medilog DARWIN2 is an advanced Holter-analysis software designed for high-volume cardiovascular diagnostics. It automates arrhythmia detection, supports long-term ECG recordings (24 h–14 days), and enables rapid report generation — ideal for cardiology labs and rhythm monitoring services.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Brands:: SCHILLER

Description

The medilog DARWIN2 platform streamlines ambulatory ECG review and reporting. With ultra-high signal-quality algorithms (including true P-wave detection), automatic beat-classification, HRV (“Fire of Life”) analysis, respiration/SpO₂ integration, and optional modules for blood-pressure and remote upload, it’s tailored for routine clinic workflows and research centres alike. The software offers rapid automated analyses (a 24-hour recording can be processed in under 90 seconds), an intuitive user interface with configurable templates, and export options (PDF, PDF-reporting, etc.) for seamless integration into clinical workflows.

Save time and detect health risks at a glance: with the medilog Holter system.

DARWIN2 is designed to maximise speed and ease of use. The automatic analysis of a 24-hour Holter recording takes less than 90 seconds, with extremely accurate results. Data review is faster than ever: it takes only three mouse clicks to generate a comprehensive report.

Features
  • Real-time P-wave detection for accurate atrial fibrillation screening
  • PureECG technology for superior signal quality
  • ECHOView for instantaneous detection of atrial fibrillation onset
  • Respiration analysis during sleep with synchronised ECG, respiration waveforms, and SpO2 readings
  • Fire of Life: a brilliant approach to Heart Rate Variability analysis
  • Blood pressure analysis: use ABPM-recorder and evaluate with medilog DARWIN2
  • It is available in three different versions to suit the needs of any organisation and to grow with it:
    • DARWIN2 Office: optimised for routine application in physicians’ offices
    • DARWIN2 Professional: perfect for a small to mid-sized Holter scanning centre with the need for fast atrial fibrillation detection
    • DARWIN2 Enterprise: for the most demanding research centres and high-volume hospitals. Includes atrial fibrillation, respiration analysis, SpO2, and an option for the ScanLab web service
  • Branded and personalised medilog DARWIN2 reports
  • Recording upload from anywhere with Medilog DARWIN2 Liberty for organisations with patients in remote locations
Specifications
Parameter Specification (typical)
Holter recording support 24 h, 48 h, 72 h, up to 14 days (depending on recorder)
Arrhythmia detection Real-time P-wave algorithm, AF/Flutter screening
Signal processing High-sampling ECG and noise suppression
Data integration ECG + respiration + optional SpO₂ + optional BP
Report generation PDF, customizable templates, user branding
Use case editions Office, Professional, Enterprise

 

SCHILLER’S MEDILOG HOLTER SYSTEM

Reviews

There are no reviews yet.

Be the first to review “medilog DARWIN2”

Your email address will not be published. Required fields are marked *

Quick Comparison

medilog DARWIN2 removeLittmann Classic III Stethoscope removeSonoscape S8 Exp Portable Ultrasound removeFlowMir Disposable Turbine with Cardboard Mouthpiece removeTimesco Jumper Fingertip Pulse Oximeter removeSonoscape S11 Ultrasound Machine remove
Namemedilog DARWIN2 removeLittmann Classic III Stethoscope removeSonoscape S8 Exp Portable Ultrasound removeFlowMir Disposable Turbine with Cardboard Mouthpiece removeTimesco Jumper Fingertip Pulse Oximeter removeSonoscape S11 Ultrasound Machine remove
ImageLittmann Classic III StethoscopeS8 Portable Ultrasound ScannerFlowMir Disposable Turbine with Cardboard MouthpieceFingertip Pulse Oximeter
SKUSF1033560084-34SF1033560012-15SF1033560084-22SF1033560084-2SF1033560012-1
Rating
Price

$0.00

$34.00

$9,350.00

$145.00

$17.00

$6,380.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad

medilog DARWIN2 is an advanced Holter-analysis software designed for high-volume cardiovascular diagnostics. It automates arrhythmia detection, supports long-term ECG recordings (24 h–14 days), and enables rapid report generation — ideal for cardiology labs and rhythm monitoring services.

Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock The Classic III stethoscope brings new design, materials, and technology to the Littmann stethoscope series that’s been used and trusted by millions of medical professionals worldwide for decades. With a two-sided chestpiece, dual tunable diaphragms, improved tubing, and much more, the Classic III stethoscope combines the best of new and traditional.

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad With ultra-modern innovative design and the clinically-proven technologies, S8 Exp is portable ultrasound scanner well equipped as a low-physical-effort and enhanced-image-quality ultrasound scanner, which not only provides optimized solutions for versatile applications, but does help to improve the user-experience for both routine and non-traditional challenges. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock Spirometry testing requires maximum accuracy and hygiene. Each Flowmir disposable turbine, which includes a cardboard mouthpiece, has been individually factory calibrated with a computerized system and it is packaged individually. FlowMIR® is an inexpensive alternative to a costly reusable flowmeter and replaces the need for an antibacterial filter Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In Stock Integrated with SPO2 probe and processing display module. Small in volume、light in weight and convenient in carrying. Operation of the product is simple ,low power consumption. SPO2 , PR and Ridisplay,. Pulse rate value display, bar graph display. Low-voltage indication: low-voltage indicator appears before working abnormally which is due to low-voltage. Automatically power off function: when the device is under the state of measuring interface . it will automatically power off within 5 seconds if the finger falls out of probe. Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In Stock A Value Choice beyond Your Expectation. SonoScape’s trolley color Doppler system S11 redefines price and performance with practical design. The S11 will go beyond your expectations but not your budget. Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
ContentThe medilog DARWIN2 platform streamlines ambulatory ECG review and reporting. With ultra-high signal-quality algorithms (including true P-wave detection), automatic beat-classification, HRV (“Fire of Life”) analysis, respiration/SpO₂ integration, and optional modules for blood-pressure and remote upload, it’s tailored for routine clinic workflows and research centres alike. The software offers rapid automated analyses (a 24-hour recording can be processed in under 90 seconds), an intuitive user interface with configurable templates, and export options (PDF, PDF-reporting, etc.) for seamless integration into clinical workflows.

Save time and detect health risks at a glance: with the medilog Holter system.

DARWIN2 is designed to maximise speed and ease of use. The automatic analysis of a 24-hour Holter recording takes less than 90 seconds, with extremely accurate results. Data review is faster than ever: it takes only three mouse clicks to generate a comprehensive report.
Features
  • Real-time P-wave detection for accurate atrial fibrillation screening
  • PureECG technology for superior signal quality
  • ECHOView for instantaneous detection of atrial fibrillation onset
  • Respiration analysis during sleep with synchronised ECG, respiration waveforms, and SpO2 readings
  • Fire of Life: a brilliant approach to Heart Rate Variability analysis
  • Blood pressure analysis: use ABPM-recorder and evaluate with medilog DARWIN2
  • It is available in three different versions to suit the needs of any organisation and to grow with it:
    • DARWIN2 Office: optimised for routine application in physicians’ offices
    • DARWIN2 Professional: perfect for a small to mid-sized Holter scanning centre with the need for fast atrial fibrillation detection
    • DARWIN2 Enterprise: for the most demanding research centres and high-volume hospitals. Includes atrial fibrillation, respiration analysis, SpO2, and an option for the ScanLab web service
  • Branded and personalised medilog DARWIN2 reports
  • Recording upload from anywhere with Medilog DARWIN2 Liberty for organisations with patients in remote locations
Specifications
Parameter Specification (typical)
Holter recording support 24 h, 48 h, 72 h, up to 14 days (depending on recorder)
Arrhythmia detection Real-time P-wave algorithm, AF/Flutter screening
Signal processing High-sampling ECG and noise suppression
Data integration ECG + respiration + optional SpO₂ + optional BP
Report generation PDF, customizable templates, user branding
Use case editions Office, Professional, Enterprise
  SCHILLER'S MEDILOG HOLTER SYSTEM
The Classic III stethoscope brings new design, materials, and technology to the Littmann stethoscope series that’s been used and trusted by millions of medical professionals worldwide for decades. With a two-sided chestpiece, dual tunable diaphragms, improved tubing, and much more, the Classic III stethoscope combines the best of new and traditional. Full adult and pediatric auscultation is available through its dual head chestpiece simply by rotating the central spline to alternate between the two sides. The more compact one piece diaphragm and rim assemblies have further increased acoustic sensitivity. The binaurals have been redesigned with larger diameter ear tubes and a thicker single lumen binaural to transfer sound more effectively. The selector spline is now recessed to allow a flush fit with the binaural tube and now features a visual indicator for easy identification of the operational diaphragm. Features
  • NEW: double-sided, dual diaphragm chestpiece for both adult and paediatric assessment.
  • NEW: The paediatric side is also easily transformed into a traditional open bell by replacing the single-piece diaphragm with the supplied non-chill rim.
  • NEW: chestpiece is precision-machined into an aesthetically pleasing, less angular shape.
  • NEW: single-piece diaphragm instead of separate diaphragm/rim making it easier to attach and easier to clean due to the smooth unbroken surface.
  • NEW: The stem features an open side indicator to easily identify which diaphragm is in operation.
  • NEW: next-generation tubing gives even longer tube life with improved resistance to skin oils, alcohol and staining.
  • 3M’s ‘Tunable Technology’ lets you easily switch from low to high frequency sounds by switching from light to firm pressure on both the adult and paediatric sides of the chestpiece.
  • High acoustic sensitivity when performing general physical assessment.
  • Laser engraving of text and symbols to personalise your scope and avoid theft/loss
  • Larger ear tubes on the anatomically designed headset comfortably positioned for better sound transfer. Easy adjustment by simply squeezing or pulling apart the eartubes.
  • Comfortable Snap-Tight soft seal eartips create an excellent acoustic seal to reduce ambient noise.
  • No natural rubber latex or phthalate plasticisers are used in the tubing or any other component—to help protect health and the environment.
  • Complement your personal style with Littmann’s large range of chestpiece finishes and tubing colours.
  • Used as a diagnostic aid as part of the physical assessment of a patient.

Sonoscape S8 Exp Portable Ultrasound scanner

DETAILS Agile and Versatile With ultra-modern innovative design and the clinically-proven technologies, S8 Exp Portable Ultrasound scanner is well equipped as a low-physical-effort and enhanced-image-quality ultrasound scanner, which not only provides optimized solutions for versatile applications but does help to improve the user experience for both routine and non-traditional challenges. Working with S8 Exp, it will trigger your unlimited reverie and endow you with endless charm. Carrying forward the classical design of SonoScape's portable ultrasound products, S8 Exp successfully combines the best ergonomics, attractive design and ease of use. This charismatic identity is also enhanced by a sophisticated color palette—with sedate grey as its interior paint color and pearl white as exterior cover, S8 Exp reveals a style of aristocrat and strong character among SonoScape's ultrasound systems. Workflow The S8 Exp is a portable ultrasound scanner that adapts to your workflow, whether you are in the consulting room, at the bedside, or at a remote location. With easy-to-use new platform designed for sonographers' needs and full connection interfaces for easy connectivity and data sharing, S8 Exp leads to improved user comfort and clinical outcome as well as patient throughput and working efficiency. Powerful Platform Embedded with SonoScape's core imaging technologies such as μ-scan, PHI and Spatial Compound, S8 Exp boasts exceptional 2D image, sensitive spectral, Color and Power Doppler, displaying well-defined anatomy and pathology and facilitating a highly optimized diagnostic user environment for conclusive diagnoses. Besides, S8 Exp offers a comprehensive selection of electronic probes to maximally extend its capabilities to meet a wide range of applications including the abdomen, pediatric, OB/GYN, cardiovascular, musculoskeletal, etc. The advanced probe technologies also effectively enhance the image quality and confidence in reaching clinical diagnoses even in difficult patients.
Click Here To Download Catalogue
 
    • Comfortable Packaging
    • Singularly Tested and Packed
    • Always 100% accurate and hygienic
    • No Calibration required
    • No Sterilization required
    • No Antibacterial Filter required
    • No Cross Contamination
    • Not affected by Vapour Condensation
    • Not affected by Ambient conditions
    •  A full Spirometry session can be performed, including a Bronchial Challenge and POST Bronchodilator test. For each patient after the Spirometry test, both turbine and spirometer mouthpiece are thrown away
    • .
   
Integrated with SPO2 probe and processing display module • Small in volume, light in weight, convenient in carrying • Simple operation, lower power consumption • OLED screen display • SPO2, PR, bar graph of pulse, plethysmogram, blood perfusion index, battery indication display • 4 directions display, 6 display models, large fonts display • Brightness control, Demo mode, Setup menu • Movement interference • Alarm function and adjustable alarm parameters • Can be connected to mobile phones through Bluetooth; can support Android and iOS client • Auto power-off when no signal after 10s • Powered by 2*AAA alkaline batteries Specification: • Size: 62 x 37 x 32mm • Peak wavelength range of the light emitted from the probe: red light 660nm±3; infrared light 905nm±5 • Maximum optical output power of the probe: 1.2mW for infrared light (905nm) • Bluetooth module: 4.0 (single-mode) • Working temperature: 5℃ to 40℃ (41°F to 104°F) • Relative humidity: 15% to 80%, non-condensing • Atmospheric pressure: 70kPa to 106kPa • Rated voltage: DC 3V Package included: • 1 x JUMPER JPD-500F Bluetooth Fingertip Pulse Oximeter • 2 x AAA Batteries • 1 x Carry Case • 1 x Lanyard • 1 x English User ManualDETAILS SonoScape’s trolley colour Doppler system S11 redefines price and performance with practical design. The S11 will go beyond your expectations but not your budget. As an easy-to-use ultrasound system, the S11 is integrated with a new software platform, especially optimized for a smooth workflow and convenient operation. The system speeds up the exam process and makes file management easier. SPECIFICATION - 15-inch high definition LCD monitor with articulating arm - Compact and agile trolley design - 3 active transducer sockets available for a wide range of applications - Duplex, Color Doppler, DPI, PW Doppler, tissue harmonic imaging, μ-scan speckle reduction imaging, compound imaging, trapezoidal imaging - Customized settings based on your own working style - Full patient database and image management solutions  
Click Here To Download Catalogue 
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare