Neuron Spectrum 65 Video EEG Monitoring System
$0.00
Shipped From Abroad
The Neuron-Spectrum-65 Video EEG Monitoring System by Neurosoft is an advanced 39-channel EEG system designed for comprehensive neurophysiological diagnostics, including video EEG monitoring, polysomnography (PSG), and long-term studies. It features high-quality signal acquisition, real-time impedance monitoring, and multimodal data integration for clinical and research applications.
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
Features
- long-term video EEG monitoring
- EEG workstation and mobile system
- up to 3 Full HD video cameras
- special electrode caps
- EEG analysis during acquisition
- pre-surgical monitoring to localize pathologic activity in the brain
- data storage on removable media
Advantages
Long-term video EEG monitoring
Neuron-Spectrum-64 provides synchronous long-term video and EEG monitoring even for several days. The high-quality EEG signal and frame-accurate video synchronization are guaranteed. You can also connect the recording unit to a local area network (LAN) to place the patient in one room, and the analysis and data processing unit to another one.
EEG workstation and mobile system
Depending on your needs, we can offer you stationary or mobile system for video EEG monitoring.
If you have a special room, you can place EEG workstation here. In this case, the patient’s room and the room for EEG review and analysis can be removed from each other at any distance.
If there is no such room, the mobile system for video EEG monitoring is a perfect choice that allows you to perform examinations in any suitable room of your medical facility.
Up to 3 Full HD video cameras
In your EEG lab, you can perform continuous synchronous video EEG recording using up to 3 network cameras with maximum resolution of 1920*1080 (Full HD), automatic day and night video recording with infrared lighting, and a built-in microphone. With such functionality, you will never miss a single detail. The storage and review of recorded video is ensured by modern video compression algorithms and editing tools.
Special electrode caps
The special electrode caps with built-in electrodes are a perfect choice for long-term EEG monitoring. There is no need to use adapters or other devices, just connect the cap to the standard connector on the EEG system. Our systems are delivered with special extension cables for electrode caps for the patients to feel comfortable and move freely within the place they are examined.
The quality of electrode placement is very important during the whole acquisition process. The function of continuous impedance monitoring is implemented in Neuron-Spectrum-64. If the impedance of any electrode increases, the software informs the operator immediately. Throughout the examination, the impedance of each electrode is saved and displayed as a trend. So, you can always see the impedance value at the required time moment.
EEG analysis during acquisition
To save your time on routine operations, EEG search and analysis algorithms are built into Neuron-Spectrum.NET. And you can focus on really important things. During the acquisition, the software is already recording suspicious phenomena and making calculations and analysis of EEG signal. So, you can view the recorded video and EEG traces directly during the acquisition. By the time the examination is finished, you can create a report generated automatically according to a preset template.
Pre-surgical monitoring to localize pathologic activity in the brain
Before surgical therapy of pharmacoresistant epilepsy, it is important to localize the pathological activity in the brain. Using Neuron-Spectrum-64, you can perform the pre-surgical monitoring with both scalp and invasive (cortical or subcutaneous deep) EEG electrodes and calculate the location of pathological areas with a special 3D localization software.
During the acquisition, the monopolar, bipolar or mixed montages can be used in the 10-20 or 10-10 systems. You can change the montage at any moment: before or during the acquisition or during the review and analysis of EEG record. You can also change the channel settings. For example, if you cannot remove the EEG baseline in frontal leads, specify the higher values for high-pass filter only for them. Change the parameters of any channel directly during the acquisition.
Data storage on removable media
When the exam is finished, you can record it on a removable media and give it to the patient or send to another medical facility. Using Neuron-Spectrum.NET, you can save the study to DVD or a flash card with a special viewer program and view the examination on any computer without installation.
Specifications
Specification | Details |
---|
EEG Channels | 39 referential channels |
Differential Channels | 8 AC/DC channels (ECG, EOG, EMG, etc.) |
Dedicated Channels | Separate ECG and EOG channels |
Sampling Rate | 16 kHz ± 1% |
A/D Conversion | 24-bit resolution |
Input Voltage Range | –1.1 V to 1.1 V (software configurable) |
Input Impedance | >100 MΩ |
External Connections | SpO₂ integration support |
Connectivity | USB interface for data transfer |
Continuous Impedance Monitoring | Real-time electrode contact assessment |
Synchronous Video Recording | Supports up to 3 network cameras |
Auditory Stimulator | Supports event-related potentials (ERP) studies |
Dimensions | 200 mm (W) × 135 mm (D) × 45 mm (H) |
Weight | ~767 grams |
Quick Comparison
Settings | Neuron Spectrum 65 Video EEG Monitoring System remove | BRAINSWAY Deep TMS H4 Coil remove | Dolphin-XF Transcranial Robotic Probe remove | RESCUE LIFE 9 AED DEFIBRILLATOR with Temp, Spo2, Pacemaker remove | Dolphin-4D Transcranial Doppler Probe remove | BRAINSWAY Deep TMS H7 RCT Coil remove | ||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Name | Neuron Spectrum 65 Video EEG Monitoring System remove | BRAINSWAY Deep TMS H4 Coil remove | Dolphin-XF Transcranial Robotic Probe remove | RESCUE LIFE 9 AED DEFIBRILLATOR with Temp, Spo2, Pacemaker remove | Dolphin-4D Transcranial Doppler Probe remove | BRAINSWAY Deep TMS H7 RCT Coil remove | ||||||||||||||||||||||||||||||
Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ||||||||||||||||||||||||||||||
SKU | SF1033560130187-2 | SF1033560130162-7 | SF1033560130142-4 | SF10335601298-1 | SF1033560130142-1 | SF1033560130162-6 | ||||||||||||||||||||||||||||||
Rating | ||||||||||||||||||||||||||||||||||||
Price |
|
| $6,270.00 |
|
|
| ||||||||||||||||||||||||||||||
Stock | ||||||||||||||||||||||||||||||||||||
Availability | ||||||||||||||||||||||||||||||||||||
Add to cart | ||||||||||||||||||||||||||||||||||||
Description | Shipped From Abroad
The Neuron-Spectrum-65 Video EEG Monitoring System by Neurosoft is an advanced 39-channel EEG system designed for comprehensive neurophysiological diagnostics, including video EEG monitoring, polysomnography (PSG), and long-term studies. It features high-quality signal acquisition, real-time impedance monitoring, and multimodal data integration for clinical and research applications.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
The H4 Coil stimulates the bilateral insula and prefrontal cortex. Nearly 1 in 3 patients who completed 18 sessions achieved 4 or more weeks of abstinence from smoking in a large scale, double-blind, multicenter randomized controlled trial. 2 out of 3 patients who quit smoking by the end of treatment remained abstinent for at least an additional three months
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Proudly introducing the X-Factor in TCD robotic solutions, assisting in obtaining bilateral TCD insonations in as quickly as just a few seconds!. Designed for short and long-term monitoring, for use in anesthesia, in the ICU, or in the TCD lab.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Lightweight, ergonomic, attractive and robust portable device. Rescue Life 9 provides complete monitoring of parameters like 12 channels ECG, HR, SpO2, NIBP, Temperature and EtCO2. Synchronized cardioversion and external pacemaker in fixed or demand mode.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
The cutting-edge technology of the standalone Dolphin/4D transcranial Doppler system is the optimal TCD solution for measurements of cerebral blood flow velocities.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
The H7 Coil stimulates the anterior cingulate cortex and the medial prefrontal cortex. Treatment is designed to regulate the CSTC circuit believed to be involved in the inhibition of impulsive behavior. A sham coil is integrated above the treatment coil. To the patient and operator, the helmet appears the same, pulses sound the same, and stimulation feels the same on the scalp.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| ||||||||||||||||||||||||||||||
Content | https://youtu.be/JDAsx3pO4U8
Features
AdvantagesLong-term video EEG monitoring Neuron-Spectrum-64 provides synchronous long-term video and EEG monitoring even for several days. The high-quality EEG signal and frame-accurate video synchronization are guaranteed. You can also connect the recording unit to a local area network (LAN) to place the patient in one room, and the analysis and data processing unit to another one. EEG workstation and mobile system Depending on your needs, we can offer you stationary or mobile system for video EEG monitoring. If you have a special room, you can place EEG workstation here. In this case, the patient’s room and the room for EEG review and analysis can be removed from each other at any distance. If there is no such room, the mobile system for video EEG monitoring is a perfect choice that allows you to perform examinations in any suitable room of your medical facility. Up to 3 Full HD video cameras In your EEG lab, you can perform continuous synchronous video EEG recording using up to 3 network cameras with maximum resolution of 1920*1080 (Full HD), automatic day and night video recording with infrared lighting, and a built-in microphone. With such functionality, you will never miss a single detail. The storage and review of recorded video is ensured by modern video compression algorithms and editing tools. Special electrode caps The special electrode caps with built-in electrodes are a perfect choice for long-term EEG monitoring. There is no need to use adapters or other devices, just connect the cap to the standard connector on the EEG system. Our systems are delivered with special extension cables for electrode caps for the patients to feel comfortable and move freely within the place they are examined. The quality of electrode placement is very important during the whole acquisition process. The function of continuous impedance monitoring is implemented in Neuron-Spectrum-64. If the impedance of any electrode increases, the software informs the operator immediately. Throughout the examination, the impedance of each electrode is saved and displayed as a trend. So, you can always see the impedance value at the required time moment. EEG analysis during acquisition To save your time on routine operations, EEG search and analysis algorithms are built into Neuron-Spectrum.NET. And you can focus on really important things. During the acquisition, the software is already recording suspicious phenomena and making calculations and analysis of EEG signal. So, you can view the recorded video and EEG traces directly during the acquisition. By the time the examination is finished, you can create a report generated automatically according to a preset template. Pre-surgical monitoring to localize pathologic activity in the brain Before surgical therapy of pharmacoresistant epilepsy, it is important to localize the pathological activity in the brain. Using Neuron-Spectrum-64, you can perform the pre-surgical monitoring with both scalp and invasive (cortical or subcutaneous deep) EEG electrodes and calculate the location of pathological areas with a special 3D localization software. During the acquisition, the monopolar, bipolar or mixed montages can be used in the 10-20 or 10-10 systems. You can change the montage at any moment: before or during the acquisition or during the review and analysis of EEG record. You can also change the channel settings. For example, if you cannot remove the EEG baseline in frontal leads, specify the higher values for high-pass filter only for them. Change the parameters of any channel directly during the acquisition. Data storage on removable media When the exam is finished, you can record it on a removable media and give it to the patient or send to another medical facility. Using Neuron-Spectrum.NET, you can save the study to DVD or a flash card with a special viewer program and view the examination on any computer without installation.Specifications
| The BrainsWay Deep TMS H4 Coil is a non-invasive treatment that uses magnetic energy waves to stimulate brain structures associated with addiction and weight loss:
| https://youtu.be/JwSJvUVJrxo?si=6QkpitWAwvZZSwOM
DescriptionThe Dolphin/XF is a new breakthrough development in TCD robotics. It is designed to assist the user in quickly and automatically insonating and monitoring cerebral blood flow.Features | Progetti Rescue Life 9 is designed for out-of-hospital and hospital use.
Lightweight, ergonomic, attractive and robust portable device. Rescue Life 9 provides complete monitoring of parameters like 12 channels ECG, HR, SpO2, NIBP, Temperature and EtCO2. Synchronized cardioversion and external pacemaker in fixed or demand mode. Three operating modes: manual, AED, Advisory. Capnography waveform. Auto-test mode verifies device functions, battery status and charge-discharge system with real-time data management and report printing. The IPX4 permits operations under adverse climatic situations.
Rescue Life 9 Technical Specification:
General requirements
• Dimension: 335x225x360 mm
• Weight: 6.5 kg with dual batteries
• Electrical: AC 100-240 VAC, 50/60 Hz
• Rechargeable Lithium-ion batteries: 15.0 V - 3.2 Ah
• Battery Operation Time:
>5 hours, with 1 battery
>10 hours with 2 batteries
• Charge Time: Max. 3 hours
• Capacity: 150 shocks with 1 battery or 300 shocks with 2 batteries at 230J fully charged
• Software: Voice and text multi-language
• Memory: Internal flash for ECG data, events and usage review
Defibrillation
• Waveform: Biphasic Truncated Exponential (BTE), HiCAP technology (Large storage capacitor)
• Impedance: Compensated, range 25-200 Ohm
• Charge time: 6 sec for 230 J with the battery fully charged
AED mode
• Energy: Fixed energy at 200 J
• Protocol: ERC 2015 CPR Guidelines with voice and text prompts
• Shockable rhythms: VF with amplitude > 0.15 mV and VT with rhythm >150 bpm
• Sensitivity: Shockable rhythm -VF > 95%, -VT > 75%
• Specificity: According to ERC 2015,
• Normal sinusoidal rhythm > 99%
• Asystole and other non-shockable rhythms > 99%
Manual mode
• Energy range: 1-230 J (from 1-10 J in 1 J steps; from 10 to 230 J in 10 J steps)
• Commands: Multifunction trim knob
• Charge and shock button in the front panel
• Operating mode: EC G «R» wave synchro or async mode
• Indicators: Battery and main led indicators
Display
• Type: High contrast TFT colour LCD 8” (800x600 dots)
• Information: ECG traces, SpO2, NIBP, EtCO2, TEMP, Heart Rate indicator, filters, alarms and the batteries status
• Display mode: Can select 3, 6, 12 ECG leads
Ecg monitoring
• Bandwidth:
0.05 - 120 Hz (-3 db) in diagnostic mode
0.6 - 40 Hz (-3 db) in monitoring mode
• CMRR: > 98 dbv Input impedance: > 50 Mohm
• Input:
Patient cable 5 leads (I, II, III, aVL, aVF, aVR, V) - standard
Patient cable 10 leads (I, II, III, aVL, aVF, aVR, V1…..V6) - optional
• Speed: 5, 10, 25, 50 mm/sec
• Filters: 50/60 Hz, EMG Filter, base line
• HR range: 20-300 bpm (~2%), digital readout on the display
• Alarm: HR max settable 250 bpm; HR min 20 bpm
SpO2 (only 55505-55512)
• SpO2 range: 0-100% HR range: 30-250 bpm
• Accuracy: 70-100% ~2% for adults with finger clip sensor
• Alarm: Adjustable min 50%
Temperature
• Probe type: YSI400 compatible
• Range: 0 to 50° C
• Resolution: ±0.1° C
Standard
• IEC 60601-2-4; IEC 60601-1; IEC 60601-1-2; IEC 63204, IEC 62366-1
• CE Mark EEC 93/42: Medical device, Class IIb
• Isolation: ECG type CF, Defibrillation type BF
• Waterproof: Class IP54
| https://youtu.be/Id0Ma1_lEo0?si=MmwcCTMMPZd_jf6h
Features of Dolphin TCD Machine | The Brainsway Deep TMS H7 RCT Coil is a flexible coil used in transcranial magnetic stimulation (TMS) to treat obsessive-compulsive disorder (OCD) and other neuropsychiatric conditions:
Features
| ||||||||||||||||||||||||||||||
Weight | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||||||||||
Dimensions | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||||||||||
Additional information |
Reviews
There are no reviews yet.