Neuro-IOM-32/S is a sophisticated intraoperative monitoring (IOM) system designed for real-time neurological assessment during surgeries. It offers 32 channels for EMG, EEG, and Evoked Potentials (EP), ensuring continuous monitoring of neural functions. This system helps in identifying potential neurological risks during complex surgeries, allowing surgeons and neurophysiologists to make informed decisions and prevent neural damage. With high-resolution diagnostics and a user-friendly interface, the Neuro-IOM-32/S enhances patient safety and optimizes surgical outcomes.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130187-22
Brands:: Neurosoft

Description

32-channel System with Basic Functions for Intraoperative Neurophysiological Monitoring

 

 

32 bipolar channel system, entry level

This configuration of Neuro-IOM system (version 2) includes all basic functions to perform intraoperative neurophysiological monitoring

Main features:

  • 64 amplifier inputs (32 bipolar channels)
  • 32-channel amplifier significantly improves the quality of IONM as more conduction pathways are monitored in comparison with 16-channel amplifier.
  • 2 dedicated channels for routine EMG, NCS and EP;
  • 4 electrical stimulator channels;
  • direct nerve stimulation channel;
  • auditory, visual and pattern stimulator channels;
  • ES detector channels.

The Neuro-IOM system allows performing intraoperative neurophysiological monitoring of all modalities, including MEP acquisition using the electrical stimulator with current intensity of up to 200 mA.

The Neuro-IOM system is equipped with the acquisition and stimulator pods to attach recording and stimulating electrodes with 5 m cables. It allows arranging the system at a distance from the operating table to ensure free movement for the surgical team. The set of specially-designed electrodes and the software are also included to the delivery set.

Motor, somatosensory, auditory and visual evoked potentials, EMG, direct nerve stimulation, EEG, ECoG — more than 10 modalities for intraoperative neurophysiological monitoring

The Neuro-IOM system is delivered with the preset templates ensuring the following modalities:

  • direct nerve stimulation;
  • free-run EMG;
  • somatosensory evoked potentials (SEP);
  • motor evoked potentials (MEP);
  • auditory evoked potentials (AEP);
  • visual evoked potentials (VEP);
  • EEG;
  • ECoG;
  • direct cortical stimulation;
  • train-of-four stimulation (TOF).

Using these modalities the surgical team can control motor and sensory pathways, monitor peripheral nerve integrity, assess the brain activity and perform mapping of its functional areas, etc.

Flexible configurations to ensure any monitoring needs

The Neuro-IOM.NET software provides a set of default templates for various types of surgeries. Each template includes the settings of modalities for a particular type of surgery, test window layouts, acquisition and stimulation parameters, etc. The system has a vast number of channels and stimulators with separate adjustment. Use of preset templates simplifies and speeds up the system setup for surgery.

You can always change and save the settings of any surgery template. It is a unique option for such kind of systems. There is no IONM system in the world that is so flexible!

Applications
  • SEP acquisition
  • MEP acquisition
  • 64 amplifier inputs( 32 bipolar channels)
  • auditory and visual evoked potentials, EMG, direct nerve stimulation, EEG, ECoG — more than 10 monitoring modalities
  • flexible configurations to ensure any monitoring needs

 

Download Brochure

Reviews

There are no reviews yet.

Be the first to review “Neuro-IOM-32/S”

Your email address will not be published. Required fields are marked *

Quick Comparison

Neuro-IOM-32/S removeBRAINSWAY Deep TMS H1 Coil removeBRAINSWAY Deep TMS H4 Coil removeVentMed DF-30V-HM BiPAP removeFalcon-PRO Transcranial Doppler Probe removeBRAINSWAY Deep TMS 104 RCT System remove
NameNeuro-IOM-32/S removeBRAINSWAY Deep TMS H1 Coil removeBRAINSWAY Deep TMS H4 Coil removeVentMed DF-30V-HM BiPAP removeFalcon-PRO Transcranial Doppler Probe removeBRAINSWAY Deep TMS 104 RCT System remove
Image
SKUSF1033560130187-22SF1033560130162-4SF1033560130162-7SF1033560130180-2SF1033560130142-5SF1033560130162-3
Rating
Price

$0.00

$0.00

$0.00

$0.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad Neuro-IOM-32/S is a sophisticated intraoperative monitoring (IOM) system designed for real-time neurological assessment during surgeries. It offers 32 channels for EMG, EEG, and Evoked Potentials (EP), ensuring continuous monitoring of neural functions. This system helps in identifying potential neurological risks during complex surgeries, allowing surgeons and neurophysiologists to make informed decisions and prevent neural damage. With high-resolution diagnostics and a user-friendly interface, the Neuro-IOM-32/S enhances patient safety and optimizes surgical outcomes.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
The H1 Coil stimulates the bilateral prefrontal cortex, with a preference for the left dorsolateral prefrontal cortex. In addition to numerous published, double-blind, randomized controlled trials validating the efficacy of Deep TMS for depression, clinical data of over 1,000 patients in real practice settings has shown compelling results. Among patients who completed 30 sessions, approximately 4 out of 5 achieved a clinical response, and approximately 2 out of 3 achieved remission from depression.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad The H4 Coil stimulates the bilateral insula and prefrontal cortex. Nearly 1 in 3 patients who completed 18 sessions achieved 4 or more weeks of abstinence from smoking in a large scale, double-blind, multicenter randomized controlled trial. 2 out of 3 patients who quit smoking by the end of treatment remained abstinent for at least an additional three months
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad The VentMed DF-30V-HM is a BiPAP (Bilevel Positive Airway Pressure) machine designed for sleep apnea therapy and non-invasive ventilation. It is ideal for individuals with obstructive sleep apnea (OSA), central sleep apnea (CSA), chronic obstructive pulmonary disease (COPD), and other respiratory disorders.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad

State-of-the-Art technology to measure Segmental Blood Pressures, ABI, TBI, Doppler, PVR, PPG and stress testing. Falcon advanced EMR and PACS capabilities and reporting options are designed for medical centers and private clinics alike.

Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad BrainsWay's 104 RCT System enables blinded clinical research via a card reader that randomizes selection of sham or Deep TMS stimulation. The sham coil is integrated into the helmet with the treatment coil, producing similar sounds and sensations.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
32-channel System with Basic Functions for Intraoperative Neurophysiological Monitoring
  https://youtu.be/XyI13InME9A?list=PLU2BvNtfeStPOl_izQJDwlLEi6eLCrDEF   32 bipolar channel system, entry level This configuration of Neuro-IOM system (version 2) includes all basic functions to perform intraoperative neurophysiological monitoring Main features:
  • 64 amplifier inputs (32 bipolar channels)
  • 32-channel amplifier significantly improves the quality of IONM as more conduction pathways are monitored in comparison with 16-channel amplifier.
  • 2 dedicated channels for routine EMG, NCS and EP;
  • 4 electrical stimulator channels;
  • direct nerve stimulation channel;
  • auditory, visual and pattern stimulator channels;
  • ES detector channels.
The Neuro-IOM system allows performing intraoperative neurophysiological monitoring of all modalities, including MEP acquisition using the electrical stimulator with current intensity of up to 200 mA. The Neuro-IOM system is equipped with the acquisition and stimulator pods to attach recording and stimulating electrodes with 5 m cables. It allows arranging the system at a distance from the operating table to ensure free movement for the surgical team. The set of specially-designed electrodes and the software are also included to the delivery set. Motor, somatosensory, auditory and visual evoked potentials, EMG, direct nerve stimulation, EEG, ECoG — more than 10 modalities for intraoperative neurophysiological monitoring The Neuro-IOM system is delivered with the preset templates ensuring the following modalities:
  • direct nerve stimulation;
  • free-run EMG;
  • somatosensory evoked potentials (SEP);
  • motor evoked potentials (MEP);
  • auditory evoked potentials (AEP);
  • visual evoked potentials (VEP);
  • EEG;
  • ECoG;
  • direct cortical stimulation;
  • train-of-four stimulation (TOF).
Using these modalities the surgical team can control motor and sensory pathways, monitor peripheral nerve integrity, assess the brain activity and perform mapping of its functional areas, etc. Flexible configurations to ensure any monitoring needs The Neuro-IOM.NET software provides a set of default templates for various types of surgeries. Each template includes the settings of modalities for a particular type of surgery, test window layouts, acquisition and stimulation parameters, etc. The system has a vast number of channels and stimulators with separate adjustment. Use of preset templates simplifies and speeds up the system setup for surgery. You can always change and save the settings of any surgery template. It is a unique option for such kind of systems. There is no IONM system in the world that is so flexible!
Applications
  • SEP acquisition
  • MEP acquisition
  • 64 amplifier inputs( 32 bipolar channels)
  • auditory and visual evoked potentials, EMG, direct nerve stimulation, EEG, ECoG — more than 10 monitoring modalities
  • flexible configurations to ensure any monitoring needs
  Download Brochure
The BrainsWay Deep TMS H1 Coil is a transcranial magnetic stimulation (TMS) device that's used to treat depression and other mental disorders: 
  • Design
    The H1 Coil is a flexible, soft copper coil that's placed inside a helmet to stimulate the brain. The coil's design allows for a wider and deeper distribution of magnetic fields than traditional TMS coils.
  • Effectiveness
    The H1 Coil is effective in treating depression and has also been explored as a treatment for other conditions:
    • DepressionThe H1 Coil is FDA-cleared to treat major depressive disorder (MDD) in adults who haven't responded well to other antidepressant medications.
    • Other conditionsThe H1 Coil has been explored as a treatment for negative symptoms of schizophrenia, bipolar depression, and migraine.
  • Benefits
    The H1 Coil's design allows for greater neuron activation, which can lead to more effective stimulation and fewer targeting errors.
  • Safety
    The H1 Coil is considered a safe and effective clinical tool.
Features
  • Flexible base
    The H1 coil has a flexible base that can adapt to the shape of the patient's head. 
  • Tangential coil components
    The H1 coil has tangential coil components that are close to the brain targets. 
  • Parallel coil components
    The H1 coil has parallel coil components that direct the electric pulse beams. 
  • Electrical pulses
    The H1 coil has numerous electrical pulses that converge from various directions. 
  • Return paths
    The return paths of the electrical pulses are located at a distance from the target area. 
  • Stimulates the prefrontal cortex
    The H1 coil stimulates the bilateral prefrontal cortex, with a preference for the left dorsolateral prefrontal cortex (DLPFC). 
  • Deeper and broader stimulation
    The H1 coil's patented design enables deeper and broader stimulation than traditional TMS coils.
    Click here to download Brochure
The BrainsWay Deep TMS H4 Coil is a non-invasive treatment that uses magnetic energy waves to stimulate brain structures associated with addiction and weight loss: 
  • Treatment
    The H4 Coil is used to treat smoking addiction and weight loss. It generates electromagnetic pulses that stimulate the bilateral insula and prefrontal cortex of the brain.
  • Benefits
    Deep TMS is a well-tolerated treatment that can be integrated into a patient's daily schedule. It's said to have no side effects and no recovery period. Patients may start to feel relief from symptoms within a few weeks.
  • Technology
    The H4 Coil is part of a helmet that contains BrainsWay's patented H-Coils, which are designed to stimulate deeper and broader areas of the brain than traditional TMS coils. The helmet also has a touchscreen interface, adjustable positioning arm, and cooling system.
  • Safety
    The H4 Coil has lower rates of headache, treatment site discomfort, and jaw pain than other coils, but higher rates of general discomfort

Click here to download Brochure

This portable and home-use BiPAP device offers effective sleep therapy and is suitable for patients who require advanced respiratory support
Key Features:
  • Bi-Level Pressure Support: Provides different pressure settings for inhalation (IPAP) and exhalation (EPAP) to enhance breathing comfort.
  • Auto-Adjusting Therapy: Automatically adjusts pressure levels based on the user’s breathing needs.
  • Integrated Humidifier: Prevents dryness and irritation in the airways.
  • Real-Time Monitoring: Displays SpO2 (blood oxygen levels), pulse rate, and therapy data.
  • User-Friendly Interface: Features a full-color display and intuitive controls.
  • Quiet Operation: Low noise level for a comfortable sleep experience.
  • Data Storage & Connectivity: Compatible with SD card storage for tracking sleep therapy progress.
Specifications:
Feature Details
Modes APCV, Auto BiPAP, Auto S, CPAP, S, ST, T
Pressure Range 4 - 30 cmH₂O
Weight 1.7 kg (including humidifier)
Tubing Heated tube
Tidal Volume 200 mL - 1200 mL
Backup Rate 5 bpm - 60 bpm
Humidity Levels 1 - 5 levels (heating & humidification)
Alarms Mask off, pressure & tube abnormalities

This BiPAP machine is user-friendly, featuring an intuitive control panel and a clear display, making setup and adjustments easy for both patients and healthcare providers. It ensures stable breathing throughout the night, improving overall sleep quality

https://youtu.be/YSWvhSIS1ho?si=ZVl2aB_GXgSRotbP
Features of Falcon Physiologic Machine

Segmental Blood Pressures

Measure lower extremity pressures easily with 10 color-coded channels and a variety of Doppler probes and PPG sensors. Complete the vascular diagnosis with supportive stress testing. Falcon is considered by many the best segmental pressure machine with numerous advanced features such as 10 simultaneous PVR measurements and limitless post-processing capabilities.

Fast and Accurate ABI & TBI

Quickly measure ABI and TBI with either Doppler or Photoplethysmography (PPG). With the Falcon ABI and TBI machine, all measurements are saved automatically and sent directly to the dedicated interactive summary screen.

High Quality Doppler Probes

In addition, to the 4 MHz and 8 MHz probes for standard use, the advanced Falcon Doppler machine offers a unique 10 MHz probe, which is designed to measure particularly small peripheral blood vessels. All Falcon Doppler probes produce complete high-resolution Doppler spectral analysis with the aid of the Falcon vascular software and algorithms.

State-of-the-Art PPG Sensors

Falcon offers a wide selection of Photoplethysmography sensors.   The 5 completely independent PPG ports allow simultaneous fingers/toes measurements, which is especially useful for Raynaud’s diagnosis along with a an integrated temperature sensor.  Fingerclip and Toeclip PPG sensors are recommended for routine examinations. The Disc PPG sensors are particularly useful for Venous Reflux testing and are supplied with dedicated adhesive stickers.

Highest Durability and Reliability

The Falcon is the most reliable peripheral vascular machine in the market.  Thanks to the high quality Doppler probes, 10 Independent Pressure Channels (IPU Technology) and 5 PPG Ports, the Falcon design significantly reduces any down-time. Falcon is in distributed worldwide for over 10 years with the lowest fail rate in the market!

Complete Network Connectivity

The Falcon unmatched connectivity capabilities are a paradise to hospital IT personnel and EMR and PACS managers. The advanced networking abilities allow a plug-and-play operation to easily configure connectivity with automated DICOM Worklist & Storage, Structured Report, and HL7. With unlimited Review Stations, measurements can be reanalyzed and interpreted from the comfort of your office. Final reporting can also be configured and finalized from any location.

Simplify Your Workflow

The Falcon vascular diagnosis device has the ability to configure as many dedicated examination protocols that allow to save time and optimize the patient vascular diagnosis​. Enjoy the user-friendly protocol builder to configure your workflow according to your needs!​

Ease of Use

Minimal learning curve thanks to user-friendly software with a large touch-screen display. A selection of wired and wireless remote control​ and footswitch allows keeping your focus on the patient rather than on the physiologic vascular equipment.

Dedicated Specialty Tests

The Falcon is the complete vascular physiologic assessment machine with dedicated protocols that guide you through step-by-step diagnostic measurements of specific vascular conditions.  The dedicated diagnosis protocols include measurements of Thoracic Outlet Syndrome (TOS), diagnosis of Raynaud’s Phenomenon, evaluation of Penile Function or Erectile Dysfunction, assessment of Allen’s Test (or Palmar Arch Test), measurements of Venous Reflux and Venous Capacitance and Outflow, Pulse Wave Velocity, and more.

Advanced Reporting

The famous Falcon user-friendly report builder tool allows you to design your own report layout easily. Then, add your institute/clinic logo and details to create a detailed and impressive diagnosis report that meets your institute standards. Save a lot of time by building your report with preconfigured interpretation templates.

Advanced Research Options

The Falcon vascular research machine is famous for its built-in statistics tool with on-screen graphs, segments filtering, and Excel tool, which are all designed to simplify the work of vascular and physiological researchers. Export to PDF, Excel, Word, JPEG, VSX, Video clips, and more to support your vascular research and teaching needs, as well as support your clinical vascular publications.
The BrainsWay Deep TMS 104 RCT System is a non-invasive treatment for mental health conditions that uses magnetic pulses to stimulate the brain.
  • ComponentsIncludes a stimulator, touchscreen interface, cooling system, and card reader 
  • TreatmentPatients wear a helmet with electromagnetic coils that deliver magnetic pulses to the brain 
  • PurposeTreats conditions like major depressive disorder (MDD), obsessive-compulsive disorder (OCD), and smoking cessation 
  • SafetyWell-tolerated treatment with a favorable safety profile 
  • EffectivenessResearch shows that Deep TMS is effective in alleviating symptoms 
  • InsuranceMany insurance providers offer coverage for Deep TMS 
  • Ease of useDesigned to be easy to use for operators and comfortable for patients 
  • Sham-enabledVersions are available for randomized controlled clinical research 
 
Features
The BrainsWay Deep TMS 104 RCT System has several features, including:
  • H-CoilsThe system's patented H-Coils are flexible and embedded in a cushioned, cooled helmet that fits each patient's head. The H-Coils provide deeper and broader stimulation than traditional TMS coils, which are rigid and shaped like a figure-8. 
  • Touchscreen interfaceThe system has an intuitive touchscreen interface. 
  • Cooling systemThe system has an efficient cooling system. 
  • Card readerThe system has a card reader that randomly selects sham or Deep TMS stimulation. 
  • Sham-enabled versionsSham-enabled versions are available for randomized controlled clinical research.
 

Click here to download Brochure 

WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare