Neuron Spectrum 61..65 EEG

$0.00

Shipped From Abroad

The Neuron-Spectrum 61–65 EEG series offers advanced neurophysiological diagnostic systems with 11 to 39 channels, supporting ICU monitoring, routine EEG, long-term video EEG, and polysomnography. These systems feature real-time impedance monitoring, multimodal stimulation, and high-quality data acquisition for clinical and research applications.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130187-1
Brands:: Neurosoft

Description

 

Features

Flexible software

The advantage of the Neuron-Spectrum.NET software is its wide functionality. You can use the simple interface, or you can customize the software using the special settings.

Before the study, you may choose the pre-defined electrode montage or create your own one depending on the type of test you perform. Using the convenient navigation tools, you can quickly view the recorded EEG curves, highlight artifacts, and arrange epochs. For the advanced analysis of recorded data, the contemporary tools for mathematical analysis of EEG are used. The automatic report is generated using the preset report templates and integrated glossary. The report is easily edited, saved to PDF, printed or sent automatically.

Electrode impedance indication at the lead inputs

The impedance indicators on the amplifier ensure the continuous impedance monitoring during the acquisition, timely correction of electrode placement and good quality of EEG recording.

Operation mode can be switched with just one button on the front panel. The LED indicator next to the button shows the mode: acquisition, EEG monitoring or impedance measurement. It makes the EEG study much easier.

Electrodes and caps of various manufacturers

During the study, the disk, cup and bridge electrodes as well as the electrode caps of different sizes can be applied. They are connected to the amplifier unit via touch-proof connectors and standard plug.

Operation in unshielded environments

The EEG systems of Neuron-Spectrum line can be used in any suitable room, which is convenient for staff and comfortable for patients. The costs for preparing a specialist’s workplace are also reduced significantly. The device is small and USB powered, so you can establish your EEG lab anywhere.

Download Brochure

Reviews

There are no reviews yet.

Be the first to review “Neuron Spectrum 61..65 EEG”

Your email address will not be published. Required fields are marked *

Quick Comparison

Neuron Spectrum 61..65 EEG removeBRAINSWAY Deep TMS H4 RCT Coil removeNitrogen Generator/Plant removeSomatics Electroconvulsive Therapy (ECT) Machine removeEctron Ectonustim Series 6 Electroconvulsive Therapy ECT Machine removeVentMed DF-30V-HM BiPAP remove
NameNeuron Spectrum 61..65 EEG removeBRAINSWAY Deep TMS H4 RCT Coil removeNitrogen Generator/Plant removeSomatics Electroconvulsive Therapy (ECT) Machine removeEctron Ectonustim Series 6 Electroconvulsive Therapy ECT Machine removeVentMed DF-30V-HM BiPAP remove
Image
SKUSF1033560130187-1SF1033560130162-8SF103356013077SF1033560106-1SF10335601235SF1033560130180-2
Rating
Price

$0.00

$0.00

$0.00

$0.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad The Neuron-Spectrum 61–65 EEG series offers advanced neurophysiological diagnostic systems with 11 to 39 channels, supporting ICU monitoring, routine EEG, long-term video EEG, and polysomnography. These systems feature real-time impedance monitoring, multimodal stimulation, and high-quality data acquisition for clinical and research applications.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad The H4 Coil stimulates the bilateral insula and prefrontal cortex. This includes neurons in brain structures associated with addiction. A sham coil is integrated above the treatment coil. To the patient and operator, the helmet appears the same, pulses sound the same, and stimulation feels the same on the scalp.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
PSA Industrıal nitrogen generator systems produce gas nitrogen from compressed air from the field where they work, and switch compatible to conventional nitrogen gas source such as tubes or cryogenic liqiud. Delivery & Availability: Typically, 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from abroad The machine provides higher stimulus current, deeper cerebral stimulus penetration, and better seizure generalization. It provides the most effective form of bilateral brief pulse ECT with a 0.5msec pulsewidth that minimizes side-effects and can be delivered at every stimulus dose including the maximum dose with efficient and accurate stimulus titration.
Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
Shipped From Abroad

This machines have been developed from the well-proven Series 5A and 5B ECT apparatus. The series 6+ models incorporate all the features of the corresponding Series 5B versions. Experience has shown that a very few patients sometimes require higher dosage than was available with the earlier machines and the opportunity was therefore taken to produce equipment with a second, higher, output range.

Delivery & Availability: Typically 3 Months – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad The VentMed DF-30V-HM is a BiPAP (Bilevel Positive Airway Pressure) machine designed for sleep apnea therapy and non-invasive ventilation. It is ideal for individuals with obstructive sleep apnea (OSA), central sleep apnea (CSA), chronic obstructive pulmonary disease (COPD), and other respiratory disorders.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Contenthttps://youtu.be/JDAsx3pO4U8?si=fzekZEwG6_K2pHgL  
Features
Flexible software The advantage of the Neuron-Spectrum.NET software is its wide functionality. You can use the simple interface, or you can customize the software using the special settings. Before the study, you may choose the pre-defined electrode montage or create your own one depending on the type of test you perform. Using the convenient navigation tools, you can quickly view the recorded EEG curves, highlight artifacts, and arrange epochs. For the advanced analysis of recorded data, the contemporary tools for mathematical analysis of EEG are used. The automatic report is generated using the preset report templates and integrated glossary. The report is easily edited, saved to PDF, printed or sent automatically. Electrode impedance indication at the lead inputs The impedance indicators on the amplifier ensure the continuous impedance monitoring during the acquisition, timely correction of electrode placement and good quality of EEG recording. Operation mode can be switched with just one button on the front panel. The LED indicator next to the button shows the mode: acquisition, EEG monitoring or impedance measurement. It makes the EEG study much easier. Electrodes and caps of various manufacturers During the study, the disk, cup and bridge electrodes as well as the electrode caps of different sizes can be applied. They are connected to the amplifier unit via touch-proof connectors and standard plug. Operation in unshielded environments The EEG systems of Neuron-Spectrum line can be used in any suitable room, which is convenient for staff and comfortable for patients. The costs for preparing a specialist’s workplace are also reduced significantly. The device is small and USB powered, so you can establish your EEG lab anywhere. Download Brochure
Features
  • Targets the bilateral insula and prefrontal cortexThe H4 Coil stimulates brain structures associated with addiction. 
  • FDA-cleared for smoking addiction treatmentThe H4 Coil was cleared by the FDA to treat smoking addiction in adults. 
  • Integrated sham coilThe helmet includes a sham coil that has similar acoustic artifacts and scalp sensations as the active coil. This helps maintain blinding. 
  • Embedded in a cushioned, cooled helmetThe H-Coils are integrated into a helmet that includes a touchscreen interface, adjustable positioning arm, and foot pedal operation. 
  • Delivers electromagnetic pulsesThe H4 Coil generates electromagnetic pulses that stimulate neurons in the brain. 
  • Reaches deeper and broader brain regionsThe H-Coil design allows for deeper and broader stimulation than traditional TMS coils. 
  • Noninvasive treatmentDeep TMS is a noninvasive treatment that is well-tolerated and doesn't require a significant recovery period. 

Click here to download Brochure

PSA Industrıal nitrogen generator systems produce gas nitrogen from compressed air from the field where they work, and switch compatible to conventional nitrogen gas source such as tubes or cryogenic liqiud.

ADVANTAGES OF NITROGEN GENERATORS/PLANT

  • High flow capacity: The wide product range and gas flows exceeding 1,000 Nm³/h

  • Desired purity: Nitrogen concentrations from 95% to 99.999%.

  • Continuous availability: 24 hours a day, 7 days a week

  • Cost savings: Low operating expenses, limited maintenance costs.

  • Fully automated and monitored including oxygen sensor as standard.

Wide Range Of Applications

  • Food & beverage (storage & packaging).

  • Pharmaceutical applications.

  • Plastic injection molding.

  • Electronics.

  • Laser cutting.

  • Semiconductor manufacturing.

  • Chemical applications.

  • Metal heat treatment.

  • Cable & optical fiber industries.

  • Glass industries.

  • Fire prevention.

  • Aquaculture.

grafik_son.jpg
The machine provides higher stimulus current, deeper cerebral stimulus penetration, and better seizure generalization. It provides the most effective form of bilateral brief pulse ECT with a 0.5msec pulsewidth that minimizes side-effects and can be delivered at every stimulus dose including the maximum dose with efficient and accurate stimulus titration. Features-
  • Choose 0.25, 0.3 or 0.5msec Ultrabrief Pulsewidth
  • Genie™ IV EEG Analyzing Software
  • Four (4) - Channel Monitor/Printer
  • Optimal Stimulus Programs
  • Maximum Sustained EEG Amplitude
  • Continuous Digital Heart Rate Monitor
  • Peak Heart Rate Printout
  • EEG Coherence Analysis
  • Seizure Energy Index
  • Postictal Suppression Index
  • Maximum Dose Available at all Pulsewidths
  • Interictal Frontal Delta Analysis
  • Computer EEG Seizure Duration
  • Computer Motor Seizure Duration
  • True EMG Monitor
  • EEG Ictal Line Seizure Indicator
  • Light-Emitting Elapsed Time Display
  • Up to 8 Seconds of Stimulation
  • Change Waveform without Altering Dose
  • Audible EEG™ monitor
  • Instant Impedance Test
  • Extended Seizure Alert
  • Patented Safety Monitor Circuit
ECT Machine with Standard Accessories below: Article           Qty      Description                                                                           SYS-IV            1                     Thymatron System IV , with following accessories: EGEN              1         Genie-IV EEG Analyzing Software ELDS9            1                     Set with 9 lead wires  (4 red / 4 black / 1 green) EPAD              10       Disposable ECT treatment electrodes "Thymapad" (5 Pair) ECEF-IV        1                     EEG/EMG/ECG-monitoring cable ECET-IV        1                     ECT-treatment cable EEDS              50       Pregelled EEG/EMG stick-on electrodes EMGD           2                     Mouthguard oral protectors, 2 sizes CP110            2         Z-fold chart paper EDVD             1         Audio training DVD EMAE             2         Operating manual English ESERV           1         Service manual English For further treatments you can order separately following accessories: EECU/EEFL - Stainless steel electrode, cupped (EECU) or flat (EEFL) EHST- Headstrap, latex rubber, perforated EHAN-Electrode handle, fully shielded, for flat or cupped electrode.
Click Here To Download Catalogue
This machines have been developed from the well-proven Series 5A and 5B ECT apparatus. The series 6+ models incorporate all the features of the corresponding Series 5B versions. Experience has shown that a very few patients sometimes require higher dosage than was available with the earlier machines and the opportunity was therefore taken to produce equipment with a second, higher, output range. Features: Constant Current stimulus Delivered Dosage Displayed Patient Dynamic Impedance Indicator Simple Single Dose Control Technical Specification: Input Supply: AC 100-120, 210-240 V 40/60 Hz Load: 70 W Apparatus Size: 305 x 170 x 105mm (12” x 6.5” x 4”) Weight: 3.24kg Low Range: 50-700mC @ 750mA High Range: 200-100mC @ 900mA Contents: Two-hand headpiece: 1 C.S lead: 1 Disposable electrodes: 50 Mains cable: 1 Operating & service manual: 1 Removable stand: 1  
Click Here To Download Catalogue
This portable and home-use BiPAP device offers effective sleep therapy and is suitable for patients who require advanced respiratory support
Key Features:
  • Bi-Level Pressure Support: Provides different pressure settings for inhalation (IPAP) and exhalation (EPAP) to enhance breathing comfort.
  • Auto-Adjusting Therapy: Automatically adjusts pressure levels based on the user’s breathing needs.
  • Integrated Humidifier: Prevents dryness and irritation in the airways.
  • Real-Time Monitoring: Displays SpO2 (blood oxygen levels), pulse rate, and therapy data.
  • User-Friendly Interface: Features a full-color display and intuitive controls.
  • Quiet Operation: Low noise level for a comfortable sleep experience.
  • Data Storage & Connectivity: Compatible with SD card storage for tracking sleep therapy progress.
Specifications:
Feature Details
Modes APCV, Auto BiPAP, Auto S, CPAP, S, ST, T
Pressure Range 4 - 30 cmH₂O
Weight 1.7 kg (including humidifier)
Tubing Heated tube
Tidal Volume 200 mL - 1200 mL
Backup Rate 5 bpm - 60 bpm
Humidity Levels 1 - 5 levels (heating & humidification)
Alarms Mask off, pressure & tube abnormalities

This BiPAP machine is user-friendly, featuring an intuitive control panel and a clear display, making setup and adjustments easy for both patients and healthcare providers. It ensures stable breathing throughout the night, improving overall sleep quality

WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare