Ducted Fume Hood

$0.00

Shipped From Abroad

FMH (A) series ducted fume hood is designed as a negative pressure ventilation system that ensures the safety of operators and the laboratory environment. It works by drawing room air inward through the front opening of the hood and continuously ventilating it with an extraction blower. This prevents the spread of contaminated fumes, vapors, toxic gases, aerosols, and corrosive substances that may be generated during experiments. Furthermore, an optional active carbon filter can purify the polluted air before it is exhausted through the duct, thereby protecting the outdoor environment as well.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130127-39
Brands:: Scitek

Description

Ducted Fume Hood Features:
  1. UV lamp for sterilization.
  2. Resistant to weak acid and alkali.
  3. Adjustable air speed: 3 levels.
  4. Manual or motorized front window, height adjustable.
  5. Microprocessor control system, LCD display.
  6. With memory function in case of power-failure.
  7. New design, with a liquid collection tank behind the backpanel to collect the waste liquid generated during the experiment and reduce pollution.
  8. Front panel with bypass Grille, Sash air foil and bypass system achieve function of Air supplement. Meets North American fume hood design standards.

 

Product Data
  • External Size : 3ft / 4ft / 5ft / 6ft
  • Maximum Opening : 520mm
  • Work Surface Height : 850mm
  • Airflow Velocity : Adjustable 0.3~0.8 m/s
  • Exhaust Duct : Φ300mm PVC (Standard Length: 10 meters)

 

Ducted Fume Hood Specifications:
Model FMH-1000DA FMH-1200DA FMH-1500DA FMH-1800DA
FMH-1000DA(II) FMH-1200DA(II) FMH-1500DA(II) FMH-1800DA(II)
External Size (WxDxH)(mm) 1040x800x2200 1240x800x2200 1540x800x2200 1840x800x2200
Internal Size (WxDxH)(mm) 820x670x730 1020x670x730 1320x670x730 1620x670x730
Front Window Manual (FMH-DA series),  Motorized (FMH-DA(II) series) 5mm toughened glass; Height adjustable.
Work Surface Height 850mm
Max Opening 520mm
Air Velocity 0.3~0.8m/s
Sound Emission ≤68dB
Exhaust Duct PVC, Standard Length: 10 meters.
Φ300mm
LED Lamp 8Wx1 12Wx1 16Wx1 16Wx1
UV Lamp Emission of 253.7 nanometers for most efficient decontamination
Blower Built-in centrifugal blower; Speed adjustable.
Power Supply AC220±10%, 50/60Hz; 110V±10%, 60Hz
Consumption 400W 400W 500W 500W
Material Exterior Cold-rolled steel with anti-bacteria powder coating.
Interior Compact laminate board with good acid and alkali resistance function
Work Table Chemical resistant phenolic resin
Standard Accessories UV lamp x2, LED lamp, Water tap, Gas tap, Water sink, Base cabinet, 2pc waterproof sockets, Water supply flow control valve, Gas supply flow control valve
Total load of 2 waterproof sockets: 500W
10m PVC aluminum foil composite exhaust duct, pipe strap x2 (Duct is retractable and can be cut freely)
Optional Accessories Active carbon filter/HEPA filter
Gross Weight 286kg 317kg 350kg 400kg
Shipping Size (WxDxH)(mm) Main Body 1190x990x1690 1390x990x1690 1690x990x1690 1990x990x1690
Base Cabinet 1190x990x900 1390x990x900 1690x990x900 1990x990x900
Shipping Volume 3.1m³ 3.6m³ 4.3m³ 5.1m³

Reviews

There are no reviews yet.

Be the first to review “Ducted Fume Hood”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsDucted Fume Hood removeAGD Erma EL-120 ELectrolyte Analyzer removeSugentech Inclix (POCT) Immunoassay Analyzer removeAlcohol Pad Per Pack removeTest Strip for ApexBio HemoSmart Gold Hemoglobin Meter removeMotic BA210 Series Biomedical Microscope remove
NameDucted Fume Hood removeAGD Erma EL-120 ELectrolyte Analyzer removeSugentech Inclix (POCT) Immunoassay Analyzer removeAlcohol Pad Per Pack removeTest Strip for ApexBio HemoSmart Gold Hemoglobin Meter removeMotic BA210 Series Biomedical Microscope remove
Image
SKUSF1033560130127-39SF1033560084-125SF1033560084-89SF1033560084-64SF1033560084-30SF1033560084-78
Rating
Price

$0.00

$0.00

$0.00

$4.25

$9.50

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad FMH (A) series ducted fume hood is designed as a negative pressure ventilation system that ensures the safety of operators and the laboratory environment. It works by drawing room air inward through the front opening of the hood and continuously ventilating it with an extraction blower. This prevents the spread of contaminated fumes, vapors, toxic gases, aerosols, and corrosive substances that may be generated during experiments. Furthermore, an optional active carbon filter can purify the polluted air before it is exhausted through the duct, thereby protecting the outdoor environment as well.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Electrolyte Analyzer ERMA EL-120 is ideal for medium to high volume Laboratories and Hospitals . It offers reliable, automated samples handling and work flow offences . It also allows measurement of specific ions, accurately and precisely . This supports fast diagnosis of critically ill patients and reduces the risks of patient discomfort associated with repeated sampling Precise & Accurate Results Economical to use Large Touchscreen Display with Graphical User Interface. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock INCLIX™ is an immunochromatographic analyzer providing immediate point-of-care testing (POCT) at patient care settings or clinical laboratories. It facilitates automatic detection of various biomarkers for cardiovascular disease, infectious disease, cancer, diabetes, allergy, and etc. with high accuracy and sensitivity. INCLIX™ analyzer is a compact, easy-to-use and cost-effective multi-parameter POCT instrument and its unique user friendly software provides an efficient data management system. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock Alcohol Pad (70% Isopropyl Alcohol Pre Pad, Alcohol Cleansing Swab). Clean the required area. Discard after single use. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In Stock Twenty Five (25) Test Strip per Pack

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock The BA210 series is a line of basic biological microscopes manufactured by Motic. The unit is equipped with Motic Infinity Optics (CCIS®, offering quality performance in the fields of education and training. The device features a coaxial coarse and fine housing with a quadruple reverse-mounted nose piece. Its contrast methods, such as phase contrast, polarization and dark field, are easily performed through optional accessories. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Ducted Fume Hood Features:
  1. UV lamp for sterilization.
  2. Resistant to weak acid and alkali.
  3. Adjustable air speed: 3 levels.
  4. Manual or motorized front window, height adjustable.
  5. Microprocessor control system, LCD display.
  6. With memory function in case of power-failure.
  7. New design, with a liquid collection tank behind the backpanel to collect the waste liquid generated during the experiment and reduce pollution.
  8. Front panel with bypass Grille, Sash air foil and bypass system achieve function of Air supplement. Meets North American fume hood design standards.
 
Product Data
  • External Size : 3ft / 4ft / 5ft / 6ft
  • Maximum Opening : 520mm
  • Work Surface Height : 850mm
  • Airflow Velocity : Adjustable 0.3~0.8 m/s
  • Exhaust Duct : Φ300mm PVC (Standard Length: 10 meters)
 
Ducted Fume Hood Specifications:
Model FMH-1000DA FMH-1200DA FMH-1500DA FMH-1800DA
FMH-1000DA(II) FMH-1200DA(II) FMH-1500DA(II) FMH-1800DA(II)
External Size (WxDxH)(mm) 1040x800x2200 1240x800x2200 1540x800x2200 1840x800x2200
Internal Size (WxDxH)(mm) 820x670x730 1020x670x730 1320x670x730 1620x670x730
Front Window Manual (FMH-DA series),  Motorized (FMH-DA(II) series) 5mm toughened glass; Height adjustable.
Work Surface Height 850mm
Max Opening 520mm
Air Velocity 0.3~0.8m/s
Sound Emission ≤68dB
Exhaust Duct PVC, Standard Length: 10 meters.
Φ300mm
LED Lamp 8Wx1 12Wx1 16Wx1 16Wx1
UV Lamp Emission of 253.7 nanometers for most efficient decontamination
Blower Built-in centrifugal blower; Speed adjustable.
Power Supply AC220±10%, 50/60Hz; 110V±10%, 60Hz
Consumption 400W 400W 500W 500W
Material Exterior Cold-rolled steel with anti-bacteria powder coating.
Interior Compact laminate board with good acid and alkali resistance function
Work Table Chemical resistant phenolic resin
Standard Accessories UV lamp x2, LED lamp, Water tap, Gas tap, Water sink, Base cabinet, 2pc waterproof sockets, Water supply flow control valve, Gas supply flow control valve
Total load of 2 waterproof sockets: 500W
10m PVC aluminum foil composite exhaust duct, pipe strap x2 (Duct is retractable and can be cut freely)
Optional Accessories Active carbon filter/HEPA filter
Gross Weight 286kg 317kg 350kg 400kg
Shipping Size (WxDxH)(mm) Main Body 1190x990x1690 1390x990x1690 1690x990x1690 1990x990x1690
Base Cabinet 1190x990x900 1390x990x900 1690x990x900 1990x990x900
Shipping Volume 3.1m³ 3.6m³ 4.3m³ 5.1m³
Electrolyte Analyzer ERMA EL-120 is ideal for medium to high volume Laboratories and Hospitals . It offers reliable, automated samples handling and work flow offences . It also allows measurement of specific ions, accurately and precisely . This supports fast diagnosis of critically ill patients and reduces the risks of patient discomfort associated with repeated sampling Precise & Accurate Results Economical to use Large Touchscreen Display with Graphical User Interface. Features:
  • Parameters: Na+,K+,Cl-, iCa++ / Li
  • It works on ISE principle
  • Sample Type: Whole blood, Serum, Plasma, Urine
  • Low reagent consumption
  • Sample requirement is only 90ul
  • 60 samples per hour
  • Automatic two point calibration after 4hrs and one point calibration with each sample analysis
  • Air bubble detection
  • Track reagents consumption and provides alerts
  • For low reagent volume
  • Precision testing facility to get CV and SD
  • Trilevel Quality Control with LJ plots of last 30days
  • Low aspiration volume
  • Fast sample processing
  • Accurate and Precise results
Technical Specifications:
Parameters Na+, K+, Cl– /Ca++
Principle Ion Selective Electrode (ISE)
Sample Type Analyses whole blood, serum, plasma and urine
Sample Volume ≤100 µL
Analysis Time ≤60 seconds
Throughout ≤60 samples per hour
Data Link Serial (RS232)
External Interface USB (Keyboard, Mouse)
Operating Condition 10° C to 35° C, Relative Humidity up to 85%
Storage Condition Temp: 10° C to 40° C
Relative Humidity up to 85% non- condensing
Power Supply 100 to 240 VAC ±10%, 50Hz
Dimensions 395 x 260 x 375 mm
Weight 7.5 kg
 
Click Here To Download Catalogue
INCLIX™ is an immunochromatographic analyzer providing immediate point-of-care testing (POCT) at patient care settings or clinical laboratories. It facilitates automatic detection of various biomarkers for cardiovascular disease, infectious disease, cancer, diabetes, allergy, and etc. with high accuracy and sensitivity. INCLIX™ analyzer is a compact, easy-to-use and cost-effective multi-parameter POCT instrument and its unique user friendly software provides an efficient data management system. Features: • Good accuracy owning to superior CMOS sensor & our own Algorism • 10,000 test results data storage • Instrument Check by Reference Kit • Remote Support available (when connected via Internet) • Built-in Thermal Printer and Barcode Scanner • Data export to USB(PDF, Excel), Email and LIS • Storage Temperature of Test Cassette & Buffer : Room temperature, 2 ~ 30 ℃ • Shelf Life of Test Cassette & Buffer : 24 months  
Click Here To Download Catalogue
 
Alcohol Pad (70% Isopropyl Alcohol Pre Pad, Alcohol Cleansing Swab). Clean the required area. Discard after single use. Size and packing of Medical Alcohol pad:
  • Pad Size: Unfolded: 30 x 60 mm (other size can be request ).
  • Folded: 30x30 mm, 30 x 35mm,can be 2ply or 4ply ( other size, ply can be request ).
  • Aluminum Package: 60 x 50 mm , 50 x 50mm approximate ( other size can be request ).
  • Packing: 100/200 pcs per inner box, 50/ 100 boxes per carton(packing can be request).
Use of Medical Alcohol pad:
  • For cleaning prior to injection or to disinfect the hurted skin for family and medical treatment organization use.
  • For preparation and immediate disinfection of skin, wound area orr Instrument and utensil.
Notice of Medical Alcohol pad:
  • Not for eyes;
  • keep out of reach of children;
  • For external use only;
  • please stop using if you feel allergic or amyctic
Materials - Non-Woven Fabric
Trademark - OEM/ODM
Specification - CE&ISO13485
   
Twenty Five (25) Test Strip per PackThe BA210 series is a line of basic biological microscopes manufactured by Motic. The unit is equipped with Motic Infinity Optics (CCIS®, offering quality performance in the fields of education and training. The device features a coaxial coarse and fine housing with a quadruple reverse-mounted nose piece. Its contrast methods, such as phase contrast, polarization and dark field, are easily performed through optional accessories. Technical applications: Biomedical Type: Optical Observation technique: Dark field Magnification: 4 unit, 10 unit, 40 unit, 100 unit  
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare