![Sterilization oven PE-4610M](https://halomedicals.com/wp-content/uploads/2021/09/Sterilization-oven-PE-4610M-570x570.jpg)
Drying oven PE-4610M (horizontal) (60 L / 320°С)
Ask for Price$0.00
Shipped From Abroad
The drying oven is to be used for drying, firing, melting, curing and sterilization of various articles, treatment of tools and samples as well as performance of laboratory investigations of every sort and kind in the laboratories of industrial enterprises, research establishments and medical institutions, colleges, universities, etc.
Delivery & Availability:
Typically 14-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
Purpose:
The drying oven is to be used for drying, firing, melting, curing and sterilization of various articles, treatment of tools and samples as well as performance of laboratory investigations of every sort and kind in the laboratories of industrial enterprises, research establishments and medical institutions, colleges, universities, etc.
The following functions are implemented in the device:
– maintenance of the specified temperature with the required accuracy;
– digital indication of the specified temperature and current temperature of the working chanber;
– overheating protection with the operation alarm;
– setting the timer to stopping the heating;
– control of the rotation speed of the fan
Technical specifications:
– Working temperature range, °C – from ambient +50 to +300
– Temperature setting discreteness, °C – ±1
– Temperature non-uniformity throughout the volume, °C – ±2.5
– Chamber volume, l – 56
– Standard/maximum number of shelves, pcs – 3/5
– Power consumption, W – 1600
– Supply voltage, V – 220 V, 50 Hz
– Internal dimensions, mm – 390x350x410
– External dimensions, mm – 755x660x630
– Weight, kg – 50
The scope of delivery of the standard equipment includes:
1. Drying oven PE-4610M – 1 pc.
2. Shelf made of stainless steel – 2 pcs.
3. Mains cable – 1 pc.
4. Data Sheet and Operating Manual – 1 pc.
Quick Comparison
Drying oven PE-4610M (horizontal) (60 L / 320°С) remove | Motic BA210 Series Biomedical Microscope remove | Erma B-111 Bilirubin Meter remove | Little Sister Table Top Autoclave remove | Avalun 48 INR Microcuvette remove | Skyla Hi POC Clinical Chemistry Analyzer remove | |||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Name | Drying oven PE-4610M (horizontal) (60 L / 320°С) remove | Motic BA210 Series Biomedical Microscope remove | Erma B-111 Bilirubin Meter remove | Little Sister Table Top Autoclave remove | Avalun 48 INR Microcuvette remove | Skyla Hi POC Clinical Chemistry Analyzer remove | ||||||||||||||||||||||||||||||||||||
Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ||||||||||||||||||||||||||||||||||||
SKU | SF10335601089 | SF1033560084-78 | SF1033560084-6 | SF1033560084-46 | SF1033560084-74 | SF1033560060-2 | ||||||||||||||||||||||||||||||||||||
Rating | ||||||||||||||||||||||||||||||||||||||||||
Price | Ask for Price | Ask for Price | Ask for Price | $1,350.00 | Ask for Price | Ask for Price | ||||||||||||||||||||||||||||||||||||
Stock | Out of stock | |||||||||||||||||||||||||||||||||||||||||
Availability | Out of stock | |||||||||||||||||||||||||||||||||||||||||
Add to cart | ||||||||||||||||||||||||||||||||||||||||||
Description | Shipped From Abroad
The drying oven is to be used for drying, firing, melting, curing and sterilization of various articles, treatment of tools and samples as well as performance of laboratory investigations of every sort and kind in the laboratories of industrial enterprises, research establishments and medical institutions, colleges, universities, etc. Delivery & Availability: Typically 14-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock The BA210 series is a line of basic biological microscopes manufactured by Motic. The unit is equipped with Motic Infinity Optics (CCIS®, offering quality performance in the fields of education and training. The device features a coaxial coarse and fine housing with a quadruple reverse-mounted nose piece. Its contrast methods, such as phase contrast, polarization and dark field, are easily performed through optional accessories. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped From Aboard
The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.
Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Out stock Little Sister Table Top Autoclave: This sterilizer is a table type in safety and auto controlled,which is designed for the unit of medical health, pharmacy, science and technology and mostly suitable for sterilizing of surgical,dental and eye instruments, glassware medicine, culture medium and biological dressing, food and other goods. Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Out stock LabPad®’s versatility comes especially from its Tsmart® single-use microcuvette, which contains a lyophilized reagent specific to each test. The Tsmart® microcuvette is the fruit of numerous innovations that have led to many benefits for users. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped from Abroad The skyla Hi POC Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results.The use of skyla Hi in the management of diabetes enables better access to testing and rapid clinical decision making, discussion,and implementation of optimized treatment. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | ||||||||||||||||||||||||||||||||||||
Content | Purpose: The drying oven is to be used for drying, firing, melting, curing and sterilization of various articles, treatment of tools and samples as well as performance of laboratory investigations of every sort and kind in the laboratories of industrial enterprises, research establishments and medical institutions, colleges, universities, etc. The following functions are implemented in the device: - maintenance of the specified temperature with the required accuracy; - digital indication of the specified temperature and current temperature of the working chanber; - overheating protection with the operation alarm; - setting the timer to stopping the heating; - control of the rotation speed of the fan Technical specifications: - Working temperature range, °C – from ambient +50 to +300 - Temperature setting discreteness, °C - ±1 - Temperature non-uniformity throughout the volume, °C - ±2.5 - Chamber volume, l – 56 - Standard/maximum number of shelves, pcs – 3/5 - Power consumption, W – 1600 - Supply voltage, V – 220 V, 50 Hz - Internal dimensions, mm – 390x350x410 - External dimensions, mm – 755x660x630 - Weight, kg – 50 The scope of delivery of the standard equipment includes: 1. Drying oven PE-4610M – 1 pc. 2. Shelf made of stainless steel – 2 pcs. 3. Mains cable – 1 pc. 4. Data Sheet and Operating Manual – 1 pc. | The BA210 series is a line of basic biological microscopes manufactured by Motic. The unit is equipped with Motic Infinity Optics (CCIS®, offering quality performance in the fields of education and training. The device features a coaxial coarse and fine housing with a quadruple reverse-mounted nose piece. Its contrast methods, such as phase contrast, polarization and dark field, are easily performed through optional accessories. Technical applications: Biomedical Type: Optical Observation technique: Dark field Magnification: 4 unit, 10 unit, 40 unit, 100 unit | The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric
analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.
Feature
| Little Sister Table Top Autoclave: This sterilizer is a table type in safety and auto controlled,which is designed for the unit of medical health, pharmacy, science and technology and mostly suitable for sterilizing of surgical,dental and eye instruments, glassware medicine, culture medium and biological dressing, food and other goods.
Features:
| LabPad®’s versatility comes especially from its Tsmart® single-use microcuvette, which contains a lyophilized reagent specific to each test. The Tsmart® microcuvette is the fruit of numerous innovations that have led to many benefits for users.
Features:
| skyla Hi Analyzer enables better access to testing and rapid clinical decision making, discussion, and implementation of optimized treatment. To get the result, only prepare <1 μl fingertips blood or venous blood (depends on test item) without pretreatment with easy steps and then read the result after 6 mins. The device allows two specimens be tested in one run and provides fully automatic procedures from checking the validity of cartridge to printing the results.
Reagent Kit
Main SpecificationPrinciple
Turbidimetric Method / Biochemistry
Device
Testing Time
5~20 minutes (depends on test items)
Display and Interface
5″ TFT color touch screen LCD
Memory Capacity
50,000 test results
Dimension of Analyzer
270 x 188 x 148 mm
Weight of Analyzer
1.7 kg
Dimension of Printer Module
134 x 100 x 82.7 mm
Weight of Printer Module
0.37 kg
Power Supply
100~240 volts AC, 50-60Hz
Data Transmission
USB 2.0*4 / USB 3.0*1 / RS232*1 / RJ45*1 / Wi-Fi (optional)
Reagent and SamplesSamples
Fingertips blood or venous blood
Samples Volume
0.8 ~ 30 μL (depends on test item)
Storage Temperature (Reagent)
2 ~ 8˚C
HumidityRelative humidity < 95% (Non-condensing)
| ||||||||||||||||||||||||||||||||||||
Weight | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||||||||||||||||
Dimensions | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||||||||||||||||
Additional information |
Reviews