Features:
- Intelligent CPU control
- Automatic power on when the the main power recovers
- Cold start function
- Power off charging function
- USB/RS232/RJ-11/RJ-45 communication port (optional)
- Offering LED and LCD panels for selection
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Features:
- Optional 7 ” touch LCD
- Online double-conversionDSP technology guarantees high reliability
- True galvanic isolation transformer designControl designed to withstand all kinds of loads
- Intelligent battery management to prolong battery lifecycle
- Redundant fan design and independent ventilation enhance durable operation under harsh environment
- Adiustable battery numbers
- Accept dual-mains input
- Parallel operation with up to 4 units ( option )
- Variety of communication options available
- Reverse phase frequency operation and supportsnon-neutral input
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| |
Content | Features:
- Intelligent CPU control
- Automatic power on when the the main power recovers
- Cold start function
- Power off charging function
- USB/RS232/RJ-11/RJ-45 communication port (optional)
- Offering LED and LCD panels for selection
Application:
- Personal Computer
- Printer
- POS(Point of sales)Terminals
- Security System
- Fax Machine
- Modem, WiFi Router
Technical Specifications:
Model |
DP600 |
DP1000 |
DP1200 |
DP2000 |
DP3000 |
Capacity |
600VA/360W |
1000VA/600W |
1200VA/720W |
2000VA/1200W |
3000VA/1800W |
INPUT |
Voltage |
110/120VAA or 220/230/240VAC |
Voltage Range |
67-137VAC/135-275VAC |
Frequency Range |
50Hz Or 60Hz(Auto-Sensing) |
OUTPUT |
Output Voltage |
110/120VAA or 220/230/240VAC |
AC Voltage Regulation |
± 10% |
Frequency Range
(Batt. Mode) |
50 HZ or 60 Hz ± 10% |
Transfer Time |
Typical 6-10 ms |
Waveform
(Battery Mode) |
Simulated Sine Wave |
BATTERY |
Battery Voltage |
12V/7AH*1 |
12V/9AH*1 |
12V/7AH*2 |
12V/9AH*2 |
12V/7AH*4 |
Charge Time |
8 hours up to 80-90% |
PROTECTION |
Full Protection |
Auto Detection, discharge protection,output Short circuit, Over load, Battery low voltage protection |
Communication Port |
USB/RS232/RJ11/RJ45 (Optional) |
Display |
LED/LCD |
Alarm |
Battery Mode |
Every 4 Seconds one beep |
Low Battery Capacity |
Every 1 Seconds one beep |
Overload |
Every 1 Seconds one beep |
Fault |
Keep beeping |
ENVIRONMENT |
Humidity |
0-90% Rh @ 0-40℃ (Non-Condensing) |
Noise Level |
40dB |
Dimension(mm) |
320*90*140 |
330* 100*150 |
365*140*165 |
365*140*165 |
395*145*210 |
N.W.(kg) |
5.2 |
6 |
10 |
12.6 |
21 |
| Features:
Digital Control
All parts of this series of UPS adopt digital control, each performance index of UPS is very excellent, and the control system is morestableand reliable.Each module has built-in
automatic bypass switch and corresponding bypass current equalizing inductor, providing good bypass power supply equalization performance.
Intelligent Battery Management
Users can set the charging current, constant current, constant voltage and floatingcharging modescan be automatically and smoothly switched; Battery voltage can beset
±192Vdc/±240Vdc/±216Vdc/±228Vdc/±240Vdc (32/34/36/38/40 pcs optional)
High Power Density Modular Design
The capacity of each single module is30kVA, and the height is3U; UPS modulescan be added and removed onlineto achieve zero maintenance time.
N+x Parallel Redundancy
The quantity of redundant module can be set accordingly, When the redundant module reaches more than 2 hours, the system availability achieves 99.99%,
MTBF(Mean Time Between Failures) lasts more than 250,000 hours; Supporting parallel connection between cabinets.
A maximum of four cabinets can be parallel,and battery pack can be shared when UPS cabinet in parallel.
Touchable LCD Display Screen
Super large LCD display with touching function.
Standard Cabinet Design
The appearance ofthe standard cabinet is beautiful and generous, which can perfectly match the use environment ofthe computer room and save the space.
Safe and Easy to Maintain
When an emergency occurs, users can switch to the maintenance bypass to supply power, and maintenance personnel can safely perform online maintenance;
Press EPO button to shutdown in emergentsituation, and also have REPO function.
Intelligent Management
Centralized monitoring module (with hot-swap function), RS232/RS485 communication interface/SNMPcard (optional), can realize remote monitoringof UPS, relay card is optional.
Technical Specifications
Model |
VM 90K |
VM150K |
VM300K |
Capacity |
UPS Cabinet |
30-90KVA |
30-150KVA |
30-300KVA |
Power Module |
30kVA |
INPUT |
Input Form |
3P4W+G |
Rated Voltage |
380/400/415Vac |
Voltage Range |
207~478Vac |
Frequency Range |
40~70Hz |
Input Power Factor |
≥0.99 |
Bypass Range |
380 upper limit: 25% (optional +10%s +15%、+20%)
400 upper limit: 20% (optional +10%、+15%)
415 upper limit: 15% (optional +10%) Lower limit: -45% (optional -20%s -30%)
Bypass frequency protection range: ± 10% |
Input Current Harmonic Wave |
≤3% (100% non-linear) |
OUTPUT |
Output Form |
3P4W+G |
Rated Voltage |
380/400/415Vac |
Output Power Factor |
0.9 or 1 |
Voltage Accuracy |
±1% |
Output Frequency |
Mains Mode |
Synchronization with input; when mains frequency exceeds maximum value ±10%
(can be set ±1%、 ±2%、±4%、±5%), output frequency 50X(±0.2%)Hz |
Battery Mode |
(50/60±0.2%) Hz |
Crest Factor |
3:1 |
Conversion Time |
Mains mode — bypass mode: 0ms (tracking); Mains mode— battery mode: 0ms |
Overload Capacity |
Load≤110%: 60 mins;
Load≤125%: 10 mins;
Load≤150%: 1 min;
Load≥150%, shutdown immediately |
Output Voltage Harmonic Wave |
≤2% (100% linear) |
Efficiency |
In normal mode 95% |
Communication Port |
RS232、RS485、 Intelligent Slot*2 、 Dry connect port |
BATTERY |
Battery Voltage |
±192Vdc/±204Vdc/±216Vdc/±228Vdc/±240Vdc; (32/34/36/38/40pcs Optional) |
Charging Current |
UPS Cabinet |
30A Max |
50A Max |
100A Max |
Power Module |
10A Max |
Environment |
Operating Temperature |
0〜40°C |
Relative Humidity |
0-95% (non-condensing) |
Storage Temperature |
-25-55°C (excluded battery) |
Altitude |
< 1500m (derating if exceeding 1500m) |
Physical Characteristic |
Outer Dimension (LxWxH) mm |
Cabinet |
840X600X1400 |
1100X600X2000 |
Module |
580 X 443 X 131 |
Weight
(Net Weight) KG |
Cabinet |
158 |
170 |
305 |
Module |
33.5 |
Operative Standard |
YD/T 2165-2010 |
| Features:
- Capacity: 600W 512Wh /160000mAh
- Input AC Output Power:Rated Power 600W Peak Power 1200W
- Input AC Charging:AC100~120V/AC200~240V Built-in 200W
- Input Car Charging:DC12V~24V/7A Max 120W Max
- Input Solar Charging:DC12V~24V/120WMax
- Output Voltage:230VAC±10%/110VAC±10%
- Output Frequency: 50Hz±5%/60Hz±5%
- USB Output:2*QC24W+PD27W+PD100W Max
- DC Output:1*Cigarette Lighter+2*DC5521 Rated Output (13.8V/10A Max)
- Output Waveform:Pure Sine Wave
- LED:3 Levels(H/M/L)+SOS
- UPS Function:Support(≤10mS)
Applications:
- Mammogram
- Ultrasound Equipments
- Radiology rooms
| Features:
- Optional 7 ” touch LCD
- Online double-conversionDSP technology guarantees high reliability
- True galvanic isolation transformer designControl designed to withstand all kinds of loads
- Intelligent battery management to prolong battery lifecycle
- Redundant fan design and independent ventilation enhance durable operation under harsh environment
- Adiustable battery numbers
- Accept dual-mains input
- Parallel operation with up to 4 units ( option )
- Variety of communication options available
- Reverse phase frequency operation and supportsnon-neutral input
Specifications
MODEL |
LF33 10K |
LF33 20K |
LF33 30K |
LF33 40K |
LF33 60K |
LF33 80K |
LF33 100K |
LF33 120K |
LF33 160K |
LF33 200K |
CAPACITY |
10KVA /8KW |
20KVA /16KW |
30KVA /24KW |
40KVA /32KW |
60KVA /48KW |
80KVA /64KW |
100KVA /80KW |
120KVA /96KW |
160KVA /128KW |
200KVA /160KW |
INPUT |
Nominal Voltage |
3 x 380VAC/400VAC (3Ph + N) |
Acceptable Voltage Range |
305VAC ~ 460VAC |
Frequency |
46-54Hzor56-64Hz |
INVERTER |
Nominal Voltage |
3 x 380VAC/400VAC (3Ph + N) |
Precision |
Stationary: ±1% Transitory: ±5% (load variations 100-0-100%) |
Frequency |
50/60 Hz synchronised ±1 % With mains absent ±0.1 Hz |
Max. Synchronisation Speed |
±1 Hz/s |
Waveform |
Pure Sinewave |
Total Harmonic Distortion (THDv) |
<2% (Linear Load) ; <5% (Non-linear Load) |
Phase Displacement |
120° ±1 % (balanced load); 120° ±2% (imbalances 50% of the load) |
Dynamic Recovery Time |
Restore to 90% of rated value in 3 cycles |
Overload capacity |
110% for 10min; 150% for 60sec; >160% for 200ms |
Admissible Crest Factor |
3:1 |
Admissible Power Factor |
0.6-1 (inductive or capacitive) |
Imbalance Output Voltage @ 100% Unbalanced Load |
<1% |
Current Limit |
High overload, short-circuit: RMS Voltage Limit; High Crest-Factor current: Peak Voltage Limit |
STATIC BYPASS |
Type |
Solid state |
Voltage |
3 x 380VAC/400VAC (3Ph + N) |
Frequency |
50/60 Hz |
Activation Criterion |
Microprocessor control |
Transfer Time |
Zero |
Admissible Overload |
150% for 1 hour; 180% for 30sec; >200% for 200ms |
Transfer to Bypass |
Immediate, for overloads above 160% |
Retransfer |
Automatic after alarm clear |
MAINTENANCE BYPASS |
Type |
Without interruption |
Voltage |
3 * 400V (3Ph + N) |
Frequency |
50/60 Hz |
Overall Efficiency |
Line Mode |
90% |
91% |
92% |
93% |
Battery Mode |
90% |
91% |
93% |
93% |
BATTERY & CHARGER |
Battery Type and Numbers |
12VDC * 32 pcs (29-32 pcs adjustable) |
Nominal Battery Voltage |
384 VDC (Based on 32pcs batteries) |
Charging Method |
CC/CV |
Precision |
±1% |
Charging Current |
Max.: 40 A |
Charging Voltage |
432 VDC (Based on 32pcs batteries) |
PHYSICAL |
Dimensions, D x W x H(mm) |
656 x 405 x 817 |
656 x 405 x 941 |
840x432x1140 |
975x554x1286 |
1200x910x1680 |
1500x1140x1800 |
Net Weight (Kgs) |
180 |
205 |
295 |
330 |
451 |
519 |
950 |
1350 |
| Features:
- Capacity: 1200W 1008Wh /315000mAh
- Input AC Output Power:Rated Power 1200W Peak Power 2400W
- Input AC Charging:AC100~125V/AC184~264V Bidirectional Inverter 700W Max
- Input Car Charging:DC12V~24V/10A 240W Max
- Input Solar Charging:DC12V~60V/10A 400W Max
- Output Voltage:230VAC±10%/110VAC±10%
- Output Frequency: 50Hz±5%/60Hz±5%
- USB Output:2*5V2.4A +2*QC18W+2*PD60W Max
- DC Output:1*Cigarette Lighter+2*DC5521 Rated Output (13.8V/10A Max)
- Output Waveform:Pure Sine Wave
- LED:3 Levels(H/M/L)+SOS
- UPS Function:Support(≤10mS)
Applications:
- Mammogram
- Ultrasound Equipments
- Radiology rooms
| Features:
Three Phase Hybrid Solar Inverter
Off grid three phase solar hybrid inverter with pwm/mppt can be used in single-phase and three-phase ac load with total power not exceeding 100kva/120kva/125kva/150kva/160kva,384vdc to 380vac.
•Pure sine wave output.
•Low DC voltage, saving system cost.
•Three phase solar inverter with built-in PWM or MPPT charge controller.
•AC charge current 0-45A adjustable.
•Wide LCD screen, clearly and precisely shows icon data.
•100%imbalance loading design, 3 times peak power.
•Setting different working modes based on variable usage requirements.
•DC first/AC first optional.
•Various communication ports and remote controls
Specifications
MODEL |
DX100KVA |
DX120KVA |
DX125KVA |
DX150KVA |
DX160KVA |
190KVA |
200KVA |
Rated Power |
80KW |
96KW |
100KW |
120KW |
128KW |
150KW |
160KW |
Peak Power(20ms) |
240KVA |
288KVA |
300KVA |
360KVA |
384KVA |
450KVA |
480KVA |
Start Motor |
40HP |
50HP |
50HP |
60HP |
60HP |
80HP |
80HP |
Battery Voltage |
384VDC |
Size(L*W*Hmm) |
875*720*1380 |
1123*900*1605 |
Packing Size(L*W*Hmm) |
980*825*1560 |
1185*960*1750 |
N.W.(kg) |
512 |
592 |
612 |
612 |
642 |
705 |
755 |
G.W.(kg)(Wooden Packing) |
552 |
632 |
652 |
652 |
692 |
755 |
805 |
INPUT |
DC Input Voltage Range |
10.5VDC-15VDC(Single battery voltage) |
AC Input Voltage Range |
380Vac/400Vac±10%(customized 190Vac/200Vac) |
AC Input Frequency Range |
45Hz-55Hz(50Hz)/ 55Hz-65Hz(60Hz) |
Max AC charging current |
0-45A(Depending on the model) |
AC charging method |
Three-stage (constant current, constant voltage, floating charge) |
Phase |
3 PHASE |
OUTPUT |
Efficiency(Battery Mode) |
≥85% |
Output Voltage(Battery Mode) |
380Vac/400Vac±10%(customized 190Vac/200Vac) |
Output Frequency(Battery Mode) |
50/60Hz ±1% |
Output Wave(Battery Mode) |
Pure Sine Wave |
Output waveform distortion |
Linear load≤3% |
Efficiency(AC Mode) |
>99% |
Output Voltage(AC Mode) |
Conforming to AC input |
Output Frequency(AC Mode) |
Conforming to AC input |
No load loss(Battery Mode) |
≤1% rated power |
No load loss(AC Mode) |
≤2%rated power( charger does not work in AC mode) |
No load loss
(Energy saving Mode) |
≤10W |
Phase |
3 PHASE |
BATTERY |
VRLA Battery |
Charge Voltage :13.8V; Float Voltage:13.7V(Single battery voltage) |
Customize battery |
Charging and discharging parameters of different types of batteries can be customized according to user requirements |
(charging and discharging parameters of different types of batteries can be set through the operation panel) |
Protection |
Battery undervoltage alarm |
11V(Single battery voltage) |
Battery undervoltage protection |
10.5V(Single battery voltage) |
Battery overvoltage alarm |
15V(Single battery voltage) |
Battery overvoltage protection |
17V(Single battery voltage) |
Battery overvoltage recovery voltage |
14.5V(Single battery voltage) |
Overload power protection |
Automatic protection (battery mode), circuit breaker or insurance (AC mode) |
Inverter output short circuit protection |
Automatic protection (battery mode), circuit breaker or insurance (AC mode) |
Temperature protection |
>90°C(Shut down output) |
Alarm |
A |
Normal working condition, buzzer has no alarm sound |
B |
Buzzer sounds 4 times per second when battery failure, voltage abnormality, overload protection |
C |
When the machine is turned on for the first time, the buzzer will prompt 5
when the machine is normal |
Inside Solar controller |
Charging Mode |
MPPT or PWM |
(Optional) |
Charging current |
PWM: 100A-200A / MPPT: 50A/100A |
|
PV Input Voltage Range |
PWM: 480V-704V / MPPT: 480V-640V |
|
Max PV Input Voltage(Voc) |
PWM: 750V / MPPT: 800V |
|
(At the lowest temperature) |
|
PV Array Maximum Power |
PWM: 44.8KW(100A)/33.6KW*2(150A)/44.8KW*2(200A)) / (MPPT: 22.4KW(50A)/22.4KW*2(100A) |
|
Standby loss |
≤3W |
|
Maximum conversion efficiency |
>95% |
Working Mode |
Battery First/AC First/Saving Energy Mode |
Transfer Time |
≤4ms |
Display |
LCD |
Thermal method |
Forced Air Cooling |
Communication(Optional) |
RS485/APP(WIFI monitoring or GPRS monitoring) |
Environment |
Operating temperature |
-10℃~40℃ |
Storage temperature |
-15℃~60℃ |
Noise |
2000m(More than derating) |
Elevation |
≤65dB |
Humidity |
0%~95% ,No condensation |
|