The Kenmak H-250 Patient Transfer and Consultation Chair is a convertible, tilt‑in‑space chair that transforms from a flat, stretcher-like position into an upright chair. Weighing approximately 56 kg and supporting up to 250 lbs, it provides a no‑lift solution for safe patient transfers and early mobilization in healthcare settings.
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
The H-250 Patient Transfer and Consultation Chair is a versatile, convertible seating solution designed specifically for safe and efficient patient transfers and consultations in clinical, hospital, and home care settings. With its innovative tilt‑in‑space functionality and no‑lift design, the H-250 easily converts from a stretcher-like prone position to an upright chair, enabling a single caregiver to perform transfers without compromising patient safety or comfort.
Key Features:
-
Convertible Design:
- Transforms seamlessly from a flat (stretcher) position to an upright, mobile chair, supporting early patient mobilization and safe lateral transfers.
- Tilt‑in‑space capability allows unlimited repositioning, which helps improve blood circulation and reduce the risk of pressure ulcers.
-
Ergonomic Construction:
- Contoured seating with high-density foam cushioning and adjustable headrest (up to 7 inches/18 cm) for enhanced patient comfort.
- Designed to accommodate a wide range of patient heights (approximately 127–198 cm) while maintaining proper support.
-
Robust & Lightweight:
- Weighs approximately 56 kg (123 lbs) with a durable steel or aluminum frame, ensuring longevity and ease of handling.
- Maximum patient weight capacity of up to 250 lbs (113 kg) provides safe support for a variety of users.
-
User-Friendly Operation:
- Simple electronic or manual controls allow quick adjustments of the chair’s height (ranging from 53–60 inches or 135–152 cm in chair mode) and leg positioning.
- Designed to be operated by a single caregiver, reducing the physical strain associated with patient transfers.
-
Enhanced Safety Features:
- Secure locking casters and integrated side rails add stability and protection during transfers and repositioning.
- Provides a no-lift solution that minimizes the risk of injury to both patients and caregivers.
Specifications (Approximate):
- Overall Dimensions (Prone Mode):
- Length: 72.5–80 inches (184–203 cm)
- Height: 27 inches (68 cm)
- Overall Dimensions (Chair Mode):
- Height: 53–60 inches (135–152 cm)
- Width: 24 inches (61 cm)
- Seat Width: Approximately 17 inches (43 cm)
- Headrest Adjustable Height: 7 inches (18 cm)
- Weight: ~56 kg (123 lbs)
- Maximum Patient Weight: 250 lbs (113 kg)
Additional information
Weight | 56 kg |
---|
Quick Comparison
Settings | H-250 Patient Transfer and Consultation Chair remove | Instrument Tray remove | Syringe Needle Destroyer remove | Standiometer remove | Stainless Steel Hospital Two Step Stool remove | OPTIKA B-382PL-ALC Binocular Brightfeld Microscope remove | ||
---|---|---|---|---|---|---|---|---|
Name | H-250 Patient Transfer and Consultation Chair remove | Instrument Tray remove | Syringe Needle Destroyer remove | Standiometer remove | Stainless Steel Hospital Two Step Stool remove | OPTIKA B-382PL-ALC Binocular Brightfeld Microscope remove | ||
Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ||
SKU | SF1033560084-199 | SF1033560084-206 | SF1033560084-219 | SF1033560084-204 | SF1033560098-13 | |||
Rating | ||||||||
Price |
| $6.90 | $157.00 | $64.00 | $27.00 |
| ||
Stock | ||||||||
Availability | ||||||||
Add to cart | ||||||||
Description | Shipped From Abroad
The Kenmak H-250 Patient Transfer and Consultation Chair is a convertible, tilt‑in‑space chair that transforms from a flat, stretcher-like position into an upright chair. Weighing approximately 56 kg and supporting up to 250 lbs, it provides a no‑lift solution for safe patient transfers and early mobilization in healthcare settings.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| In stock
| In stock
Needle destruction destroy the needle immediately following its use. Needle destruction are an absolute necessity in developing parts of the world to prevent the reuse of needles and the spread of bloodborne pathogens. They are NOT a good alternative, however, for hospital use in the developed parts of the world. Needle destruction are products that bend, cut, or destroy the needle. This are distinctly different from needle destroyer that send an arc of electricity to vaporize and melt the needle.
| In stock
| In stock
Features:
| Shipped from Abroad The OPTIKA B-380 is an educational and laboratory microscope for routine applications. Dye-cast frame, with high stability and ergonomy, for transmitted light observation. Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | ||
Content | The H-250 Patient Transfer and Consultation Chair is a versatile, convertible seating solution designed specifically for safe and efficient patient transfers and consultations in clinical, hospital, and home care settings. With its innovative tilt‑in‑space functionality and no‑lift design, the H-250 easily converts from a stretcher-like prone position to an upright chair, enabling a single caregiver to perform transfers without compromising patient safety or comfort. Key Features:
Specifications (Approximate):
|
| Needle destruction destroys the needle immediately following its use. Needle destruction are an absolute necessity in developing parts of the world to prevent the reuse of needles and the spread of bloodborne pathogens. They are NOT a good alternative, however, for hospital use in the developed parts of the world. Needle destruction are products that bend, cut, or destroy the needle. This are distinctly different from needle destroyer that send an arc of electricity to vaporize and melt the needle.
Features:
|
| Features:
| Observation mode: Brightfield.
Head: Binocular, 30° inclined, 360° rotating (when ALC cable is unplugged).
Interpupillary distance: Adjustable between 48 and 75 mm.
Dioptric adjustment: On the left eyepiece tube.
Eyepieces: WF10x/20 mm, high eye-point and secured by screw.
Nosepiece: Quintuple revolving nosepiece, rotation on ball bearings.
Objectives:
N-PLAN 4x/0.10
N-PLAN 10x/0.25
N-PLAN 40x/0.65
N-PLAN 100x/1.25 (Oil/Water)
All with anti-fungus treatment.
Specimen stage: Double layer rackless mechanical stage, 150×139 mm, 75×33 mm X-Y range.
Focusing: Coaxial coarse (adjustable tension) and fine focusing mechanism with limit stop to prevent the contact between objective and specimen. Condenser: Abbe N.A. 1.25, with objective-coded iris diaphragm, focusable and centerable.
Illumination (Fixed Koehler type): X-LED3 with white 3.6 W LED (6,300K) and brightness control. ALC system. Multi-plug 100-240Vac/6Vdc external power supply.
Click Here To Download Catalogue | ||
Weight | 56 kg | N/A | N/A | N/A | N/A | N/A | ||
Dimensions | N/A | N/A | N/A | N/A | N/A | N/A | ||