Description Shipped From Abroad
Features:
50KW single power module in 3U
N+1or N+X parallel redundancy for power guarantee
Supports horizontal expansion by 1+1 cabinet paralleloperation.
Hot-swappable modular design decreases MTTR
High scalability
Built-in maintenance bypass switch for easy maintenance without interruptible
High efficiency double conversion online UPS
Flexible battery configuration and adjustable charging current
High overload capability
Power walk-in function
Built-in dynamic password protection
Built-in ultra communication slot
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Features:
Optional 7 ” touch LCD
Online double-conversionDSP technology guarantees high reliability
True galvanic isolation transformer designControl designed to withstand all kinds of loads
Intelligent battery management to prolong battery lifecycle
Redundant fan design and independent ventilation enhance durable operation under harsh environment
Adiustable battery numbers
Accept dual-mains input
Parallel operation with up to 4 units ( option )
Variety of communication options available
Reverse phase frequency operation and supportsnon-neutral input
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Features:
Intelligent CPU control
Automatic power on when the the main power recovers
Cold start function
Power off charging function
USB/RS232/RJ-11/RJ-45 communication port (optional)
Offering LED and LCD panels for selection
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content Features:
50KW single power module in 3U
N+1or N+X parallel redundancy for power guarantee
Supports horizontal expansion by 1+1 cabinet paralleloperation.
Hot-swappable modular design decreases MTTR
High scalability
Built-in maintenance bypass switch for easy maintenance without interruptible
High efficiency double conversion online UPS
Flexible battery configuration and adjustable charging current
High overload capability
Power walk-in function
Built-in dynamic password protection
Built-in ultra communication slot
Specifications:
MODEL
RM Plus 300K
RM Plus 350K
RM Plus 400K
RM Plus 500K
Phase
3 Phase in / 3 Phase out
Cabinet Capacity*
300 KW
350 KW
400KW
500KW
Battery Type
Extemal Battery
One Power Module Capacity
50KVA/50KW
Max. Power Module No.
6
7
8
10
INPUT
Nominal Voltage
3×380/400/415 VAC (3Ph+N)
Voltage Range
’-20%~+15%
Nominal Frequency
50/60Hz(Auto Sensing)
Frequency Range
40Hz~70Hz
Power Factor
>0.99 @100% Load, >0.98@50% Load
Harmonic Distortion (THDi)
<4% @ 100% load
OUTPUT
Nominal Voltage
3×380/400/415 VAC (3Ph+N)
Voltage Regulation(Steady State)
≤ ±1% Typical (balanced load); ~≤ ±2% Typical (unbalanced load)
Nominal Frequency
50/60Hz
Frequency Range(Synchronized)
46Hz~54Hz or 56Hz~64Hz
Overload Capability
1 hour for ≤110%,10 mins for 111%~125%,1 min for 126%~150% and 200ms for >150%
Haronic Distortion
≤2% THD (Linear Load); ≤4% THD (Non-linear Load)
Eficiency
95.50%
BATTERY / CHARGER
Nominal Voltage
‘+/- 192V~+/- 240V (Selectable)
Maximum Voltage
’+/- 240V (12V×40PCS)
Minimum Voltage
‘+/- 192V(12V×32PCS)
Floating Charge Voltage
2.28V/Cell (2.25~2.33 Selectable)
Boost Charging Voltage
2.35V/Cell
Temperature Compensation
Yes
Maximum Charging Current
(Per Power Module)
12A (Adjustable)
PHYSICAL
Cabinet Dimension (DxWxH)mm
1065x600x2000
1065x600x2000
1065x1000x2000
1065x1000x2000
Net Weight (Kg)
545
654
932
1020
Power Module (PM-50) Net Weight
44KGS
ENVIRONMENT
Operating Temperature
0~40℃
Relative Humidity
0~95% non-condensing
Altitude*
<1000m for Nominal power
IP Protection
IP 20
MANAGEMENT
Smart RS-232/USB
Supports Windows⑧ Family, Linux and MAC
Optional SNMP
Power management from SNMP manager and web browser
STANDARDS
Safety
IEC/EN 62040-1
EMC
IEC/EN 62040-2 Category C3
Features:
OPzV Tubular Gel Battery ( solid-state) 60AH-3000AH
Voltage class: 12V/2V
Capacity range: 60Ah~3000Ah
OPzV batteries offer high capacity reserve power and true deep cycling performance. With a design life of 20 years and a maintenance-free operation,
OPzV battery are perfect for regions with an unstable supply of electricity. OPzV battery are also completely spill-proof, which makes them safe to install anywhere,
even in remote environments with minimal supervision.
Technical Specifications
Model
Nominal Voltage
Capacity
Dimension
Terminal
C10/1.80VPC (Ah)
Length
Width
Height
Total Height
(V)
mm
mm
mm
mm
OPzV6-200
6
200
322
177.5
226
231
F16(M8)
F14(M8)
OPzV12-60
12
60
260
169
211
216
F11(M6)
OPzV12-80
12
80
328
172
215
220
F12(M8)
OPzV12-100
12
100
407
177
225
225
F12(M8)
OPzV12-120
12
120
483
170
241
241
F12(M8)
OPzV12-140
12
140
532
207
214
219
F12(M8)
OPzV12-160
12
160
532
207
214
219
F12(M8)
OPzV12-180
12
180
522
240
219
224
F10(M8)
OPzV12-200
12
200
521
268
220
225
F14(M8)
OPzV2-200
2
200
103
206
355
390
F10(M8)
OPzV2-250
2
250
124
206
355
390
F10(M8)
OPzV2-300
2
300
145
206
355
390
F10(M8)
OPzV2-350
2
350
124
206
470
505
F10(M8)
OPzV2-420
2
420
145
206
470
505
F10(M8)
OPzV2-500
2
490
166
206
470
505
F10(M8)
OPzV2-770
2
770
210
254
470
505
F10(M8)
OPzV2-600
2
600
145
206
645
680
F10(M8)
OPzV2-800
2
800
191
210
645
680
F10(M8)
OPzV2-1000
2
1000
233
210
645
680
F10(M8)
OPzV2-1200
2
1200
276
210
645
680
F10(M8)
OPzV2-1500
2
1500
275
210
795
830
F10(M8)
OPzV2-2000
2
2000
399
214
770
805
F10(M8)
OPzV2-2500
2
2500
487
212
770
805
F10(M8)
OPzV2-3000
2
3000
576
212
770
805
F10(M8)
Features:
Optional 7 ” touch LCD
Online double-conversionDSP technology guarantees high reliability
True galvanic isolation transformer designControl designed to withstand all kinds of loads
Intelligent battery management to prolong battery lifecycle
Redundant fan design and independent ventilation enhance durable operation under harsh environment
Adiustable battery numbers
Accept dual-mains input
Parallel operation with up to 4 units ( option )
Variety of communication options available
Reverse phase frequency operation and supportsnon-neutral input
Specifications
MODEL
LF33 10K
LF33 20K
LF33 30K
LF33 40K
LF33 60K
LF33 80K
LF33 100K
LF33 120K
LF33 160K
LF33 200K
CAPACITY
10KVA /8KW
20KVA /16KW
30KVA /24KW
40KVA /32KW
60KVA /48KW
80KVA /64KW
100KVA /80KW
120KVA /96KW
160KVA /128KW
200KVA /160KW
INPUT
Nominal Voltage
3 x 380VAC/400VAC (3Ph + N)
Acceptable Voltage Range
305VAC ~ 460VAC
Frequency
46-54Hzor56-64Hz
INVERTER
Nominal Voltage
3 x 380VAC/400VAC (3Ph + N)
Precision
Stationary: ±1% Transitory: ±5% (load variations 100-0-100%)
Frequency
50/60 Hz synchronised ±1 % With mains absent ±0.1 Hz
Max. Synchronisation Speed
±1 Hz/s
Waveform
Pure Sinewave
Total Harmonic Distortion (THDv)
<2% (Linear Load) ; <5% (Non-linear Load)
Phase Displacement
120° ±1 % (balanced load); 120° ±2% (imbalances 50% of the load)
Dynamic Recovery Time
Restore to 90% of rated value in 3 cycles
Overload capacity
110% for 10min; 150% for 60sec; >160% for 200ms
Admissible Crest Factor
3:1
Admissible Power Factor
0.6-1 (inductive or capacitive)
Imbalance Output Voltage @ 100% Unbalanced Load
<1%
Current Limit
High overload, short-circuit: RMS Voltage Limit; High Crest-Factor current: Peak Voltage Limit
STATIC BYPASS
Type
Solid state
Voltage
3 x 380VAC/400VAC (3Ph + N)
Frequency
50/60 Hz
Activation Criterion
Microprocessor control
Transfer Time
Zero
Admissible Overload
150% for 1 hour; 180% for 30sec; >200% for 200ms
Transfer to Bypass
Immediate, for overloads above 160%
Retransfer
Automatic after alarm clear
MAINTENANCE BYPASS
Type
Without interruption
Voltage
3 * 400V (3Ph + N)
Frequency
50/60 Hz
Overall Efficiency
Line Mode
90%
91%
92%
93%
Battery Mode
90%
91%
93%
93%
BATTERY & CHARGER
Battery Type and Numbers
12VDC * 32 pcs (29-32 pcs adjustable)
Nominal Battery Voltage
384 VDC (Based on 32pcs batteries)
Charging Method
CC/CV
Precision
±1%
Charging Current
Max.: 40 A
Charging Voltage
432 VDC (Based on 32pcs batteries)
PHYSICAL
Dimensions, D x W x H(mm)
656 x 405 x 817
656 x 405 x 941
840x432x1140
975x554x1286
1200x910x1680
1500x1140x1800
Net Weight (Kgs)
180
205
295
330
451
519
950
1350
Features:
True double-conversion
LCD screen auto-rotation with Rack position ( only for 10K-20K models)
DSP technology guarantees high performance
Output power factor 1
Support 1/1;3/1;3/3 Phase Adjustable
Active power factor correction in all phases
50HZ / 60HZ frequency converter mode
ECO mode operation for energy saving ( ECO)
Emergency power off function ( EPO)
Generator compatible
Supports dual AC inputs
3-stage extendable charging design for optimized battery performance
Adjustable battery numbers for long-run model
Supporting Parallel sharing of battery packs
Optional isolation transformer offers full isolation and complete common mode noise rejection
Support with SNMP,USB, RS232 communication
Technical Specifications
MODEL
33RM 10KL
33RM 15KL
33RM 20KL
33RM 30KL
33RM 40KL
33RM 60KL
CAPACITY
10KVA/10KW
15KVA/15KW
20KVA/20KW
30KVA/30KW
40KVA/40KW
60KVA/60KW
PHASE
3 Phase input / 3 Phase output
PARALLEL CAPABILITY
4 Max
INPUT
Nominal Voltage
3×380 VAC (3Ph+N)
Voltage Range
190-520 VAC (3 Phase) @ 50% load , 305-478 VAC (3 Phase) @ 100% load
Frequency Range
46-54 Hz or 56~64Hz
Power Factor
≥ 0.99 @ 100% load
OUTPUT
Output Voltage
3 x 360*/380/400/415 VAC (3Ph+N)
AC Voltage Regulation (Batt. Mode)
± 1%
Frequency Range (Synchronized Range)
46~54Hz or 56~64Hz
Frequency Range (Batt. Mode)
50 Hz ±0.1 Hz or 60 Hz ±0.1 Hz
Current Crest Ratio
3:1 (max.)
Harmonic Distortion
≤1 % THD (Linear Load), ≤3% THD (Non-linear Load)
Transfer Time
AC mode to Battery mode
zero
Inverter to Bypass
zero
Waveform (Batt. Mode)
Pure Sine Wave
Overload
AC Mode
100-110% for 60 min, 110-125% for 10 min, 125%~150% for 1 min; >150% immediately Protection
Battery Mode
100-110% for 60 min, 110-125% for 10 min, 125%~150% for 1 min; >150% immediately Protection
EFFICIENCY
AC Mode
95.5%
ECO Mode
98.5%
Battery Mode
94.5%
BATTERY
Battery Type
Depending on the applications
Numbers
20 pcs
32-40 pcs (Adjustable)
Charging Current (max.)
1A~ 12A (Adjustable)
1A~ 16A (Adjustable)
1A 〜18A (Adjustable)
Charging Voltage
±13.65 VDCx N (N=10)
±13.65VxN (N=16〜20)
PHYSICAL
Dimension, D * W * H (mm)
680*438*133 [3U]
797*438*176 [4U]
Net Weight (kgs)
27
30
40
45
ENVIRONMENT
Operation Temperture
0-40°C
Operation Humidity
0-95% and non-condersing
Noise Level
Less than 62dB @ 1 Meter
Less than 65dB @ 1 Meter
Less than 70dB @ 1 Meter
MANAGEMENT
Smart RS-232/USB
Supports Windows® Family, Linux and MAC
Optional SNMP
Power management from SNMP manager and web browser
Features:
Intelligent CPU control
Automatic power on when the the main power recovers
Cold start function
Power off charging function
USB/RS232/RJ-11/RJ-45 communication port (optional)
Offering LED and LCD panels for selection
Application:
Personal Computer
Printer
POS(Point of sales)Terminals
Security System
Fax Machine
Modem, WiFi Router
Technical Specifications:
Model
DP600
DP1000
DP1200
DP2000
DP3000
Capacity
600VA/360W
1000VA/600W
1200VA/720W
2000VA/1200W
3000VA/1800W
INPUT
Voltage
110/120VAA or 220/230/240VAC
Voltage Range
67-137VAC/135-275VAC
Frequency Range
50Hz Or 60Hz(Auto-Sensing)
OUTPUT
Output Voltage
110/120VAA or 220/230/240VAC
AC Voltage Regulation
± 10%
Frequency Range
(Batt. Mode)
50 HZ or 60 Hz ± 10%
Transfer Time
Typical 6-10 ms
Waveform
(Battery Mode)
Simulated Sine Wave
BATTERY
Battery Voltage
12V/7AH*1
12V/9AH*1
12V/7AH*2
12V/9AH*2
12V/7AH*4
Charge Time
8 hours up to 80-90%
PROTECTION
Full Protection
Auto Detection, discharge protection,output Short circuit, Over load, Battery low voltage protection
Communication Port
USB/RS232/RJ11/RJ45 (Optional)
Display
LED/LCD
Alarm
Battery Mode
Every 4 Seconds one beep
Low Battery Capacity
Every 1 Seconds one beep
Overload
Every 1 Seconds one beep
Fault
Keep beeping
ENVIRONMENT
Humidity
0-90% Rh @ 0-40℃ (Non-Condensing)
Noise Level
40dB
Dimension(mm)
320*90*140
330* 100*150
365*140*165
365*140*165
395*145*210
N.W.(kg)
5.2
6
10
12.6
21
Features:
Rated Power: 500W
Rated Capacity: 519 . 48wh
Standard Capacity: 3.7V/140400mah
Overload Protecion: 550W + 40W
AC Output: AC 110V+10%/60HZ 230V+10%/50HZ
Output Wave: Pure sine wave
USB Output: QC 18W*2
Type-c Output: PD 60W*2
Cigarret Lighter Output: 14V/8A
DC5525 Output: 14V/8A
Wireless Charging: 15W
Charging Input: 12-26 V/100W Max
WorkingTemperature: -10-40 °C
Weight(Net Weight): 6.8kg
Weight(With Accessories): 8.5kg
Dimension: 345*227*203mm
Applications:
Mammogram
Ultrasound Equipments
Radiology rooms
Reviews