Ducted Fume Hood
$0.00
Shipped From Abroad
FMH (A) series ducted fume hood is designed as a negative pressure ventilation system that ensures the safety of operators and the laboratory environment. It works by drawing room air inward through the front opening of the hood and continuously ventilating it with an extraction blower. This prevents the spread of contaminated fumes, vapors, toxic gases, aerosols, and corrosive substances that may be generated during experiments. Furthermore, an optional active carbon filter can purify the polluted air before it is exhausted through the duct, thereby protecting the outdoor environment as well.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
Ducted Fume Hood Features:
- UV lamp for sterilization.
- Resistant to weak acid and alkali.
- Adjustable air speed: 3 levels.
- Manual or motorized front window, height adjustable.
- Microprocessor control system, LCD display.
- With memory function in case of power-failure.
- New design, with a liquid collection tank behind the backpanel to collect the waste liquid generated during the experiment and reduce pollution.
- Front panel with bypass Grille, Sash air foil and bypass system achieve function of Air supplement. Meets North American fume hood design standards.
Product Data
- External Size : 3ft / 4ft / 5ft / 6ft
- Maximum Opening : 520mm
- Work Surface Height : 850mm
- Airflow Velocity : Adjustable 0.3~0.8 m/s
- Exhaust Duct : Φ300mm PVC (Standard Length: 10 meters)
Ducted Fume Hood Specifications:
Quick Comparison
Settings | Ducted Fume Hood remove | Hawksley 1400 Haematocrit Centrifuge remove | 8 Bucket Centrifuge remove | Skyla Hi POC Clinical Chemistry Analyzer remove | Erma B-111 Bilirubin Meter remove | Plastic Urine Container Per Pack remove | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Name | Ducted Fume Hood remove | Hawksley 1400 Haematocrit Centrifuge remove | 8 Bucket Centrifuge remove | Skyla Hi POC Clinical Chemistry Analyzer remove | Erma B-111 Bilirubin Meter remove | Plastic Urine Container Per Pack remove | ||||||||||||||
Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ||||||||||||||
SKU | SF1033560130127-39 | SF1033560084-118 | SF1033560084-114 | SF1033560060-2 | SF1033560084-6 | SF1033560084-106 | ||||||||||||||
Rating | ||||||||||||||||||||
Price |
| $690.00 | $72.50 |
| $715.00 | $8.20 | ||||||||||||||
Stock | ||||||||||||||||||||
Availability | ||||||||||||||||||||
Add to cart | ||||||||||||||||||||
Description | Shipped From Abroad
FMH (A) series ducted fume hood is designed as a negative pressure ventilation system that ensures the safety of operators and the laboratory environment. It works by drawing room air inward through the front opening of the hood and continuously ventilating it with an extraction blower. This prevents the spread of contaminated fumes, vapors, toxic gases, aerosols, and corrosive substances that may be generated during experiments. Furthermore, an optional active carbon filter can purify the polluted air before it is exhausted through the duct, thereby protecting the outdoor environment as well.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| In stock
| In stock
| Shipped from Abroad The skyla Hi POC Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results.The use of skyla Hi in the management of diabetes enables better access to testing and rapid clinical decision making, discussion,and implementation of optimized treatment. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped From Aboard
The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.
Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
| ||||||||||||||
Content | Ducted Fume Hood Features:
Product Data
Ducted Fume Hood Specifications: | The Hawksley Haematospin 1400 Centrifuges are built in the UK and are made from durable and high-quality components. These centrifuges are ideal for veterinary laboratories and practices specifically designed to produce reliable and accurate results on blood and urine. One of the main features of this centrifuge is that it takes both 2ml microtubes and 75mm microhaematocrits. The classic design of these centrifuges is used worldwide with guaranteed support for all servicing and parts.
Technical specifications:
Click Here To Download Catalogue | 800-1 electric centrifuge is widely used in hospitals, chemical and Biological Chemistry Laboratory for serum, plasma, immune qualitative analysis experiment. Has beautiful shape, large capacity, small volume, complete function. Its performance is stable, the speed is adjustable and can automatically adjust the balance, low temperature, high efficiency and wide applicability and advantages.
Technical Specifications:
Click Here To Download Catalogue | skyla Hi Analyzer enables better access to testing and rapid clinical decision making, discussion, and implementation of optimized treatment. To get the result, only prepare <1 μl fingertips blood or venous blood (depends on test item) without pretreatment with easy steps and then read the result after 6 mins. The device allows two specimens be tested in one run and provides fully automatic procedures from checking the validity of cartridge to printing the results.
Reagent Kit
Main SpecificationPrinciple
Turbidimetric Method / Biochemistry
Device
Testing Time
5~20 minutes (depends on test items)
Display and Interface
5″ TFT color touch screen LCD
Memory Capacity
50,000 test results
Dimension of Analyzer
270 x 188 x 148 mm
Weight of Analyzer
1.7 kg
Dimension of Printer Module
134 x 100 x 82.7 mm
Weight of Printer Module
0.37 kg
Power Supply
100~240 volts AC, 50-60Hz
Data Transmission
USB 2.0*4 / USB 3.0*1 / RS232*1 / RJ45*1 / Wi-Fi (optional)
Reagent and SamplesSamples
Fingertips blood or venous blood
Samples Volume
0.8 ~ 30 μL (depends on test item)
Storage Temperature (Reagent)
2 ~ 8˚C
HumidityRelative humidity < 95% (Non-condensing)
| The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric
analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.
Feature
|
| ||||||||||||||
Weight | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||
Dimensions | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||
Additional information |
Reviews
There are no reviews yet.