Nasogastric feeding tube fixation device

$0.00

Shipped From Abroad

The utility model has a simple structure and can prevent the nasogastric feeding tube from slipping out or slipping in when the medical staff inserts the nasogastric feeding tube into the patient, and the nasogastric feeding tube is firmly fixed, thereby reducing the pain of the patient and the work difficulty of the medical staff.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130104-26

Description

Product details

The utility model has a simple structure and can prevent the nasogastric feeding tube from slipping out or slipping in when the medical staff inserts the nasogastric feeding tube into the patient, and the nasogastric feeding tube is firmly fixed, thereby reducing the pain of the patient and the work difficulty of the medical staff.

Scope of use

It is mainly used on the nose tip to wrap around and fix the nasogastric feeding tube. The V-shaped one can fix a double-tube nasogastric feeding tube, and the L-shaped one can fix a single-tube nasogastric feeding tube. Patients can choose according to their needs.

Precautions when using the catheter fixing device

1. Single use only.

2. Do not use if the packaging bag is damaged.

3. It cannot replace suturing, hemostasis, skin disinfection and other measures.

4. It cannot be used to fix arterial catheters.

Product Specifications

Part Number Product Usage Specification
A0207 Nasogastric feeding tube fixation device 2×7cm without foam
A0208 PICC catheter fixation device  2×8cm Peanut Shape
A0309W Indwelling needle fixation device  3×9cm without foam
A0309WK PICC catheter fixation device  3×9cm non-foam with holes
A0309 PICC catheter fixation device  3×9cm Peanut Shape
A0309R PICC catheter fixation device  3×9cm Airplane type
A0309F PICC catheter fixation device  3×9cm Airplane type
B0309 Epidural fixation device  3×9cm tear on both sides
B0607 Indwelling needle fixation device 6×7cm
C0309 Catheter Fixation Device  3×9cm belt buckle type
C0611 Catheter Fixation Device 6×11cm belt buckle type
C0611F Central venous catheter fixation device 6×11cm Aircraft Type
F0346 Endotracheal tube fixation belt 4.6cm long*3.2cm wide
F0609 Endotracheal tube fixing belt accessories 9×6-0.3cm foam
F1 Airway tube holder
L0308 Nasogastric feeding tube fixation device 3×8cm V-shaped
L0710 Nasogastric feeding tube fixation device 7×10cm L-shaped
D0309 PICC catheter fixation device 3×9cm Silolock
C0812 Catheter Fixation Device 8×12cm gourd shape
B0812 Drainage tube fixation device 8×12cm gourd shape
F0556 Drainage tube and urinary catheter fixation 4.8CM wide*56Cm long

Reviews

There are no reviews yet.

Be the first to review “Nasogastric feeding tube fixation device”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsNasogastric feeding tube fixation device removeMaico TouchTymp MI36 Tympanometry removeDe Lineb Oxygen Face Mask removeBistos BT-770-12.1" Touchscreen Patient Monitor removeBistos BT- 720 Patient Monitor removeTimesco Jumper Fingertip Pulse Oximeter remove
NameNasogastric feeding tube fixation device removeMaico TouchTymp MI36 Tympanometry removeDe Lineb Oxygen Face Mask removeBistos BT-770-12.1" Touchscreen Patient Monitor removeBistos BT- 720 Patient Monitor removeTimesco Jumper Fingertip Pulse Oximeter remove
ImageMaico TouchTymp MI36 Tympanometry and AmpBistos BT-770-12.1" Touchscreen Patient MonitorBistos BT-720 Patient MonitorFingertip Pulse Oximeter
SKUSF1033560130104-26SF1033560063-10SF1033560084-39SF1033560059-1SF1033560059-8SF1033560084-2
Rating
Price

$0.00

$0.00

$1.40

$902.00

$330.00

$17.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad The utility model has a simple structure and can prevent the nasogastric feeding tube from slipping out or slipping in when the medical staff inserts the nasogastric feeding tube into the patient, and the nasogastric feeding tube is firmly fixed, thereby reducing the pain of the patient and the work difficulty of the medical staff.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad TouchTymp MI 36 combines diagnostic middle ear analyzer and audiometry tests in one exceptional device. The full 10.4" touchscreen with its user-friendly interface guarantees a unique intuitive operation and allows to quickly change parameters. You can easily switch between the tests without reorganizing from one to another device and beneft from its small footprint when facing limited desk space. touchTymp MI 36 really improves your workflow every day. Delivery & Availability: Typically 10 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
De Lineb Oxygen Face Mask: This mask provides a method to transfer breathing oxygen gas from a storage tank to the lungs. Oxygen masks may cover only the nose and mouth (oral nasal mask) or the entire face (full-face mask).
  Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad The Bistos BT-770 patient monitor is equipped with a 12.1" touchscreen display, which allows for an easy operation and readability with a powerful rechargeable battery guaranteeing a continuous operation of 5 hours to monitor ECG, SpO2, NIBP, temperature and respiration Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped from abroad Bistos BT - 720 Patient Monitor: Bistos Portable Patient Vital Signs Monitor, SpO2, Pulse, *NIBP, BT-720. The Bistos BT-720 is a compact size vital signs monitor with the standard parameters of SpO2 and Pulse. You can also add the NIBP and/or Masimo SpO2 at an additional cost. The BT-720 has a 4.3" color touch screen The PC software allows the vital signs information to be transferred and analyzed on a computer. Delivery & Availability: Typically 7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In Stock Integrated with SPO2 probe and processing display module. Small in volume、light in weight and convenient in carrying. Operation of the product is simple ,low power consumption. SPO2 , PR and Ridisplay,. Pulse rate value display, bar graph display. Low-voltage indication: low-voltage indicator appears before working abnormally which is due to low-voltage. Automatically power off function: when the device is under the state of measuring interface . it will automatically power off within 5 seconds if the finger falls out of probe. Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content

Product details

The utility model has a simple structure and can prevent the nasogastric feeding tube from slipping out or slipping in when the medical staff inserts the nasogastric feeding tube into the patient, and the nasogastric feeding tube is firmly fixed, thereby reducing the pain of the patient and the work difficulty of the medical staff.

Scope of use

It is mainly used on the nose tip to wrap around and fix the nasogastric feeding tube. The V-shaped one can fix a double-tube nasogastric feeding tube, and the L-shaped one can fix a single-tube nasogastric feeding tube. Patients can choose according to their needs.

Precautions when using the catheter fixing device

1. Single use only. 2. Do not use if the packaging bag is damaged. 3. It cannot replace suturing, hemostasis, skin disinfection and other measures. 4. It cannot be used to fix arterial catheters.

Product Specifications

Part Number Product Usage Specification
A0207 Nasogastric feeding tube fixation device 2×7cm without foam
A0208 PICC catheter fixation device  2×8cm Peanut Shape
A0309W Indwelling needle fixation device  3×9cm without foam
A0309WK PICC catheter fixation device  3×9cm non-foam with holes
A0309 PICC catheter fixation device  3×9cm Peanut Shape
A0309R PICC catheter fixation device  3×9cm Airplane type
A0309F PICC catheter fixation device  3×9cm Airplane type
B0309 Epidural fixation device  3×9cm tear on both sides
B0607 Indwelling needle fixation device 6×7cm
C0309 Catheter Fixation Device  3×9cm belt buckle type
C0611 Catheter Fixation Device 6×11cm belt buckle type
C0611F Central venous catheter fixation device 6×11cm Aircraft Type
F0346 Endotracheal tube fixation belt 4.6cm long*3.2cm wide
F0609 Endotracheal tube fixing belt accessories 9×6-0.3cm foam
F1 Airway tube holder
L0308 Nasogastric feeding tube fixation device 3×8cm V-shaped
L0710 Nasogastric feeding tube fixation device 7×10cm L-shaped
D0309 PICC catheter fixation device 3×9cm Silolock
C0812 Catheter Fixation Device 8×12cm gourd shape
B0812 Drainage tube fixation device 8×12cm gourd shape
F0556 Drainage tube and urinary catheter fixation 4.8CM wide*56Cm long
TouchTymp MI 36 combines diagnostic middle ear analyzer and audiometry tests in one exceptional device. The full 10.4" touchscreen with its user-friendly interface guarantees a unique intuitive operation and allows to quickly change parameters. You can easily switch between the tests without reorganizing from one to another device and beneft from its small footprint when facing limited desk space. touchTymp MI 36 really improves your workflow every day. FEATURES AT A GLANCE
  • Combo device with small footprint
  • Customizable to suit individual needs
  • High resolution and quick screen transitions
  • Full touch-based interface for intuitive handling
  • Probe tone 226 Hz, 678 Hz, 800 Hz
  • Optional high-frequency probe tone 1 kHz
  • Acoustic reflex stimuli 500 Hz,1 kHz, 2 kHz, 4 kHz, BB, HP, LP (ipsilateral and contralateral)
  • Reflex Decay test (ipsilateral and contralateral)
  • ETF test for intact and perforated eardrums
  • Air conduction audiometry
  • Bone conduction audiometry
  • Built-in printer or data transfer to PC
  • Optional MAICO Sessions PC Software connectable with OtoAccess® or Noah patient database for easy data management
Comprehensive test protocols
  • Our touchTymp MI 36 provides comprehensive standard protocols for immediate operation of screening and diagnostic test processes: tympanometry with 226 Hz, tympanometry with automatic or fxed acoustic reflexes, reflex decay, Eustachian tube function testing (ETF) plus air conduction and bone conduction audiometry. The optional high-frequency probe tone of 1 kHz is ideal for providing reliable results when testing newborns
Stay focused on your patients
  • The unique touchTymp light bar on our shoulder box probe provides a real-time progression of the immittance test. The shoulder box can easily be clipped to your patient's top for controlled handling of the diagnostic probe. The light indicator shows you which ear is tested and the test result.
Printing made easy
  • Print test results instantly by using the touchTymp built-in printer. Place the shoulder box into its holder to automatically start printing. You can transfer the results to a PC to allow long term storage, full page printout and PDF creation for EMR integration.
Compatible to Sessions: Get ready for fast data transfer!
  • Use the touchTymp MI 36 with our intuitive data transfer solution Sessions, for easy management and visualization of your immittance measurements.
  TECHNICAL SPECIFICATION Tympanometry
  • Probe Frequency - 226 Hz ± 1 %, 85 dBSPL ± 1.5 dB, 678 Hz ± 1%, 72 dBSPL ± 1.5 dB, 800 Hz ± 1%, 70.5 dBSPL ± 1.5 dB
  • Optional High Frequency - 1 kHz ± 1%, 69 dBSPL ± 1.5 dB
  • Pressure Range - -600 to + 400 daPa
  • Accuracy of Pressure - ± 5 % or ± 10 daPa
  • Volume Range - 0.0 to 6.0 ml (compensated)
  • Compliance Range - 0.1 to 8.0 ml at 226 Hz, 0.1 to 15.0 mmho at 678, 800 and 1000 Hz
  • Accuracy of Volume - ± 5 % or 0.1 ml
  • Test Time Measurement - 3 - 5 seconds
Acoustic Reflexes
  • Test Frequencies - 0.5, 1, 2, 4 kHz ± 1 %
  • Test Noise - BB, LP, HP
  • Test Methods - Ipsilateral, contralateral
  • Level Ipsilateral - 70 to 105 dBHL
  • Level Contralateral - 70 to 120 dBHL
  • Level Setting - Automatic, fxed
  • Ipsilateral Reflex - Test With AGC
Reflex Decay
  • Standard - Probe frequency 226 Hz
  • Test Frequencies - 0.5, 1, 2, 4 kHz ± 1 %
  • Test Noise - BB, LP, HP
  • Level Ipsilateral - 70 to 105 dBHL
  • Level Contralateral - 70 to 120 dBHL
Eustachian Tube Function
  • Test Methods - Intact and perforated
  • Pressure Range - -600 to + 400 daPa
Audiometry
  • Test Signals - Sinus and warble tone, (pulsed and continuous)
  • Test Frequencies - 125, 250, 500, 750, 1000, 1500, 2000, 3000, 4000, 6000, 8000 Hz (125 Hz excluded
  • from bone conduction test frequencies)
  • Level Steps - 5 or 1 dB
  • Hearing Level Range AC - -10 to 120 dBHL
  • Hearing Level Range BC -  -10 to 80 dBHL
  • Masking Noise - Narrow band and white noise
Device General
  • Display - 10.4" Graphic LED-Display with resistive touchscreen
  • PC Interface - USB
  • Probe - Lightweight diagnostic Shoulder-Box with built-in control light and switch
  • Printer - Fast 4 inch thermal printer
  • Power Supply - Mains 100 to 240 V~ ± 10 %, 50 - 60 Hz ± 10 %
  • Dimensions / Weight - W 30 x D 34.5 x H 14.8 cm / 3.2 kg
  • Languages - English, German, Spanish, French, Polish, Turkish, Russian, Chinese
 
Click Here To Download Catalogue
De Lineb Oxygen Face Mask: This mask provides a method to transfer breathing oxygen gas from a storage tank to the lungs. Oxygen masks may cover only the nose and mouth (oral nasal mask) or the entire face (full-face mask).
Features:
  • Non-toxic PVC
  • Medium concentration
  • Adjustable nose clip
  • Non-Autoclavable
  • Available size: adult, child
  Technical Specifications:
  • Product Name: Oxygen Mask
  • Material: Medical grade PVC
  • Color: Green
  • Size: S, M, L, L , XL
  • Package: PE bag
  • Tube size: 2m
  • Nose Clip: adjustable
  • Disposable Medical Oxygen Face Mask Types MSLMK01
 
Bistos BT-770 is a 12.1" touchscreen patient monitor designed for easy operations. SPECIFICATIONS
  • 12.1“ color TFT touch screen
  • ECG, Resp., SpO2, NIBP, Temp., CO2, IBP, Multi-gas, C.O., Masimo SpO2
  • Precise ECG measurement with pacemaker detection ST segment and 16 types of arrhythmia analysis Double overpressure protection for NIBP Intelligent cuff inflation pressure adjustment
  • Smart Hook/Stand design, provide multiple placement modes Plug & Play Modular IBP& C.O., Modular Printer Multiple configuration options: 4-channel IBP, CO2, invasive C.O., Multi-gas Over 5 hours continuous working on battery 12-15V wide range DC input, suitable for ambulance Capable to connect with central monitoring system HL7 export to clinical information systems (option)
 
Click Here To Download Catalogue
Bistos BT - 720 Patient Monitor: Bistos Portable Patient Vital Signs Monitor, SpO2, Pulse, *NIBP, BT-720. The Bistos BT-720 is a compact size vital signs monitor with the standard parameters of SpO2 and Pulse. You can also add the NIBP and/or Masimo SpO2 at an additional cost. The BT-720 has a 4.3" color touch screen The PC software allows the vital signs information to be transferred and analyzed on a computer. Features:
  • 3" color touch screen
  • Standard Confirgurations: SpO2 and Pulse
  • Optioal NIBP and Masimo SpO2
  • Short/long trend graphic/trend table display
  • Audio and visual alarm, adjustable alarm limit
  • Automatic brightness adjustment
  • Accurate SpO2 reading during motion or low perfusion
  • Perfusion index data / bar graphic display
  • Pitch tone variation for pulse rate
  • Internal memory for data storage
  • SD card for easy software upgrade
  • Over 8 hours of operation with the re-chargeable li-ion battery
  • PC software for data review and analysis on a computer
  Technical Specifications:
Model BT-720
Display 4.3" Color LCD Touch Screen
SpO2 Measurement Range 0-100%
Accuracy (70-100%) Adult/Pediatric +/- 2%
Neonate +/- 3%
Accuracy (0-69%) Unspecified
Perfusion Index 0.05-20%
Pulse Rate Range (bpm) 25-250
NIBP* (Optional) Method Automatic Oscillometric
Operation Mode Manual/Automatic/STAT
Parameter Systolic/Diastolic/Mean
Systolic Range (mmHg) Adult 40-270
Pediatric 40-200
Neonate 40-130
Diastolic Range Adult 100-210
Pediatric 100-160
Neonate 10-90
Mean Range Adult 20-230
Pediatric 20-175
Neonate 20-100
SpO2 Masimo* (Optional) Masimo SpO2
Battery Type (Capacity) Li-ion (4400mAh)
Run time 8 Hours
Charging Time 8 Hours
Interface RJ45, SD Card Slot
Warranty 2 Years
 
Click Here To Download Catalogue
 
Integrated with SPO2 probe and processing display module • Small in volume, light in weight, convenient in carrying • Simple operation, lower power consumption • OLED screen display • SPO2, PR, bar graph of pulse, plethysmogram, blood perfusion index, battery indication display • 4 directions display, 6 display models, large fonts display • Brightness control, Demo mode, Setup menu • Movement interference • Alarm function and adjustable alarm parameters • Can be connected to mobile phones through Bluetooth; can support Android and iOS client • Auto power-off when no signal after 10s • Powered by 2*AAA alkaline batteries Specification: • Size: 62 x 37 x 32mm • Peak wavelength range of the light emitted from the probe: red light 660nm±3; infrared light 905nm±5 • Maximum optical output power of the probe: 1.2mW for infrared light (905nm) • Bluetooth module: 4.0 (single-mode) • Working temperature: 5℃ to 40℃ (41°F to 104°F) • Relative humidity: 15% to 80%, non-condensing • Atmospheric pressure: 70kPa to 106kPa • Rated voltage: DC 3V Package included: • 1 x JUMPER JPD-500F Bluetooth Fingertip Pulse Oximeter • 2 x AAA Batteries • 1 x Carry Case • 1 x Lanyard • 1 x English User Manual
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare