Neuro-IOM-32/B
$0.00
Shipped From Abroad
Neuro-IOM-32/B is an advanced Intraoperative Monitoring (IOM) system designed for real-time neurological monitoring during surgical procedures. It provides 32 channels of EMG, EEG, and Evoked Potentials (EP), enabling surgeons and neurophysiologists to monitor critical neural functions and detect any risks of neurological damage during surgery. With its high-resolution technology and user-friendly interface, the Neuro-IOM-32/B ensures patient safety by alerting medical teams to potential issues, helping to prevent nerve injury and ensuring optimal outcomes in complex surgeries.
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
System for Intraoperative Neurophysiological Monitoring with Advanced Functionality
Comprehensive solution for effective intraoperative neurophysiological monitoring
The standard configuration of Neuro-IOM (version 2) is the best solution for any type of neurological surgery. 32-channel amplifier and 4-channel transcranial electrical stimulator (up to 1000 V) with a wide range of pulse waveforms ensure the control of conduction pathways using motor evoked potentials even in the most complicated cases.
Main features:
- 64 amplifier inputs (32 bipolar channels);
- 2 dedicated channels for routine EMG, NCS and EP;
- 12 channels for electrical stimulation;
- 2 channels for direct nerve stimulation;
- 4 channels for transcranial electrical stimulation;
- auditory, visual and pattern stimulator channels;
- ES detector channels.
The Neuro-IOM system is equipped with the acquisition and stimulator pods to attach recording and stimulating electrodes with 5 m cables. It allows arranging the system at a distance from the operating table to ensure free movement for the surgical team. The set of specially-designed electrodes, a PC and the software are also included to the delivery set.
Motor, somatosensory, auditory and visual evoked potentials, EMG, direct nerve stimulation, EEG, ECoG — more than 10 modalities for intraoperative neurophysiological monitoring
The Neuro-IOM system is delivered with the preset templates ensuring the following modalities:
- direct nerve stimulation;
- free-run EMG;
- somatosensory evoked potentials (SEP);
- motor evoked potentials (MEP);
- auditory evoked potentials (AEP);
- visual evoked potentials (VEP);
- EEG;
- ECoG;
- direct cortical stimulation;
- train-of-four stimulation (TOF).
Using these modalities the surgical team can control motor and sensory pathways, monitor peripheral nerve integrity, assess the brain activity and perform mapping of its functional areas, etc.
Transcranial electrical stimulator (up to 1000 V), 12-channel electrical stimulator, low current stimulator, auditory and visual stimulators
Robust stimulators ensure high-quality responses during acquisition of brain evoked potentials and EMG exams.
Transcranial electrical stimulator deserves the special attention. It is intended for stimulation of motor cortex to record motor evoked potentials from muscles. The stimulator ensures single pulse and train stimulation, as well as double train and train + pulse stimulation. Different kinds of stimulation can also be performed using a built-in electronic switch.
Flexible configurations to ensure any monitoring needs
The Neuro-IOM.NET software provides a set of default templates for various types of surgeries. Each template includes the settings of modalities for a particular type of surgery, test window layouts, acquisition and stimulation parameters, etc. The system has a vast number of channels and stimulators with separate adjustment. Use of preset templates simplifies and speeds up the system setup for surgery.
You can always change and save the settings of any surgery template. It is a unique option for such kind of systems. There is no IONM system in the world that is so flexible
Applications
- Find monitoring templates for all types of surgery to start immediately
- Combine more than 10 modalities on one screen to capture critical information
- Use wide range of stimulation programs for automatic monitoring
- Get perfect MEP’s even in complicated conditions with powerful TES and it’s wide range of pulse waveforms
Quick Comparison
Settings | Neuro-IOM-32/B remove | Ectron Ectonustim Series 6 Electroconvulsive Therapy ECT Machine remove | Self-Retaining Retractor remove | Dolphin-IQ Transcranial Doppler Probe remove | Falcon-PRO Transcranial Doppler Probe remove | ND-8S EEG Monitor remove | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Name | Neuro-IOM-32/B remove | Ectron Ectonustim Series 6 Electroconvulsive Therapy ECT Machine remove | Self-Retaining Retractor remove | Dolphin-IQ Transcranial Doppler Probe remove | Falcon-PRO Transcranial Doppler Probe remove | ND-8S EEG Monitor remove | ||||||
Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ||||||
SKU | SF1033560130187-21 | SF10335601235 | SF1033560130176-10 | SF1033560130142-3 | SF1033560130142-5 | |||||||
Rating | ||||||||||||
Price |
|
|
| $6,325.00 |
|
| ||||||
Stock | ||||||||||||
Availability | ||||||||||||
Add to cart | ||||||||||||
Description | Shipped From Abroad
Neuro-IOM-32/B is an advanced Intraoperative Monitoring (IOM) system designed for real-time neurological monitoring during surgical procedures. It provides 32 channels of EMG, EEG, and Evoked Potentials (EP), enabling surgeons and neurophysiologists to monitor critical neural functions and detect any risks of neurological damage during surgery. With its high-resolution technology and user-friendly interface, the Neuro-IOM-32/B ensures patient safety by alerting medical teams to potential issues, helping to prevent nerve injury and ensuring optimal outcomes in complex surgeries.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
This machines have been developed from the well-proven Series 5A and 5B ECT apparatus. The series 6+ models incorporate all the features of the corresponding Series 5B versions. Experience has shown that a very few patients sometimes require higher dosage than was available with the earlier machines and the opportunity was therefore taken to produce equipment with a second, higher, output range. Delivery & Availability: Typically 3 Months – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped From Abroad
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
All of the advantages and performance of the cutting-edge Dolphin TCD technology for measurements of cerebral blood flow velocities are implemented in the smart and compact Dolphin/IQ Transcranial Doppler module.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
State-of-the-Art technology to measure Segmental Blood Pressures, ABI, TBI, Doppler, PVR, PPG and stress testing. Falcon advanced EMR and PACS capabilities and reporting options are designed for medical centers and private clinics alike. Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| ||||||
Content | System for Intraoperative Neurophysiological Monitoring with Advanced Functionalityhttps://youtu.be/XyI13InME9A?list=PLU2BvNtfeStPOl_izQJDwlLEi6eLCrDEF Comprehensive solution for effective intraoperative neurophysiological monitoring The standard configuration of Neuro-IOM (version 2) is the best solution for any type of neurological surgery. 32-channel amplifier and 4-channel transcranial electrical stimulator (up to 1000 V) with a wide range of pulse waveforms ensure the control of conduction pathways using motor evoked potentials even in the most complicated cases.Main features:
Applications
| This machines have been developed from the well-proven Series 5A and 5B ECT apparatus. The series 6+ models incorporate all the features of the corresponding Series 5B versions. Experience has shown that a very few patients sometimes require higher dosage than was available with the earlier machines and the opportunity was therefore taken to produce equipment with a second, higher, output range.
Features:
Constant Current stimulus
Delivered Dosage Displayed
Patient Dynamic Impedance Indicator
Simple Single Dose Control
Technical Specification:
Input Supply: AC 100-120, 210-240 V 40/60 Hz
Load: 70 W
Apparatus Size: 305 x 170 x 105mm (12” x 6.5” x 4”)
Weight: 3.24kg
Low Range: 50-700mC @ 750mA
High Range: 200-100mC @ 900mA
Contents:
Two-hand headpiece: 1
C.S lead: 1
Disposable electrodes: 50
Mains cable: 1
Operating & service manual: 1
Removable stand: 1
Click Here To Download Catalogue |
| https://youtu.be/Id0Ma1_lEo0?si=kRJ1bUMjUCBuCAqR
Features of Dolphin TCD Machine | https://youtu.be/YSWvhSIS1ho?si=ZVl2aB_GXgSRotbP
Features of Falcon Physiologic Machine | FeaturesHIE multi-dimensional identification and application 1) According to the amplitude and continuity of the upper/lower boundary of aEEG, the neonatal EEG activity will be classified, and the Hellstrom-Westas background five-classification method will be used to improve the ability of medical staff to identify the aEEG waveforms; 2) Masimo Rainbow SET pulse oximetry monitoring, monitor the SpO2/PI/PR change in a non-invasive and continuous manner, effectively eliminate the exercise interference, and improve the measurement performance under low perfusion and body motion.
| ||||||
Weight | N/A | N/A | N/A | N/A | N/A | N/A | ||||||
Dimensions | N/A | N/A | N/A | N/A | N/A | N/A | ||||||
Additional information |
Reviews
There are no reviews yet.