100-110% for 60 min, 110-125% for 10 min, 125%~150% for 1 min; >150% immediately Protection
Battery Mode
100-110% for 60 min, 110-125% for 10 min, 125%~150% for 1 min; >150% immediately Protection
EFFICIENCY
AC Mode
95.5%
ECO Mode
98.5%
Battery Mode
94.5%
BATTERY
Battery Type
Depending on the applications
Numbers
20 pcs
32-40 pcs (Adjustable)
Charging Current (max.)
1A~ 12A (Adjustable)
1A~ 16A (Adjustable)
1A 〜18A (Adjustable)
Charging Voltage
±13.65 VDCx N (N=10)
±13.65VxN (N=16〜20)
PHYSICAL
Dimension, D * W * H (mm)
680*438*133 [3U]
797*438*176 [4U]
Net Weight (kgs)
27
30
40
45
ENVIRONMENT
Operation Temperture
0-40°C
Operation Humidity
0-95% and non-condersing
Noise Level
Less than 62dB @ 1 Meter
Less than 65dB @ 1 Meter
Less than 70dB @ 1 Meter
MANAGEMENT
Smart RS-232/USB
Supports Windows® Family, Linux and MAC
Optional SNMP
Power management from SNMP manager and web browser
Features:
OPzV Tubular Gel Battery ( solid-state) 60AH-3000AH
Voltage class: 12V/2V
Capacity range: 60Ah~3000Ah
OPzV batteries offer high capacity reserve power and true deep cycling performance. With a design life of 20 years and a maintenance-free operation,
OPzV battery are perfect for regions with an unstable supply of electricity. OPzV battery are also completely spill-proof, which makes them safe to install anywhere,
even in remote environments with minimal supervision.
Technical Specifications
Model
Nominal Voltage
Capacity
Dimension
Terminal
C10/1.80VPC (Ah)
Length
Width
Height
Total Height
(V)
mm
mm
mm
mm
OPzV6-200
6
200
322
177.5
226
231
F16(M8)
F14(M8)
OPzV12-60
12
60
260
169
211
216
F11(M6)
OPzV12-80
12
80
328
172
215
220
F12(M8)
OPzV12-100
12
100
407
177
225
225
F12(M8)
OPzV12-120
12
120
483
170
241
241
F12(M8)
OPzV12-140
12
140
532
207
214
219
F12(M8)
OPzV12-160
12
160
532
207
214
219
F12(M8)
OPzV12-180
12
180
522
240
219
224
F10(M8)
OPzV12-200
12
200
521
268
220
225
F14(M8)
OPzV2-200
2
200
103
206
355
390
F10(M8)
OPzV2-250
2
250
124
206
355
390
F10(M8)
OPzV2-300
2
300
145
206
355
390
F10(M8)
OPzV2-350
2
350
124
206
470
505
F10(M8)
OPzV2-420
2
420
145
206
470
505
F10(M8)
OPzV2-500
2
490
166
206
470
505
F10(M8)
OPzV2-770
2
770
210
254
470
505
F10(M8)
OPzV2-600
2
600
145
206
645
680
F10(M8)
OPzV2-800
2
800
191
210
645
680
F10(M8)
OPzV2-1000
2
1000
233
210
645
680
F10(M8)
OPzV2-1200
2
1200
276
210
645
680
F10(M8)
OPzV2-1500
2
1500
275
210
795
830
F10(M8)
OPzV2-2000
2
2000
399
214
770
805
F10(M8)
OPzV2-2500
2
2500
487
212
770
805
F10(M8)
OPzV2-3000
2
3000
576
212
770
805
F10(M8)
Features:
Optional 7 ” touch LCD
Online double-conversionDSP technology guarantees high reliability
True galvanic isolation transformer designControl designed to withstand all kinds of loads
Intelligent battery management to prolong battery lifecycle
Redundant fan design and independent ventilation enhance durable operation under harsh environment
Adiustable battery numbers
Accept dual-mains input
Parallel operation with up to 4 units ( option )
Variety of communication options available
Reverse phase frequency operation and supportsnon-neutral input
50/60 Hz synchronised ±1 % With mains absent ±0.1 Hz
Max. Synchronisation Speed
±1 Hz/s
Waveform
Pure Sinewave
Total Harmonic Distortion (THDv)
<2% (Linear Load) ; <5% (Non-linear Load)
Phase Displacement
120° ±1 % (balanced load); 120° ±2% (imbalances 50% of the load)
Dynamic Recovery Time
Restore to 90% of rated value in 3 cycles
Overload capacity
110% for 10min; 150% for 60sec; >160% for 200ms
Admissible Crest Factor
3:1
Admissible Power Factor
0.6-1 (inductive or capacitive)
Imbalance Output Voltage @ 100% Unbalanced Load
<1%
Current Limit
High overload, short-circuit: RMS Voltage Limit; High Crest-Factor current: Peak Voltage Limit
STATIC BYPASS
Type
Solid state
Voltage
3 x 380VAC/400VAC (3Ph + N)
Frequency
50/60 Hz
Activation Criterion
Microprocessor control
Transfer Time
Zero
Admissible Overload
150% for 1 hour; 180% for 30sec; >200% for 200ms
Transfer to Bypass
Immediate, for overloads above 160%
Retransfer
Automatic after alarm clear
MAINTENANCE BYPASS
Type
Without interruption
Voltage
3 * 400V (3Ph + N)
Frequency
50/60 Hz
Overall Efficiency
Line Mode
90%
91%
92%
93%
Battery Mode
90%
91%
93%
93%
BATTERY & CHARGER
Battery Type and Numbers
12VDC * 32 pcs (29-32 pcs adjustable)
Nominal Battery Voltage
384 VDC (Based on 32pcs batteries)
Charging Method
CC/CV
Precision
±1%
Charging Current
Max.: 40 A
Charging Voltage
432 VDC (Based on 32pcs batteries)
PHYSICAL
Dimensions, D x W x H(mm)
656 x 405 x 817
656 x 405 x 941
840x432x1140
975x554x1286
1200x910x1680
1500x1140x1800
Net Weight (Kgs)
180
205
295
330
451
519
950
1350
Features:
Nomimal voltage: 12V
Rated Capacity: 5Ah ~ 250Ah
Operating temperature range: -15 ~ 45 ℃
The design life is 5 years
Using new special process sheet formula to improve the utilization of active material
Using high quality superfine glass fiberliquid-suction battery technology to exceed 99% gas recombination rate
High-strength ABS plastic battery slot and cover with features of compact structure, corrosion resistant, impact resistance and
anti-vibration and so on
Small internal impedance, excellent performance when high current discharge
Low self-discharge, wide operating temperature range
Using multiple sealing technologies to ensure no leakage, no acid mist escaping to keep safe and reliable
Using strict production process, unit voltage balance is strong
Free maintenance, without adding water rehydration
Technical Specifications
Model
Nominal Voltage
Capacity
Dimension LXWXH (mm)
Total Height
(mm)
Weight (KG)
Terminal
VL12-24
12
24
166
175
125
125
8
M6
VL12-28
12
28
166
175
125
125
9
M6
VL12-33
12
33
196
130
163
180
10
M6
VL12-35
12
35
197
130
163
180
10.5
M6
VL12-40
12
40
197
166
171
171
13.5
M6
VL12-44
12
44
196
166
171
171
13.5
M6
VL12-55
12
55
230
138
211
229
17.2
M6
VL12-65
12
65
350
166
179
179
22
M6
VL12-70
12
70
260
169
211
229
23
M8
VL12-80
12
80
260
169
211
229
24
M8
VL12-90
12
90
307
169
211
234
28
M8
VL12-100
12
100
331
173
213
233
32
M8
VL12-120
12
120
407
174
209
233
3, 8
M8
VL12-130
12
134
341
173
283
287
41
M8
VL12-150
12
150
484
171
241
241
46
M8
VL12-160
12
160
534
209
216
237
52
M8
VL12-180
12
180
530
209
216
237
56
M8
VL12-200
12
200
522
240
220
244
64
M8
VL12-230
12
230
520
268
220
240
72.5
M8
VL12-250
12
250
520
268
220
249
76
M8
Features:
60KW single power module in 3U
N+1or N+X parallel redundancy for power guarantee
Supports horizontal expansion by 1+1 cabinet paralleloperation.
Hot-swappable modular design decreases MTTR
High scalability
Built-in maintenance bypass switch for easy maintenance without interruptible
High efficiency double conversion online UPS
Flexible battery configuration and adjustable charging current
1 hour for ≤110%,10 mins for 111%~125%,1 min for 126%~150% and 200ms for >150%
Haronic Distortion
≤2% THD (Linear Load); ≤4% THD (Non-linear Load)
Eficiency
96%
BATTERY / CHARGER
Nominal Voltage
’+/- 192V~+/- 240V(Selectable)
Maximum Voltage
’+/- 240V (12V×40 PCS)
Minimum Voltage
‘+/-192V (12V×32 PCS)
Floating Charge Voltage
2.28V/Cell (2.25~2.33 Selectable)
Boost Charging Voltage
2.35V/Cell
Temperature Compensation
Yes
Maximum Charging Current
(Per Power Module)
18A(Adjustable)
PHYSICAL
Cabinet Dimension (DxWxH)mm
1100x600x1475
1100x600x1475
1100x600x2010
1100×600×2010
1065x1000x2000
1065×1000×2000
Net Weight (Kg)
308
352
516
654
932
1020
Power Module (PM-60) Net Weight
44KGS
ENVIRONMENT
Operating Temperature
0~40℃
Relative Humidity
0~95% non-condensing
Altitude*
<1000m for Nominal power
IP Protection
IP 20
MANAGEMENT
Smart RS-232/USB
Supports Windows⑧ Family, Linux and MAC
Optional SNMP
Power management from SNMP manager and web browser
STANDARDS
Safety
IEC/EN62040-1
EMC
IEC/EN 62040-2 Category C3
Description
HIGH INTELLIGENCE AND RELIABLE POWER SUPPLYIGBT Technology
Full microprocessor control with no-break static and manual bypasses.
Online double conversion technology (VFl) with isolation transformer on theinverter output.
Extremely high short-circuit current to ensure compatibility with the most diffificult transformer applications (lighting, drives and industrial processes) and an isolation transformer on the inverter output.
Compatibled with Watch & Save 3000 software as standard and can be remotely monitored using the Power NetGuard system from anywhere in the world.
SIMPLE TO INSTALL
Capability to install the UPS into any distribution system(neutral not required on rectifier input).
Capability to separate the rectifier/bypass power networks and to power them from two separate sources, without Galvanic isolation(Necessary on UPS without an output transformer
MAXIMUM BATTERY CARE
Battery deep discharge protection;
Temperature compensating charger;
Built-in automatic and manual battery test feature.
OTHER CHARACTERISTICS
0.8/0.9 power factor suitable for powering ICT and lndustrial loads.
BACK FEED protection: to avoid energy feeding back into the mains supply cause a fault occur.
MAXIMUM RELIABILITY AND AVAILABILITY
Connect up to 6 units in parallel or N+1 redundancy, even of different power ratings.
The UPS continue to work in parallel even if one of theinterconnecting communication cables is disconnected(CLOSED LOOP)
LOW CONSUMPTION LEVELS
LF33 Series UPS can achieve efficiencies >98% thanks to selectable Economy Mode which can be used in stable electrical environments to provide power supply continuity when the mains fail.
ADVANCE COMMUNICATION:
RS485/RS232/Dry Contact/SNMP(Optional)
Specifications
Model
10KVA
20KVA
30KVA
40KVA
60KVA
80KVA
100KVA
120KVA
160KVA
200KVA
250KVA
300KVA
400KVA
500KVA
600KVA
Capacity
8KW
16 KW
24 KW
32 KW
48 KW
64 KW
80 KW
96 KW
128 KW
160 KW
200KW
240KW
320KW
400KW
480KW
INPUT
Rated voltage
400 VAC Three-Phase
Voltage range
380/400/415VAC(+25%,Can be set through the LCD panel)
Frequency range
40-70Hz(Automatically select synchronization range according to grid frequency)
Range(HZ)
50±5%(±10%) Bypass synchronization tracking
Rectifying pulse number
6 pulse rectification
6/12 pulse rectification
12 pulse rectifier
Phase system
3φ4W+PE(Three phase five wire system)
Battery voltage
384VDC
480VDC
Battery Quantity
Standard with 32 Cells(30~34, can be set through the LCD panel) Standard 40 Cells(38~42 knots,can be set by LCD panel)
OUTPUT
Power factor
0.8/0.9 (Optional)
Voltage(V)
L-N: 220±1% L-L: 380±1%
Three-phase 100% load
unbalance voltage stability
≤2%,Allow 100% imbalance
Frequency(HZ)
Normal power, tracking the frequency of power, Grid abnormal. 50±0.2%
Transfer time(ms)
0ms
Parallel operation mode
(parallel type)
Max 8 Parallel
Waveform distortion
Linear loadTHD<3% ; Nonlinear loadTHD<5%
Overload capacity
125% full load for 10 minutes, maintain 150 % full load for 1 minute and then switch to bypass power supply,
after reducing the loadcan automatically restore the inverter
Crest factor
3:1
Others
Index
Standard with no transfer time maintenance bypass switch
Communication function
RS232/RS485/Dry Contact/SNMP (Optional)
Panel display
LED displays working status and fault indication; LCD displays three-phase input voltage,
input frequency, three-phase output voltage, load,battery voltage, battery charge and discharge current, etc
Display
7″ Touchable LCD screen display
The audio noise(dB)
<65(within 1 meter)
Alarm function
Battery low voltage, abnormal power supply, overload, UPS failure, over temperature protection
Protection
Input over voltage, battery under voltage, overload, short circuit, over temperature protection
Reviews
There are no reviews yet.