other common skin lesions. Its unique construction with a built-in non-return valve prevents gas leakage thus giving a maximum use of the gas content. Areas of application are general practice, dermatology, pediatrics, podiatry, aesthetics, veterinary and gynecology/urology.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock I.V Cannula with wings & injection port 24G/19mm, 0.70mm/20ml/min Injection port with unidirectional valve for facilitating extra medication and preventing back flow. Specially engineered recessed plug with protective ring to avoid risk of contamination. Angle & grooved wings for easy cannulation and to prevent rolling of cannula over patient body. Colour coded cap for easy identification of guage size.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock Four sizes from small adult to extra large adult. A range of color-coded economy anesthetic face masks for single patient use to prevent the possibility of cross infection.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • This white coat laboratory coat is a knee-length overcoat/smock is perfect for professionals in the medical field or by those involved in laboratory work.
  • This garment is Easy to wash and made from a cotton polyester blend, allowing it to be washed at high temperature and make it easy to see if it is clean.
  • Easy to wash.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad The Genesis anaesthesia workstations meet your most ambitious requirements. They stand out for their lung protective ventilation. Application Field: Neonates, Pediatrics & Adults Ventilation Modes: Volume controlled (VC), Pressure controlled (PC), Adaptive Pressure with Volume Guaranteed (APVG) & Pressure Support Ventilation (PSV) Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Contenthttps://youtu.be/Id0Ma1_lEo0?si=MmwcCTMMPZd_jf6h
Features of Dolphin TCD Machine

Best Quality Doppler

Fully digital Doppler technology with the amazing Dolphin TCD post-processing capabilities lets you review and replay the measured spectrum with audio at any depth. Unmatched clinical diagnosis capabilities.

Best TCD Robotic Probe

The unique Dolphin/XF robotic probe changes the Transcranial Doppler monitoring market as is known to date. Fast and simple scanning is achieved thanks to special algorithms and processes for blood flow detection. The Dolphin/XF robot is comfortable and stable, simplifying probe fixation and saving time.

Continuous Monitoring Made Easy

The Dolphin devices are well designed to assist the technician or physician in performing short or long-term Monitoring. The Dolphin Headset design comes with the unique probe Quick-Lock – the best locking solution. The Dolphin software is rich with quality features for optimal patient diagnosis, including a complete replay of the entire recording, placement of automatic and predefined markers, and availability of trends display.

Unbeatable Durability and Reliability

The Dolphin is considered by many as the most reliable Transcranial Doppler machine in the market. A range of high-quality Doppler probes is available for different clinical applications and optimal Doppler penetration of the temporal window.

Designed for Portability

The Dolphin TCD machines are the most portable TCD machine on the market. Dolphin/MAX and Dolphin/4D are slim, lightweight, and have a large 18″ Touch Screen, which can be seen from a distance in the ICU or other clinical settings. Their design allows you to simply hand carry them or use the VESA mount options to easily connect the TCD system to a cart or trolley. The Dolphin/MAX has a built-in integrated battery that lasts for hours.

Complete Network Connectivity

The unmatched Dolphin connectivity capabilities are ideal for hospital IT personnel and EMR / PACS administrators. The advanced Dolphin TCD networking abilities allow a simple plug-and-play operation to quickly configure connectivity with automated DICOM Worklist & Storage, Structured Report, and HL7. With unlimited Review Stations, measurements can be reanalyzed and interpreted from the comfort of your office. Final reporting can also be configured and finalized from any location.

Unmatched HITS Detection

Optimal and accurate counts of suspected embolic events using a high-resolution proprietary algorithm that simultaneously detects HITS (emboli events) in all gates! The numerous advanced analysis options of each suspected emboli include an extraordinary high-resolution power M Mode display during HITS detection (up to 50 times faster than the Doppler spectrum!).
CryoIQ device is perfectly fitted for treatment of warts and other common skin lesions. Its unique construction with a built-in non-return valve prevents gas leakage thus giving a maximum use of the gas content. Areas of application are general practice, dermatology, pediatrics, podiatry, aesthetics, veterinary and gynecology/urology. The device uses a state-of-the-art cooling technology that does not require handling of potentially dangerous gases and liquids meaning that the gas cartridge is safely replaced when empty. The device features an ergonomic design where the cooling medium is evenly, accurately and economically distributed by depressing the metering lever. Features:
  • Simple pencil type grip for an easy and very accurate application
  • Freezing temperature
    • Liquid spray freezing, -89°C / -128°F
  • Level of cold generated is adjusted by the rate at which the metering lever is depressed
  • CE marked according to Medical Device IIa
  Technical Specifications: Name: CryoIQ® DERM plus Liquid Order.no: CIQ-DP-L Delivered in: Plastic case Included in delivery: 1 gas cartridge (16 gram) with valve Weight: 82 gram (including 16 gram cartridge) Dimensions: Diameter: 22 mm / Length: 120 mm Freezing temperature: -89°C / -128°F Material: Gold plated metal Patented: Yes CE marked: According to medical device IIA Warranty: 1 years (2 years after Product registration) Gas cartridge: 16 or 25 gram Nitrous Oxide Gas (N2O) Medical sterile Built-in filter (5 µm)  
I.V Cannula with wings & injection port 24G/19mm, 0.70mm/20ml/min Injection port with unidirectional valve for facilitating extra medication and preventing back flow. Specially engineered recessed plug with protective ring to avoid risk of contamination. Angle & grooved wings for easy cannulation and to prevent rolling of cannula over patient body. Colour coded cap for easy identification of guage size.Four sizes from small adult to extra large adult. A range of color-coded economy anesthetic face masks for single patient use to prevent the possibility of cross infection. Features:
  • Soft cushion for patient comfort and air tight fit
  • Clear flexible housing and cushion for good patient visibility
  • Four sizes available, from small adultl to extra large adult
  • Each mask supplied with color-coded hook ring.
  • This white coat laboratory coat is a knee-length overcoat/smock is perfect for professionals in the medical field or by those involved in laboratory work.
  • This garment is Easy to wash and made from a cotton polyester blend, allowing it to be washed at high temperature and make it easy to see if it is clean.
  • Easy to wash.
The Genesis anaesthesia workstations meet your most ambitious requirements. They stand out for their lung protective ventilation, accuracy and performance, cost saving, design and ergonomics, safety and versatility.   TECHNICAL SPECIFICATION OPERATING DATA
  • Weight - 105 kg
  • Dimensions - 92 cm Wide x 68 cm Deep x 139 cm High (93 cm to the table surface)
  • Packaging Dimensions - 105 cm Wide x 75 cm Deep x 160 cm High
  • Operating voltage supply - 110 to 240 V~, 47 to 63 Hz (12 to 6 A)
  • Power input - 120 W typically (max. 1.2 kW with auxiliary outlets used)
  • Battery autonomy - 90 min typically
  • Auxiliary power outlets - 4, with automatic protection
  • O2, N2O and Air supply - 2.7 to 6.9 bar (39.1 to 100 psi)
  • Screen - TFT 18.5" (47 cm) projected capacitive touchscreen
  • Protection class - Class I, gas analyser type BF defibrillation proof
  • Classification - Class II b
  • Storage - One front drawer with self-brake system and two back cabinets with door
  • Lighting - LED bar below the screen controlled from the touchscreen
  • Auxiliary integrated systems - Auxiliary 02 flow meter (0-15 L/min), Auxiliary 02 suppy valve (NF standard) and Suction device
  • Communication ports - 1 x RS-232, 2 x USB, 1 x LAN Ethernet
Fresh Gases (02, N20 and Air, electronically controlled)
  • Fresh gas flow - 0 and 0.1 to 18 L/min 02/N20/Air
  • Accuracy - 0.1 to 0.5 L/min = ±0.05 L/min; 0.5 to 18 L/min = ±10 %
  • 02 concentration - 21 to 100% vol. with Air, 25 to 100% with N20 (minimum 200 ml/min 02)
  • 02 Safety fresh gas (backup) - 0-0.2-0.4-0.7-1-1.5- 2- 3- 4- 6- 8-10-12-15 L/min 02
  • 02 flush (+02) - 40 L/min standard (adjustable 25 - 75 L/min upon requirement)
Breathing System (CABS)
  • Autoclavable - 134 °C
  • Weight of breathing system - 9.8 kg
  • C02 absorber volume - 1.5 L
  • Leakage - < 150 mL/min (at 30 hPa)
  • Pressure limiting valve APL - 0 to 70 hPa
  • Pressure relief valve - 125 hPa
  • Vacuum safety valve - 0.3 hPa
  • resistance at 60L/min - 5.80 hPa
  • resistance at 60L/min - 2.90 hPa
  • resistance at 30L/min - 3.55 hPa
  • resistance at 30L/min - 0.89 hPa
  • Internal Compliance at 30 hPa - 15 mL
  VENTILATOR Operation / Ventilation Modes Volume controlled (VC) modes:
  • Volume Controlled Ventilation (VCV)
  • VC Synchronized Intermittent Mandatory Ventilation (VC-SIMV)
  • VC-SIMV with Pressure Support (VC-SIMV-PS) *
Pressure controlled (PC) modes:
  • Pressure Controlled Ventilation (PCV)
  • PC Synchronized Intermittent Mandatory (PC-SIMV)
  • PC-SIMV with Pressure Support (PC-SIMV-PS) *
Adaptive Pressure with Volume Guaranteed (APVG) modes (other trade names: Autoflow,PCVR, PRVC, AVAPS, VC+)
  • Adaptive Pressure with Volume Guaranteed (APVG) *
  • APVG Synchronized Intermittent Mandatory (APVG-SIMV) *
  • APVG -SIMV with Pressure Support (APVG-SIMV-PS) *
Pressure Support Ventilation (PSV) *
  • (other trade names: PS, ASB, SPS, IPS)
  Non-mechanical Operation / Ventilation Modes
  • Manual ventilation through the CABS system (Auto/Manual software controlled)
  • Spontaneous ventilation either through the bellows (auto mode) or through the bag
  • (manual mode) Manual ventilation through the external fresh gas outlet for non-rebreathing systems (Bain, Mapleson, ...)
Application field: Neonates, Pediatrics & Adults
  • Tidal volume - 5 to 1500 mL
  • Inspiratory pressure - 0 to 68 hPa
  • Ventilation frequency ­- 3 to 120/min
  • Inspiratory time - 0.05 to 16.6s
  • l:E ratio - 5:1 to 1:8
  • Inspiratory pause - 0 to 60%
  • Inspiratory flow - max. 150 L/min
  • PEEP - 0 to 30 hPa
  • Flow trigger - 0.2 to 15 L/min
  • Pressure support - 5 to 50 hPa
  • Ramp time - 0.1 to 2 s
  • Maximum pressure - 0 to 68 hPa
  MONITORING
  • 5" (47 cm) projected capacitive touchscreen, supported on a 360° rotating and 2 axis tilting arm.
  • Measurements displayed: Peak pressure; Plateau pressure; Mean pressure; Expiratory minute ventilation; Expiratory tidal volume; Inspiratory tidal volume; Expiratory volumeter; Breathing rate; Compliance and Resistance (in VC modes); Patient info (age, weight, MAC, Class ASA); Connected sensors; Battery status; Power supply status; Gases supply pressures for 02, N20 and Air; Inspiratory and expiratory concentration of 02, N20, C02 and Anaesthetic gas*
  • Parametres charted as curves (up to 3 simultaneously): Airway pressure; Expiratory flow; Inspiratory flow; Volume; Fresh gases (Rotstyle); Concentration of 02, N20, C02 and Anaesthetic gas*; Trends: Minute volume, MAC and gases (02, N20, C02 and Anaesthetic gas).
  • Display for the performance of the hospital Anaesthetic Gas Scavenging System (AGSS).
  • Configurable interface: bright/dark, multi-language.
  • Loops (up to 2 simultaneously): Volume-Pressure, Flow-Volume, Pressure-Flow, C02-Volume.
  • Fresh gas virtual rotameters for 02, N20, Air. * C02, N20 and Anaesthetic gas monitoring with the accessory multigas analyzer main-stream or side-stream; 02 real-time monitoring via paramagnetic
 
Click Here To Download Catalogue
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare