NEURO-MEP-8-EMG, NCS and EP System
$0.00
Shipped From Abroad
Research institutions conducting EMG and EP studies sometimes apply rarely used techniques such as long loop reflex, nociceptive flexor reflex (RIII reflex), triple stimulation, paired associative stimulation and others. That is why it is important that they are implemented in the device. 8-channel NCS, EMG and multi-modality EP system of expert class Neuro-MEP-8 is perfect for this purpose.
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
Features
Modular design
Neuro-MEP-8 system features modular design which means that you can create a configuration of your own combining amplifiers and stimulators included in the system depending on your specific needs. All electronic units can be connected to a computer via USB. It is possible to connect up to 10 different USB units whereas the system itself can be expanded up to 16 bipolar channels using an additional amplifier (purchased separately).
69 different EMG, EP and ERG techniques
Neuro-MEP-8 is a versatile tool packed with 69 different EMG, TMS, EP (including cognitive), ERG and EOG techniques.
Video EMG
The system ensures synchronous recording and reviewing of EMG data together with video including that obtained from the laryngoscope and other endoscopes.
Amplifiers and stimulators with fully customizable settings
Fully customizable settings of amplifiers and stimulators, possibility to create user-defined examination types and the most complex stimulation and biosignal (macros) acquisition protocols is truly unrivaled.
Native data export in .xml, .edf, .bdf and text formats
No matter if you use different methods of data processing, you can always export the data in various formats and process it using your own mathematics software.
Quick Comparison
| NEURO-MEP-8-EMG, NCS and EP System remove | Dolphin-MAX Transcranial Doppler Probe remove | Dolphin-XF Transcranial Robotic Probe remove | RESCUE LIFE 9 AED DEFIBRILLATOR with Temp, Spo2, Pacemaker remove | Self-Retaining Retractor remove | BRAINSWAY Deep TMS H7 RCT Coil remove | |||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Name | NEURO-MEP-8-EMG, NCS and EP System remove | Dolphin-MAX Transcranial Doppler Probe remove | Dolphin-XF Transcranial Robotic Probe remove | RESCUE LIFE 9 AED DEFIBRILLATOR with Temp, Spo2, Pacemaker remove | Self-Retaining Retractor remove | BRAINSWAY Deep TMS H7 RCT Coil remove | ||||||
| Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ||||||
| SKU | SF1033560130187-17 | SF1033560130142-2 | SF1033560130142-4 | SF10335601298-1 | SF1033560130176-10 | SF1033560130162-6 | ||||||
| Rating | ||||||||||||
| Price |
|
| $6,270.00 |
|
|
| ||||||
| Stock | ||||||||||||
| Availability | ||||||||||||
| Add to cart | ||||||||||||
| Description | Shipped From Abroad
Research institutions conducting EMG and EP studies sometimes apply rarely used techniques such as long loop reflex, nociceptive flexor reflex (RIII reflex), triple stimulation, paired associative stimulation and others. That is why it is important that they are implemented in the device. 8-channel NCS, EMG and multi-modality EP system of expert class Neuro-MEP-8 is perfect for this purpose.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Transcranial Doppler machine with an integrated rechargeable battery. The Dolphin/MAX is the ideal portable TCD system for measurements of cerebral blood flow in Neurology, ICU, and Neurosurgery settings
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Proudly introducing the X-Factor in TCD robotic solutions, assisting in obtaining bilateral TCD insonations in as quickly as just a few seconds!. Designed for short and long-term monitoring, for use in anesthesia, in the ICU, or in the TCD lab.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Lightweight, ergonomic, attractive and robust portable device. Rescue Life 9 provides complete monitoring of parameters like 12 channels ECG, HR, SpO2, NIBP, Temperature and EtCO2. Synchronized cardioversion and external pacemaker in fixed or demand mode.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
The H7 Coil stimulates the anterior cingulate cortex and the medial prefrontal cortex. Treatment is designed to regulate the CSTC circuit believed to be involved in the inhibition of impulsive behavior. A sham coil is integrated above the treatment coil. To the patient and operator, the helmet appears the same, pulses sound the same, and stimulation feels the same on the scalp.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| ||||||
| Content | FeaturesModular design Neuro-MEP-8 system features modular design which means that you can create a configuration of your own combining amplifiers and stimulators included in the system depending on your specific needs. All electronic units can be connected to a computer via USB. It is possible to connect up to 10 different USB units whereas the system itself can be expanded up to 16 bipolar channels using an additional amplifier (purchased separately). 69 different EMG, EP and ERG techniques Neuro-MEP-8 is a versatile tool packed with 69 different EMG, TMS, EP (including cognitive), ERG and EOG techniques. Video EMG The system ensures synchronous recording and reviewing of EMG data together with video including that obtained from the laryngoscope and other endoscopes. Amplifiers and stimulators with fully customizable settings Fully customizable settings of amplifiers and stimulators, possibility to create user-defined examination types and the most complex stimulation and biosignal (macros) acquisition protocols is truly unrivaled. Native data export in .xml, .edf, .bdf and text formats No matter if you use different methods of data processing, you can always export the data in various formats and process it using your own mathematics software. Download Brochure |
https://youtu.be/Id0Ma1_lEo0?si=-B5sGwSCDZOQi-ZO
Features of Dolphin TCD Machine | https://youtu.be/JwSJvUVJrxo?si=6QkpitWAwvZZSwOM
DescriptionThe Dolphin/XF is a new breakthrough development in TCD robotics. It is designed to assist the user in quickly and automatically insonating and monitoring cerebral blood flow.Features | Progetti Rescue Life 9 is designed for out-of-hospital and hospital use.
Lightweight, ergonomic, attractive and robust portable device. Rescue Life 9 provides complete monitoring of parameters like 12 channels ECG, HR, SpO2, NIBP, Temperature and EtCO2. Synchronized cardioversion and external pacemaker in fixed or demand mode. Three operating modes: manual, AED, Advisory. Capnography waveform. Auto-test mode verifies device functions, battery status and charge-discharge system with real-time data management and report printing. The IPX4 permits operations under adverse climatic situations.
Rescue Life 9 Technical Specification:
General requirements
• Dimension: 335x225x360 mm
• Weight: 6.5 kg with dual batteries
• Electrical: AC 100-240 VAC, 50/60 Hz
• Rechargeable Lithium-ion batteries: 15.0 V - 3.2 Ah
• Battery Operation Time:
>5 hours, with 1 battery
>10 hours with 2 batteries
• Charge Time: Max. 3 hours
• Capacity: 150 shocks with 1 battery or 300 shocks with 2 batteries at 230J fully charged
• Software: Voice and text multi-language
• Memory: Internal flash for ECG data, events and usage review
Defibrillation
• Waveform: Biphasic Truncated Exponential (BTE), HiCAP technology (Large storage capacitor)
• Impedance: Compensated, range 25-200 Ohm
• Charge time: 6 sec for 230 J with the battery fully charged
AED mode
• Energy: Fixed energy at 200 J
• Protocol: ERC 2015 CPR Guidelines with voice and text prompts
• Shockable rhythms: VF with amplitude > 0.15 mV and VT with rhythm >150 bpm
• Sensitivity: Shockable rhythm -VF > 95%, -VT > 75%
• Specificity: According to ERC 2015,
• Normal sinusoidal rhythm > 99%
• Asystole and other non-shockable rhythms > 99%
Manual mode
• Energy range: 1-230 J (from 1-10 J in 1 J steps; from 10 to 230 J in 10 J steps)
• Commands: Multifunction trim knob
• Charge and shock button in the front panel
• Operating mode: EC G «R» wave synchro or async mode
• Indicators: Battery and main led indicators
Display
• Type: High contrast TFT colour LCD 8” (800x600 dots)
• Information: ECG traces, SpO2, NIBP, EtCO2, TEMP, Heart Rate indicator, filters, alarms and the batteries status
• Display mode: Can select 3, 6, 12 ECG leads
Ecg monitoring
• Bandwidth:
0.05 - 120 Hz (-3 db) in diagnostic mode
0.6 - 40 Hz (-3 db) in monitoring mode
• CMRR: > 98 dbv Input impedance: > 50 Mohm
• Input:
Patient cable 5 leads (I, II, III, aVL, aVF, aVR, V) - standard
Patient cable 10 leads (I, II, III, aVL, aVF, aVR, V1…..V6) - optional
• Speed: 5, 10, 25, 50 mm/sec
• Filters: 50/60 Hz, EMG Filter, base line
• HR range: 20-300 bpm (~2%), digital readout on the display
• Alarm: HR max settable 250 bpm; HR min 20 bpm
SpO2 (only 55505-55512)
• SpO2 range: 0-100% HR range: 30-250 bpm
• Accuracy: 70-100% ~2% for adults with finger clip sensor
• Alarm: Adjustable min 50%
Temperature
• Probe type: YSI400 compatible
• Range: 0 to 50° C
• Resolution: ±0.1° C
Standard
• IEC 60601-2-4; IEC 60601-1; IEC 60601-1-2; IEC 63204, IEC 62366-1
• CE Mark EEC 93/42: Medical device, Class IIb
• Isolation: ECG type CF, Defibrillation type BF
• Waterproof: Class IP54
|
| The Brainsway Deep TMS H7 RCT Coil is a flexible coil used in transcranial magnetic stimulation (TMS) to treat obsessive-compulsive disorder (OCD) and other neuropsychiatric conditions:
Features
| ||||||
| Weight | N/A | N/A | N/A | N/A | N/A | N/A | ||||||
| Dimensions | N/A | N/A | N/A | N/A | N/A | N/A | ||||||
| Additional information |










Reviews
There are no reviews yet.