ECROSKHIM PE-5300VI Spectrophotometer
Ask for Price$0.00
Shipped From Abroad
PE-5300VI spectrophotometer is intended for measuring the transmittance factor and absorbancy of liquids (including the biological ones) for the purpose of determining the components dissolved in them as well as for measuring the transmittance factor and absorbancy of solid and liquid samples of various origins.
Delivery & Availability:
Typically 14-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
Description
PE-5300VI spectrophotometer is intended for measuring the transmittance factor and absorbancy of liquids (including the biological ones) for the purpose of determining the components dissolved in them as well as for measuring the transmittance factor and absorbancy of solid and liquid samples of various origins.
Technical specifications:
– Spectral range, nm – 325-1000
– Separable spectral range, nm – 4
– Range of measurement:
a) range of measurement of absorbancy, B – 3.000 to 0.000
b) range of measurement of spectral factors of direct transmission, %T – 0.0 до 100.0
– Optical source – W-lamp
– USB-B cable for connection to a PC
– Overall dimensions, (LxWxH), not more than, mm – 440х320х175.
– Weight, not more than, kg – 8.5
– Power consumption, W – 25
– Supply voltage, V – 85-250
The standard equipment of the spectrophotometer includes:
1. PE-5300VI spectrophotometer with holder for 3 cells (RUS standard, width – 24mm, path length – to 100mm)
2. CD with software
complete set of reference light filters (4 filters)
3. Glass cuvettes, RUS standard 10x24mm (4 pcs.)
4. Dust cover
5. USB-A – USB-B cable for connection to a PC
6. Spare halogen bulb
7. Operating manual and Data sheet
PE-5300VI spectrophotometer surpasses its counterparts such as UNICO 1200 (1201), LEKI SS1104, PE-5300V, KFK-3 in a number of metrological and operational characteristics.
Features:
Warranty period – 3 years
Manual setting of wave length
Manual compensation of dark current
Computer software with the possibility of automatic update via the Internet
Quick Comparison
ECROSKHIM PE-5300VI Spectrophotometer remove | IISM VPism-C (Compact Type) Vein Probe remove | Eppendorf Minispin Centrifuge remove | Alcohol Pad Per Pack remove | Erma B-111 Bilirubin Meter remove | Skyla HB1 POC Clinical Chemistry Auto Analyzer remove | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Name | ECROSKHIM PE-5300VI Spectrophotometer remove | IISM VPism-C (Compact Type) Vein Probe remove | Eppendorf Minispin Centrifuge remove | Alcohol Pad Per Pack remove | Erma B-111 Bilirubin Meter remove | Skyla HB1 POC Clinical Chemistry Auto Analyzer remove | ||||||||||
Image | ||||||||||||||||
SKU | SF10335601227 | SF1033560090-1 | SF1033560084-116 | SF1033560084-64 | SF1033560084-6 | SF1033560060-1 | ||||||||||
Rating | ||||||||||||||||
Price | Ask for Price | Ask for Price | Ask for Price | $4.25 | Ask for Price | Ask for Price | ||||||||||
Stock | ||||||||||||||||
Availability | ||||||||||||||||
Add to cart | ||||||||||||||||
Description | Shipped From Abroad
PE-5300VI spectrophotometer is intended for measuring the transmittance factor and absorbancy of liquids (including the biological ones) for the purpose of determining the components dissolved in them as well as for measuring the transmittance factor and absorbancy of solid and liquid samples of various origins.
Delivery & Availability:
Typically 14-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped from Abroad The iiSM VPism-C Vein Probe - Compact Unit is a compact, non-invasive infrared device to view blood vessels just beneath the skin. Includes a camera, touchscreen display, connector cable, power supply, camera stand, gooseneck arm, and instruction manual. Delivery & Availability: Typically 10 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
| In stock Alcohol Pad (70% Isopropyl Alcohol Pre Pad, Alcohol Cleansing Swab). Clean the required area. Discard after single use. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped From Aboard
The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.
Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped from Abroad The skyla HB1 Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results. The portable design of the clinical chemistry analyzer utilizes precision photometric measurement technology, combined with the single-use disposable reagent discs. The reagent disc contains a set of dry assay reagents that are used in the quantitative testing of various biomarkers in the blood sample. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | ||||||||||
Content |
Description
PE-5300VI spectrophotometer is intended for measuring the transmittance factor and absorbancy of liquids (including the biological ones) for the purpose of determining the components dissolved in them as well as for measuring the transmittance factor and absorbancy of solid and liquid samples of various origins.
Technical specifications:
- Spectral range, nm - 325-1000
- Separable spectral range, nm - 4
- Range of measurement:
a) range of measurement of absorbancy, B – 3.000 to 0.000
b) range of measurement of spectral factors of direct transmission, %T – 0.0 до 100.0
- Optical source – W-lamp
- USB-B cable for connection to a PC
- Overall dimensions, (LxWxH), not more than, mm - 440х320х175.
- Weight, not more than, kg – 8.5
- Power consumption, W - 25
- Supply voltage, V - 85-250
The standard equipment of the spectrophotometer includes:
1. PE-5300VI spectrophotometer with holder for 3 cells (RUS standard, width – 24mm, path length – to 100mm)
2. CD with software
complete set of reference light filters (4 filters)
3. Glass cuvettes, RUS standard 10x24mm (4 pcs.)
4. Dust cover
5. USB-A – USB-B cable for connection to a PC
6. Spare halogen bulb
7. Operating manual and Data sheet
PE-5300VI spectrophotometer surpasses its counterparts such as UNICO 1200 (1201), LEKI SS1104, PE-5300V, KFK-3 in a number of metrological and operational characteristics.
Features:
Warranty period – 3 years
Manual setting of wave length
Manual compensation of dark current
Computer software with the possibility of automatic update via the Internet
| The iiSM VPism-C Vein Probe - Compact Unit is a compact, non-invasive infrared device to view blood vessels just beneath the skin. Includes a camera, touchscreen display, connector cable, power supply, camera stand, gooseneck arm, and instruction manual. This handheld, portable device is lightweight and includes the touchscreen and camera with attached clip. The camera can be removed and handled by hand, or can clip to the touchscreen unit for a hands-free experience. The back of the device also has a kickstand, so that physicians can stand the device on its own. The VPism-C can also be mounted to an armrest, if a patient needs to be stationary, or attached to a SLism-F Specialized Light Source for patients with deeper vessels. This device can be a vital tool in providing accurate placement of injections or other vascular treatments, such as for varicose veins. The infrared video shows the location of the veins and capillaries in real time, as well as save images for further discussion or diagnosis. For patients who have difficult-to-find veins, this device will save them from incorrect or painful injection sites.
Features:
Probe Target: Subcutaneous blood vessels of various patients (including capillaries)
Probe Method: Non-invasive infrared technology
Probe Depth: Within 10 mm under the skin
Magnification Function: Up to 1X, 2X and 4X
Automatic Adjustment Function: Adjusts the brightness automatically based on the targeted vein
Specialized Light Function: Shows the veins more clearly by using the specialized light source
Operation Method: Easy to operate with touchscreen
Internal Battery Support: Continuous running time: 1.5 hours
Warranty: 1 year
Click Here To Download Catalogue | Powerful and user-friendly MiniSpin Centrifuge are small enough so that each workstation can be equipped with a “personal” centrifuge. The rotor, inner centrifuge lid, and lid latch are made of metal for maximum operation safety.
Features:
Click Here To Download Catalogue | Alcohol Pad (70% Isopropyl Alcohol Pre Pad, Alcohol Cleansing Swab). Clean the required area. Discard after single use.
Size and packing of Medical Alcohol pad:
Materials - Non-Woven Fabric
Trademark - OEM/ODM
Specification - CE&ISO13485
| The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric
analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.
Feature
| Skyla HB1 Clinical Chemistry Analyzer utilizes precision photometric measurement technology, combined with the single-use disposable reagent discs. The reagent disc contains a set of dry assay reagents that are used in the quantitative testing of various biomarkers in the blood sample. HB1 provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results. Only needs 200µl of blood (whole blood, serum or plasma is accepted.) and no sample preparation is required. All steps are designed automatically from checking the validity of reagent discs and cartridges to printing the results. Over 30 test parameters are allowed with fast analysis and results in 15 minutes. Internal Quality Control (IQC) with self-calibration of optical system, chemicals stability and interference alerts functions monitor and ensure the results with high accuracy.
Available Test Panels
Click Here To Download Catalogue | ||||||||||
Weight | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||
Dimensions | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||
Additional information |
|
Reviews
There are no reviews yet.