iSED Fully Automated ESR Analyzer
$0.00
In stock
The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR).
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Unlike traditional ESR methodologies that measure the aggregation of the red blood cells indirectly, the iSED measures it directly and expresses the values in mm/hr.
Features:
-
Results in 20 Seconds
-
100µL sample drawn directly from primary EDTA tube
-
Fully automated, walk-away operation
-
Random access
-
Positive patient identification via internal barcode reader
-
Compatible with pediatric tube
Technical Specifications:
| Principle of Measure: | Photometrical |
| Results: | “Printed mm/hr, Range from 1-130 mm/hr” |
| Sample Requirements: | 500uL whole blood, collected in EDTA anti-coagulant tested 24 hours from venipuncture at room temperature or refrigerated. |
| Tube Requirements: | 13 x 75 mm, pierceable capped tube |
| Quality Control: | Barcoded Seditrol® QC |
| Barcode Reader: | Internal |
| Printer: | Internal |
| Interface Specifications: | serial RS232 port for LIS connection |
| Weight: | 14 kg |
| Dimensions (H x W x D): | 36 x 27 x 34 (cm) /14.3 x 10.5 x13.4 (in) |
| Voltage: | 100-240VAC |
| Frequency Range: | 50-60 Hz |
| Power: | 160W |
Quick Comparison
| iSED Fully Automated ESR Analyzer remove | Eppendorf Pipette Tip 20ul Per Pack remove | Plastic Urine Container Per Pack remove | Skyla HB1 POC Clinical Chemistry Auto Analyzer remove | Eppendorf Pipette Tip 300ul Per Pack remove | Alcohol Pad Per Pack remove | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Name | iSED Fully Automated ESR Analyzer remove | Eppendorf Pipette Tip 20ul Per Pack remove | Plastic Urine Container Per Pack remove | Skyla HB1 POC Clinical Chemistry Auto Analyzer remove | Eppendorf Pipette Tip 300ul Per Pack remove | Alcohol Pad Per Pack remove | ||||||||||||||||||||||||||
| Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ||||||||||||||||||||||||||
| SKU | SF1033560084-129 | SF1033560084-136 | SF1033560084-106 | SF1033560060-1 | SF1033560084-138 | SF1033560084-64 | ||||||||||||||||||||||||||
| Rating | ||||||||||||||||||||||||||||||||
| Price |
|
| $8.20 |
|
| $4.25 | ||||||||||||||||||||||||||
| Stock | ||||||||||||||||||||||||||||||||
| Availability | ||||||||||||||||||||||||||||||||
| Add to cart | ||||||||||||||||||||||||||||||||
| Description | In stock
| In stock
| In stock
| Shipped from Abroad The skyla HB1 Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results. The portable design of the clinical chemistry analyzer utilizes precision photometric measurement technology, combined with the single-use disposable reagent discs. The reagent disc contains a set of dry assay reagents that are used in the quantitative testing of various biomarkers in the blood sample. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
| In stock Alcohol Pad (70% Isopropyl Alcohol Pre Pad, Alcohol Cleansing Swab). Clean the required area. Discard after single use. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | ||||||||||||||||||||||||||
| Content | The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Unlike traditional ESR methodologies that measure the aggregation of the red blood cells indirectly, the iSED measures it directly and expresses the values in mm/hr.
Features:
|
|
| Skyla HB1 Clinical Chemistry Analyzer utilizes precision photometric measurement technology, combined with the single-use disposable reagent discs. The reagent disc contains a set of dry assay reagents that are used in the quantitative testing of various biomarkers in the blood sample. HB1 provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results. Only needs 200µl of blood (whole blood, serum or plasma is accepted.) and no sample preparation is required. All steps are designed automatically from checking the validity of reagent discs and cartridges to printing the results. Over 30 test parameters are allowed with fast analysis and results in 15 minutes. Internal Quality Control (IQC) with self-calibration of optical system, chemicals stability and interference alerts functions monitor and ensure the results with high accuracy.
Available Test Panels
Click Here To Download Catalogue |
| Alcohol Pad (70% Isopropyl Alcohol Pre Pad, Alcohol Cleansing Swab). Clean the required area. Discard after single use.
Size and packing of Medical Alcohol pad:
Materials - Non-Woven Fabric
Trademark - OEM/ODM
Specification - CE&ISO13485
| ||||||||||||||||||||||||||
| Weight | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||||||
| Dimensions | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||||||
| Additional information |







Reviews